Accuracy of LED and halogen radiometers using different light sources.

PURPOSE: To determine the accuracy of commercially available, handheld light-emitting diode (LED) and halogen-based radiometers using LED and quartz-tungsten-halogen (QTH) curing lights with light guides of various diameters. METHODS: The irradiance of an LED curing light (L.E. Demetron 1, SDS/Kerr, Orange, CA, USA) and a QTH curing light (Optilux 501, SDS/Kerr) were measured using multiple units of an LED (Demetron L.E.D. Radiometer, SDS/Kerr) and a halogen radiometer (Demetron 100, SDS/Kerr) and compared with each other and to a laboratory-grade power meter (control). Measurements were made using five light guides with distal light guide diameters of 4, 7, 8, 10, and 12.5 mm. For each light guide, five readings were made with each of three radiometers of each radiometer type. Data were analyzed with two-way analysis of variance/Tukey; alpha = 0.05. RESULTS: In general, both handheld radiometer types exhibited significantly different irradiance readings compared with the control meter. Additionally, readings between radiometer types were found to differ slightly, but were correlated. In general, the LED radiometer provided slightly lower irradiance readings than the halogen radiometer, irrespective of light source. With both types of handheld radiometers, the use of the larger-diameter light guides tended to overestimate the irradiance values as seen in the control, while smaller-diameter light guides tended to underestimate. CLINICAL SIGNIFICANCE: The evaluated LED or halogen handheld radiometers may be used interchangeably to determine the irradiance of both LED and QTH visible-light-curing units. Measured differences between the two radiometer types were small and probably not clinically significant. However, the diameter of light guides may affect the accuracy of the radiometers, with larger-diameter light guides overestimating and smaller-diameter guides underestimating the irradiance value measured by the control instrument.

Analysis of Variance↗

Evaluation of field dental equipment in a deployment environment.

Dental officers and technicians must have reliable, durable, well-performing field dental equipment to enable them to provide dental care to deployed troops in operational environments. Unfortunately, no organized program exists to test such equipment before its purchase and use in the field. This article presents the results of a project conducted by the Naval Institute for Dental and Biomedical Research and the Air Force Dental Evaluation and Consultation Service to evaluate commercially available field dental equipment through laboratory testing and clinical-user evaluations in theater. The purpose of this 2-year project was to identify the best-performing and most cost-effective field dental equipment for possible future procurement. Initial laboratory testing was performed at the Naval Institute for Dental and Biomedical Research, and the equipment was then shipped to Kuwait for in-theater environmental and clinical-user testing. A seven-member scientific team of military dental officers and technicians was deployed for 1 month to perform in-theater testing under regional environmental conditions and to coordinate clinical-user evaluations. The testing provided beneficial results by identifying equipment that performed properly and equipment that exhibited shortcomings serious enough to render it inadequate for operational use. It is recommended that the project serve as a model for future testing and evaluation of medical/dental equipment by all of the military services.

Dental Equipment↗

Comparison of two video-imaging instruments for measuring volumetric shrinkage of dental resin composites.

OBJECTIVES: The purpose of this study was to measure the polymerization shrinkage of three dental resin composites using two commercially available video-imaging devices to determine if the devices produced equivalent results. METHODS: Small, semi-spherical specimens of a microhybrid (Venus), microfill (Filtek A110), and flowable (Esthet*X Flow) resin composite were manually formed and light activated for 40s using a light-curing unit. The volumetric polymerization shrinkage of fifteen specimens of each brand of resin composite was measured using the AcuVol and the Drop Shape Analysis System model DSA10 Mk2 (DSAS) video-imaging devices. Mean volumetric shrinkage values were calculated for each resin composite and equivalence was evaluated using the two one-sided tests approach. Differences between the means that were less than approximately 5% of the observed shrinkage were considered indicative of clinical equivalence. RESULTS: Mean volumetric shrinkage values measured for the resin composites were: Venus (AcuVol, 3.07+/-0.07%; DSAS, 2.90+/-0.07%); Filtek A110 (AcuVol, 2.26+/-0.10%; DSAS, 2.25+/-0.09%); and Esthet*X Flow (AcuVol, 5.01+/-0.17%; DSAS, 5.14+/-0.11%). Statistical analysis revealed that the two imaging devices produced equivalent results for Filtek A110 and Esthet*X Flow but not for Venus. CONCLUSIONS: Video-imaging systems provide an easy method for measuring volumetric shrinkage of resin composites. As with other methods for measuring volumetric shrinkage, however, they are best used to comparatively measure different materials within the same laboratory.

