PubMed Health⌕ Search

Biomedical subjects

David Juncker

Publications and source records attributed to David Juncker.

6 recordsLinked to original sources

Biomimetic Hydrogels with Nucleus Pulposus-like Viscoelasticity and ECM Peptides for Discogenic Differentiation of Stem Cells.

Intervertebral disc (IVD) degeneration is a leading cause of low back pain (LBP), primarily originating in the nucleus pulposus (NP). Regenerative strategies combining mesenchymal stem cells (MSCs) with biomaterials offer great potential for NP repair by replenishing cells and restoring extracellular matrix (ECM). However, key translational challenges remain, including limited stem cell differentiation, poor cell survival in the harsh degenerative niche, and insufficient biomaterial support. While matrix viscoelasticity has been shown to influence adipose-derived stem cell (ASC) discogenic differentiation, its interplay with cell-adhesive ligands for IVD regeneration remains unclear. Moreover, most current hydrogels fail to replicate the ultrafast stress relaxation properties of native non-degenerative human NP tissue. Here, we developed viscoelastic ECM peptide-functionalized hydrogels (VEPH), specifically designed to mimic healthy human NP biomechanics and promote ASC differentiation for NP regeneration. We biochemically conjugated NP ECM-derived adhesive peptides (IKVAV, hA5G26, CHAD) through maleimide-thiol click chemistry, achieving hydrogels with significantly faster stress relaxation (∼25 s) compared to conventional viscoelastic alginate hydrogels (>100 s). Our results demonstrated that VEPH supported >95% ASC viability and robust metabolic activity over 21 days in 3D culture. Notably, the IKVAV-functionalized hydrogel significantly enhanced ASC cell-matrix interactions, upregulated NP marker expression (KRT18, HIF-1α, ITGA3, and CD24), and promoted type-II collagen secretion, indicating an NP-committed cell fate. Our findings highlight the synergistic roles of matrix viscoelasticity and NP-specific biochemical cues in directing ASC discogenic differentiation and advancing novel biomaterial design for IVD regeneration.

cell-adhesive peptides↗

Multipurpose microfluidic probe.

Microfluidic systems allow (bio)chemical processes to be miniaturized with the benefit of shorter time-to-result, parallelism, reduced sample consumption, laminar flow, and increased control and efficiency. However, such miniaturization inherently limits the size of the solid objects that can be processed and entails new challenges such as the interfacing of macroscopic samples with microscopic conduits. Here, we report a microfluidic probe (MFP) that overcomes these problems by combining the concepts of 'microfluidics' and of 'scanning probes'. Here, liquid boundaries formed by hydrodynamic forces underneath the MFP confine a flow of processing solution and replace the solid walls of closed microchannels. The MFP is therefore mobile and can be used to process large surfaces and objects by scanning across them. We illustrate the versatility of this concept with several examples including protein microarraying, complex gradient-formation, multiphase laminar-flow patterning, erasing, localized staining of cells and the contact-free detachment of a single cell. Many constraints imposed by the monolithic construction of microfluidic channels can now be circumvented using an MFP, opening up new avenues for microfluidic processing.

Journal Article↗

High-sensitivity miniaturized immunoassays for tumor necrosis factor alpha using microfluidic systems.

