Clinical surveillance of a tined, bipolar, silicone-insulated ventricular pacing lead.

AIMS: This study assesses short- and long-term performance of the S80TB ventricular lead manufactured by Sorin Biomedica, Italy. METHODS AND RESULTS: Three hundred and thirty leads were implanted and had complete follow-up with us for a minimum of 60 months or up to failure, removal, and/or patient death (mean 40 months, range: 1 day to 81 months). Thirty-two patients (9.6%) had spontaneous lead-related complications: 7 (2.1%) occurred during the first week; 25 (7.6%) had chronic complications, of which 20 (6.1%) necessitated re-operations; 3 (0.9%) were lead material failures. Of the 110 re-operations (90 pacemaker replacements and 20 operations due to complications), 7 additional cases (6.4%) were complicated by unique connector damage that occurred during disconnection of the lead from the connector block. The Kaplan-Meier estimated 5-year lead survival free of lead material failure and free of any significant lead complication were 97.9 and 87%, respectively. CONCLUSION: The S80TB lead demonstrates an acceptable rate of acute and chronic spontaneous complications and very few lead material failures over 5 years of follow-up. However, there seems to be a relatively high incidence of connector damage during disconnection from the connector block. Extra caution is required during those procedures in patients with this lead.

Adult↗

Acute blood pressure changes after the onset of atrioventricular nodal reentrant tachycardia: a time-course analysis.

INTRODUCTION: We aimed to characterize blood pressure (BP) response at the beginning of atrioventricular nodal reentrant tachycardia (AVNRT) and its relationship to orthostatic challenge and variable atrioventricular interval. METHODS AND RESULTS: In this prospective study of 17 consecutive patients with documented AVNRT, mean BP was analyzed in the supine and upright positions during sinus rhythm, AVNRT, and pacing with atrioventricular delay of 150 msec (AV150) and 0 msec (AV0). Mean BPs were compared at 3-5 seconds, 8-10 seconds, and 28-30 seconds after the onset of AVNRT or pacing. BP decreased immediately after AVNRT initiation, with gradual recovery during the first 30 seconds from 71.9 +/- 16.5 mmHg to 86 +/- 13.8 mmHg, P < 0.01. A similar pattern was observed during AV0, but not during AV150, pacing. While supine, mean BP decrease was more pronounced during AVNRT and AV0 pacing (-26.1% and -32.1%, respectively) than during AV150 pacing (-8%, P = 0.02 and P = 0.07, respectively). This difference subsided 30 seconds after the onset of AVNRT or pacing. When upright, the mean BP time course was similar, but mean BP recovery during AVNRT was slower, and the difference between mean BP during AVNRT and AV150 persisted at 30 seconds. CONCLUSIONS: The initial mean BP decrease during AVNRT recovered gradually within 30 seconds. A short atrioventricular interval is associated with a greater mean BP decrease at the onset of tachycardia. These observations may explain clinical symptoms immediately after the onset of AVNRT.

Adult↗

Upper limit of vulnerability determination during implantable cardioverter-defibrillator placement to minimize ventricular fibrillation inductions.

The defibrillation threshold (DFT) and upper limit of vulnerability (ULV) were determined using step-down protocols in 50 patients who underwent implantable cardioverter-defibrillator placement or testing. The sensitivity and specificity of each ULV energy level was assessed for detecting an increased DFT, correlation of the DFT and ULV, and optimal shock timing for ULV determination. A ULV <10 or 11 J (failure to induce ventricular fibrillation with 10- to 11-J shocks) was 100% predictive of an acceptable DFT and may be sufficient to exclude unacceptable DFTs in 60% of implantable cardioverter-defibrillator recipients. All 4 shocks used to scan the peak of the T wave during ULV testing were necessary for accurate ULV determination.

Aged↗

Long-term outcome of patients who received implantable cardioverter defibrillators for stable ventricular tachycardia.

