PubMed Health⌕ Search

Biomedical subjects

David G Norris

Publications and source records attributed to David G Norris.

At least 19 recordsLinked to original sources

Principles of magnetic resonance assessment of brain function.

MRI has advanced to being one of the major tools for the assessment of brain function. This review article examines the basic principles that underpin these measurements. The main emphasis is on the characteristics and detection of blood oxygen level dependent (BOLD) contrast. In the first part of the article the relationship between BOLD, blood flow, blood oxygen, and the rate of metabolic consumption of oxygen is described. The four contrast mechanisms that contribute to the BOLD signal change, namely extravascular static and dynamic dephasing, intravascular T2-like changes, and the intravascular frequency offset effect are described in terms of their spatial localization and relative contributions to the BOLD signal. The current model of changes in blood flow being an indirect consequence of synaptic input to a region is presented. The second section of the article deals with the imaging characteristics of BOLD in terms of the attainable spatial resolution and linear system characteristics. In the third section, practical BOLD imaging is examined for choice of pulse sequence, resolution, echo time (TE), repetition time (TR), and flip angle. The final section touches on other MRI approaches that are relevant to cognitive neuroimaging, in particular the measurement of blood flow, blood volume, resting state fluctuations in the BOLD signal, and measures of connectivity using diffusion tensor imaging and fiber-tracking.

Algorithms↗

BOLD contrast sensitivity enhancement and artifact reduction with multiecho EPI: parallel-acquired inhomogeneity-desensitized fMRI.

Functional MRI (fMRI) generally employs gradient-echo echo-planar imaging (GE-EPI) to measure blood oxygen level-dependent (BOLD) signal changes that result from changes in tissue relaxation time T(*) (2) between activation and rest. Since T(*) (2) strongly varies across the brain and BOLD contrast is maximal only where the echo time (TE) equals the local T(*) (2), imaging at a single TE is a compromise in terms of overall sensitivity. Furthermore, the long echo train makes EPI very sensitive to main field inhomogeneities, causing strong image distortion. A method is presented that uses accelerated parallel imaging to reduce image artifacts and acquire images at multiple TEs following a single excitation, with no need to increase TR. Sensitivity gains from the broadened T(*) (2) coverage are optimized by pixelwise weighted echo summation based on local T(*) (2) or contrast-to-noise ratio (CNR) measurements. The method was evaluated using an approach that allows differential BOLD CNR to be calculated without stimulation, as well as with a Stroop experiment. Results obtained at 3 T showed that BOLD sensitivity improved by 11% or more in all brain regions, with larger gains in areas typically affected by strong susceptibility artifacts. The use of parallel imaging markedly reduces image distortion, and hence the method should find widespread application in functional brain imaging.

Adult↗

Combining EEG and fMRI to investigate the post-movement beta rebound.

The relationship between synchronous neuronal activity as measured with EEG and the blood oxygenation level dependent (BOLD) signal as measured during fMRI is not clear. This work investigates the relationship by combining EEG and fMRI measures of the strong increase in beta frequency power following movement, the so-called post-movement beta rebound (PMBR). The time course of the PMBR, as measured by EEG, was included as a regressor in the fMRI analysis, allowing identification of a region of associated BOLD signal increase in the sensorimotor cortex, with the most significant region in the post-central sulcus. The increase in the BOLD signal suggests that the number of active neurons and/or their synaptic rate is increased during the PMBR. The duration of the BOLD response curve in the PMBR region is significantly longer than in the activated motor region, and is well fitted by a model including both motor and PMBR regressors. An intersubject correlation between the BOLD signal amplitude associated with the PMBR regressor and the PMBR strength as measured with EEG provides further evidence that this region is a source of the PMBR. There is a strong intra-subject correlation between the BOLD signal amplitude in the sensorimotor cortex during movement and the PMBR strength as measured by EEG, suggesting either that the motor activity itself, or somatosensory inputs associated with the motor activity, influence the PMBR. This work provides further evidence for a BOLD signal change associated with changes in neuronal synchrony, so opening up the possibility of studying other event-related oscillatory changes using fMRI.

Adult↗

Is there a change in water proton density associated with functional magnetic resonance imaging?