Acrylic Resins↗

Characteristics of infection control programs in U.S. Air Force dental clinics: a survey.

BACKGROUND: National organizations and regulatory agencies have issued a number of guidelines on proper infection control procedures in dentistry. The objective of the authors' research was to gather information about current infection control practices in U.S. Air Force (USAF) Dental Corps clinics for the purpose of updating previously issued guidelines and developing infection control training programs. METHODS: The authors mailed a 60-item self-administered survey to the commanders of all USAF dental clinics located in the United States and overseas (n=82). The survey used primarily fixed-response questions to gather information about aspects of the clinics' infection control programs. The authors obtained descriptive statistics of the returned data by means of a statistical software package. RESULTS: The results indicated a high degree of compliance with existing USAF dental infection control guidelines. All clinics had personnel assigned to manage their programs, had a written exposure control plan and took measures to improve dental unit water quality. Facilities used a number of approaches to achieve and monitor compliance and exhibited a considerable amount of variation in infection control procedures when specific guidelines did not exist. CONCLUSIONS: In general, USAF dental clinics reported high levels of compliance with current infection control policies and procedures. Recurrent training, continual oversight, a highly motivated staff and teamwork are essential for reaching and maintaining these levels. Clinical Implications. Although compliance with recommended infection control guidelines is challenging, the results of this survey indicate that compliance is achievable, even in large group practices.

Dental Clinics↗

The effect of a translucent post on resin composite depth of cure.

OBJECTIVE: To evaluate the effect of a light-transmitting post on the depth of cure of a resin composite. METHODS: Acetate resin molds were filled with resin composite in which a light-transmitting post was inserted into the center and photopolymerized to the manufacturer's recommendations. Identical molds without a light-transmitting post were photopolymerized in a similar matter and served as a control. Molds were sectioned on a water-cooled, diamond saw at prescribed distances and the depth of cure was determined using a Knoop Hardness bottom-to-top ratio criterion. Data within each group were analyzed using 2-way (depth-by-distance) repeated measure ANOVA. Between-group contrasts (post versus no post) were accessed by a 3-way (2 within-subjects and 1 between-subjects) ANOVA with critical p = 0.05. RESULTS: The presence of the post did increase (p < 0.001) Knoop Hardness values in simulated apical regions as compared to a control. However, there was no difference in the depth of cure between the groups (3-way analysis p = 0.2) and also when evaluated using an 80% bottom-to-top Knoop Hardness ratio. SIGNIFICANCE: The results suggest that these posts may have a limited utility when judged against a Knoop Hardness ratio criterion.

Analysis of Variance↗

Statistical estimation of resin composite polymerization sufficiency using microhardness.

With respect to determining sub-surface resin polymerization sufficiency, this study compared a traditional method of applying linear regression to bottom- to top-surface Knoop hardness ratios to an alternative method based on nonlinear regression. Inverse linear regression on ratios was used to estimate the exposure duration required for 80% bottom-surface hardness with respect to the top, in six light-by-material groups. Alternatively, a one-phase, two-parameter, exponential association of the form Y=Y(max)(1-e(-kt)) (where Y(max) is maximum hardness, k is a rate constant, and t is exposure duration), was used to model hardness. Inverse nonlinear regression estimated, for each condition, the exposure duration required for the bottom surface to achieve 80% of corresponding condition (light and material) top-surface Y(max). Mathematically, analysis of ratios was demonstrated to yield potentially less precise and biased estimates. Nonlinear regression yielded better statistical fit and provided easily accessible tests for differences in k across light-system groups. Another recently proposed nonlinear model for polymerization, Y=Y(max)kt(n)/(1+kt(n)), was also considered. While this new model has substantially greater phenomenological and mechanistic justification, we found that the model-fitting process was more sensitive to initial parameter values and sometimes yielded untenable results when applied to our data. However, we believe that these problems would not occur if sample points are well distributed across a wide range of exposure durations, and that the model, Y=Y(max)kt(n)/(1+kt(n)), should be considered for such data sets.

