Review of image-guided radiation therapy.

Image-guided radiation therapy represents a new paradigm in the field of high-precision radiation medicine. A synthesis of recent technological advances in medical imaging and conformal radiation therapy, image-guided radiation therapy represents a further expansion in the recent push for maximizing targeting capabilities with high-intensity radiation dose deposition limited to the true target structures, while minimizing radiation dose deposited in collateral normal tissues. By improving this targeting discrimination, the therapeutic ratio may be enhanced significantly. The principle behind image-guided radiation therapy relies heavily on the acquisition of serial image datasets using a variety of medical imaging platforms, including computed tomography, ultrasound and magnetic resonance imaging. These anatomic and volumetric image datasets are now being augmented through the addition of functional imaging. The current interest in positron-emitted tomography represents a good example of this sort of functional information now being correlated with anatomic localization. As the sophistication of imaging datasets grows, the precise 3D and 4D positions of the target and normal structures become of great relevance, leading to a recent exploration of real- or near-real-time positional replanning of the radiation treatment localization coordinates. This 'adaptive' radiotherapy explicitly recognizes that both tumors and normal tissues change position in time and space during a multiweek course of treatment, and even within a single treatment fraction. As targets and normal tissues change, the attenuation of radiation beams passing through these structures will also change, thus adding an additional level of imprecision in targeting unless these changes are taken into account. All in all, image-guided radiation therapy can be seen as further progress in the development of minimally invasive highly targeted cytotoxic therapies with the goal of substituting remote technologies for direct contact on the part of an operator or surgeon. Although data demonstrating clear-cut superiority of this new high-tech paradigm compared with more conventional radiation treatment approaches are scant, the emergence of preliminary data from several early studies shows that interest in this field is broad based and robust. As outcomes data accumulate, it is very likely that this field will continue to expand greatly. Although at present most of the work is being performed at major academic centers, the enthusiastic adoption of many of the devices and approaches being developed for this field suggest a rapid penetration into the community and the use of the technology by teams of specialists in the fields of radiation medicine, radiation physics and various branches of surgery. A recent survey of practitioners predicted very widespread adoption within the next 10 years.

Humans↗

Assessment of residual error in liver position using kV cone-beam computed tomography for liver cancer high-precision radiation therapy.

PURPOSE: To evaluate the residual error in liver position using breath-hold kilovoltage (kV) cone-beam computed tomography (CT) following on-line orthogonal megavoltage (MV) image-guided breath-hold liver cancer conformal radiotherapy. METHODS AND MATERIALS: Thirteen patients with liver cancer treated with 6-fraction breath-hold conformal radiotherapy were investigated. Before each fraction, orthogonal MV images were obtained during exhale breath-hold, with repositioning for offsets>3 mm, using the diaphragm for cranio-caudal (CC) alignment and vertebral bodies for medial-lateral (ML) and anterior posterior (AP) alignment. After repositioning, repeat orthogonal MV images, orthogonal kV fluoroscopic movies, and kV cone-beam CTs were obtained in exhale breath-hold. The cone-beam CT livers were registered to the planning CT liver to obtain the residual setup error in liver position. RESULTS: After repositioning, 78 orthogonal MV image pairs, 61 orthogonal kV image pairs, and 72 kV cone-beam CT scans were obtained. Population random setup errors (sigma) in liver position were 2.7 mm (CC), 2.3 mm (ML), and 3.0 mm (AP), and systematic errors (Sigma) were 1.1 mm, 1.9 mm, and 1.3 mm in the superior, medial, and posterior directions. Liver offsets>5 mm were observed in 33% of cases; offsets>10 mm and liver deformation>5 mm were observed in a minority of patients. CONCLUSIONS: Liver position after radiation therapy guided with MV orthogonal imaging was within 5 mm of planned position in the majority of patients. kV cone-beam CT image guidance should improve accuracy with reduced dose compared with orthogonal MV image guidance for liver cancer radiation therapy.

Carcinoma, Hepatocellular↗

Spinal cord planning risk volumes for intensity-modulated radiation therapy of head-and-neck cancer.

PURPOSE: To assess planning organ at risk volume (PRV) margins of the spinal cord in intensity-modulated radiotherapy (IMRT) of oropharyngeal cancers, by modeling the effect of geometric uncertainties to estimate the probability of the spinal cord receiving a particular dose. METHODS AND MATERIALS: Five patients with oropharyngeal cancer were treated by IMRT with simultaneous doses of 66 Gy (gross disease) and 54 Gy (subclinical disease) in 30 fractions. Spinal cord doses were limited to 45 Gy. The probability, due to random and systematic patient positioning uncertainties (3-mm standard deviation), of the cord receiving a particular dose was determined. The effect of an on-line setup correction protocol was also modeled. RESULTS: The mean probability of a maximum spinal cord dose of 45 Gy was 1%, with a 6-mm PRV margin. The mean probability of a maximum dose exceeding 40 Gy was 37% (range, 13-77%); this probability is reduced with a setup correction protocol. CONCLUSION: A spinal cord PRV generated with a 6-mm margin leads to a 99% probability of maintaining the maximum spinal cord dose below 45 Gy. The application of an on-line setup correction protocol reduces the cord dose by approximately 5 Gy.

Dose Fractionation, Radiation↗

Online image-guided intensity-modulated radiotherapy for prostate cancer: How much improvement can we expect? A theoretical assessment of clinical benefits and potential dose escalation by improving precision and accuracy of radiation delivery.

