PubMed Health⌕ Search

Biomedical subjects

David L Wilson

Publications and source records attributed to David L Wilson.

At least 19 recordsLinked to original sources

Method to correct intensity inhomogeneity in MR images for atherosclerosis characterization.

We are developing methods to characterize atherosclerotic disease in human carotid arteries using multiple MR images having different contrast mechanisms (T1W, T2W, PDW). To enable the use of voxel gray values for interpretation of disease, we created a new method, local entropy minimization with a bicubic spline model (LEMS), to correct the severe (approximately 80%) intensity inhomogeneity that arises from the surface coil array. This entropy-based method does not require classification and robustly addresses some problems that are more severe than those found in brain imaging, including noise, steep bias field, sensitivity of artery wall voxels to edge artifacts, and signal voids near the artery wall. Validation studies were performed on a synthetic digital phantom with realistic intensity inhomogeneity, a physical phantom roughly mimicking the neck, and patient carotid artery images. We compared LEMS to a modified fuzzy c-means segmentation based method (mAFCM), and a linear filtering method (LINF). Following LEMS correction, skeletal muscles in patient images were relatively isointense across the field of view. In the physical phantom, LEMS reduced the variation in the image to 1.9% and across the vessel wall region to 2.5%, a value which should be sufficient to distinguish plaque tissue types, based on literature measurements. In conclusion, we believe that the correction method shows promise for aiding human and computerized tissue classification from MR signal intensities.

Algorithms↗

Deformable and rigid registration of MRI and microPET images for photodynamic therapy of cancer in mice.

We are investigating imaging techniques to study the tumor response to photodynamic therapy (PDT). Positron emission tomography (PET) can provide physiological and functional information. High-resolution magnetic resonance imaging (MRI) can provide anatomical and morphological changes. Image registration can combine MRI and PET images for improved tumor monitoring. In this study, we acquired high-resolution MRI and microPET 18F-fluorodeoxyglucose (FDG) images from C3H mice with RIF-1 tumors that were treated with Pc 4-based PDT. We developed two registration methods for this application. For registration of the whole mouse body, we used an automatic three-dimensional, normalized mutual information algorithm. For tumor registration, we developed a finite element model (FEM)-based deformable registration scheme. To assess the quality of whole body registration, we performed slice-by-slice review of both image volumes; manually segmented feature organs, such as the left and right kidneys and the bladder, in each slice; and computed the distance between corresponding centroids. Over 40 volume registration experiments were performed with MRI and microPET images. The distance between corresponding centroids of organs was 1.5 +/- 0.4 mm which is about 2 pixels of microPET images. The mean volume overlap ratios for tumors were 94.7% and 86.3% for the deformable and rigid registration methods, respectively. Registration of high-resolution MRI and microPET images combines anatomical and functional information of the tumors and provides a useful tool for evaluating photodynamic therapy.

Animals↗

Optimization of detector pixel size for stent visualization in x-ray fluoroscopy.

Pixel size is of great interest in the flat-panel detector design because of its potential impact on image quality. In the particular case of angiographic x-ray fluoroscopy, small pixels are required in order to adequately visualize interventional devices such as guidewires and stents which have wire diameters as small as 200 and 50 microm, respectively. We used quantitative experimental and modeling techniques to investigate the optimal pixel size for imaging stents. Image quality was evaluated by the ability of subjects to perform two tasks: detect the presence of a stent and discriminate a partially deployed stent from a fully deployed one in synthetic images. With measurements at 50, 100, 200, and 300 microm, the 100 microm pixel size gave the maximum contrast sensitivity for the detection experiment with the idealized direct detector. For an idealized indirect detector with a scintillating layer, an optimal pixel size was obtained at 200 microm pixel size. A channelized human observer model predicted a peak at 150 and 170 microm, for the idealized direct and indirect detectors, respectively. With regard to the stent deployment task for both detector types, smaller pixel sizes are favored and there is a steep drop in performance with larger pixels. In general, with the increasing exposures, the model and measurements give the enhanced contrast sensitivities and a smaller optimal pixel size. The effects of electronic noise and fill factor were investigated using the model. We believe that the experimental results and human observer model predications can help guide the flat-panel detector design. In addition, the human observer model should work on the similar images and be applicable to the future model and actual flat-panel implementations.

