PubMed Health⌕ Search

Biomedical subjects

David Laundy

Publications and source records attributed to David Laundy.

4 recordsLinked to original sources

A high-throughput structural biology/proteomics beamline at the SRS on a new multipole wiggler.

The North West Structural Genomics Centre's beamline, MAD10, at the SRS receives the central part of the radiation fan (0.5 mrad vertically, 4 mrad horizontally) produced by a new 2.46 T ten-pole wiggler. The optical arrangement of the beamline consists of a Rh-coated collimating Si mirror, a fixed-exit-beam double-crystal monochromator with sagittal bending for horizontal focusing and a second Rh-coated Si mirror for vertical focusing. The double-crystal Si (111) monochromator allows data collection in the 5-13.5 keV photon energy range with rapid (subsecond) tunability and high energy resolution. The monochromatic beam is optimized through a 200 microm collimator. The beamline end station has been designed around a Mar desktop beamline with high-throughput cryogenic sample changer, Mar225 CCD detector, liquid-N(2) autofill system and an ORTEC C-TRAIN-04 energy-resolving high-count-rate X-ray fluorescence detector. The instrument is optimized for MAD/SAD applications in protein crystallography with the additional mode of operation of online single-crystal EXAFS studies on the same crystals. Thus, screening of metals/Se in the crystal can be performed quickly prior to MAD/SAD data collection by exciting the crystal with X-rays of appropriate energy and recording an energy-dispersive fluorescence spectrum. In addition, this experimental set-up allows for parallel XAFS measurements on the same crystal to monitor 'radiation-induced' changes, if any, in e.g. the redox state of metal centres to be detected for a 'metallic' functional group during crystallographic data collection. Moreover, careful minimization of the thickness of the Be window maximizes the intensity performance for the 2.0-2.5 A softer wavelength range. This range also covers the K-edges of a number of important 3d transition metals as well as the L-edges of xenon and iodine and enhanced sulfur f ''.

Algorithms↗

Counting statistics of X-ray detectors at high counting rates.

Modern synchrotron radiation sources with insertion devices and focusing optics produce high fluxes of X-rays at the sample, which leads to a requirement for photon-counting detectors to operate at high counting rates. With high counting rates there can be significant non-linearity in the response of the detector to incident X-ray flux, where this non-linearity is caused by the overlap of the electronic pulses that are produced by each X-ray. A model that describes the overlap of detector pulses is developed in this paper. This model predicts that the correction to the counting rate for pulse overlap is the same as a conventional dead-time correction. The model is also used to calculate the statistical uncertainty of a measurement and predicts that the error associated with a measurement can be increased significantly over that predicted by Poisson (N(-1/2)) statistics. The error differs from that predicted by a conventional dead-time treatment.

Journal Article↗

Software for automatic calibration of synchrotron powder diffractometers.

An automatic procedure to calibrate angular-dispersive monochromatic diffraction instruments has been developed at the Daresbury Synchrotron Radiation Source. The procedure uses a macro Language to control the powder diffraction instruments to locate Bragg reflections and perform peak-centre refinement from a standard reference material. The information obtained is used to refine the wavelength of the radiation used and the angular offset of the detector arm. The concept and implementation of the new software are described with applications to demonstrate its viability. The results of a reliability and accuracy study are also presented.

Journal Article↗