PubMed Health⌕ Search

Biomedical subjects

David M Lubman

Publications and source records attributed to David M Lubman.

32 records · Page 2Linked to original sources

Identification of low molecular weight proteins isolated by 2-D liquid separations.

Proteins with molecular mass (M(r)) <20 kDa are often poorly separated in 2-D sodium dodecyl sulfate polyacrylamide gel electrophoresis. In addition, low-M(r) proteins may not be readily identified using peptide mass fingerprinting (PMF) owing to the small number of peptides generated in tryptic digestion. In this work, we used a 2-D liquid separation method based on chromatofocusing and non-porous silica reversed-phase high-performance liquid chromatography to purify proteins for matrix-assisted laser desorption/ionization time-of-flight mass spectrometric (MALDI-TOFMS) analysis and protein identification. Several proteins were identified using the PMF method where the result was supported using an accurate M(r) value obtained from electrospray ionization TOFMS. However, many proteins were not identified owing to an insufficient number of peptides observed in the MALDI-TOF experiments. The small number of peptides detected in MALDI-TOFMS can result from internal fragmentation, the few arginines in its sequence and incomplete tryptic digestion. MALDI-QTOFMS/MS can be used to identify many of these proteins. The accurate experimental M(r) and pI confirm identification and aid in identifying post-translational modifications such as truncations and acetylations. In some cases, high-quality MS/MS data obtained from the MALDI-QTOF spectrometer overcome preferential cleavages and result in protein identification.

Breast Neoplasms↗

A two-dimensional liquid-phase separation method coupled with mass spectrometry for proteomic studies of breast cancer and biomarker identification.

A two-dimensional liquid-phase separation scheme coupled with mass spectrometry (MS) is presented for proteomic analysis of cell lysates from normal and malignant breast epithelial cell lines. Liquid-phase separations consist of isoelectric focusing as the first dimension and nonporous silica reverse-phase high-performance liquid chromatography (NPS-RP-HPLC) as the second dimension. Protein quantitation and mass measurement are performed using electrospray ionization-time of flight MS (ESI-TOF MS). Proteins are identified by peptide mass fingerprinting using matrix-assisted laser desorption ionization-time of flight MS (MALDI-TOF MS) and MALDI-quadrupole time of flight (QTOF)-tandem mass spectrometry (MS/MS). Two pH regions with 50-60 unique proteins in each pH range were chosen for analysis. Mass maps were created that allowed visualization of protein quantitation differences between normal and malignant breast epithelial cells. Of the approximately 110 unique proteins observed from mass mapping experiments over the limited pH range, 40 (36%) were positively identified by peptide mass fingerprinting and assigned to bands in the mass maps. Of these 40 proteins, 22 were more highly expressed in one or more of the malignant cell lines. These proteins represent potential breast cancer biomarkers that could aid in diagnosis, therapy, or drug development.

Biomarkers, Tumor↗

Comprehensive proteome analysis of ovarian cancers using liquid phase separation, mass mapping and tandem mass spectrometry: a strategy for identification of candidate cancer biomarkers.

A two-dimensional (2-D) liquid phase separation method, liquid isoelectric focusing followed by nonporous reversed-phase high performance liquid chromatography (HPLC), was used to separate proteins from human ovarian epithelial whole cell lysates. HPLC eluent was interfaced on-line to an electrospray ionization (ESI) time of flight (TOF) mass spectrometer to obtain accurate intact protein molecular weights (Mr). 2-D protein expression maps were generated displaying protein isoelectric point (pI) versus intact protein Mr. Resulting 2-D images effectively displayed quantitative differential protein expression in ovarian cancer cells versus non-neoplastic ovarian epithelial cells. Protein peak fractions were collected from the HPLC eluent, enzymatically digested, and analyzed by matrix-assisted laser desorption/ionization (MALDI) TOF-mass spectrometry (MS) peptide mass fingerprinting and by MALDI-quadrupole TOF tandem mass spectrometry peptide sequencing. Interlysate comparisons of differential protein expression between two ovarian adenocarcinoma cell lines, ES2 and MDAH-2774, and ovarian surface epithelial cells was performed. Five pI fractions from each sample were selected for comparative study and over 300 unique proteins were positively identified from the 2-D liquid expression maps using MS, which covered around 60% of proteins detected by on-line ESI-TOF-MS. This represents one of the most comprehensive proteomic analyses of ovarian cancer samples to date. Protein bands with significant up- or down-regulation in one cell line versus another as viewed in the 2-D expression maps were identified. This strategy may prove useful in identifying novel ovarian cancer marker proteins.

