PubMed Health⌕ Search

Biomedical subjects

David M Gauntt

Publications and source records attributed to David M Gauntt.

2 recordsLinked to original sources

A novel technique to suppress grid line artifacts.

It has been established that coarse strip density, air-interspace grid systems can suppress scatter in general radiography and in mammography more effectively than conventional high strip density grids. However, such systems have never gained clinical acceptance due to the large distance the grid needs to move to suppress gridline artifacts and due to their corresponding bulk. We present a novel technique for suppressing grid lines using an x-ray exposure wave form with a soft start and soft stop. The wave form is achieved by varying the x-ray tube current during the exposure. We derive the conditions that the time dependence of the x-ray exposure output needs to meet to suppress gridline artifacts with only a modest grid movement. The technique allows for the design of compact coarse strip density grid systems. We present experimental results that demonstrate the feasibility of the technique.

Algorithms↗

Grid line artifact formation: A comprehensive theory.

Linear focused grids are commonly used in general radiography and mammography to control scatter. In these applications, if lines would be visible when the grid was stationary, then the grid is moved during the x-ray exposure to blur out grid lines. Presented is a theoretical framework for estimating grid line artifact magnitude and evaluating artifact suppression techniques. The framework takes as parameters the grid pitch, septum thickness, and exposure time, and allows for a variation in grid velocity and in x-ray tube output during the exposure. Grid line artifacts are evaluated for a variety of conditions. These include a stationary grid, a grid moving at a constant velocity with no kV ripple, a grid moving at a constant velocity with large kV ripple, and a grid moving with decreasing velocity and no kV ripple. Also evaluated are grid line artifacts for a novel suppression technique in which the grid moves at a constant velocity and the x-ray exposure waveform is "feathered," i.e., when the x-ray exposure waveform has a soft start and stop. Of practical interest is that it is possible to effectively eliminate grid line artifacts when the grid moves only a short distance with an appropriately "feathered" exposure waveform. This capability permits one to design efficient and compact coarse strip density grid systems.

Algorithms↗