Nonlinear intravascular ultrasound contrast imaging.
Nonlinear contrast agent imaging with intravascular ultrasound (IVUS) is investigated using a prototype IVUS system and an experimental small bubble contrast agent. The IVUS system employed a mechanically scanned single element transducer and was operated at a 20 MHz transmit frequency (F20) for second harmonic imaging (H40), and at a 40 MHz transmit frequency (F40) for subharmonic imaging (SH20). Characterization experiments were performed with agent and tissue phantom signals acquired during transducer rotation. The suppression of transmit frequency tissue signals was achieved using a combination of pulse-inversion and bandpass filtering. H40 was found to improve the contrast-to-tissue signal ratio (CTR) by up to 22 dB relative to F20, but suffered from tissue propagation harmonics at higher pressures (>0.3 MPa). SH20 was also shown to be possible at a range of pressures (approximately 0.25 to 1.8 MPa), with tissue signals suppressed to near the noise floor. Coronary phantom experiments demonstrated the detection of agent in 1 mm diameter vessels outside a larger 4 mm diameter vessel in which the IVUS catheter was situated. These results suggest the feasibility of harmonic IVUS contrast imaging, which may have applications in coronary lumen boundary detection and vasa vasorum imaging.
High frequency nonlinear scattering from a micrometer to submicrometer sized lipid encapsulated contrast agent.
An experimental lipid encapsulated contrast agent comprised substantially of micrometer to submicrometer diameter bubbles was evaluated for its capacity to produce nonlinear scattering in response to high transmit frequencies. Agent characterization experiments were conducted at transmit frequencies of 20 and 30 MHz with bandwidths of 5, 15 and 25% using a broadband focused PVDF transducer. The presence of subharmonic energy was observed for all bandwidths at a wide range of pressures (0.49 to 5.7 MPa and 0.45 to 4.5 MPa for the 20 and 30 MHz cases, respectively). Distinct ultraharmonics were observed only in the 5% bandwidth cases. Second harmonic energy was also present, but this was at least partly due to nonlinear propagation, as indicated by linear scatterer signals. Evidence of destruction was found only at higher peak negative pressures (e.g., >2 MPa for 30 MHz 5% bandwidth pulse). The results suggest that small lipid bubble formulations may be useful for the purposes of high frequency nonlinear contrast imaging.
Harmonic intravascular ultrasound imaging with a dual-frequency catheter.
Recent studies have shown the feasibility of tissue and contrast harmonic imaging with a prototype nonlinear intravascular ultrasound (IVUS) system using a conventional single-element rotating IVUS catheter. In this study, a dual-frequency transducer element was mounted in an IVUS catheter and its second harmonic imaging performance was investigated and compared with that of a conventional IVUS catheter. Hydrophone measurements showed a transmit efficiency improvement of >6 dB for the dual-frequency catheter at 20 MHz. In vitro phantom experiments showed a signal-to noise ratio improvement of >5 dB in second harmonic mode at 40 MHz (H40) with the dual-frequency catheter, when using equal transmit voltage for both catheters. Finally, in vivo experiments were conducted and showed image improvement in H40 acquisitions with respect to the conventional IVUS catheter.
Contrast harmonic intravascular ultrasound: a feasibility study for vasa vasorum imaging.
OBJECTIVE: We sought to investigate feasibility of vasa vasorum imaging using the novel technique of contrast harmonic intravascular ultrasound. METHODS: Prototype intravascular ultrasound (IVUS) instrumentation was developed for the sensitive detection of micro-bubble contrast agents. The technique, "harmonic" imaging, involves transmitting ultrasound at 20 MHz (fundamental) and detecting contrast signals at 40 MHz (second harmonic). Phantom experiments were conducted to investigate the detection of a small vessel in the wall surrounding a larger vessel. In vivo experiments were conducted in atherosclerotic rabbit abdominal aortas. RESULTS: The phantom experiments showed improved small vessel detection in harmonic mode relative to fundamental mode. For the in vivo experiments, harmonic imaging enabled the visualization of contrast agent outside the aortic lumen through a statistically significant (P < 0.001) enhancement of image power, consistent with the detection of adventitial microvessels. These microvessels were not detected in fundamental imaging mode. CONCLUSIONS: These results indicate the feasibility of contrast harmonic intravascular ultrasound as a new technique for vasa vasorum imaging.