Biomarkers, Tumor↗

Identification of metastasis-associated proteins in a human tumor metastasis model using the mass-mapping technique.

For most cancer cell types, the acquisition of metastatic ability leads to clinically incurable disease. The identification of molecules whose expression is specifically correlated with the metastatic spread of cancer would facilitate the design of therapeutic interventions to inhibit this lethal process. In order to facilitate metastasis gene discovery we have previously characterized a pair of monoclonal cell lines from the human breast carcinoma cell line MDA-MB-435 that have different metastatic phenotypes in immune-compromised mice. In this study, serum-free conditioned media was collected from the cultured monoclonal cell lines and a mass mapping technique was applied in order to profile a component of each cell line proteome. We utilized chromatofocusing in the first dimension to obtain a high resolution separation based on protein pI, and nonporous silica reverse-phase high performance liquid chromatography was used for the second dimension. Selected proteins were identified on the basis of electrospray ionization time of flight mass spectrometry (ESI-TOF MS) intact protein mapping and matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) peptide mass fingerprinting. Using this approach we were able to map over 400 proteins and plot them as a 2-D map of pI versus accurate M(r). This was performed over a pI range of 4.0-6.2, and a mass range of 6-80 kDa. ESI-TOF MS data and further analysis using MALDI-TOF MS confirmed and identified 27 differentially expressed proteins. Proteins associated with the metastatic phenotype included osteopontin and extracellular matrix protein 1, whereas the matrix metalloproteinase-1 and annexin 1 proteins were associated with the non-metastatic phenotype. These findings demonstrate that the mass mapping technique is a powerful tool for the detection and identification of proteins in complex biological samples and which are specifically associated with a cellular phenotype.

Animals↗

High sequence coverage of proteins isolated from liquid separations of breast cancer cells using capillary electrophoresis-time-of-flight MS and MALDI-TOF MS mapping.

A method has been developed for high sequence coverage analysis of proteins isolated from breast cancer cell lines. Intact proteins are isolated using multidimensional liquid-phase separations that permit the collection of individual protein fractions. Protein digests are then analyzed by both matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) peptide mass fingerprinting and by capillary electrophoresis-electrospray ionization (CE-ESI)-TOF MS peptide mapping. These methods can be readily interfaced to the relatively clean proteins resulting from liquid-phase fractionation of cell lysates with little sample preparation. Using combined sequence information provided by both mapping methods, 100% sequence coverage is often obtained for smaller proteins, while for larger proteins up to 75 kDa, over 90% coverage can be obtained. Furthermore, an accurate intact protein MW value (within 150 ppm) can be obtained from ESI-TOF MS. The intact MW together with high coverage sequence information provides accurate identification. More notably the high sequence coverage of CE-ESI-TOF MS together with the MS/MS information provided by the ion trap/reTOF MS elucidates posttranslational modifications, sequence changes, truncations, and isoforms that may otherwise go undetected when standard MALDI-MS peptide fingerprinting is used. This capability is critical in the analysis of human cancer cells where large numbers of expressed proteins are modified, and these modifications may play an important role in the cancer process.

Amino Acid Sequence↗

A comparison of drug-treated and untreated HCT-116 human colon adenocarcinoma cells using a 2-D liquid separation mapping method based upon chromatofocusing PI fractionation.