Algorithms↗

Three-dimensional registration of magnetic resonance image data to histological sections with model-based evaluation.

We developed a three-dimensional (3D) registration method to align medical scanner data with histological sections. After acquiring 3D medical scanner images, we sliced and photographed the tissue using, a custom apparatus, to obtain a volume of tissue section images. Histological samples from the sections were digitized using a video microscopy system. We aligned the histology and medical images to the reference tissue images using our 3D registration method. We applied the method to correlate in vivo magnetic resonance (MR) and histological measurements for radio-frequency thermal ablation lesions in rabbit thighs. For registration evaluation, we used an ellipsoid model to describe the lesion surfaces. The model surface closely fit the inner (M1) and outer (M2) boundaries of the hyperintense region in MR lesion images, and the boundary of necrosis (H1) in registered histology images. We used the distance between the model surfaces to indicate the 3D registration error. For four experiments, we measured a registration accuracy of 0.96+/- 0.13 mm (mean+/-SD) from the absolute distance between the M2 and H1 model surfaces, which compares favorably to the 0.70 mm in-plane MR voxel dimension. This suggests that our registration method provides sufficient spatial correspondence to correlate 3D medical scanner and histology data.

Anatomy, Cross-Sectional↗

Semiautomatic nonrigid registration for the prostate and pelvic MR volumes.

RATIONALE AND OBJECTIVES: Three-dimensional (3D) nonrigid image registration for potential applications in prostate cancer treatment and interventional magnetic resonance (iMRI) imaging-guided therapies were investigated. MATERIALS AND METHODS: An almost fully automated 3D nonrigid registration algorithm using mutual information and a thin plate spline (TPS) transformation for MR images of the prostate and pelvis were created and evaluated. In the first step, an automatic rigid body registration with special features was used to capture the global transformation. In the second step, local feature points (FPs) were registered using mutual information. An operator entered only five FPs located at the prostate center, left and right hip joints, and left and right distal femurs. The program automatically determined and optimized other FPs at the external pelvic skin surface and along the femurs. More than 600 control points were used to establish a TPS transformation for deformation of the pelvic region and prostate. Ten volume pairs were acquired from three volunteers in the diagnostic (supine) and treatment positions (supine with legs raised). RESULTS: Various visualization techniques showed that warping rectified the significant pelvic misalignment by the rigid-body method. Gray-value measures of registration quality, including mutual information, correlation coefficient, and intensity difference, all improved with warping. The distance between prostate 3D centroids was 0.7 +/- 0.2 mm after warping compared with 4.9 +/- 3.4 mm with rigid-body registration. CONCLUSION: Semiautomatic nonrigid registration works better than rigid-body registration when patient position is changed greatly between acquisitions. It could be a useful tool for many applications in the management of prostate.

Algorithms↗

Semiautomatic parametric model-based 3D lesion segmentation for evaluation of MR-guided radiofrequency ablation therapy.

RATIONALE AND OBJECTIVES: Interventional magnetic resonance imaging (iMRI) allows real-time guidance and optimization of radiofrequency ablation of pathologic tissue. For many tissues, resulting lesions have a characteristic two-boundary appearance featuring an inner region and an outer hyper-intense margin in both T2 and contrast-enhanced (CE) T1-weighted MR images. We created a geometric model-based semiautomatic method to aid in real-time lesion segmentation, cross-sectional/three-dimensional visualization, and intra/posttreatment evaluation. MATERIALS AND METHODS: Our method relies on a 12-parameter, 3-dimensional, globally deformable model with quadric surfaces that describe both lesion boundaries. We present an energy minimization approach to quickly and semiautomatically fit the model to a gray-scale MR image volume. We applied the method to in vivo lesions (n = 10) in a rabbit thigh model, using T2 and CE T1-weighted MR images, and compared the results with manually segmented boundaries. RESULTS: For all lesions, the median error was < or =1.21 mm for the inner region and < or =1.00 mm for the outer hyper-intense region, values that favorably compare to a voxel width of 0.7 mm and distances between the borders manually segmented by the two operators. CONCLUSION: Our method provides a precise, semiautomatic approximation of lesion shape for ellipsoidal lesions. Further, the method has clinical applications in lesion visualization, volume estimation, and treatment evaluation.

