Publications and source records attributed to David Luria.

13 recordsLinked to original sources

Mechanism of diastolic mitral regurgitation in candidates for cardiac resynchronization therapy.

It was hypothesized that restricted diastolic leaflet motion is implicated not only in the mechanism of systolic mitral regurgitation (MR) but also in the mechanism of diastolic MR observed in patients with severe heart failure. Cardiac resynchronization therapy (CRT) can oppose increased mitral leaflet tethering by increasing transmitral pressure, thereby providing an opportunity to explore this hypothesis. A total of 26 consecutive candidates for CRT with diastolic MR were compared with 26 candidates without diastolic MR. Maximal diastolic mitral leaflet opening and inflow direction and measures of mitral valve apparatus (i.e., mitral annular diameters, calculated mitral annular area, and tethering distance) were assessed from the apical 4-chamber view before and during CRT. There were no significant differences in New York Heart Association functional class, ejection fraction, QRS duration, PR interval, systolic MR grade, or 2-dimensional geometry of the mitral valve apparatus between the groups. Patients with diastolic MR had more restricted maximal diastolic leaflet openings (54 degrees +/- 17 degrees vs 71 degrees +/- 11 degrees , p = 0.003) and substantially smaller inflow angles (66 degrees +/- 7 degrees vs 79 degrees +/- 9 degrees , p = 0.0003) compared with patients without diastolic MR. After the institution of CRT, diastolic MR was eliminated in all patients, although there were no significant changes in any of the parameters of mitral valve apparatus. In conclusion, abnormal mitral valve tethering is a constitutive element of the mechanism of diastolic MR in patients with left ventricular dysfunction. Its acute resolution after CRT does not seem to be caused by changes in mitral valve geometry but rather by an increase in transmitral closing forces.

Cardiac Pacing, Artificial↗

Improvement of congestive heart failure by upgrading of conventional to resynchronization pacemakers.

AIMS: To compare the clinical response of patients with right ventricular apical pacing (RVAP) upgraded to cardiac resynchronization therapy (CRT) to that of previously nonpaced heart failure (HF) patients who had de novo CRT implantation. BACKGROUND: The role of CRT in patients with wide QRS and HF due to RVAP is less well established than in other CRT candidates. METHODS: Ninety-eight consecutive patients with CRT were studied (mean age 70, mean ejection fraction 0.23). Group A: patients having RVAP prior to CRT implantation (n = 25), group B: patients without prior RVAP (n = 73). Clinical and echocardiographic parameters were recorded prior to, and 3 months after, CRT implantation. RESULTS: Group A patients had a wider QRS at baseline compared to group B (203 +/- 32 ms vs 163 +/- 30 ms respectively, P < 0.001), and a shorter 6-minute walking distance (222 +/- 118 m vs 362 +/- 119 m, respectively, P < 0.005). Otherwise, clinical and echocardiographic parameters were not different. At follow up, group A patients had an average 0.7 +/- 0.5 decrease in their NYHA functional class, compared to 0.3 +/- 0.7 in group B patients (P < 0.05). Six-minute walking distance increased by 93 +/- 113 m in group A, versus 36 +/- 120 m in group B (P = 0.22). There was no difference in echocardiographic response to CRT between the groups. CONCLUSIONS: HF patients with prior RVAP demonstrate clinical improvement after upgrading to CRT that is comparable, and in some aspects, even better than that observed in HF patients with native conduction delay who undergo de novo CRT implantation.

Aged↗

Mid-term results of the 'hybrid maze': a combination of bipolar radiofrequency and cryoablation for surgical treatment of atrial fibrillation.

