Self-calibrating 3D-ultrasound-based bone registration for minimally invasive orthopedic surgery.

Intraoperative freehand three-dimensional (3-D) ultrasound (3D-US) has been proposed as a noninvasive method for registering bones to a preoperative computed tomography image or computer-generated bone model during computer-aided orthopedic surgery (CAOS). In this technique, an US probe is tracked by a 3-D position sensor and acts as a percutaneous device for localizing the bone surface. However, variations in the acoustic properties of soft tissue, such as the average speed of sound, can introduce significant errors in the bone depth estimated from US images, which limits registration accuracy. We describe a new self-calibrating approach to US-based bone registration that addresses this problem, and demonstrate its application within a standard registration scheme. Using realistic US image data acquired from 6 femurs and 3 pelves of intact human cadavers, and accurate Gold Standard registration transformations calculated using bone-implanted fiducial markers, we show that self-calibrating registration is significantly more accurate than a standard method, yielding an average root mean squared target registration error of 1.6 mm. We conclude that self-calibrating registration results in significant improvements in registration accuracy for CAOS applications over conventional approaches where calibration parameters of the 3D-US system remain fixed to values determined using a preoperative phantom-based calibration.

Algorithms↗

Factors influencing the accuracy of biomechanical breast models.

Recently it has been suggested that finite element methods could be used to predict breast deformations in a number of applications, including comparison of multimodality images, validation of image registration and image guided interventions. Unfortunately knowledge of the mechanical properties of breast tissues is limited. This study evaluated the accuracy with which biomechanical breast models based on finite element methods can predict the displacements of tissue within the breast in the practical clinical situation where the boundaries of the organ might be known reasonably accurately but there is some uncertainty on the mechanical properties of the tissue. For two datasets, we investigate the influence of tissue elasticity values, Poisson's ratios, boundary conditions, finite element solvers and mesh resolutions. Magnetic resonance images were acquired before and after compressing each volunteer's breast by about 20%. Surface displacement boundary conditions were derived from a three-dimensional nonrigid image registration. Six linear and three nonlinear elastic material models with and without skin were tested. These were compared to hyperelastic models. The accuracy of the models was evaluated by assessing the ability of the model to predict the location of 12 corresponding anatomical landmarks. The accuracy was most sensitive to the Poisson's ratio and the boundary condition. Best results were achieved for accurate boundary conditions, appropriate Poisson's ratios and models where fibroglandular tissue was at most four times stiffer than fatty tissue. These configurations reduced the mean (maximum) distance of the landmarks from 6.6 mm (12.4 mm) to 2.1 mm (3.4 mm) averaged over all experiments.

Algorithms↗

A continuous 4D motion model from multiple respiratory cycles for use in lung radiotherapy.

Respiratory motion causes errors when planning and delivering radiotherapy treatment to lung cancer patients. To reduce these errors, methods of acquiring and using four-dimensional computed tomography (4DCT) datasets have been developed. We have developed a novel method of constructing computational motion models from 4DCT. The motion models attempt to describe an average respiratory cycle, which reduces the effects of variation between different cycles. They require substantially less memory than a 4DCT dataset, are continuous in space and time, and facilitate automatic target propagation and combining of doses over the respiratory cycle. The motion models are constructed from CT data acquired in cine mode while the patient is free breathing (free breathing CT - FBCT). A "slab" of data is acquired at each couch position, with 3-4 contiguous slabs being acquired per patient. For each slab a sequence of 20 or 30 volumes was acquired over 20 seconds. A respiratory signal is simultaneously recorded in order to calculate the position in the respiratory cycle for each FBCT. Additionally, a high quality reference CT volume is acquired at breath hold. The reference volume is nonrigidly registered to each of the FBCT volumes. A motion model is then constructed for each slab by temporally fitting the nonrigid registration results. The value of each of the registration parameters is related to the position in the respiratory cycle by fitting an approximating B spline to the registration results. As an approximating function is used, and the data is acquired over several respiratory cycles, the function should model an average respiratory cycle. This can then be used to calculate the value of each degree of freedom at any desired position in the respiratory cycle. The resulting nonrigid transformation will deform the reference volume to predict the contents of the slab at the desired position in the respiratory cycle. The slab model predictions are then concatenated to produce a combined prediction over the entire region of interest. We have performed a number of experiments to assess the accuracy of the nonrigid registration results and the motion model predictions. The individual slab models were evaluated by expert visual assessment and the tracking of easily identifiable anatomical points. The combined models were evaluated by calculating the discontinuities between the transformations at the slab boundaries. The experiments were performed on five patients with a total of 18 slabs between them. For the point tracking experiments, the mean distance between where a clinician manually identified a point and where the registration results located the point, the target registration error (TRE), was 1.3 mm. The mean distance between a manually identified point and the models prediction of the point's location, the target model error (TME), was 1.6 mm. The mean discontinuity between model predictions at the slab boundaries, the Continuity Error, was 2.2 mm. The results show that the motion models perform with a level of accuracy comparable to the slice thickness of 1.5 mm.