In a recent series of studies (see, for example, Stroman et al. Magn Reson Imag 2001; 19:827-831), an increase of water proton density has been suggested to correlate with neuronal activity. Owing to the significant implications of such a mechanism for other functional experiments, the functional signal changes in humans at very short echo times were re-examined by spin-echo EPI at 3 T. The results do not confirm the previous hypothesis of a significant increase in extravascular proton density at TE = 0. Instead, an alternative explanation of the effect is offered: The use of a low threshold to identify activated voxels may generate an artificial offset in functional contrast due to the inclusion of false-positives in the analysis.

Adult↗

Improving the amplitude-modulated control experiment for multislice continuous arterial spin labeling.

The use of an amplitude-modulated radiofrequency (RF) pulse for a control experiment is a proven method to control for off-resonance effects in multislice continuous arterial spin labeling (CASL) experiments. This method is also known as double adiabatic inversion. The adiabaticity factor of a single half-pulse, beta(1/2), and a new dimensionless parameter alpha, which is obtained from the labeling parameters and the flow velocity, are introduced. This makes it possible to distinguish three distinct cases: 1) With low alpha, a double inversion occurs. 2) With alpha > or = approximately 4, the efficiency with which the longitudinal magnetization is returned to the z-axis depends on the phase of the amplitude modulation at the time the spins cross the center of the labeling plane. 3) In the intermediate region, the efficiency shows undesirable fluctuations. In a Bloch equation simulation, three optimized parameter sets are determined. Near ideal performance should always be achieved by combinations of parameters for which beta(1/2) > or = approximately 2 and alpha approximately pi/beta(1/2). The efficiency increases were realized in a volunteer study, showing the practical application of the suggested optimization.

Adult↗

Continuous artery-selective spin labeling (CASSL).

A new technique for selective spin labeling of individual arteries is presented. It is based on continuous arterial spin labeling (CASL) with an amplitude-modulated control experiment. Precessionary motion of the labeling gradient about the axis of the artery, combined with an appropriate frequency modulation of the labeling RF pulse, restricts the adiabatic inversion to the desired artery. In phantom studies, it was found that the level of selectivity could be controlled by the sequence parameters, and that the achievable labeling efficiency was at a level of approximately 80% compared to a regular, nonselective CASL experiment. In a volunteer study we acquired high-quality images of the perfusion territories of the internal carotid artery (ICA), the basilar artery (BA), the middle cerebral artery (MCA), and both anterior cerebral arteries (ACAs). The results show the method's flexibility for different geometries and flow velocities. Potential applications include perfusion territory imaging of smaller cerebral arteries, and selective angiography techniques.

Adult↗

Quantifying the spatial resolution of the gradient echo and spin echo BOLD response at 3 Tesla.

The blood oxygen level dependent (BOLD) response, as measured with fMRI, offers good spatial resolution compared to other non-invasive neuroimaging methods. The use of a spin echo technique rather than the conventional gradient echo technique may further improve the resolution by refocusing static dephasing effects around the larger vessels, so sensitizing the signal to the microvasculature. In this work the width of the point spread function (PSF) of the BOLD response at a field strength of 3 Tesla is compared for these two approaches. A double echo EPI pulse sequence with simultaneous collection of gradient echo and spin echo signal allows a direct comparison of the techniques. Rotating multiple-wedge stimuli of different spatial frequencies are used to estimate the width of the BOLD response. Waves of activation are created on the surface of the visual cortex, which begin to overlap as the wedge separation decreases. The modulation of the BOLD response decreases with increasing spatial frequency in a manner dependent on its width. The spin echo response shows a 13% reduction in the width of the PSF, but at a cost of at least 3-fold reduction in contrast to noise ratio.

Adult↗

Continuous arterial spin labeling at the human common carotid artery: the influence of transit times.