BACKGROUND AND AIM OF THE STUDY: Although the use of new sources of energy for the ablation of atrial fibrillation (AF) has simplified the procedure, concerns have been expressed with regard to the safety and efficacy of the various devices. Herein are described the results of a technique using a combination of bipolar radiofrequency (RF) and cryoablation. METHODS: Between February 2004 and August 2005, the combined procedure was used on 60 patients, 32 of whom (54%) had persistent AF, and 28 (46%) permanent AF. Lesions set similar to the Maze III procedure were used, with the addition of a right atrial isthmus lesion in the area of the coronary sinus and without right atrial appendage amputation and septal lesion. RESULTS: There were no operative complications and no death or major morbidity. The mean duration of the ablation procedure was 30 min (range: 27-36 min) for biatrial procedures, and 16 min (range: 15-19 min) for left atrial procedures. Forty-two patients (70%) were discharged in sinus rhythm. On completion of follow up, 48 patients (80%) were in sinus rhythm. Among 45 patients treated with cryoablation rather than monopolar RF, 89% were in sinus rhythm at the mean follow up of nine months. The predictor for recurrent post-procedural AF was preoperative permanent AF for more than 10 years' duration (p = 0.039), while that for postoperative atypical flutter was use of the monopolar RF ablator rather than the cryoablator (p = 0.001). CONCLUSION: The use of a bipolar RF device with the cryoprobe is an appealing combination which enables the Maze III lesion set to be completed in a straightforward, safe, and efficient manner.

Adult↗

Atrial fibrillation in dobutamine stress echocardiography.

OBJECTIVES: To describe the incidence of atrial fibrillation induced by dobutamine stress echocardiography and characterize patients at risk of developing atrial fibrillation, by constructing a simple validated risk score index. DESIGN: An observational study using prospectively collected data. METHODS: 3800 consecutive patients in sinus rhythm undergoing dobutamine stress echocardiography were randomly divided to a case (2/3) and test group (1/3). Associations of predetermined demographic, clinical, electrocardiographic and echocardiographic variables were calculated in patients with and without atrial fibrillation induced by dobutamine stress echocardiography in the case group. Logistic regression analysis determined significant independent risk predictors, a scoring index was constructed and validated on the test group. RESULTS: There was a 2% incidence of dobutamine stress echocardiography-induced atrial fibrillation in the study population. Risk predictors of atrial fibrillation included: a history of atrial fibrillation (2 points), increased left atrial diameter, right bundle branch block, decreased rest heart rate and hypertension (1 point each). The case subgroup low-risk patients (score 0-2) had a 1% risk, moderate-risk patients (score 3) a 2.7% and high-risk patients (score 4-6) a 14.5% risk of developing atrial fibrillation during dobutamine stress echocardiography. The rates in the test subgroup were 1%, 3.8% and 15.3%, respectively. CONCLUSION: Atrial fibrillation during dobutamine stress echocardiography is not common, the risk of developing atrial fibrillation during dobutamine stress echocardiography can be predicted by using a simple risk score system comprised of clinical, electrocardiographic and rest echocardiographic variables, which may be of help when planning a dobutamine stress echocardiography test in selected cases.

Aged↗

Long-term performance of screw-in atrial pacing leads: a randomized comparison of J-shaped and straight leads.

OBJECTIVE: In this prospective, randomized, control study we compared performance of J-shaped (JL) and straight atrial leads (SL) with active (screw-in) fixation mechanism, over a 5-year follow-up period. SUBJECTS AND METHODS: A total of 208 consecutive patients were randomized for implantation with a Medtronic 4568 JL model (n = 103) versus a Medtronic 4068 SL model (n = 105), and all lead-related measurements and complications were recorded. RESULTS: Lead-related complications occurred in JL and SL with similar frequency (6% and 9%, respectively, P = 0.45). Lead dislodgment occurred in 8 (7.8%) cases in SL versus none in JL (P = 0.004). Lead malfunction and excessive pacing thresholds without macrodislodgment occurred more frequently in JL (11; 10.7%) than in SL (4; 3.8%), P = 0.055. Lead material failure (insulation break) occurred only once in SL at the 5-year checkup. Most complications occurred during the first year after implantation. Other events occurred in both leads with similar frequency and included: death in 39 and 35, loss of follow-up in 8 and 6, and development of atrial fibrillation in 9 and 15 patients, respectively. Of those who completed follow-up, lead impedance and pacing threshold increased significantly in both groups. P wave decreased in SL but not in JL. CONCLUSION: More dislocations occurred in SL, but were counterbalanced by more lead malfunctions and excessive pacing thresholds in the JL group. Both leads demonstrated minor deterioration in electrical measurements during follow-up, with only 1 case of lead material failure in SL. Overall, both groups demonstrated favorable lead performance throughout follow-up.