Analysis of Variance↗

Polymerization efficiency of LED curing lights.

PURPOSE: The purpose of this study was to compare the curing efficiency of three commercially available light-emitting diode (LED)-based curing lights with that of a quartz tungsten halogen (QTH) curing light by means of hardness testing. In addition, the power density (intensity) and spectral emission of each LED light was compared with the QTH curing light in both the 380- to 520-nm and the 450- to 500-nm spectral ranges. MATERIALS AND METHODS: A polytetrafluoroethylene mold 2 mm high and 8 mm in diameter was used to prepare five depth-of-cure test specimens for each combination of exposure duration, composite type (Silux Plus [microfill], Z-100 [hybrid]), and curing light (ZAP Dual Curing Light, LumaCure, VersaLux, Optilux 401). After 24 hours, Knoop hardness measurements were made for each side of the specimen, means were calculated, and a bottom/top Knoop hardness (B/T KH) percentage was determined. A value of at least 80% was used to indicate satisfactory polymerization. A linear regression of B/T KH percentage versus exposure duration was performed, and the resulting equation was used to predict the exposure duration required to produce a B/T KH percentage of 80% for the test conditions. The power densities (power/unit area) of the LED curing lights and the QTH curing light (Optilux 401) were measured 1 mm from the target using a laboratory-grade, laser power meter in both the full visible light spectrum range (380-780 nm) and the spectral range (between 450 and 500 nm), using a combination of long- and short-wave edge filters. RESULTS: The emission spectra of the LED lights more closely mirrored the absorption spectrum of the commonly used photoinitiator camphorquinone. Specifically, 95% of the emission spectrum of the VersaLux, 87% of the LumaCure, 84% of the ZAP LED, and 78% of the ZAP combination LED and QTH fell between 450 and 500 nm. In contrast, only 56% of the emission spectrum of the Optilux 401 halogen lamp fell within this range. However, the power density between 450 and 500 nm was at least four times greater for the halogen lamp than for the purely LED lights. As a result, the LED-based curing lights required from 39 to 61 seconds to cure a 2-mm thick hybrid resin composite and between 83 and 131 seconds to adequately cure a microfill resin composite. By comparison, the QTH light required only 21 and 42 seconds to cure the hybrid and microfill resin composites, respectively. CLINICAL SIGNIFICANCE: The first-generation LED-based curing lights in this study required considerably longer exposure durations than the QTH curing light to adequately polymerize a hybrid and a microfill resin composite.

Composite Resins↗

Thermal emission and curing efficiency of LED and halogen curing lights.

The purpose of this study was to compare the thermal emission and curing efficiency of LED (LEDemetron 1, SDS/Kerr) and QTH (VIP, BISCO) curing lights at maximum output and similar power, power density and energy density using the same light guide. Also, another LED curing light (Allegro, Den-Mat) and the QTH light at reduced power density were tested for comparison. Increase in temperature from the tips of the light guides was measured at 0 and 5 mm in air (23 degrees C) using a temperature probe (Fluke Corp). Pulpal temperature increase was measured using a digital thermometer (Omega Co) and a K-type thermocouple placed on the central pulpal roof of human molars with a Class I occlusal preparation. Measurements were made over 90 seconds with an initial light activation of 40 seconds. To test curing efficiency, resin composites (Z100, A110, 3M/ESPE) were placed in a 2-mm deep and 8-mm wide plastic mold and cured with the LED and QTH curing lights at 1- and 5-mm curing distances. Knoop Hardness Numbers (KHN) were determiped on the top and bottom surfaces (Leco). Bottom hardness values were expressed as a percentage of maximum top hardness. No significant differences were found in maximum thermal emission or KHN ratios between the LED (LEDemetron 1) and the QTH (VIP) at maximum output and similar energy densities (ANOVA/Tukey's; alpha=0.05).

