PubMed Health⌕ Search

Biomedical subjects

David Erickson

Publications and source records attributed to David Erickson.

13 recordsLinked to original sources

Nanofluidic tuning of photonic crystal circuits.

By integrating soft-lithography-based nanofluidics with silicon nanophotonics, we demonstrate dynamic, liquid-based addressing and high deltan/n (approximately 0.1) refractive index modulation of individual features within photonic structures at subwavelength length scales. We show ultracompact tunable spectral filtering through nanofluidic targeting of a single row of holes within a planar photonic crystal. We accomplished this with an optofluidic integration architecture comprising a nanophotonic layer, a nanofluidic delivery structure, and a microfluidic control engine. Variants of this technique could enable dynamic reconfiguration of photonic circuits, selective introduction of optical nonlinearities, or delivery of single molecules into resonant cavities for biodetection.

Journal Article↗

A doctor's story.

Explore the source record for details and available documents.

Career Choice↗

Electrokinetically based approach for single-nucleotide polymorphism discrimination using a microfluidic device.

In this work, we describe and implement an electrokinetic approach for single-nucleotide polymorphism (SNP) discrimination using a PDMS/glass-based microfluidic chip. The technique takes advantage of precise control of the coupled thermal (Joule heating), shear (electroosmosis), and electrical (electrophoresis) energies present at an array of probes afforded by the application of external electrical potentials. Temperature controllers and embedded thermal devices are not required. The chips can be easily and inexpensively fabricated using standard microarray printing methods combined with soft-lithography patterned PDMS fluidics, making these systems easily adaptable to applications using higher density arrays. Extensive numerical simulations of the coupled flow and thermal properties and microscale thermometry experiments are described and used to characterize the in-channel conditions. It was found that optimal conditions for SNP detection occur at a lower temperature on-chip than for typical microarray experiments, thereby revealing the importance of the electrical and shear forces to the overall process. To demonstrate the clinical utility of the technique, the detection of single-base pair mutations in the survival motor neuron gene, associated with the childhood disease spinal muscular atrophy, is conducted.

Cyclic AMP Response Element-Binding Protein↗

Electrokinetically controlled DNA hybridization microfluidic chip enabling rapid target analysis.

Biosensors and more specifically biochips exploit the interactions between a target analyte and an immobilized biological recognition element to produce a measurable signal. Systems based on surface nucleic acid hybridization, such as microarrays, are particularly attractive due to the high degree of selectivity in the binding interactions. One of the drawbacks of this reaction is the relatively long time required for complete hybridization to occur, which is often the result of diffusion-limited reaction kinetics. In this work, an electrokinetically controlled DNA hybridization microfluidic chip will be introduced. The electrokinetic delivery technique provides the ability to dispense controlled samples of nanoliter volumes directly to the hybridization array (thereby increasing the reaction rate) and rapidly remove nonspecific adsorption, enabling the hybridization, washing, and scanning procedures to be conducted simultaneously. The result is that all processes from sample dispensing to hybridization detection can be completed in as little as 5 min. The chip also demonstrates an efficient hybridization scheme in which the probe saturation level is reached very rapidly as the targets are transported over the immobilized probe site enabling quantitative analysis of the sample concentration. Detection levels as low as 50 pM have been recorded using an epifluorescence microscope.

Adsorption↗

Development of a novel microfluidic immunoassay for the detection of Helicobacter pylori infection.

The miniaturization of laboratory processes offers substantial advantages over traditional techniques in terms of cost, speed, and potential for multistage automation. To date, only a few studies have reported successful microfluidics-based immunoassays, most of which rely on fluorescence detection technologies. The goal of this study was to develop a poly(dimethylsiloxane) microfluidics-based immunoassay methodology and a versatile colorimetric quantification scheme for the detection of visual colour changes resulting from immune reactions in microchannels. The novel immunoassay technique was applied towards the detection of Helicobacter pylori infection using 20 human serum samples of known infection status, and results compared with conventional nitrocellulose membrane-based dot-ELISA. The microchannel immunoassay reliably detected H. pylori antigens in quantities on the order of 10 ng, which provides a sensitivity of detection comparable to conventional dot-blot assays. Sensitivity was 100%, specificity was 90%, positive predictive value 91%, and negative predictive value 100%, with an overall accuracy of 95%. The software developed generated results that were consistent with visual observations and by automatically taking into account background intensity changes, the software minimized subjectivity. Volumes of solutions used were 100-fold less compared with conventional immunoassays. Miniaturization of the ELISA using this technique provides a means for the accurate diagnosis of microbial infection while minimizing waste production.