Aged↗

Programmable multiple pacing configurations help to overcome high left ventricular pacing thresholds and avoid phrenic nerve stimulation.

BACKGROUND: High left ventricular pacing (LVP) thresholds and phrenic nerve stimulation (PNS) are common problems with cardiac resynchronization (CRT). Newer systems capable of multiple LVP configurations may help overcome these problems without the need for reoperation. METHODS: CRT systems capable of multiple LVP configurations (Guidant models H155 and H145) were implanted in 43 patients (study group). An additional 49 patients (control group) received CRT systems (Guidant, Medtronic, Biotronik, St. Jude Medical, various models) lacking this feature. RESULTS: Overall, acute high (> or =2.5 V/0.5 ms) LVP thresholds were encountered in 13 (30%) of the study group, and 25 (50%) of control group patients (P = 0.03). PNS was encountered in 5 (12%) of the study group and 12 (24%) of control group patients (P = 0.13). All cases of high LVP thresholds and PNS in the study group were managed by switching to a different LVP configuration, while high thresholds remained in control group patients, and PNS was managed by replacing the lead. The CS lead was successfully placed in a lateral branch in 95% of study group, compared to only 77% of control group patients (P = 0.004). CONCLUSIONS: Multiple LVP configurations were clinically useful in a significant number of patients undergoing CRT system implantation by helping to overcome high LVP thresholds and PNS, and by providing more flexibility in placing the LV lead.

Aged↗

A novel form of familial bidirectional ventricular tachycardia.

We evaluated a family with 30 members, 3 of whom had incessant polymorphous and bidirectional ventricular tachycardia (VT) that was electrocardiographically similar to that described in other familial polymorphic VT series; the VT was unrelated to exercise and asymptomatic. More subtle, but morphologically similar, ventricular arrhythmias were detected in 3 other family members. Genes related to intracellular calcium transport were specifically excluded.

Adult↗

Use of automatic threshold tracking function with non-low polarization leads: risk for algorithm malfunction.

The AutoCapture (AC) function of new pacemakers (PM) from St Jude Medical (SJM) was originally recommended for use with low polarization (LP) ventricular leads only.However, recent reports have encouraged the use of the AC function with various leads, including those lacking a special LP design. The objective of this study was to analyze the reliability and safety of the AC algorithm application with different types of pacing leads. The study group comprised 30 consecutive patients with AC PMs connected to three different types of non-LP leads. Ten patients with SJM LP leads served as the control group. The study protocol included a complete AC function test using four different pulse widths (PW). The pacing threshold was independently assessed by a manual/semiautomatic check. Erratic behavior of polarization measurements with increasing PWs was demonstrated in 43% (n = 13) of the study group. Invalid polarization measurements resulted in erroneous algorithm recommendation to apply AC function in 17% (n = 5) of the study patients. Subsequent AC function activation lead to incorrect threshold determination due to missed noncapture in three patients. AC function should be applied with caution with non-LP leads. "Off label" use of these leads may cause erroneous polarization signal measurements which, in some cases, may result in incorrect pacing threshold determination, rendering a potential risk to dependent patients.

Algorithms↗

Pericarditis following permanent pacemaker insertion.

BACKGROUND: The appearance of pericarditis following insertion of a permanent pacemaker is not widely acknowledged in the literature. OBJECTIVES: To describe our experience with pericarditis following 395 permanent pacemaker implantations over 2 years. METHODS: We retrospectively reviewed the medical records of 395 consecutive patients in whom new pacing systems or pacemaker leads had been implanted over a 2 year period. We searched the records for pericarditis that developed within 1 month after pacemaker implantation according to the ICD-9 code. The incidence, clinical picture, response to treatment, and relationship to lead design and location were studied. RESULTS: Eight cases (2%) of pericarditis following implantation were detected. Clinical manifestations in all patients were similar to those of post-pericardiotomy syndrome and included chest pain (n = 7), friction rub (n = 1), fever (n = 2), fatigue (n = 2), pleural effusion (n = 2), new atrial fibrillation (n = 2), elevated erythrocyte sedimentation rate (n = 4), and echcardiographic evidence of pericardial effusion (n = 8). All affected patients had undergone active fixation (screw-in) lead implantation in the atrial position. The incidence of pericarditis with screw-in atrial leads was 3% compared to 0% in other cases (P < 0.05). CONCLUSIONS: Pericarditis is not uncommon following pacemaker implantation with active fixation atrial leads. Special attention should be paid to identifying pericardial complications following pacemaker implantation, especially when anticoagulant therapy is resumed or initiated. The use of passive fixation leads is likely to reduce the incidence of pericarditis but this issue should be further investigated.