Artifacts↗

Lipid membrane; a novel target for viral and bacterial pathogens.

Lipid rafts are defined as specialized, dynamic microdomains that can be found in plasma membrane, and they are enriched with cholesterol and sphingolipids. Since lipid rafts' first debut in the mid 1990's, their existence, function and biological relevance have been a subject of intense scrutiny within the scientific community. Throughout this debate, we have learned a great deal regarding how cargos (both pathogens and cellular factors) are transported into and out of the cell through raft-dependent or raft-independent pathways. It is now apparent that a number of toxins, bacterial-, and viral-pathogens are able to exploit cholesterol and/or lipid rafts to gain a foot hold in their target hosts. The objective of this review is to describe our current appreciation on how selected pathogens utilise cholesterol and/or lipid rafts to support their propagation and to speculate on how some of these observations can be explored for the development of novel strategies that target plasma membrane lipids to control the spread of these viral- and bacterial-pathogens.

Animals↗

Application of soft tissue modelling to image-guided surgery.

The deformation of soft tissue compromises the accuracy of image-guided surgery based on preoperative images, and restricts its applicability to surgery on or near bony structures. One way to overcome these limitations is to combine biomechanical models with sparse intraoperative data, in order to realistically warp the preoperative image to match the surgical situation. We detail the process of biomechanical modelling in the context of image-guided surgery. We focus in particular on the finite element method, which is shown to be a promising approach, and review the constitutive relationships which have been suggested for representing tissue during surgery. Appropriate intraoperative measurements are required to constrain the deformation, and we discuss the potential of the modalities which have been applied to this task. This technology is on the verge of transition into clinical practice, where it promises to increase the guidance accuracy and facilitate less invasive interventions. We describe here how soft tissue modelling techniques have been applied to image-guided surgery applications.

Algorithms↗

Self-calibrating ultrasound-to-CT bone registration.

We describe a new self-calibrating approach to rigid registration of 3D ultrasound images in which in vivo data acquired for registration are used to simultaneously perform a patient-specific update of the calibration parameters of the 3D ultrasound system. Using a self-calibrating implementation of a point-based registration algorithm, and points obtained from ultrasound images of the femurs and pelves of human cadavers, we show that the accuracy of registration to a CT scan is significantly improved compared with a standard algorithm. This new approach provides an effective means of compensating for errors introduced by the propagation of ultrasound through soft tissue, which currently limit the accuracy of conventional methods where the calibration parameters are fixed to values determined preoperatively using a phantom.

Algorithms↗

Validation of PET imaging by alignment to histology slices.

The aim of this project is to verify the accuracy of positron emission tomography (PET) in identifying the tumour boundary and eventually to enable PET-guided resection with removal of significantly smaller margins. We present a novel use of an image-guided surgery system to enable alignment of preoperative PET images to postoperative histology. The oral cancer patients must have a high resolution CT scan as well as undergoing PET imaging. Registration of these images to the patient during surgery is achieved using a device that attaches to the patient's upper or lower teeth. During the procedure markers are placed around the lesion within tissue that is to be resected. These are marked along with any convenient anatomical landmarks using the image guidance system, providing the location of the points in the preoperative images. After the sample has been resected, slices through at least 3 of these points are made and photographed. Registration should be possible using these landmarks, but the accuracy of alignment is much improved by marking the bone surface in the histology image and registering to preoperative CT.

Algorithms↗

Cadaver validation of intensity-based ultrasound to CT registration.

A method is presented for the registration of tracked B-mode ultrasound images to a CT volume of a femur or pelvis. This registration can allow tracked surgical instruments to be aligned with the CT image or an associated preoperative plan. Our method requires no manual segmentation of either the ultrasound images or the CT volume. The CT and US images are processed to produce images where the image intensity represents the probability of the presence of a bone edge. These images are then registered together using normalised cross-correlation as a similarity measure. The parameter which represents the speed of sound through tissue has also been included in the registration optimisation process. Experiments have been carried out on six cadaveric femurs and three cadaveric pelves. Registration results were compared with a "gold standard" registration acquired using bone implanted fiducial markers. Results show the registration method to be accurate, on average, to 1.7 mm root-mean-square target registration error.

Algorithms↗

Novel approaches to the measurement of arterial blood flow from dynamic digital X-ray images.