Algorithms↗

Correcting spatial distortion in histological images.

We described an interactive method for correcting spatial distortion in histology samples, applied them to a large set of image data, and quantitatively evaluated the quality of the corrections. We demonstrated registration of histology samples to photographs of macroscopic tissue samples and to MR images. We first described methods for obtaining corresponding fiducial and anatomical points, including a new technique for determining boundary correspondence points. We then describe experimental methods for tissue preparation, including a technique for adding color-coded internal and boundary ink marks that are used to validate the method by measuring the registration error. We applied four different transformations with internal and boundary correspondence points, and measured the distance error between other internal ink fiducials. A large number of boundary points, typically 20-30, and at least two internal points were required for accurate warping registration. Interior errors with the transformation methods were ordered: thin plate spline (TPS) approximately non-warping<<triangle warping<polynomial warping. Although non-warping surprisingly gave the lowest interior distance error (0.5+/-0.3mm), TPS was more robust, gave an insignificantly greater error (0.6+/-0.3mm) and much better results near boundaries where distortion was more evident, and allowed us to correct torn histology samples, a common problem. Using the method to evaluate RF thermal ablation, we found good zonal correlation between MR images and corrected histology samples. The method can be practically applied to this and other emerging applications such as in vivo molecular imaging.

Algorithms↗

Transitioning from analog to digital audio recording in childhood speech sound disorders.

Few empirical findings or technical guidelines are available on the current transition from analog to digital audio recording in childhood speech sound disorders. Of particular concern in the present context was whether a transition from analog- to digital-based transcription and coding of prosody and voice features might require re-standardizing a reference database for research in childhood speech sound disorders. Two research transcribers with different levels of experience glossed, transcribed, and prosody-voice coded conversational speech samples from eight children with mild to severe speech disorders of unknown origin. The samples were recorded, stored, and played back using representative analog and digital audio systems. Effect sizes calculated for an array of analog versus digital comparisons ranged from negligible to medium, with a trend for participants' speech competency scores to be slightly lower for samples obtained and transcribed using the digital system. We discuss the implications of these and other findings for research and clinical practise.

Analog-Digital Conversion↗

Inter- and Intra-Observer Variability Assessment of in Vivo Carotid Plaque Burden Quantification Using Multi-Contrast Dark Blood MR Images.

UNLABELLED: The chapter presents the research to test the hypotheses that (1) vessel wall volume measurements from dark blood MR images with multiple contrast-weightings (T1W, T2W and PDW) are highly reproducible, and that (2) the intra-observer and inter-observer variability of carotid wall volume measurements will be less than those obtained with maximum wall area (MaxWA) measurements. METHODS: Sixteen patients (aged 72 +/- 7years) with carotid stenosis documented by duplex ultrasound were recruited for the study. Dark blood T1W, PDW and T2W MR images were used to measure carotid wall volume and MaxWA by two independent observers for inter-observer and intra-observer variability assessment. RESULTS: The intra-observer absolute difference of carotid wall volume for T1W, T2W and PDW images were 67.3 +/- 47.5 mm(3) (2.3 +/- 1.8%), 63.2 +/- 52.2 mm(3) (2.0 +/- 1.3%), and 69.8 +/- 45.2 mm(3) (2.4 +/- 1.7%) respectively. The inter-observer absolute difference of carotid wall volume for T1W, T2W and PDW images were 103.5 +/- 141.8 mm(3) (3.0 +/- 3.1%), 95.9 +/- 102.1 mm(3) (3.1 +/- 2.6%), and 132.1 +/- 87.8 mm(3) (4.3 +/- 2.7%) respectively. The intra-observer absolute difference of carotid MaxWA for T1W, T2W and PDW images were 6.9 +/- 5.0 mm(2) (4.2 +/- 2.9%), 5.1 +/- 4.2 mm(2) (3.1 +/- 2.3%) and 7.5 +/- 4.7 mm(2) (4.2 +/- 2.7%) respectively. The inter-observer absolute difference of carotid MaxWA for T1W, T2W and PDW images were 9.5 +/- 4.2 mm(2) (5.8 +/- 2.3%), 6.4 +/- 6.1 mm(2) (3.8 +/- 3.1%) and 10.8 +/- 7.3 mm(2) (6.1 +/- 3.7%) respectively. Both intra- and inter-observer variability in carotid volume measurement tend to be smaller than that in carotid MaxWA measurement with intraclass correlation coefficients ranged 0.932 to 0.987 for volume measurement and 0.822 to 0.946 for MaxWA measurement.