In evaluating the sensitivity of arterial spin labeling (CASL) and for quantification of perfusion, knowledge of the transit time from the labeling plane to the imaging slice is crucial. The purpose of the current study was to obtain estimates of transit times relevant under the specific experimental conditions of CASL in human subjects using a separate local labeling coil at the neck. Specifically, the post-label delay (PLD), i.e. the time between the end of the labeling period and the image acquisition, was varied either with or without additional application of crusher gradients to suppress intravascular signal contributions. The overall sensitivity change for varying the PLD between 1000 and 1700 ms was low. A tissue transit time from the neck to an axial supraventricular section through Broca's knee was obtained by fitting the PLD dependence to a two-compartment model. Averaging over subjects yielded 1930 +/- 110 ms for the tissue transit time, and 73 +/- 5 ml min(-1) 100 g(-1) for the cerebral blood flow. Small areas that exhibited a very high signal change upon labeling were indicative of regional variation in cerebral blood flow related to vascular anatomy.

Adult↗

A comparison of signal instability in 2D and 3D EPI resting-state fMRI.

Spatiotemporally structured noise, such as physiological noise, is a potential source of artifacts in functional magnetic resonance imaging (fMRI) and is the main limiting factor for the detection of small blood oxygen level-dependent (BOLD) signal variations. fMRI was employed to detect low-frequency BOLD signal fluctuations, which are thought to be related to spontaneous neuronal activity in the resting human brain. The sensitivity to noise, that is, signal variations of non-BOLD origin, was investigated for two- (2D) and three-dimensional (3D) imaging techniques. Incomplete relaxation between subsequent scans increases the level of temporally and spatially correlated signal variations originating from physiological and/or systemic noise. Although inflow effects are suspected to be reduced in 3D echo-planar imaging (EPI) compared with multi-slice 2D EPI, the noise level was higher in the 3D technique. The noise level in 3D fMRI experiments was significantly increased by instabilities of the transverse steady-state magnetization as the repetition time was of the order of T(2). By implementing radiofrequency spoiling, temporal signal fluctuations and erroneous inter-regional correlation in connectivity maps were diminished to a level present in data sets acquired with 2D EPI.

Adult↗

Efficiency of flow-driven adiabatic spin inversion under realistic experimental conditions: a computer simulation.

Continuous arterial spin labeling (CASL) using adiabatic inversion is a widely used approach for perfusion imaging. For the quantification of perfusion, a reliable determination of the labeling efficiency is required. A numerical method for predicting the labeling efficiency in CASL experiments under various experimental conditions, including spin relaxation, is demonstrated. The approach is especially useful in the case of labeling at the carotid artery with a surface coil, as consideration of the experimental or theoretical profile of the B(1) field is straightforward. Other effects that are also accounted for include deviations from a constant labeling gradient, and variations in the blood flow velocity due to the cardiac cycle. Assuming relevant experimental and physiological conditions, maximum inversion efficiencies of about 85% can be obtained.

Blood Flow Velocity↗

Quantifying the intra- and extravascular contributions to spin-echo fMRI at 3 T.

Functional MRI (fMRI) by means of spin-echo (SE) techniques provides an interesting alternative to gradient-echo methods because the contrast is based primarily on dynamic averaging associated with the blood oxygenation level-dependent (BOLD) effect. In this article the contributions from different brain compartments to BOLD signal changes in SE echo planar imaging (EPI) are investigated. To gain a better understanding of the underlying mechanisms that cause the fMRI contrast, two experiments are presented: First, the intravascular contribution is decomposed into two fractions with different regimes of flow by means of diffusion-weighting gradient schemes which are either flow-compensated, or will maximally dephase moving spins. Second, contributions from the intra- and extravascular space are selectively suppressed by combining flow-weighting with additional refocusing pulses. The results indicate two qualitatively different components of flowing blood which contribute to the BOLD contrast and a nearly equal share in functional signal from the intra- and extravascular compartments at TE approximately 80 ms and 3 T. Combining these results, there is evidence that at least one-half of the functional signal originates from the parenchyma in SE fMRI at 3 T. The authors suggest the use of flow-compensated diffusion weighting for SE fMRI to improve the sensitivity to the parenchyma.

Blood Flow Velocity↗

Reduced BOLD response to periodic visual stimulation.