Antigens, Bacterial↗

Heterogeneous surface charge enhanced micromixing for electrokinetic flows.

Enhancing the species mixing in microfluidic applications is key to reducing analysis time and increasing device portability. The mixing in electroosmotic flow is usually diffusion-dominated. Recent numerical studies have indicated that the introduction of electrically charged surface heterogeneities may augment mixing efficiencies by creating localized regions of flow circulation. In this study, we experimentally visualized the effects of surface charge patterning and developed an optimized electrokinetic micromixer applicable to the low Reynolds number regime. Using the optimized micromixer, mixing efficiencies were improved between 22 and 68% for the applied potentials ranging from 70 to 555 V/cm when compared with the negatively charged homogeneous case. For producing a 95% mixture, this equates to a potential decrease in the required mixing channel length of up to 88% for flows with Péclet numbers between 190 and 1500.

Journal Article↗

Ionic strength-dependent pK shift in the helix-coil transition of grafted poly(L-glutamic acid) layers analyzed by electrokinetic and ellipsometric measurements.

Surface-bound layers of poly(L-glutamic acid) prepared by a recently described "grafting-from" method were analyzed with respect to electrical charging and structural alterations upon variation of pH and concentration of the background electrolyte in aqueous solutions. The microslit electrokinetic setup (MES) was utilized for the combined determination of zeta potential and surface conductivity on the basis of streaming potential and streaming current measurements at polypeptide layers in contact with aqueous electrolyte solutions of varied composition. In situ ellipsometry was applied at similar samples immersed in identical aqueous solutions to investigate the influence of the solution pH on the structure of the polypeptide layers. Zeta potential and Dukhin number versus pH plots revealed the dissociation behavior of the surface-bound polypeptides indicating a significant shift of the pK of their acidic side chains correlating with the concentration of the background electrolyte potassium chloride and the related variation of the Debye screening length. Surface conductivity data pointed at a more expanded structure of the polypeptide layer in the fully dissociated state as an increased ion conductance in this part of the interface was determined. The occurrence of a strong increase of the thickness and a corresponding decrease of the refractive index for the coil state of the layer strongly supports the findings of the electrokinetic measurements. This fully reversible "switching" of the layer structure was attributed to helix-coil transitions within the grafted polypeptides induced by the dissociation of carboxylic acid functions of the polypeptide side chains. The shift of the "switching pH" of the surface-bound poly(L-glutamic acid) layers at varied concentrations of the background electrolyte was interpreted as a result of the pK shift of the carboxylic acid groups of the polypeptide side chains. The observed patterns prove that the electrostatic interactions causing this shift occur within but not between the grafted chains.

Electrochemistry↗

A miniaturized high-voltage integrated power supply for portable microfluidic applications.

In this work a portable microfluidic device with a reusable integrated high voltage power supply is presented, which allows for quick exchange of inexpensive disposable poly(dimethylsiloxane)(PDMS) microfluidic chips on a carrier only slightly larger than a microscope slide. The device is powered by an onboard MN21 cell battery (5 mm radius, 30 mm long) and is demonstrated through the rapid and controlled transport of a fluorescent dye through an expansion chamber geometry. Power consumption experiments demonstrate the device's ability to complete over 40 dispense-flushing cycles on a single battery.

Dimethylpolysiloxanes↗

Joule heating and heat transfer in poly(dimethylsiloxane) microfluidic systems.

