PubMed Health⌕ Search

Biomedical subjects

David Kohler

Publications and source records attributed to David Kohler.

2 recordsLinked to original sources

A phase I/II study of high-dose tamoxifen in combination with vinblastine in patients with androgen-independent prostate cancer.

In this phase I/II clinical trial the antitumor activity of high-dose tamoxifen when administered in combination with vinblastine was assessed and the toxicity profile of this combination characterized. All 25 patients enrolled in this study were required to have androgen-independent prostate cancer and to maintain androgen ablation during treatment. Vinblastine was given by continuous infusion over 5 days. Doses were increased from 0.9 mg/m2/day to 1.5 mg/m2/day in successive cohorts of at least 3 patients, with no further escalation even in the absence of dose-limiting toxicity. Intra-patient dose escalation was permitted. Tamoxifen was administered at a dose of 200 mg/kg on day 1, then 120 mg/kg/day on day 2. Standard response criteria were utilized to assess antitumor activity and CTC toxicity criteria were used. Quality of life (QOL) pain assessments were evaluated at each visit to the clinic. Most patients tolerated the highest dose of vinblastine at 1.5 mg/m2/day by continuous infusion over 5 days with 200 mg/kg/day of tamoxifen on day 1 and day 2. One patient had a greater than 50% decline in prostate-specific antigen that lasted for 170 days. Two patients received dose reductions because of toxicity. The most common serious toxicities included neutropenia, and fatigue. Reversible neurosensory, neuromotor, neurocortical and neurocerebellar toxicities were reported. Six of the 25 patients enrolled in the study (24%) experienced reversible neurologic toxicity of at least grade III. No statistically significant differences between precycle assessment of QOL and subsequent cycles were observed. It is concluded that vinblastine at 1.5 mg/m2/day continuous i.v. infusion combined with tamoxifen 200 mg/kg/day on day 1 and day 2 is inactive, and not without toxicity in the treatment of advanced metastatic androgen-independent prostate cancer.

Aged↗

A simplified headspace biochemical oxygen demand test protocol based on oxygen measurements using a fiber optic probe.

Batch respirometric tests have many advantages over the conventional biochemical oxygen demand (BOD) method for analysis of wastewaters, including the use of nondiluted samples, a more rapid exertion of oxygen demand, and reduced sample preparation time. The headspace biochemical oxygen demand (HBOD) test can be used to obtain oxygen demands in 2 or 3 days that can predict 5-day biochemical oxygen demand (BOD5) results. The main disadvantage of the HBOD and other respirometric tests has been the lack of a simple and direct method to measure oxygen concentrations in the gas phase. The recent commercial production of a new type of fiber optic oxygen probe, however, provides a method to eliminate this disadvantage. This fiber optic probe, referred to here as the HBOD probe, was tested to see if it could be used in HBOD tests. Gas-phase oxygen measurements made with the HBOD probe took only a few seconds and were not significantly different from those made using a gas chromatograph (t test: n = 15, R2 = 0.9995, p < 0.001). In field tests using the HBOD probe procedure, the probe greatly reduced sample analysis time compared with previous HBOD and BOD protocols and produced more precise results than the BOD test for wastewater samples from two treatment plants (University Area Joint Authority [UAJA] Wastewater Treatment Plant in University Park, Pennsylvania, and The Pennsylvania State University [PSU] Wastewater Treatment Plant in University Park). Headspace biochemical oxygen demand measurements on UAJA primary clarifier effluent were 59.9 +/- 2.4% after 2 days (HBOD2) and 73.0 +/- 3.1% after 3 days (HBOD) of BOD, values, indicating that BOD5 values could be predicted by multiplying HBOD2 values by 1.67 +/- 0.07 or HBOD3 by 1.37 +/- 0.06. Similarly, tests using PSU wastewater samples could be used to provide BOD5 estimates by multiplying the HBOD2 by 1.24 +/- 0.04 or by multiplying the HBOD3 by 0.97 +/- 0.03. These results indicate that the HBOD fiber optic probe can be used to obtain reliable oxygen demands in batch respirometric tests such as the HBOD test.

Biodegradation, Environmental↗