Carotid Artery Diseases↗

Three-Dimensional Volume Registration of Carotid MR Images.

This chapter describes automatic three-dimensional registration techniques for magnetic resonance images of carotid vessels. The immediate applications include atherosclerotic plaque characterization and plaque burden quantification vector-based segmentation using dark blood MR images having multiple contrast weightings (proton density (PD), T1, and T2). Another application is the measurement of disease progression and regression with drug trials. A normalized mutual information registration algorithm is applied to compensate movements between image acquisitions. PD, T1, and T2 images were acquired from patients and volunteers and then matched for image analysis. Visualization methods such as contour overlap showed that vessels well aligned after registration. Distance measurements from the landmarks indicated that the registration method worked well with an error of less than 1-mm.

Algorithms↗

Automatic model-based evaluation of magnetic resonance-guided radio frequency ablation lesions with histological correlation.

PURPOSE: To develop a model-based method for automatic evaluation of radio frequency (RF) ablation treatment using magnetic resonance (MR) images. MATERIALS AND METHODS: RF current lesions were generated in a rabbit thigh model using MR imaging (MRI) guidance. We created a 12-parameter, three-dimensional, globally deformable model with quadric surfaces that delineates lesion boundaries and is automatically fitted to MR grayscale data. We applied this method to in vivo T2- and contrast-enhanced (CE) T1-weighted MR images acquired immediately post-ablation and four days later. We then compared results to manually segmented MR and three-dimensional registered corresponding histological boundaries of cellular damage. RESULTS: Resulting lesions featured a two-boundary appearance with an inner region and an outer hyperintense margin on MR images. For automated vs. manual MR boundaries, the mean errors over all specimens were 0.19 +/- 0.51 mm and 0.27 +/- 0.52 mm for the inner surface, and -0.29 +/- 0.40 mm and -0.12 +/- 0.17 mm for the outer surface, for T2- and CE T1-weighted images, respectively. For automated vs. histological boundaries, mean errors over all specimens were 0.07 +/- 0.64 mm and 0.33 +/- 0.71 mm for the inner surface, and -0.27 +/- 0.69 mm and 0.02 +/- 0.43 mm for the outer surface, for T2- and CE T1-weighted images, respectively. All boundary errors compared favorably to MR voxel dimensions, which were 0.7 mm in-plane and 3.0 mm thick. CONCLUSION: The method is accurate both in describing MR-apparent boundaries and in predicting histological response and has applications in lesion visualization, volume estimation, and treatment evaluation.

Algorithms↗

Radiofrequency thermal ablation: correlation of hyperacute MR lesion images with tissue response.