A multidimensional chromatographic 2-D liquid-phase separation method has been developed for differential display of proteins from cell lysates and applied to a comparison of protein expression between Peninsularinone-treated and untreated HCT-116 human colon adenocarcinoma cells. The method involves fractionation according to pI using chromatofocusing with analytical columns in the first dimension followed by separation of the proteins in each pI fraction using nonporous reversed-phase HPLC. A 2-D map of the protein content of each cell line based upon pI versus hydrophobicity as detected by UV absorption was generated and a differential display map indicating the presence of up- or downregulated proteins displayed using ProteoVue and DeltaVue software. Using this method, > 1000 protein bands could be detected in 0.2 pH fractions over a pH range of 4-7. In addition, the liquid eluent from the separation was directed on-line into an electrospray TOF-MS to obtain an accurate molecular weight of the intact proteins. An accurate molecular weight together with the peptide map was used to obtain protein identification using database searching. The method has been shown to have high reproducibility for quantitative differential display analysis of interlysate comparisons, generation of accurate protein identifications, and ease of data interpretation. It has been used herein to identify proteins that change as a function of drug treatment. The relative simplicity of the current procedure and the potential for full automation will make this technique an essential tool in future proteomic studies.

Adenocarcinoma↗

Electrophoretic mobility for peptides with post-translational modifications in capillary electrophoresis.

Several semiempirical models for peptide electrophoretic mobility have been tested for capillary electrophoresis (CE) separation with a positively charged capillary using on-line CE combined with electrospray ionization-mass spectrometry (ESI-MS). In the current system with pH 2.7, the expression q/M(0.56) provided the best correlation with the electrophoretic mobility in the analysis of a set of 18 standard samples, where q is the calculated net charge and M is the molecular weight. The peptides resulting from various digests of horse heart myoglobin or bovine hemoglobin were used to demonstrate the validity of this correlation. Post-translationally modified peptides from tryptic digest of human myelin basic protein were also investigated and were found to provide excellent correlation with the linear plot when the total charge of the peptide was correctly calculated. If the total charge was not properly calculated then the post-translationally modified peptides fell off the linear plot. Using this method five arginine residues (residues 5, 49, 54, 97 and 130) were found to be partially citrullinated, four glutamine residues (residues 8, 103, 121 and 147) were found to be partially deamidated and both methionines at residues 21 and 167 were found to be partially oxidized. Three peptides were found with phosphorylation; TPPPSQGK (residue 98 to 105), FSWGAEGQR (residue 114 to 122), and SGSPMAR (residue 163 to 169) and Arginine at 107 was found to be partially monomethylated or dimethylated. The method may provide an excellent means of identifying the presence of peptides with post-translational modifications in conjunction with MS.

Amino Acid Sequence↗

Protein microarrays using liquid phase fractionation of cell lysates.

We describe an approach in which protein microarrays are produced using a two-dimensional (2-D) liquid phase fractionation of cell lysates. The method involves a pI-based fractionation using chromatofocusing in the first dimension followed by nonporous reversed-phase high-performance liquid chromatography (HPLC) of each pI fraction in the second dimension. This allows fractionation of cellular proteins in the liquid phase that could then be arrayed on nitrocellulose slides and used to study humoral response in cancer. Protein microarrays have been used to identify potential serum biomarkers for prostate cancer. It is shown that specific fractions are immunoreactive against prostate cancer serum but not against serum from healthy individuals. These proteins could serve as sero-diagnostic markers for prostate cancer. Importantly, this method allows for use of post-translationally modified proteins as baits for detection of humoral response. Proteins eliciting an immune response are identified using the molecular mass and peptide sequence data obtained using mass spectrometric analysis of the liquid fractions. The fractionation of proteins in the liquid phase make this method amenable to automation.

Automation↗

Profiling the progression of cancer: separation of microsomal proteins in MCF10 breast epithelial cell lines using nonporous chromatophoresis.