Adrenal Cortex Hormones↗

Managing pacemaker safety alerts: experience with three successive models of a single manufacturer.

This report describes the experience of a large pacemaker center during three successive replacement operations due to safety alerts involving three models from the same manufacturer. Between March 1993 and May 1999, 210 patients were implanted with three DDD pacemaker models (Sorin Biomedica, Saluggia, Italy) that were subsequently subject to safety alerts. Pacemaker records were reviewed for complications related to device malfunction, and those secondary to the replacement procedure. Pacemaker malfunction was observed in 16.4% of units despite much lower estimates from the company (range 1-4%). With the exception of one, all units were replaced. Malfunctions were discovered in 7 of 20 pacemakers following an urgent call for follow-up issued as a result of the alert. Twenty units implanted as substitutes for those replaced following the first alert turned out to be subject to the third alert. Significant clinical consequences of malfunction occurred in 5.3% of patients including a near fatal event in one case, while complications related to the replacement procedure occurred in 8.3% of patients, including one fatality. On the issuance of a safety alert, failure rates in a particular center may be higher than published by the manufacturer, and should prompt action by the center to weigh local incidence of device failure against complications of replacement procedures. When device failure mechanism is not entirely clear, particularly in cases of successive model failures, replacement devices from a different manufacturer should be considered.

Adolescent↗

Progressive isthmus delay during atrial flutter ablation: the critical importance of isthmus spanning electrodes for distinguishing pseudoblock from block.

Bidirectional isthmus block is associated with successful atrial flutter ablation, whereas creation of increased isthmus conduction delay without block can be proarrhythmic. Often, halo catheter electrodes fail to provide adequate sub-Eustachian isthmus recordings. The aim of this study was to determine if progressive isthmus conduction delay results in the false appearance of block during atrialflutter ablation. A 20-pole deflectable catheter was prospectively positioned across the sub-Eustachian isthmus (from the coronary sinus os [CSO] to 7:00 on the tricuspid valve annulus [TVA] clock face in the left anterior oblique [LAO] projection) in nine patients undergoing atrial flutter ablation. During sinus rhythm, conduction time was measured from the CSO to the 7:00 position while pacing the CSO. Measurements were repeated after each linear lesion and after conduction block was achieved. Transisthmus conduction time at baseline, just prior to success, and after the presence of complete block was 54 +/- 9, 123 +/- 39, and 155 +/- 30 ms, respectively (P < or = 0.01). The marked delay prior to complete block resulted in reversal of the activation sequence in electrodes at TVA 7:00, creating the false appearance of isthmus block; the isthmus electrodes clearly distinguished delay from block. Catheter ablation results in progressive isthmus conduction delay prior to the creation of complete block. Electrodes spanning the isthmus and line of block are critical for distinguishing conduction delay (and pseudoisthmus block) from block.

Adult↗

Multiple pulse generator malfunctions with a dual chamber pacemaker.

The aim of this study was to evaluate the dual chamber uni/bipolarpacemaker Minidual 50, manufactured by Sorin Biomedica. Between 1995 and 1998, 66 Minidual 50 models were implanted at the Heart Institute. During the follow-up period of 33 +/- 12.8 months (range 0-50 months), total function loss in seven (10.6%) units and false threshold measurement of sensing and pacing in three (4.5%) patients were observed. Average time from implantation to malfunction was 37 months (range 28-42). Malfunction was unrelated to battery status and could not be predicted by any measures obtained during the pacemaker follow-up period. Kaplan Meyer survival curve predicted a 70% 4-year malfunction-free survival of that pacemaker model. Given this high rate of total malfunction and the unpredictable nature of its occurrence, the authors recommend the replacement of all remaining Minidual 50 units at risk, at least in dependent patients.

Adult↗