PubMed Health⌕ Search

Biomedical subjects

David Frakes

Publications and source records attributed to David Frakes.

5 recordsLinked to original sources

Total cavopulmonary connection flow with functional left pulmonary artery stenosis: angioplasty and fenestration in vitro.

BACKGROUND: In our multicenter study of the total cavopulmonary connection (TCPC), a cohort of patients with long-segment left pulmonary artery (LPA) stenosis was observed (35%). The clinically recognized detrimental effects of LPA stenosis motivated a computational fluid dynamic simulation study within 3-dimensional patient-specific and idealized TCPC pathways. The goal of this study was to quantify and evaluate the hemodynamic impact of LPA stenosis and to judge interventional strategies aimed at treating it. METHODS AND RESULTS: Simulations were conducted at equal vascular lung resistance, modeling both discrete stenosis (DS) and diffuse long-segment hypoplasia with varying degrees of obstruction (0% to 80%). Models having fenestrations of 2 to 6 mm and atrium pressures of 4 to 14 mm Hg were explored. A patient-specific, extracardiac TCPC with 85% DS was studied in its original configuration and after virtual surgery that dilated the LPA to 0% stenosis in the computer medium. Performance indices improved exponentially (R2>0.99) with decreasing obstruction. Diffuse long-segment hypoplasia was approximately 50% more severe with regard to lung perfusion and cardiac energy loss than DS. Virtual angioplasty performed on the 3-dimensional Fontan anatomy exhibiting an 85% DS stenosis produced a 61% increase in left lung perfusion and a 50% decrease in cardiac energy dissipation. After 4-mm fenestration, TCPC baffle pressure dropped by approximately 10% and left lung perfusion decreased by approximately 8% compared with the 80% DS case. CONCLUSIONS: DS <60% and diffuse long-segment hypoplasia <40% could be considered tolerable because both resulted in only a 12% decrease in left lung perfusion. In contrast to angioplasty, a fenestration (right-to-left shunt) reduced TCPC pressure at the cost of decreased left and right lung perfusion. These results suggest that pre-Fontan computational fluid dynamic simulation may be valuable for determining both the hemodynamic significance of LPA stenosis and the potential benefits of intervention.

Angioplasty↗

Physics-driven CFD modeling of complex anatomical cardiovascular flows-a TCPC case study.

Recent developments in medical image acquisition combined with the latest advancements in numerical methods for solving the Navier-Stokes equations have created unprecedented opportunities for developing simple and reliable computational fluid dynamics (CFD) tools for meeting patient-specific surgical planning objectives. However, for CFD to reach its full potential and gain the trust and confidence of medical practitioners, physics-driven numerical modeling is required. This study reports on the experience gained from an ongoing integrated CFD modeling effort aimed at developing an advanced numerical simulation tool capable of accurately predicting flow characteristics in an anatomically correct total cavopulmonary connection (TCPC). An anatomical intra-atrial TCPC model is reconstructed from a stack of magnetic resonance (MR) images acquired in vivo. An exact replica of the computational geometry was built using transparent rapid prototyping. Following the same approach as in earlier studies on idealized models, flow structures, pressure drops, and energy losses were assessed both numerically and experimentally, then compared. Numerical studies were performed with both a first-order accurate commercial software and a recently developed, second-order accurate, in-house flow solver. The commercial CFD model could, with reasonable accuracy, capture global flow quantities of interest such as control volume power losses and pressure drops and time-averaged flow patterns. However, for steady inflow conditions, both flow visualization experiments and particle image velocimetry (PIV) measurements revealed unsteady, complex, and highly 3D flow structures, which could not be captured by this numerical model with the available computational resources and additional modeling efforts that are described. Preliminary time-accurate computations with the in-house flow solver were shown to capture for the first time these complex flow features and yielded solutions in good agreement with the experimental observations. Flow fields obtained were similar for the studied total cardiac output range (1-3 1/min); however hydrodynamic power loss increased dramatically with increasing cardiac output, suggesting significant energy demand at exercise conditions. The simulation of cardiovascular flows poses a formidable challenge to even the most advanced CFD tools currently available. A successful prediction requires a two-pronged, physics-based approach, which integrates high-resolution CFD tools and high-resolution laboratory measurements.