Intravascular ultrasound tissue harmonic imaging in vivo.
Tissue harmonic imaging (THI) has been shown to increase image quality of medical ultrasound in the frequency range from 2 to 10 MHz and might, therefore, also be used to improve image quality in intravascular ultrasound (IVUS). In this study we constructed a prototype IVUS system that could operate in both fundamental frequency and second harmonic imaging modes. This system uses a conventional, continuously rotating, single-element IVUS catheter and was operated in fundamental 20 MHz, fundamental 40 MHz, and harmonic 40 MHz modes (transmit 20 MHz, receive 40 MHz). Hydrophone beam characterization measurements demonstrated the build-up of a second harmonic signal as a function of increasing pressure. Imaging experiments were conducted in both a tissue-mimicking phantom and in an atherosclerotic animal model in vivo. Acquisitions of fundamental 20 and 40 MHz and second harmonic acquisitions resulted in cross sections of the phantom and a rabbit aorta. The harmonic results of the imaging experiments showed the feasibility of intravascular THI with a conventional IVUS catheter both in a phantom and in vivo. The harmonic acquisitions also showed the potential of THI to reduce image artifacts compared to fundamental imaging.
A simulation study on tissue harmonic imaging with a single-element intravascular ultrasound catheter.
Recently, in vivo feasibility of tissue harmonic imaging with a mechanically rotated intravascular ultrasound (IVUS) catheter was experimentally demonstrated. To isolate the second harmonic signal content, a combination of pulse inversion and analog filtering was used. In this paper the development of a simulation tool to investigate nonlinear IVUS beams is reported, and the influence of transducer rotation and axial catheter-to-tissue motion on the efficiency of PI signal processing is evaluated. Nonlinear beams were simulated in homogeneous tissue-mimicking media at a transmit frequency of 20 MHz, which resulted in second harmonic pressure fields at 40 MHz. The competing effects of averaging and decorrelation between neighboring rf lines on the signal-to-noise ratio (SNR) were studied for a single point scatterer. An optimal SNR was achieved when lines were combined over 3 degrees - 3.75 degrees. When the transducer was rotated with respect to point scatterers, simulating the acoustic response of tissue, the fundamental frequency suppression using PI degraded rapidly with increasing interpulse angles. The effect of axial catheter-to-tissue motion on the efficiency of pulse inversion seemed to be of less influence for realistic motion values. The results of this study will aid in the optimization of harmonic IVUS imaging systems.
High frequency nonlinear B-scan imaging of microbubble contrast agents.
It previously was shown that it is possible to produce nonlinear scattering from microbubble contrast agents using transmit frequencies in the 14-32 MHz range, suggesting the possibility of performing high-frequency, nonlinear microbubble imaging. In this study, we describe the development of nonlinear microbubble B-scan imaging instrumentation capable of operating at transmit center frequencies between 10 and 50 MHz. The system underwent validation experiments using transmit frequencies of 20 and 30 MHz. Agent characterization experiments demonstrate the presence of nonlinear scattering for the conditions used in this study. Using wall-less vessel phantoms, nonlinear B-scan imaging is performed using energy in one of the subharmonic, ultraharmonic, and second harmonic frequency regions for transmit frequencies of 20 and 30 MHz. Both subharmonic and ultraharmonic imaging modes achieved suppression of tissue signals to below the noise floor while achieving contrast to noise ratios of up to 26 and 17 dB, respectively. The performance of second harmonic imaging was compromised by nonlinear propagation and offered no significant contrast improvement over fundamental mode imaging. In vivo experiments using the subharmonic of a 20 MHz transmit pulse show the successful detection of microvessels in the rabbit ear and in the mouse heart. The results of this study demonstrate the feasibility of nonlinear microbubble imaging at high frequencies.