We have developed two new algorithms for the measurement of blood flow from dynamic X-ray angiographic images. Both algorithms aim to improve on existing techniques. First, a model-based (MB) algorithm is used to constrain the concentration-distance curve matching approach. Second, a weighted optical flow algorithm (OP) is used to improve on point-based optical flow methods by averaging velocity estimates along a vessel with weighting based on the magnitude of the spatial derivative. The OP algorithm was validated using a computer simulation of pulsatile blood flow. Both the OP and the MB algorithms were validated using a physiological blood flow circuit. Dynamic biplane digital X-ray images were acquired following injection of iodine contrast medium into a variety of simulated arterial vessels. The image data were analyzed using our integrated angiographic analysis software SARA to give blood flow waveforms using the MB and OP algorithms. These waveforms were compared to flow measured using an electromagnetic flow meter (EMF). In total 4935 instantaneous measurements of flow were made and compared to the EMF recordings. It was found that the new algorithms showed low measurement bias and narrow limits of agreement and also out-performed the concentration-distance curve matching algorithm (ORG) and a modification of this algorithm (PA) in all studies.

Algorithms↗

A comparison of a similarity-based and a feature-based 2-D-3-D registration method for neurointerventional use.

Two-dimensional (2-D)-to-three-dimensional (3-D) registration can improve visualization which may aid minimally invasive neurointerventions. Using clinical and phantom studies, two state-of-the-art approaches to rigid registration are compared quantitatively: an intensity-based algorithm using the gradient difference similarity measure; and an iterative closest point (ICP)-based algorithm. The gradient difference approach was found to be more accurate, with an average registration accuracy of 1.7 mm for clinical data, compared to the ICP-based algorithm with an average accuracy of 2.8 mm. In phantom studies, the ICP-based algorithm proved more reliable, but with more complicated clinical data, the gradient difference algorithm was more robust. Average computation time for the ICP-based algorithm was 20 s per registration, compared with 14 min and 50 s for the gradient difference algorithm.

Algorithms↗

Alignment of sparse freehand 3-D ultrasound with preoperative images of the liver using models of respiratory motion and deformation.

We present a method for alignment of an interventional plan to optically tracked two-dimensional intraoperative ultrasound (US) images of the liver. Our clinical motivation is to enable the accurate transfer of information from three-dimensional preoperative imaging modalities [magnetic resonance (MR) or computed tomography (CT)] to intraoperative US to aid needle placement for thermal ablation of liver metastases. An initial rigid registration to intraoperative coordinates is obtained using a set of US images acquired at maximum exhalation. A preprocessing step is applied to both the preoperative images and the US images to produce evidence of corresponding structures. This yields two sets of images representing classification of regions as vessels. The registration then proceeds using these images. The preoperative images and plan are then warped to correspond to a single US slice acquired at an unknown point in the breathing cycle where the liver is likely to have moved and deformed relative to the preoperative image. Alignment is constrained using a patient-specific model of breathing motion and deformation. Target registration error is estimated by carrying out simulation experiments using resliced MR volumes to simulate real US and comparing the registration results to a "bronze-standard" registration performed on the full MR volume. Finally, the system is tested using real US and verified using visual inspection.

Algorithms↗

The effect of image colour distortion on evaluation of donor liver suitability for transplantation.

Some medical applications rely on the use of colour in the diagnostic process, even when poor colour reproduction can affect diagnosis. In this paper, we investigate the effect colour distortion can have on assessment of livers for possible transplantation. We compare the diagnostic effects for the likely colour shifts when illuminant and camera remain uncalibrated or when a monitor is incorrectly calibrated. We describe methods that can result in accurate reproduction of image colour on visual displays and determine whether accurate colour reproduction is necessary for effective liver assessment.

Color↗

Cardiac catheterisation guided by MRI in children and adults with congenital heart disease.

BACKGROUND: Fluoroscopically guided cardiac catheterisation is an essential tool for diagnosis and treatment of congenital heart disease. Drawbacks include poor soft tissue visualisation and exposure to radiation. We describe the first 16 cases of a novel method of cardiac catheterisation guided by MRI with radiographic support. METHODS: In our cardiac catheterisation laboratory, we combine magnetic resonance and radiographic imaging facilities. We used MRI to measure flow and morphology, and real-time MRI sequences to visualise balloon angiographic catheters. 12 patients underwent diagnostic cardiac catheterisation, two had interventional cardiac catheterisations, and for two patients, MRI was used to plan radiofrequency ablation for treatment of tachyarrhythmias. FINDINGS: In 14 patients, some or all of the cardiac catheterisation was guided by MRI. In two patients undergoing radiofrequency ablation, catheters were manipulated with use of fluoroscopic guidance and outcome was assessed with MRI. All patients received lower amounts of radiation than controls. There was some discrepancy between pulmonary vascular resistance calculated by flow derived from MRI and the traditional Fick method. We were able to superimpose fluoroscopic images of electro physiology electrode catheters on the three dimensional MRI of the cardiac anatomy. INTERPRETATION: We have shown that cardiac catheterisation guided by MRI is safe and practical in a clinical setting, allows better soft tissue visualisation, provides more pertinent physiological information, and results in lower radiation exposure than do fluoroscopically guided procedures. MRI guidance could become the method of choice for diagnostic cardiac catheterisation in patients with congenital heart disease, and an important tool in interventional cardiac catheterisation and radiofrequency ablation.