Blood Flow Velocity↗

Single-step stereolithography of complex anatomical models for optical flow measurements.

Transparent stereolithographic rapid prototyping (RP) technology has already demonstrated in literature to be a practical model construction tool for optical flow measurements such as digital particle image velocimetry (DPIV), laser doppler velocimetry (LDV), and flow visualization. Here, we employ recently available transparent RP resins and eliminate time-consuming casting and chemical curing steps from the traditional approach. This note details our methodology with relevant material properties and highlights its advantages. Stereolithographic model printing with our procedure is now a direct single-step process, enabling faster geometric replication of complex computational fluid dynamics (CFD) models for exact experimental validation studies. This methodology is specifically applied to the in vitro flow modeling of patient-specific total cavopulmonary connection (TCPC) morphologies. The effect of RP machining grooves, surface quality, and hydrodynamic performance measurements as compared with the smooth glass models are also quantified.

Blood Flow Velocity↗

Three-dimensional velocity field reconstruction.

The problem of inter-slice magnetic resonance (MR) image reconstruction is encountered often in medical imaging applications, in such scenarios, there is a need to approximate information not captured in contiguously acquired MR images due to hardware sampling limitations. In the context of velocity field reconstruction, these data are required for visualization and computational analyses of flow fields to be effective. To provide more complete velocity information, a method has been developed for the reconstruction of flow fields based on adaptive control grid interpolation (ACGI). In this study, data for reconstruction were acquired via MRJ from in vitro models of surgically corrected pediatric cardiac vasculatures. Reconstructed velocity fields showed strong qualitative agreement with those obtained via other acquisition techniques. Quantitatively reconstruction was shown to produce data of comparable quality to accepted velocity data acquisition methods. Results indicate that ACGI-based velocity field reconstruction is capable of producing information suitable for a variety of applications demanding three-dimensional in vivo velocity data.

Algorithms↗

Coupling pediatric ventricle assist devices to the Fontan circulation: simulations with a lumped-parameter model.

In pediatric ventricular assist device (VAD) design, the process of matching device characteristics and dimensions to the relevant disease conditions poses a formidable challenge because the disease spectrum is more highly varied than for adult applications. One example arises with single-ventricle congenital defects, which demand palliative surgeries that create elevated systemic venous pressure and altered pulmonary hemodynamics. Substituting a mechanical pump as a right ventricle has long been proposed to eliminate the associated early and postoperative anomalies. A pulsatile lumped-parameter model of the single-ventricle circulation was developed to guide the preliminary design studies. Two special modules, the pump characteristics and the total cavopulmonary connection (TCPC) module, are introduced. The TCPC module incorporates the results of three-dimensional patient-specific computational fluid dynamics calculations, where the pressure drop in the TCPC anastomosis is calculated at the equal vascular lung resistance operating point for different cardiac outputs at a steady 60/40 inferior vena cava/superior vena cava flow split. Preliminary results obtained with the adult parameters are presented with no ventricle remodeling or combined larger-size single ventricle. A detailed literature review of single-ventricle function is provided. Coupling a continuous pump to the single-ventricle circulation brought both the pulmonary and systemic venous pressures back to manageable levels. Selected VADs provided an acceptable cardiac output trace of the single left ventricle, after initial transients. Remodeling of the systemic venous compliance plays a critical role in performance and is included in this study. Pulsatile operation mode with rotational speed regulation highlighted the importance of TCPC and pulmonary artery compliances. Four different pumps and three patient-specific anatomical TCPC pathologies were studied. Magnitudes of the equivalent TCPC resistances were found to be comparable to the vascular resistances of the normal baseline circulation, significantly affecting both the VAD design and hemodynamics.

Anastomosis, Surgical↗