PURPOSE: To investigate the hypothesis that the outer boundary of the hyperintense region observed in hyperacute (several minutes post-ablation) T2 and gadolinium contrast-enhanced (CE) T1-weighted magnetic resonance (MR) lesion images is an accurate predictor of eventual cell death from radiofrequency (RF) thermal ablation. MATERIALS AND METHODS: A low-field, open MR imaging system was used to guide an ablation electrode into a thigh muscle of five rabbits and acquire in vivo T2 and CE T1-weighted MR volumes. Ablation occurred by applying RF current for two minutes with the electrode's temperature maintained at 90 degrees +/- 2 degrees C. After fixation, we sliced and photographed the tissue at 3 mm intervals, using a specially designed apparatus, to obtain a volume of tissue images. Digital images of hematoxylin and eosin (H&E) and Masson trichrome-stained histologic samples were obtained, and distinct regions of tissue damage were labeled using a video microscopy system. After the MR and histology images were aligned using a three-dimensional registration method, we compared tissue damage boundaries identified in histology with boundaries marked in MR images. RESULTS: The lesions have distinct zones of tissue damage histologically: a central zone of necrotic cells surrounded by an outer zone with cells that appeared non-viable and associated with marked interstitial edema. In 14 histology images from five lesions, the inner and outer boundaries of the outer zone were compared with the boundaries of a hyperintense rim that surrounds a central hypointense region in the T2 and CE T1-weighted MR images. For T2 and CE T1-weighted MR images, respectively, the mean absolute distance was 1.04 +/- 0.30 mm (mean +/- SD) and 1.00 +/- 0.34 mm for the inner boundaries, and 0.96 +/- 0.34 mm and 0.94 +/- 0.44 mm for the outer boundaries. The mean absolute distances for T2 and CE T1-weighted MR images were not sufficiently different to achieve statistical significance (P = 0.745, 0.818, for the inner and outer boundary, respectively). CONCLUSION: In hyperacute T2 and CE T1-weighted MR lesion images, observations strongly suggest that the outer boundary of the hyperintense rim corresponds to the region of eventual cell necrosis within a distance comparable to our ability to measure. This is good evidence that during RF ablation procedures, MR lesion images can be used to accurately localize the zone of irreversible tissue damage at the lesion margin.

Animals↗

Quantitative computed tomography analysis of local chemotherapy in liver tissue after radiofrequency ablation.

RATIONALE AND OBJECTIVES: Computed tomography (CT) was used to noninvasively monitor local drug pharmacokinetics from polymer implants in rat livers before and following radiofrequency ablation. MATERIALS AND METHODS: Polymer matrixes containing carboplatin (a platinum-containing chemotherapeutic agent) were implanted into rat livers either immediately after radiofrequency ablation (n = 15) or without prior treatment (n = 15). The animals were divided into five subgroups (n = 3 per group) and subjected to a terminal CT scan at 6, 24, 48, 96, or 144 hours. Carboplatin concentration in tissue and within the implant matrix was correlated with CT intensity, and standard curves were produced for each environment. This correlation was used to evaluate the differences in drug transport properties between normal and ablated rat livers. A quantitative image analysis method was developed and used to evaluate the release rate and tissue distribution of carboplatin in normal and ablated liver tissue. The CT data were validated by previously reported atomic absorption spectroscopy measurement of implant and tissue drug levels. RESULTS: Correlation of carboplatin concentration and Hounsfield units results in a linear relationship with correlation coefficients (slopes) of 15 and 4 Hounsfield units/(mg/mL), for carboplatin in tissue and polymer, respectively. Noninvasive monitoring of local pharmacokinetics in normal and ablated tissues indicates that ablation before local carboplatin delivery increases the retention of carboplatin within the polymer matrix and drastically increases the drug retention in the ablated tissue volume (over 3-fold difference) resulting in a higher average dose to the surrounding tissue. At 1.6 mm from the implant boundary, carboplatin concentration is significantly higher in ablated tissue at 48, 96, and 144 hours (P <.05), and reaches 4.7 mg/mL in ablated tissue at 48 hours. In comparison, the concentration in normal liver at 1.6 mm reaches only 0.7 mg/mL at the same time point. The drug penetrates 3.1 mm in ablated liver compared with 2.3 mm in normal liver also at 48 hours. After 144 hours, the drug is still detected at 3.1 mm in ablated liver but not in normal liver. The differences are significant (P <.05) at both 48 and 144 hours. Correlation with chemical analysis suggests that CT data accurately predicts the drug pharmacokinetics in both ablated and normal livers. CONCLUSION: This work shows that X-ray CT imaging is a useful and promising technique for in vivo monitoring of the release kinetics of locally delivered radiopaque agents.

Animals↗

Quantitative image quality evaluation of pixel-binning in a flat-panel detector for x-ray fluoroscopy.