Adult↗

Information theoretic similarity measures in non-rigid registration.

Mutual Information (MI) and Normalised Mutual Information (NMI) have enjoyed success as image similarity measures in medical image registration. More recently, they have been used for non-rigid registration, most often evaluated empirically as functions of changing registration parameter. In this paper we present expressions derived from intensity histogram representations of these measures, for their change in response to a local perturbation of a deformation field linking two images. These expressions give some insight into the operation of NMI in registration and are implemented as driving forces within a fluid registration framework. The performance of the measures is tested on publicly available simulated multi-spectral MR brain images.

Algorithms↗

Myocardial delineation via registration in a polar coordinate system.

RATIONALE AND OBJECTIVES: Cardiovascular disease is the number one cause of premature death in the western world. Analysis of cardiac function provides clinically useful diagnostic and prognostic information; however, manual analysis of function via delineation is prohibitively time consuming. This article describes a technique for analysis of dynamic magnetic resonance images of the left ventricle using a non-rigid registration algorithm. A manually delineated contour of a single phase was propagated through the dynamic sequence. MATERIALS AND METHODS: Short-axis cine magnetic resonance images were resampled into polar coordinates before all the time frames were aligned using a non-rigid registration algorithm. The technique was tested on 10 patient data sets, a total of 1,052 images were analyzed. RESULTS: Results of this approach were investigated and compared with manual delineation at all phases in the cardiac cycle, and with registration performed in a Cartesian coordinate system. The results correlated very well with manually delineated contours. CONCLUSION: A novel approach to the registration and subsequent delineation of cardiac magnetic resonance images has been introduced. For the endocardium, the polar resampling technique correlated well with manual delineation, and better than for images registered without radial resampling in a Cartesian coordinate system. For the epicardium, the difference was not as apparent with both techniques correlating well.

Algorithms↗

Regulation of angiotensin II receptors in the prostate of the transgenic (mRen-2)27 rat: effect of angiotensin-converting enzyme inhibition.

We examined the regulation/expression of angiotensin II (Ang II) receptors in the transgenic (TG) (mRen-2)27 rat compared to the normal Sprague-Dawley (SD) rat. Ang II receptor binding and mRNA expression were determined by quantitative autoradiography and real-time PCR, respectively. Ang II receptors in the rat prostate rat were of the AT(1) receptor subtype and were significantly reduced in the prostate of the TG rat compared to the normal SD rat. However, AT(1) receptor binding was significantly higher in the prostate of the TG rat treated with the ACE inhibitor lisinopril compared to the untreated TG rat and comparable to the control SD rat. In contrast to the protein, AT(1) receptor mRNA expression was not reduced in the prostate of the TG rat compared to the SD rat. However, AT(1) receptor mRNA was markedly reduced in the prostate of the lisinopril-treated TG rat compared to the untreated TG rat or control SD rat. In conclusion, the findings suggest that AT(1) receptors are present in the rat prostate at a protein level and are subject to down-regulation in the TG rat which may be due to receptor internalisation as a consequence of receptor hyper-stimulation by increased local tissue levels of Ang II. Moreover, AT(1) receptor protein and mRNA expression in the prostate may be inversely modulated.

Adaptor Proteins, Signal Transducing↗

Validation of nonrigid image registration using finite-element methods: application to breast MR images.

This paper presents a novel method for validation of nonrigid medical image registration. This method is based on the simulation of physically plausible, biomechanical tissue deformations using finite-element methods. Applying a range of displacements to finite-element models of different patient anatomies generates model solutions which simulate gold standard deformations. From these solutions, deformed images are generated with a range of deformations typical of those likely to occur in vivo. The registration accuracy with respect to the finite-element simulations is quantified by co-registering the deformed images with the original images and comparing the recovered voxel displacements with the biomechanically simulated ones. The functionality of the validation method is demonstrated for a previously described nonrigid image registration technique based on free-form deformations using B-splines and normalized mutual information as a voxel similarity measure, with an application to contrast-enhanced magnetic resonance mammography image pairs. The exemplar nonrigid registration technique is shown to be of subvoxel accuracy on average for this particular application. The validation method presented here is an important step toward more generic simulations of biomechanically plausible tissue deformations and quantification of tissue motion recovery using nonrigid image registration. It will provide a basis for improving and comparing different nonrigid registration techniques for a diversity of medical applications, such as intrasubject tissue deformation or motion correction in the brain, liver or heart.

Artifacts↗