PURPOSE: To quantify the theoretical benefit, in terms of improvement in precision and accuracy of treatment delivery and in dose increase, of using online image-guided intensity-modulated radiotherapy (IG-IMRT) performed with onboard cone-beam computed tomography (CT), in an ideal setting of no intrafraction motion/deformation, in the treatment of prostate cancer. METHODS AND MATERIALS: Twenty-two prostate cancer patients treated with conventional radiotherapy underwent multiple serial CT scans (median 18 scans per patient) during their treatment. We assumed that these data sets were equivalent to image sets obtainable by an onboard cone-beam CT. Each patient treatment was simulated with conventional IMRT and online IG-IMRT separately. The conventional IMRT plan was generated on the basis of pretreatment CT, with a clinical target volume to planning target volume (CTV-to-PTV) margin of 1 cm, and the online IG-IMRT plan was created before each treatment fraction on the basis of the CT scan of the day, without CTV-to-PTV margin. The inverse planning process was similar for both conventional IMRT and online IG-IMRT. Treatment dose for each organ of interest was quantified, including patient daily setup error and internal organ motion/deformation. We used generalized equivalent uniform dose (EUD) to compare the two approaches. The generalized EUD (percentage) of each organ of interest was scaled relative to the prescription dose at treatment isocenter for evaluation and comparison. On the basis of bladder wall and rectal wall EUD, a dose-escalation coefficient was calculated, representing the potential increment of the treatment dose achievable with online IG-IMRT as compared with conventional IMRT. RESULTS: With respect to radiosensitive tumor, the average EUD for the target (prostate plus seminal vesicles) was 96.8% for conventional IMRT and 98.9% for online IG-IMRT, with standard deviations (SDs) of 5.6% and 0.7%, respectively (p < 0.0001). The average EUDs of bladder wall and rectal wall for conventional IMRT vs. online IG-IMRT were 70.1% vs. 47.3%, and 79.4% vs. 72.2%, respectively. On average, a target dose increase of 13% (SD = 9.7%) can be achieved with online IG-IMRT based on rectal wall EUDs and 53.3% (SD = 15.3%) based on bladder wall EUDs. However, the variation (SD = 9.7%) is fairly large among patients; 27% of patients had only minimal benefit (<5% of dose increment) from online IG-IMRT, and 32% had significant benefit (>15%-41% of dose increment). CONCLUSIONS: The ideal maximum dose increment achievable with online IG-IMRT is, on average, 13% with respect to the dose-limiting organ of rectum. However, there is a large interpatient variation, ranging <5%-41%. The results can be applied to calibrate other practical online image-guided techniques for prostate cancer radiotherapy, when intratreatment organ motion/deformation and machine delivery accuracy are considered.

Humans↗

Accelerated partial breast irradiation using 3D conformal radiation therapy (3D-CRT).

PURPOSE: We present a novel three-dimensional conformal radiation therapy (3D-CRT) technique to treat the lumpectomy cavity, plus a 1.5-cm margin, in patients with early-stage breast cancer and study its clinical feasibility. METHODS AND MATERIALS: A 3D-CRT technique for partial-breast irradiation was developed using archived CT scans from 7 patients who underwent an active breathing control study. The clinical feasibility of this technique was then assessed in 9 patients who were prospectively enrolled on an Investigational Review Board-approved protocol of partial-breast irradiation. The prescribed dose was 34 Gy in 5 patients and 38.5 Gy in 4 patients, delivered in 10 fractions twice daily over 5 consecutive days. The impact of both breathing motion and patient setup uncertainty on clinical target volume (CTV) coverage was studied, and an appropriate CTV-to-PTV (planning target volume) margin was calculated. RESULTS: By adding a CTV-to-PTV "breathing-only" margin of 5 mm, 98%-100% of the CTV remained covered by the 95% isodose surface at the extremes of normal inhalation and normal exhalation. The "total" CTV-to-PTV margin employed to accommodate organ motion and setup error (10 mm) was found to be sufficient to accommodate the observed uncertainty in the delivery precision. Patient tolerance was excellent, and acute toxicity was minimal. No skin changes were noted during treatment, and at the initial 4-8-week follow-up visit, only mild localized hyperpigmentation and/or erythema was observed. No instances of symptomatic radiation pneumonitis have occurred. CONCLUSIONS: Accelerated partial-breast irradiation using 3D-CRT is technically feasible, and acute toxicity to date has been minimal. A CTV-to-PTV margin of 10 mm seems to provide coverage for most patients. However, more patients and additional studies will be needed to validate the accuracy of this margin, and longer follow-up will be needed to assess acute and chronic toxicity, tumor control, and cosmetic results.

Aged↗

The anatomy of the iliolumbar vein. A cadaver study.

We carried out a cadaver study of 16 iliolumbar veins in order to define the surgical anatomy. Two variants were found; a single vein at a mean distance of 3.74 cm from the inferior vena cava (11 of 16) and two separate draining veins at a mean distance from the vena cava of 2.98 cm for the proximal and 6.24 cm for the distal stem (5 of 16). Consistently, the proximal vein tore on attempted medial retraction of the great vessels. The mean length of the vein was 1.6 cm and its mean width 1.07 cm. Three stems were shorter than 0.5 cm. Two or more tributaries usually drained the iliacus and psoas muscles, and the fifth lumbar vertebral body. The obturator nerve crossed all veins superficially at a mean of 2.76 cm lateral to the mouth. In four of these, this distance was less than 1.5 cm. Usually, the lumbosacral trunk crossed deep, at a mean distance of 2.5 cm lateral to the mouth, but in three veins, this distance was 1 cm or less. Our findings emphasise the need for proper dissection of the iliolumbar vein before ligature during exposure of the anterior lumbar spine.

Cadaver↗