The heterogeneity of cellular protein expression has stimulated development of separations targeting smaller groups of related proteins rather than entire proteomes. The following work describes the development of a technique for the characterization of membrane subproteomes from five different breast epithelial cell lines. Intact membrane proteins are separated by hydrophobicity in the first dimension using nonporous reversed-phase high-performance liquid chromatography (RP-HPLC) to generate unique chromatographic profiles. Fractions of eluent are further separated using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) to create distinct banding patterns. This hybrid liquid phase/gel phase method circumvents issues of membrane protein precipitation and provides a simple strategy aimed at isolating and characterizing a traditionally underrepresented protein class. Membrane protein profiles are created that discriminate between microsomal fractions of breast epithelial cells in different stages of neoplastic progression. Proteins are subsequently identified using matrix-assisted laser desorption/ionization - mass spectrometry (MALDI-MS) mass fingerprinting and MALDI-quadrupole time of flight - tandem mass spectrometry (QTOF-MS/MS) peptide sequencing. Furthermore, as this strategy preserves intact protein structure, further characterization can be performed on proteins producing mass fingerprint spectra and fragmentation spectra that did not result in database protein identifications. The coupling of nonporous RP-HPLC with SDS-PAGE provides a useful alternative to two-dimensional PAGE (2-D-PAGE) for membrane protein analysis.

Breast↗

Two-dimensional liquid chromatography protein expression mapping for differential proteomic analysis of normal and O157:H7 Escherichia coli.

A multidimensional chromatographic method has been applied for the differential analysis of proteins from different strains of Escherichia coli bacteria. Proteins are separated in the first dimension using chromatofocusing (CF) and further separated by nonporous reversed-phase high-performance liquid chromatography (NPS-RP-HPLC) in the second dimension. A 2-dimensional (2-D) expression map of bacterial protein content is created for virulent O157:H7 and nonvirulent E. coli strains depicting protein isoelectric point (pI) versus protein hydrophobicity. Differentially expressed proteins are further characterized using electrospray/ionization time-of-flight mass spectrometry (ESI-TOF-MS) for intact protein molecular weight (MW) determination and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) peptide mass fingerprinting for protein identification. Using this method, no significant differential protein expression is exhibited between the two O157:H7 strains examined over a pH range of 4.0-7.0, and O157:H7 strains could be distinguished from nonvirulent E. coli. Several proteins differentially expressed between O157:H7 and nonvirulent E. coli are identified as potential markers for detection and treatment of O157:H7 infection.

Bacterial Proteins↗

Two-dimensional liquid separations-mass mapping of proteins from human cancer cell lysates.

A review of two-dimensional (2D) liquid separation methods used in our laboratory to map the protein content of human cancer cells is presented herein. The methods discussed include various means of fractionating proteins according to isoelectric point (pI) in the first dimension. The proteins in each pI fraction are subsequently separated using nonporous (NPS) reversed-phase high-performance liquid chromatography (RP-HPLC). The liquid eluent of the RP-HPLC separation is directed on-line into an electrospray ionization time-of-flight (ESI-TOF) mass spectrometer where an accurate value of the protein intact M(r) can be obtained. The result is a 2D map of pI versus M(r) analogous to 2D gel electrophoresis; however the highly accurate and reproducible M(r) serves as the basis for interlysate comparisons. In addition, the use of liquid separations allows for the collection of hundreds of purified proteins in the liquid phase for further analysis via peptide mass mapping using matrix assisted laser desorption ionization TOF MS. A description of the methodology used and its applications to analysis of several types of human cancer cell lines is described. The potential of the method for differential proteomic analysis for the identification of biomarkers of disease is discussed.

Chromatography, High Pressure Liquid↗

Three-dimensional protein map according to pI, hydrophobicity and molecular mass.