Joule heating is a significant problem in electrokinetically driven microfluidic chips, particularly polymeric systems where low thermal conductivities amplify the difficulty in rejecting this internally generated heat. In this work, a combined experimental (using a microscale thermometry technique) and numerical (using a 3D "whole-chip" finite element model) approach is used to examine Joule heating and heat transfer at a microchannel intersection in poly(dimethylsiloxane)(PDMS), and hybrid PDMS/Glass microfluidic systems. In general the numerical predictions and the experimental results agree quite well (typically within +/- 3 degree C), both showing dramatic temperature gradients at the intersection. At high potential field strengths a nearly five fold increase in the maximum buffer temperature was observed in the PDMS/PDMS chips over the PDMS/Glass systems. The detailed numerical analysis revealed that the vast majority of steady state heat rejection is through lower substrate of the chip, which was significantly impeded in the former case by the lower thermal conductivity PDMS substrate. The observed higher buffer temperature also lead to a number of significant secondary effects including a near doubling of the volume flow rate. Simple guidelines are proposed for improving polymeric chip design and thereby extend the capabilities of these microfluidic systems.

Computer Simulation↗

Modeling of DNA hybridization kinetics for spatially resolved biochips.

The marriage of microfluidics with detection technologies that rely on highly selective nucleic acid hybridization will provide improvements in bioanalytical methods for purposes such as detection of pathogens or mutations and drug screening. The capability to deliver samples in a controlled manner across a two-dimensional hybridization detection platform represents a substantial technical challenge in the development of quantitative and reusable biochips. General theoretical and numerical models of heterogeneous hybridization kinetics are required in order to design and optimize such biochips and to develop a quantitative method for online interpretation of experimental results. In this work we propose a general kinetic model of heterogeneous hybridization and develop a technique for estimating the kinetic coefficients for the case of well-spaced, noninteracting surface-bound probes. The experimentally verified model is then incorporated into the BLOCS (biolab-on-a-chip simulation) 3D microfluidics finite element code and used to model the dynamic hybridization on a biochip surface in the presence of a temperature gradient. These simulations demonstrate how such a device can be used to discriminate between fully complementary and single-base-pair mismatched hybridization using fluorescence detection by interpretation of the unique spatially resolved intensity pattern. It is also shown how the dynamic transport of the targets is likely to affect the rate and location of hybridization as well as that, although nonspecific hybridization is present, the change in the concentration of hybridized targets over the sensor platform is sufficiently high to determine if a fully complementary match is present. Practical design information such as the optimum transport speed, target concentration, and channel height is presented. The results presented here will aid in the interpretation of results obtained with such a temperature-gradient biochip.

Biosensing Techniques↗

Zeta-potential measurement using the Smoluchowski equation and the slope of the current-time relationship in electroosmotic flow.

The zeta -potential of a solid-liquid interface is an important surface characterization quantity for applications ranging from the development of biomedical polymers to the design of microfluidic devices. This study presents a novel experimental technique to measure the zeta -potentials of flat surfaces. This method combines the Smoluchowski equation with the measured slope of current-time relationship in electroosmotic flow. This method is simple and accurate in comparison with the traditional streaming potential and electrophoresis techniques. Using this method the zeta -potentials of glass and poly(dimethylsiloxane) (PDMS) coated surfaces in KCl and LaCl3 aqueous solutions were measured using several flow channels ranging from 200 to 300 microm in height. The zeta -potential was found to vary from -88 to -66 mV for glass surface and -110 to -68 mV for PDMS surfaces depending on the electrolyte and the ionic concentration. The measured values of the zeta -potential are found to be independent of the channel size and the applied driving voltage and generally are repeatable within +/-6%.

Journal Article↗

Streaming Potential and Streaming Current Methods for Characterizing Heterogeneous Solid Surfaces.

By monitoring changes in electrokinetic parameters, the streaming potential technique has been used as a method of characterizing heterogeneous surfaces, for example, due to protein adsorption. In general it is assumed that the change in the streaming potential is proportional to the degree of heterogeneity. In this study a simple model of the electrokinetic flow through heterogeneous slit channels has been developed with the goal of comparing the streaming potential and streaming current techniques and determining under what conditions the aforementioned proportionality assumption will produce erroneous results. The flow simulations have shown that, when the streaming potential induces significant flow impedance, a severe deviation from the linear assumption is observed. Since streaming current measurements are unaffected by electrokinetic flow effects, more consistent results are predicted and they are preferred for measurements made in small channels. Additionally it has been shown that the distribution of the heterogeneous coverage has a negligible effect on both the streaming potential and the streaming current in cases where the double-layer overlap is not significant. Copyright 2001 Academic Press.

Journal Article↗