The blood oxygenation level-dependent (BOLD) response to entrained neuronal firing in the human visual cortex and lateral geniculate nuclei was investigated. Periodic checkerboard flashes at a range of frequencies (4-20 Hz) were used to drive the visual cortex neurons into entrained oscillatory firing. This is compared to a checkerboard flashing aperiodically, with the same average number of flashes per unit time. A magnetoencephalography (MEG) measurement was made to confirm that the periodic paradigm elicited entrainment. We found that for frequencies of 10 and 15 Hz, the periodic stimulus gave a smaller BOLD response than for the aperiodic stimulus. Detailed investigation at 15 Hz showed that the aperiodic stimulus gave a similar BOLD increase regardless of the magnitude of jitter (+/-17 ms compared to +/-33 ms), indicating that flashes need to be precise to at least 17 ms to maintain entrainment. This is also evidence that for aperiodic stimuli, the amplitude of the BOLD response ordinarily reflects the total number of flashes per unit time, irrespective of the precise spacing between them, suggesting that entrainment is the main cause of the BOLD reduction in the periodic condition. The results indicate that, during entrainment, there is a reduction in the neuronal metabolic demand. We suggest that because of the selective frequency band of this effect, it could be connected to synchronised reverberations around an internal feedback loop.

Adult↗

Advances in high-field magnetic resonance imaging.

Among advances in magnetic resonance imaging (MRI), the increase of the magnetic field strength is perhaps one of the most significant. The use of high magnetic fields for in vivo magnetic resonance is motivated by a number of considerations. Advantages are increases in signal-to-noise ratio, blood-oxygenation level-dependent contrast, and spectral resolution, while disadvantages include potential reduction of contrast in anatomic imaging owing to lengthening of T1 and effects of susceptibility of high fields. To address these challenges, technical advances have been made in various aspects of MRI, allowing high-field MRI to provide exquisite morphological and functional details in clinical and research settings. This review provides an overview of technical issues and applications of high-field MRI.

Animals↗

High field human imaging.

This review article examines the state of knowledge regarding human imaging using MRI at high main magnetic field strengths. The article starts with a summary of the technical issues associated with magnetic field strengths in the range of 3-8 T, including magnet characteristics and the properties of radiofrequency magnetic fields, with special reference to sensitivity, power deposition, and homogeneity. The published data on tissue-water relaxation times in the brain is tabulated and the implications for contrast and pulse sequence implementation is elucidated. The behavior of the major fast imaging sequences, fast low angle shot (FLASH), rapid acquisition with relaxation enhancement (RARE), and echo planar imaging (EPI), is examined in this context. A number of anatomical images from 3 T systems are presented as examples. Particular attention is given to various forms of vascular imaging, namely, time of flight angiography, venography, and arterial spin labeling. The most complex changes in contrast with main magnetic field strength are in activation studies utilizing the blood oxygen level dependent mechanism, which are examined in detail. Improvements in spatial specificity are emphasized, particularly in conjunction with spin-echo imaging. The article concludes with a discussion of the current status and the potential impact of technical developments such as parallel imaging.

Brain↗

Functional perfusion imaging using continuous arterial spin labeling with separate labeling and imaging coils at 3 T.

Functional perfusion imaging with a separate labeling coil located above the common carotid artery was demonstrated in human volunteers at 3 T. A helmet resonator and a spin-echo echo-planar imaging (EPI) sequence were used for imaging, and a circular surface coil of 6 cm i.d. was employed for labeling. The subjects performed a finger-tapping task. Signal differences between the condition of finger tapping and the resting state were between -0.5% and -1.1 % among the subjects. The imaging protocol included a long post-label delay (PLD) to reduce transit time effects. Labeling was applied for all repetitions of the functional run to reduce the sampling interval.

Adult↗

Determination of cerebrovascular reactivity by means of FMRI signal changes in cerebral microangiopathy: a correlation with morphological abnormalities.