High-frequency, nonlinear flow imaging of microbubble contrast agents.
It has been shown that nonlinear scattering can be stimulated from microbubble contrast agents at high-transmit frequencies (14-32 MHz). This work was extended to demonstrate the feasibility of nonlinear contrast imaging through modifications of existing ultrasound biomicroscopy linear B-scan imaging instrumentation. In this study, we describe the development and evaluation of prototype coherent flow imaging instrumentation for nonlinear microbubble imaging using transmit frequencies from 10 to 50 MHz. Phantom validation experiments were conducted to demonstrate color and power flow imaging using nonlinear 10 MHz (subharmonic) scattering induced by a 20 MHz transmit frequency. In vivo flow imaging of a rabbit ear microvessel was successfully performed. This work indicates the feasibility of performing flow imaging at high frequencies using nonlinear scattering from microbubbles.
Transducer for harmonic intravascular ultrasound imaging.
A recent study has shown the feasibility of tissue harmonic imaging (THI) using an intravascular ultrasound (IVUS) transducer. This correspondence describes the design, fabrication, and characterization of a THI-optimized piezoelectric transducer with oval aperture of 0.75 mm by 1 mm. The transducer operated at 20 MHz and 40 MHz, and was comprised of a single piezoelectric layer with additional passive layers. The Krimholtz-Leedom-Matthaei (KLM) model was used to iteratively find optimal material properties of the different layers. The transducer characterization showed -6 dB fractional bandwidths of 30% and 25%, and two-way insertion losses of -20 dB and -36 dB, respectively.
High-frequency 3-D color-flow imaging of the microcirculation.
High-frequency (> 20 MHz) ultrasound (US) flow imaging has the potential to be an important tool for assessing microvascular blood flow in superficial tissues noninvasively. In this paper, we describe the development and evaluation of a 3-D US flow imaging system capable of operating at center frequencies in the 20- to 50-MHz range. Flow images are made for tissue volumes of sizes up to 10 mm laterally and 5 mm in depth, permitting a range of scientific and clinical applications. To acquire data sets in a reasonable time, the 2-D sections were derived from data collected with a transducer that was scanning continuously in a direction perpendicular to the beam axis. Due to spectral broadening effects induced by scanning tissue, significant tradeoffs must be made between frame rate, lateral resolution and the minimum detectable blood velocity. 3-D flow images were reconstructed with flow data acquired from a series of adjacent planes. The system was evaluated at a center frequency of 50 MHz, using two PVDF transducers with lateral resolutions of 43 microm and 65 microm and axial resolutions of 66 microm to 72 microm, respectively. Velocity ranges were from below 1 mm/s to 25 mm/s. In vivo validation experiments using the mouse ear demonstrated the ability to follow branching patterns of closely spaced microvessels from 30 microm to 100 microm in diameter. Experiments conducted on mouse tumors successfully imaged microvessel morphology in the tumor microcirculation.
High-frequency Doppler ultrasound monitors the effects of antivascular therapy on tumor blood flow.
The effect of antivascular therapy on blood flow in superficial tumors was monitored using novel high frequency Doppler (HFD) ultrasound techniques. Human melanoma cells (MeWo) were injected orthotopically into the skin of athymic nude mice. Volumetric HFD imaging of established melanomas detected a significant reduction in blood flow 4 h after injection of the tumor vascular targeting agent ZD6126 followed by a recovery of flow by 24 h after injection. Measurements of tumor perfusion in situ by Hoechst 33342 staining correlated with the ultrasound results. This study demonstrates the feasibility of HFD as a noninvasive, quantitative tool for following longitudinally the effects of antivascular therapy on blood flow in superficial tumors.