Body Temperature↗

Effect of handpiece maintenance method on bond strength.

This study evaluated the effect of dental handpiece lubricant on the shear bond strength of three bonding agents to dentin. A lubrication-free handpiece (one that does not require the user to lubricate it) and a handpiece requiring routine lubrication were used in the study. In addition, two different handpiece lubrication methods (automated versus manual application) were also investigated. One hundred and eighty extracted human teeth were ground to expose flat dentin surfaces that were then finished with wet silicon carbide paper. The teeth were randomly divided into 18 groups (n=10). The dentin surface of each specimen was exposed for 30 seconds to water spray from either a lubrication-free handpiece or a lubricated handpiece. Prior to exposure, various lubrication regimens were used on the handpieces that required lubrication. The dentin surfaces were then treated with total-etch, two-step; a self-etch, two-step or a self-etch, one-step bonding agent. Resin composite cylinders were bonded to dentin, the specimens were then thermocycled and tested to failure in shear at seven days. Mean bond strength data were analyzed using Dunnett's multiple comparison test at an 0.05 level of significance. Results indicated that within each of the bonding agents, there were no significant differences in bond strength between the control group and the treatment groups regardless of the type of handpiece or use of routine lubrication.

Acid Etching, Dental↗

Volumetric polymerization shrinkage of resin composites under simulated intraoral temperature and humidity conditions.

This study measured the volumetric shrinkage of resin composites polymerized under temperature and humidity conditions simulating the oral cavity and compared them to those occurring under ambient room conditions. Small, semispherical specimens of a microhybrid (Z100), microfill (Filtek A110) and flowable microhybrid (4 Seasons Flow) resin composite were manually formed and light activated for 40 seconds using a halogen light-curing unit (Spectrum Curing Light). The volumetric polymerization shrinkage of 10 specimens of each brand of resin composite was measured using a drop shape analysis unit (Drop Shape Analysis System, model DSA10 Mk2) under each of two temperature/relative humidity conditions: room conditions (22 +/- 2 degrees C and 60 +/- 5%) and those simulating intraoral conditions (35 degrees C and 92 +/- 5%). Mean volumetric shrinkage values were calculated for each resin composite and the data were analyzed using two-way analysis of variance and t-test (a=0.05) to determine if significant differences existed between the amount of volumetric polymerization shrinkage that occurred under ambient room conditions and that which occurred under simulated intraoral conditions. Mean volumetric shrinkage values measured for the resin composites were: 2.26 +/- 0.04% (ambient) and 2.61 +/- 0.04% (intraoral) for Z100; 1.96 +/- 0.04% (ambient) and 2.28 +/- 0.04% (intraoral) for Filtek A110 and 4.53 +/- 0.06% (ambient) and 5.34 +/- 0.05% (intraoral) for 4 Seasons Flow. For each resin composite, statistical analysis indicated that the amount of volumetric shrinkage measured under simulated intraoral conditions was significantly greater than what was measured under ambient room conditions (p<0.0001).

Body Temperature↗

Effect of humidity on the volumetric polymerization shrinkage of resin restorative materials.

This study measured the volumetric polymerization shrinkage of three resin restorative materials under ambient (that is, room) relative humidity conditions and compared it with shrinkage occurring under a higher humidity condition that simulated the oral cavity. Small, semi-spherical specimens of a compomer, microfill composite, and flowable microhybrid composite were formed and light-activated using a halogen photocuring unit. The volumetric polymerization shrinkage of 15 specimens of each product was measured using a drop shape analysis unit for the relative humidity level of the ambient room (58.6 +/- 5.9%) and a higher humidity level that simulated the oral cavity (98.0 +/- 2.9%). Mean volumetric shrinkage values were calculated for each resin composite and the data were analyzed using a two-way analysis of variance (alpha = 0.05) to determine if significant differences existed between the amount of volumetric polymerization shrinkage that occurred under ambient room humidity conditions and the amount that occurred under simulated intraoral humidity conditions. Statistical analysis indicated that there was no significant difference (p = 0.17).

Compomers↗