X-ray fluoroscopy places stringent design requirements on new flat-panel (FP) detectors, requiring both low-noise electronics and high data transfer rates. Pixel-binning, wherein data from more that one detector pixel are collected simultaneously, not only lowers the data transfer rate but also increases x-ray counts and pixel signal-to-noise ratio (SNR). In this study, we quantitatively assessed image quality of image sequences from four acquisition methods; no-binning and three types of binning; in synthetic images using a clinically relevant task of detecting an extended guidewire in a four-alternative forced-choice paradigm. Binning methods were conventional data-line (D) and gate-line (G) binning, and a novel method in which alternate frames in an image sequence used D and G binning. Two detector orientations placed the data lines either parallel or perpendicular to the guide wire. At a low exposure of 0.6 microR (1.548 x 10(-10) C/kg) per frame, irrespective of detector orientation, D binning with its reduced electronic noise was significantly (p<0.1) better than the other acquisition methods. On average, alternate binning performed better than G binning. At a higher exposure of 4.0 microR (10.32 x 10(-10) C/kg) per frame, with data lines parallel to the guidewire, detection with D binning was significantly (p<0.1) better than G binning. However, with data lines perpendicular to the guidewire, G binning was significantly (p<0.1) better than D binning because the partial area effect was reduced. Alternate binning was the best binning method when results were averaged over both orientations, and it was as good as the best binning method at either orientation. In addition, at low and high exposures, alternate binning gave a temporally fused image with a smooth guidewire, an important image quality feature not assessed in a detection experiment. While at high exposure, detection with no binning was as good, or better, than the best binning method, it might be impractical at fluoroscopy imaging rates. A computational observer model based on signal detection theory successfully fit data and was used to predict effects of similar acquisition methods. Results from this study suggest the use of exposure-dependent detector binning in fluoroscopy that switches between D binning and alternate binning at low and high exposures, respectively.

Fluoroscopy↗

Three-dimensional comparison of interventional MR radiofrequency ablation images with tissue response.

OBJECTIVE: Solid tumors are being treated using radiofrequency (RF) ablation under interventional magnetic resonance imaging (MRI) guidance. We are investigating the ability of MRI to monitor ablation treatments by comparing MR images of thermal lesions to histologically assayed tissue damage. MATERIAL AND METHODS: An open MRI system was used to guide an ablation electrode into five rabbit thigh muscles and acquire post-ablation MR image volumes. We developed a methodology using a 3D computer registration to make spatial correlations. After MR and histology images were registered with an accuracy of 1.32+/-0.39 mm (mean+/-SD), a boundary of necrosis identified in the histology was compared with the outer boundary of the hyperintense region in MR images. RESULTS: For 14 T2-weighted MR images, the absolute distance between boundaries was 0.96+/-0.34 mm (mean+/-SD). Since the small discrepancy between boundaries is comparable to our registration accuracy, the boundaries may match exactly. Similar correlations to histology were obtained with a deformable model segmentation method. CONCLUSIONS: This is good evidence that MR thermal lesion images can be used during RF ablation treatments to accurately localize the zone of necrosis at the lesion margin.

Animals↗

Keyhole Dixon method for faster, perceptually equivalent fat suppression.

PURPOSE: To reduce the acquisition time associated with the two-point Dixon fat suppression technique by combining a keyhole in-phase (Water + Fat) k-space data set with a full out-of-phase (Water - Fat) k-space data set and optimizing the keyhole size with a perceptual difference model. MATERIALS AND METHODS: A set of keyhole Dixon images was created by varying the number of lines in the keyhole data set. Off-resonance correction was incorporated into the image reconstruction process to improve the homogeneity of the fat suppression. A perceptual difference model (PDM) was validated with human observer experiments and used to compare the keyhole images to images from a full two-point Dixon acquisition. The PDM was used to determine the smallest keyhole width required to obtain perceptual equivalence to images obtained from the full two-point Dixon method. RESULTS: In experimental phantom studies, the keyhole Dixon image reconstructed from 96 of 192 Water + Fat k-space lines and 192 Water - Fat k-space lines was perceptually equivalent to the full (192 + 192) two-point Dixon images, resulting in a 25% reduction in scan time. Clinical images of a volunteer's knee, orbits, and abdomen created from the smallest, perceptually equivalent keyhole width resulted in a 27%-38% reduction in total scan time. CONCLUSION: This method improves the temporal efficiency of the conventional two-point Dixon technique and may prove especially useful for high-field systems where specific absorption rate (SAR) limits will constrain radiofrequency (RF)-based fat suppression techniques.