BACKGROUND AND PURPOSE: A reduced cerebrovascular reactivity (CR) is a risk factor of cerebrovascular disease. In this study, we implemented a protocol to assess CR by means of functional MRI (fMRI) using hyperventilation. SUBJECTS AND METHODS: In 5 patients with cerebral microangiopathy (CM/lacunar infarction and white matter degeneration), 6 healthy elderly subjects (age-matched control), and 6 young healthy subjects, the CR in response to hyperventilation was evaluated by fMRI using gradient echo-planar Imaging. The percentage signal change normalized by end-tidal CO(2) value was measured in various brain regions. RESULTS: All subjects performed hyperventilation well without adverse reaction and significant gross motion. Patients with CM showed significant qualitative and quantitative differences (p < 0.05) as compared to controls. The volume of gray matter showing significant CR was significantly reduced in patients: by 40% in comparison to the age-matched elderly control group and by 60% when compared with the young controls. The CR impairment was most pronounced in the frontal cortices with a drastically reduced magnitude of the magnetic resonance (MR) signal change in the patients (-0.62 +/- 0.2% in patients versus -2.0 +/- 0.36% in age-matched controls, p < 0.0001). A strong relation was evident between the fMRI-based CR reduction in patients with CM and the individual severity of structural MR abnormalities (p = 0.002). CONCLUSION: This study demonstrates that fMRI-based signal changes in response to hyperventilation reliably reflect cerebral vasoreactivity. The protocol is feasible in healthy young and elderly controls and patients with CM. Quantitative and qualitative assessment of the signal decrease in the T(2)-weighted MR sequence and coregistration with individual anatomical data allow the generation of an individual cerebral vasoreactivity map. Future research will address the effect of CR reduction on neuropsychological parameters in patients with CM.

Adult↗

Regional differences of fMR signal changes induced by hyperventilation: comparison between SE-EPI and GE-EPI at 3-T.

PURPOSE: To evaluate whether reproducible signal change of brain tissues by hyperventilation (HV) can be seen on spin-echo (SE)-echo planar imaging (EPI) at 3-T and to examine the sensitivity of SE-EPI for measuring vascular reactivity in regions of the brain, such as the hippocampal formation, that are difficult to visualize with gradient-echo (GE)-EPI due to susceptibility artifacts. MATERIALS AND METHODS: Six healthy human subjects performed a voluntary HV task. The task design was as follows: two minutes normal breathing (rest) followed by two minutes HV, giving a basic four-minute block that was repeated three times for a total scan time of 12 minutes for one run. Each subject performed the run both for SE-EPI and GE-EPI. Statistical analysis was performed to detect the area with significant cerebrovascular reactivity. The percentage signal change was also obtained for each cerebral region. RESULTS: Both GE-EPI and SE-EPI showed globally significant signal decreases in the cerebral cortex. In GE-EPI, the frontal cortex showed a larger signal decrease than the other gray matter tissues (P < 0.05). In SE-EPI, the differences among gray matter tissues except for the hippocampal formation were not significant. The hippocampal formation showed the largest signal change (P < 0.05) in SE-EPI, but no significant signal change was observed in GE-EPI due to the presence of susceptibility artifacts. CONCLUSION: HV using SE-EPI at 3-T provides robust and reproducible signal decreases and may make the evaluation of the vascular reactivity in hippocampal formation feasible.

Adult↗

Characterization of cerebral microangiopathy using 3 Tesla MRI: correlation with neurological impairment and vascular risk factors.

PURPOSE: To investigate whether clinical and neuropsychological impairment in cerebral small-vessel disease (CSVD) can be evaluated by means of morphological magnetic resonance imaging (MRI). MATERIALS AND METHODS: MRI at 3 Tesla in T2- and T1-weighted sequences was evaluated in 44 patients with cerebral microangiopathy, and 30 patients with combined cerebral micro- and macroangiopathy. The MR characteristics were correlated to clinical data, attentional impairment, and the patients' individual vascular risk factor profiles. Fifteen healthy age-matched control subjects participated in the study to assess MR signal changes in nonhypertensive elderly subjects. RESULTS: Patients and normal controls differed significantly in the extent of MR signal changes. A close relation between age, obesity, hypertension, and MR signal abnormalities was evident in all patients. Patients with pure CSVD additionally showed an association between their MR-defined severity of disease and their degree of neurological impairment, and their vascular risk score. In contrast, attentional impairment did not relate to the MR-defined severity of CSVD. CONCLUSION: MR signal changes in CSVD show a close relationship to some risk factors of individual patients.

Analysis of Variance↗