A three-dimensional method has been developed to map the protein content of cells according to pI, M(w) and hydrophobicity. The separation of complex protein mixtures from cells is performed using isoelectric focusing (IEF) in the liquid phase in the first dimension, non-porous silica (NPS) RP-HPLC in the second dimension and on-line electrospray ionization (ESI) time-of-flight mass spectrometry (TOF-MS) detection in the third dimension. The experimentally determined pI, M(w) and hydrophobicity can then be used to produce a three-dimensional map of the protein expression of a cell, where now each protein can be tagged by three independent parameters. The ESI-TOF-MS provides an accurate M(w) for the intact protein while the hydrophobicity dimension results from the RP-HPLC component of the separation. The elution time, or percent acetonitrile at time of elution, of the protein is related to the hyrophobicity, which is an inherent property of the protein. 3D protein maps can thus be generated showing pI, M(w) and % acetonitrile at time of elution as well as pI, M(w) and hydrophobicity. The potential of the 3D plot for effective mapping of proteins from cells compared to current 2D methods is discussed.

Cell Line↗

A 2-D liquid separations/mass mapping method for interlysate comparison of ovarian cancers.

A two-dimensional liquid phase separation of proteins from whole cell lysates coupled on-line to an electrospray-ionization time-of-flight (ESI-TOF) mass spectrometer (MS) is used to map the protein content of ovarian surface epithelial cells (OSE) and an ovarian carcinoma-derived cell line (ES2). The two dimensions involve the use of liquid isoelectric focusing as the first phase and nonporous silica reversed-phase HPLC as the second phase of separation. Accurate molecular weight (MW) values are then obtained upon the basis of ESI-TOFMS so that an image of isolectric point (pI) versus MW analogous to 2-D gel electrophoresis is produced. The accurate MW together with the pI fraction and corresponding hydrophobicity (%B) are used to tag each protein so that protein expression can be compared in interlysate studies. Each protein is also identified on the basis of matrix-assisted laser desorption-ionization (MALDI) TOFMS peptide mapping and intact MW so that a standard map is produced against which other cell lines can be compared. Quantitative changes in protein expression are measured in these interlysate comparisons using internal standards in the on-line ESI-TOFMS process. In the ovarian epithelial cell lines under study, it is shown that in the three pI fractions chosen for detailed analysis, over 50 unique proteins can be detected per fraction, of which 40% can be identified from web-based databases. It is also shown that when using an accurate MW to compare proteins in the OSE versus ovarian cancer sample, there are proteins highly expressed in cancer cells but not in normal cells. In addition, many of the proteins in the cancer sample appear to be down-regulated, as compared to the normal cells. This two-dimensional (2-D) liquid/mass mapping method may provide a means of studying proteins in interlysate comparisons not readily available by other methods.

Adenocarcinoma, Clear Cell↗

A protein molecular weight map of ES2 clear cell ovarian carcinoma cells using a two-dimensional liquid separations/mass mapping technique.

A molecular weight map of the protein content of ES2 human clear cell ovarian carcinoma cells has been produced using a two-dimensional (2-D) liquid separations/mass mapping technique. This method uses a 2-D liquid separation of proteins from whole cell lysates coupled on-line to an electrospray ionization-time of flight (ESI-TOF) mass spectrometer to map the accurate intact molecular weight (M(r)) of the protein content of the cells. The two separation dimensions involve the use of liquid isoelectric focusing as the first phase and nonporous silica reversed-phase high-performance liquid chromatography (HPLC) as the second phase of separation. The detection by ESI-TOF-MS provides an image of pI versus M(r) analogous to 2-D gel electrophoresis. Each protein is then identified based upon matrix-assisted laser desorption/ionization (MALDI)-TOF-MS peptide mapping and intact M(r) so that a standard map is produced against which other ovarian carcinoma cell lines can be compared. The accurate intact M(r) together with the pI fraction, and peptide map serve to tag the protein for future interlysate comparisons. An internal standard is also used to provide a means for quantitation for future interlysate studies. In the ES2 cell line under study it is shown that nearly 900 M(r) bands are detected over 17 pI fractions from pH 4 to 12 and a M(r) range up to 85 kDa and that around 290 of these bands can be identified using mass spectrometric based techniques. The protein M(r) is detected within an accuracy of 150 ppm and it is shown that many of the proteins in this human cancer sample are modified compared to the database. The protein M(r) map may serve as a highly reproducible standard Web-based method for comparing proteins from related human cell lines.

Chromatography, High Pressure Liquid↗