PubMed Health⌕ Search

Biomedical subjects

David E Wright

Publications and source records attributed to David E Wright.

5 recordsLinked to original sources

Assessing newborn body composition using principal components analysis: differences in the determinants of fat and skeletal size.

BACKGROUND: Birth weight is a composite of skeletal size and soft tissue. These components are likely to have different growth patterns. The aim of this paper is to investigate the association between established determinants of birth weight and these separate components. METHODS: Weight, length, crown-rump, knee-heel, head circumference, arm circumference, and skinfold thicknesses were measured at birth in 699 healthy, term, UK babies recruited as part of the Exeter Family Study of Childhood Health. Corresponding measurements were taken on both parents. Principal components analysis with varimax rotation was used to reduce these measurements to two independent components each for mother, father and baby: one highly correlated with measures of fat, the other with skeletal size. RESULTS: Gestational age was significantly related to skeletal size, in both boys and girls (r = 0.41 and 0.52), but not fat. Skeletal size at birth was also associated with parental skeletal size (maternal: r = 0.24 (boys), r = 0.39 (girls) ; paternal: r = 0.16 (boys), r = 0.25 (girls)), and maternal smoking (0.4 SD reduction in boys, 0.6 SD reduction in girls). Fat was associated with parity (first borns smaller by 0.45 SD in boys; 0.31 SD in girls), maternal glucose (r = 0.18 (boys); r = 0.27 (girls)) and maternal fat (r = 0.16 (boys); r = 0.36 (girls)). CONCLUSION: Principal components analysis with varimax rotation provides a useful method for reducing birth weight to two more meaningful components: skeletal size and fat. These components have different associations with known determinants of birth weight, suggesting fat and skeletal size may have different regulatory mechanisms, which would be important to consider when studying the associations of birth weight with later adult disease.

Adiposity↗

Repeated measurement of pregnancy-associated plasma protein-A (PAPP-A) in Down syndrome screening: a validation study.

OBJECTIVES: To confirm that measuring pregnancy-associated plasma protein-A (PAPP-A) in both first- and second-trimester serum samples improves Down syndrome screening. METHODS: We selected paired first- and second-trimester stored serum samples from 34 Down syndrome pregnancies (cases) and 514 unaffected pregnancies (controls) and tested the second-trimester samples for PAPP-A and dimeric inhibin-A (DIA). First-trimester PAPP-A measurements were already available, as were second-trimester measurements of alpha-fetoprotein, unconjugated estriol (uE3), and human chorionic gonadotrophin (hCG). RESULTS: PAPP-A was lower among cases than controls (0.47 MoM) in the first trimester (at an average of 12.5 weeks); in the second trimester, it was not different (0.91 MoM). Using repeated measures of PAPP-A alone, 21 of 34 cases were detected (62%, 95%CI 44% to 78%) with 5% false positives. At an observed 2% false-positive rate, the detection rates (DR) for the quadruple (69%) and serum integrated (69%) tests were lower than for the repeated measures test (75%). Modelled performance at 12 weeks was similar to these observed findings (70, 75, and 82%, respectively). If the first-trimester samples were collected at 10 weeks, however, DR would be higher (70, 81, and 91%, respectively). CONCLUSIONS: Adding a repeated measure of PAPP-A to existing serum markers improves Down syndrome screening to levels that are currently obtainable only by including ultrasound measurement of nuchal translucency (NT). Serum-based screening has the advantages of higher availability and reliability at a lower cost, resulting in a more effective screening strategy. A serum-based repeated measures test has a place in routine Down syndrome screening.

Adult↗

Repeated measures screening for Down's Syndrome.

OBJECTIVE: To demonstrate the potential value of screening for Down's Syndrome using highly correlated repeated measures of serum markers taken in the first and second trimesters of pregnancy. DESIGN: A Monte Carlo simulation study. POPULATION: Detection rates and false positive rates relating to the maternal age distribution of England and Wales for the period 1996 to 1998 were obtained using marker distributions from the SURUSS study. RESULTS: Screening using first trimester nuchal translucency and repeated measures of uE3 and PAPP-A in the first and second trimester has an estimated false positive rate of 0.3% for an 85% detection rate. This should be compared with the integrated test with an estimated false positive rate of 1.2% for the same detection rate. CONCLUSIONS: The performance of repeated measures screening tests, and their acceptability to women, should be assessed in further prospective studies.

Biomarkers↗