Adipose Tissue↗

Three-dimensional method for comparing in vivo interventional MR images of thermally ablated tissue with tissue response.

PURPOSE: To investigate the ability of magnetic resonance (MR) to monitor radio-frequency (RF) ablation treatments by comparing MR images of thermal lesions to histologically assayed cellular damage. We developed a new methodology using three-dimensional registration for making spatial correlations. MATERIALS AND METHODS: A low-field, open MRI system was used to guide an ablation probe into rabbit thigh muscle and acquire MR volumes after ablation. After fixation, we sliced and photographed the tissue at 3-mm intervals, using a specially designed apparatus, to obtain a volume of tissue images. Histologic samples were digitized using a video microscopy system. For our three-dimensional registration method, we used the tissue images as the reference, and registered histology and MR images to them using two different computer alignment steps. First, the MR volume was aligned to the volume of tissue images by registering needle fiducials placed near the tissue of interest. Second, we registered the histology images with the tissue images using a two-dimensional warping technique that aligned internal features and the outside boundary of histology and tissue images. RESULTS: The MR and histology images were very well aligned, and registration accuracy, determined from displacement of needle fiducials, was 1.32 +/- 0.39 mm (mean +/- SD), which compared favorably to the MR voxel dimensions (0.70 mm in-plane and 3.0 mm thick). A preliminary comparison of MR and tissue response showed that the region inside the elliptical hyperintense rim in MR closely corresponds to the region of necrosis as established by histology, with a mean absolute distance between MR and histology boundaries of 1.17 mm, slightly smaller than the mean registration error. The MR region slightly overestimated the region of necrosis, with a mean signed distance between boundaries of 0.85 mm. CONCLUSION: Our results suggest that our methodology can be used to achieve three-dimensional registration of histology and in vivo MR images. In MR lesion images, the inner border of the hyperintense region corresponds to the border of irreversible cell damage. This is good evidence that during RF ablation treatments, iMRI lesion images can be used for real-time feedback.

Animals↗

Sub-acute changes in lesion conspicuity and geometry following MR-guided radiofrequency ablation.

PURPOSE: To evaluate MR signal and lesion zone volume evolution through the sub-acute phase following image-guided radiofrequency (RF) thermal ablation. MATERIALS AND METHODS: For many tissues, including muscle and liver, thermal lesions that result from RF heating have a characteristic two-boundary appearance featuring an inner core (zone I) surrounded by a hyper-intense margin (zone II) and normal tissue (zone III), found in both T(2) and contrast enhanced (CE) T(1)-weighted MR images, both immediately post-ablation and four days later. First, we compared corresponding points between manually segmented zone boundaries apparent in T(2)- and CE T(1)-weighted images. Second, we examined the contrast-to-noise ratio (CNR) between all zone combinations. Third, we quantified the volume of zone I, zone II, and the entire lesion using a three-dimensional lesion geometry model fitted to segmented images. RESULTS: On a slice-by-slice basis, no statistically significant differences were found between zone boundaries apparent in T(2) and CE T(1)-weighted images. The contrast to noise ratio (CNR) of zone I vs. zone II, zone I vs. background muscle, and zone II vs. background muscle was always equal or greater for T(2)-weighted images than for CE T(1)-weighted images. In addition, by day four, zone II significantly increased in intensity compared to background muscle. The median Zone I volume increase was 44.2% (42.6%) using T(2) weighted images and 55.5% (68.7% interquartile range) using CE T(1)- weighted images. This expansion likely corresponds to an enlargement of the ablated, coagulative necrosis, region. The median Zone II volume increase was 15.0% (42.6%) using T(2)- weighted images 1.5% (38.8%) using CE T(1)-weighted images. CONCLUSIONS: 1) There are no significant differences between the apparent zone boundaries in T(2)- and CE T(1)-weighted images; 2) CNR is equal or greater for T(2)-weighted images as compared to CE T(1)-images; and 3) both the inner and outer lesion zone volumes typically increase several days post-ablation.

Animals↗