INTRODUCTION: Evidence is inconclusive concerning the role of implantable cardioverter defibrillators (ICDs) to treat patients with hemodynamically stable ventricular tachycardia (VT). The goal of this study was to estimate future risk of unstable ventricular arrhythmias in patients who received ICDs for stable VT. METHODS AND RESULTS: We reviewed complete ICD follow-up data from 82 patients (age 66.1 +/- 11.3 years; left ventricular ejection fraction 32.3%+/- 11.2%; mean +/- SD) who received ICDs for stable VT. During the follow-up period of 23.6 +/- 21.5 months (mean +/- SD), 15 patients (18%) died, and 10 (12%) developed unstable ventricular arrhythmia, 8 of whom had the unstable arrhythmia as the first arrhythmia after ICD placement. Estimated 2- and 4-year survival in the whole group was 80% and 74%, respectively. Estimated 2- and 4-year probability of any VT and unstable VT was 67% and 77% and 11% and 25%, respectively. There were no differences in age, ejection fraction, sex, underlying heart disease, cycle length, symptoms, baseline electrophysiologic study results, or QRS characteristics of qualifying VT between patients who developed unstable ventricular arrhythmia and patients who did not. Twenty-nine patients (35%) had at least one inappropriate shock, and 11 (13%) underwent further surgery for ICD-related complications. CONCLUSION: Patients who present with hemodynamically stable VT are at risk for subsequent unstable VT. ICD treatment offers potential salvage of patients with stable VT who subsequently develop unstable VT/ventricular fibrillation, although complications and inappropriate shocks are considerable. No predictors could be found for high and low risk for unstable arrhythmias. These findings support ICD treatment for stable VT survivors.

Aged↗

A patient with ORT.

Explore the source record for details and available documents.

Catheter Ablation↗

Implantable cardioverter defibrillator implantation rates in the Olmsted County, Minnesota, population: 1989-1999.

Although the efficacy of implantable cardioverter defibrillators (ICDs) has been demonstrated in randomized clinical trials, implantation and survival rates have not been reported for a defined population. We performed a retrospective cohort analysis of Olmsted County, Minnesota residents (n = 70) who received their first ICD between 1 January 1989 and 31 December 1999. The ICD implantation rate increased from approximately 2.5/100,000 (95% confidence interval [CI], 0.9-4.1) in the first 4 years to 11.5/100,000 (95% CI, 6.7-16.2) in the last 2 years. Twenty-three patients (33%) received an appropriate ICD shock during the observation period. Based on these data, ICDs are estimated to reduce total mortality rates in this population by 0.3%. We conclude that, in patients drawn from a community setting with AHA/ACC class I indications for ICD implantation, implantation of ICDs appears to be highly efficacious in aborting potentially fatal events.

Death, Sudden, Cardiac↗

Impaired detection of ventricular tachyarrhythmias by a rate-smoothing algorithm in dual-chamber implantable defibrillators: intradevice interactions.

INTRODUCTION: Rate smoothing is an algorithm initially designed to prevent rapid changes in pacemaker rates. In this study, we sought to determine the potential of the rate-smoothing mechanism in preventing detection of ventricular tachyarrhythmias. METHODS AND RESULTS: Clinical testing of rate smoothing was performed at the time of defibrillator arrhythmia induction in 16 patients with implantable defibrillators during 65 episodes of ventricular tachyarrhythmias. We also performed simulator-based testing to assess detection of ventricular tachycardia between 170 and 220 beats/min with systematic sequential change of rate-smoothing percent, AV delay, and maximal rate. During clinical testing of 54 ventricular fibrillation/polymorphic ventricular tachyarrhythmia episodes, there were no cases of nondetection and 3 episodes (5%) of minimally delayed detection. Of 10 monomorphic ventricular tachyarrhythmias, 6 had either delayed (2 cases) or absent (4 cases) detection. During simulator testing, complex interrelationships were demonstrated in AV delay, upper rate, and rate-smoothing percent in determining the severity of the effect on detection. Generally, long AV delay, higher upper rate, and smaller (more aggressive) rate smoothing were associated with increased risk of ventricular tachyarrhythmia underdetection. Importantly, use of parameters that impaired detection was always accompanied by a programmer warning message. CONCLUSION: Rate smoothing may result in delay or failure of ventricular tachycardia detection. It is important to consider warning messages when programming rate smoothing and to test for appropriate detection when rate smoothing is used despite warning messages.

Algorithms↗