We use microfluidic chips to detect the biologically important cytokine tumor necrosis factor alpha (TNF- alpha) with picomolar sensitivity using sub-microliter volumes of samples and reagents. The chips comprise a number of independent capillary systems (CSs), each of which is composed of a filling port, an appended microchannel, and a capillary pump. Each CS fills spontaneously by capillary forces and includes a self-regulating mechanism that prevents adventitious drainage of the microchannels. Thus, interactive control of the flow in each CS is easily achieved via collective control of the evaporation in all CSs by means of two Peltier elements that can independently heat and cool. Long incubation times are crucial for high sensitivity assays and can be conveniently obtained by adjusting the evaporation rate to have low flow rates of approximately 30 nL min(-1). The assay is a sandwich fluorescence immunoassay and takes place on the surface of a poly(dimethylsiloxane)(PDMS) slab placed across the microchannels. We precoat PDMS with capture antibodies (Abs), localize the capture of analyte molecules using a chip, then bind the captured analyte molecules with fluorescently-tagged detection Abs using a second chip. The assay results in a mosaic of fluorescence signals on the PDMS surface which are measured using a fluorescence scanner. We show that PDMS is a compatible material for high sensitivity fluorescence assays, provided that detection antibodies with long excitation wavelength fluorophores ( > or =580 nm) are employed. The chip design, long incubation times, proper choice of fluorophores, and optimization of the detection Ab concentration all combine to achieve high-sensitivity assays. This is exemplified by an experiment with 170 assay sites, occupying an area of approximately 0.6 mm(2) on PDMS to detect TNF-alpha in 600 nL of a dendritic cell (DC) culture medium with a sensitivity of approximately 20 pg mL(-1)(1.14 pM).

Antibodies↗

Simultaneous detection of C-reactive protein and other cardiac markers in human plasma using micromosaic immunoassays and self-regulating microfluidic networks.

We show a proof-of-concept in which we combine our previously published concepts of micromosaic immunoassays (microMIAs) with self-regulating microfluidic networks (microFNs) to detect C-reactive protein (CRP) and other cardiac markers such as myoglobin (Mb) and cardiac Troponin I (cTnI). The microFNs are microfabricated in Si, have a well-defined surface chemistry, and are affixed to a bibulous material so as to self-regulate the displacement of an aliquot of liquid through the microFNs using capillary forces. An open section of the channels of the microFNs is covered with a hydrophobic poly(dimethylsiloxane) (PDMS) slab that acts as the substrate for a solid-phase immunoassay. Here, individual assays are conducted using independent channels. These assays are "sequential": series of samples, reagents, and buffers are displaced one after the other over the PDMS surface, and, as these assays are conducted under "microfluidic" conditions, they are fast to perform, very economical in their use of reagents, extremely integrated, and yield high-quality signals. The combinatorial character of microMIAs is exploited to optimize the assay parameters for detecting CRP. In particular, we found it optimal to deposit the capture antibody for CRP on PDMS at a concentration between 20 and 500 microg ml(-1) in PBS in 1 min and to detect captured CRP in 2 min using a detection antibody having a concentration in PBS of 120 microg ml(-1). With this method, CRP is quantitatively detected within 10 min in one microliter of human plasma down to concentrations of 30 ng ml(-1), which suggests the possibility to detect CRP at clinically relevant concentrations for the management of coronary heart disease (CHD) and systemic inflammation.

Antibodies↗

Autonomous microfluidic capillary system.

The transport of minute amounts of liquids using microfluidic systems has opened avenues for higher throughput and parallelization of miniaturized bio/chemical processes combined with a great economy of reagents. In this report, we present a microfluidic capillary system (CS) that autonomously transports aliquots of different liquids in sequence: liquids pipetted into the service port of the CS flow unidirectionally through the various sections of the CS, which comprises a 15-pL reaction chamber, into the capillary pump. A CS can thus be operated by simply delivering the different samples to its service port. The liquid transport concept presented here is advantageous because the pumping and valving functions are integrated into the device by means of capillary phenomena, and it therefore does not require any external power supply or control device. Thus, arrays of CSs can easily be formed by cloning a functional CS. Alternatively, the flow of liquids in CSs can also be interactively tuned if desired by (i) forcing the evaporating of liquid out of the capillary pumps and (ii) by contacting a secondary, removable capillary pump to the embedded ones. We illustrate the possibilities of CSs by conducting a surface immunoassay for a cardiac marker, within 25 min, on an area of 100 x 100 microm2, using 16 sequential filling steps.

Journal Article↗