Advances in interventional neuroradiology 2006.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to David M Pelz.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND AND PURPOSE: Cervical internal carotid artery (ICA) occlusion associated with middle cerebral artery (MCA) embolic occlusion requires prompt revascularization to prevent devastating stroke. With the advent of endovascular techniques for chemical and mechanical thrombolysis, the clinical outcome of patients with major arterial occlusions will improve. Finding the most expedient pathway to the site of end organ occlusion for thrombolysis is important. METHODS: We present two cases of acute stroke secondary to thrombotic occlusion of the cervical ICA associated with MCA embolic occlusion treated with intra-arterial thrombolysis via catheter navigation through the posterior communicating artery to the site of MCA arterial occlusion. No attempt was made to transverse the occluded ICA. RESULTS: Near complete restoration of flow was achieved in one patient and minimal vessel reopening was observed in the other patient. Both patients had good outcomes. CONCLUSION: Intra-arterial thrombolysis via Circle of Willis collaterals such as the posterior communicating artery for the treatment of acute thrombotic occlusion of the cervical internal carotid artery associated with embolic occlusion of the middle cerebral artery is a therapeutic option. This treatment option avoids the potential complications of navigating through an occluded proximal internal carotid artery and may expedite reopening of the MCA.
The question of which is the optimum technique to intubate the trachea in a patient who may have a cervical(C)-spine injury remains unresolved. We compared, using fluoroscopic video, C-spine motion during intubation for Macintosh 3 blade, GlideScope, and Intubating Lighted Stylet, popularly known as the Lightwand or Trachlight. Thirty-six healthy patients were randomized to participate in a crossover trial of either Lightwand or GlideScope to Macintosh laryngoscopy, with in-line stabilization. C-spine motion was examined at the Occiput-C1 junction, C1-2 junction, C2-5 motion segment, and C5-thoracic motion segment during manual ventilation via bag-mask, laryngoscopy, and intubation. Time to intubate was also measured. C-spine motion during bag-mask ventilation was 82% less at the four motion segments studied than during Macintosh laryngoscopy (P < 0.001). C-spine motion using the Lightwand was less than during Macintosh laryngoscopy, averaging 57% less at the four motion segments studied (P < 0.03). There was no significant difference in time to intubate between the Lightwand and the Macintosh blade. C-spine motion was reduced 50% at the C2-5 segment using the GlideScope (P < 0.04) but unchanged at the other segments. Laryngoscopy with GlideScope took 62% longer than with the Macintosh blade (P < 0.01). Thus, the Lightwand (Intubating Lighted Stylet) is associated with reduced C-spine movement during endotracheal intubation compared with the Macintosh laryngoscope.
OBJECT: The authors report on important factors that influenced clinical and angiographically demonstrated outcomes in patients treated using coil embolization. METHODS: This study included 160 consecutive patients who underwent endovascular coil embolization for treatment of intracranial aneurysms. Univariate and multivariate logistic regression analyses were performed to assess factors that influenced the immediate posttreatment angiographic result. Cox regression analysis was used to establish factors related to the occurrence of negative events as well as a curve indicating the time to a negative event. Negative events were defined as aneurysm remnant increase, repeated treatment, rebleeding, or death during periprocedural hospitalization. Seventy-three percent of the patients treated in this study were independent or demonstrated no deficit (Glasgow Outcome Scale [GOS] Score 4 or 5) at a mean follow up of 18.2 months. The annual delayed rebleeding rate was 0.45%. Fifty percent of patients (65 of 131) suffered a negative event within 13 +/- 14 months (standard deviation). Statistically significant factors associated with the occurrence of negative events were rupture status (p = 0.0128) and immediate posttreatment angiographic result (p < 0.001). Overall clinical outcome assessed using the GOS was significantly related to the immediate posttreatment angiographic result (chi2 = 4.788, p = 0.029). The immediate post-treatment angiographic results were significantly influenced by catheter stability (p = 0.0012), aneurysm geometry (that is, simple or complex, p = 0.0053), and aneurysm neck diameter (p = 0.0205). CONCLUSIONS: A good or excellent clinical outcome can be obtained in most patients treated using endovascular coil embolization of intracranial aneurysms. Note, however, that a significant number of patients treated using traditional platinum coils will harbor unstable aneurysm remnants or require repeated treatment.
BACKGROUND AND PURPOSE: One of the limitations of carotid artery angioplasty is the potential for embolic stroke. Our purpose was to assess whether the force of a self-expanding stent alone is usually sufficient to dilate severely stenotic atherosclerotic plaques without the deliberate use of an angioplasty balloon. If so, the procedural stroke risk might be reduced. METHODS: Over a 30-month period, 21 consecutive patients were prospectively identified with severe symptomatic carotid artery stenosis (>70% NASCET [North American Symptomatic Carotid Endarterectomy Trial]) and relative indications for endovascular treatment. All underwent treatment with the aim of deploying a self-expanding stent across the stenosis without the use of angioplasty balloons or distal protection devices. RESULTS: Stent deployment was successful in 20/21 patients. In one patient, the stent could not be deployed without balloon predilatation and a stroke occurred. In the other 20 patients, angiography before and immediately after stent deployment showed a reduction in the mean stenosis from 83% to 49%. A second periprocedural stroke occurred as a result of early stent thrombosis at 4 days in a patient who stopped Acetylsalicylic acid while undergoing bowel preparation for colon surgery. He made a good recovery. Average duration of follow-up imaging was 19 months (range, 1-44 months). During the follow-up period there were four deaths, all unrelated to the carotid disease, and no major strokes. At 5-11 months, the average residual stenosis was 21%, which remained stable in 16 of the 18 patients studied between 12 and 44 months (average, 24 months). At last follow-up, in these 16 the mean peak systolic velocity was 123 cm/s (range, 60-238 cm/s) and the mean internal-to-common carotid ratio was 1.8. The other two patients were long-term failures of the "stent-only" approach. In one patient, a heavily calcified plaque prevented stent expansion and the artery occluded at 18 months with a minor stroke. In the second patient, a recurrent stenosis developed at 16 months with one episode of transient ischemic attack. CONCLUSION: Deployment of a self-expanding stent alone resulted in a favorable and more gradual reduction of severe symptomatic carotid stenosis. Improvements in stent profile and chronic outward force may widen the indications for simple stent placement without the use of balloons or adjunctive protection devices.
BACKGROUND AND PURPOSE: Clinical trials have shown that carotid endarterectomy reduces stroke risk in symptomatic individuals with severe internal carotid artery (ICA) stenosis. As a result of these trials, digital subtraction angiography (DSA) became a standard of reference for ICA stenosis diagnosis. Newer 3D techniques provide a larger number of views than DSA, which may influence the estimated degree of stenosis. We evaluate this possibility by directly comparing stenosis grades from 3D computed rotational angiography (CRA) and DSA. METHODS: As a prospective diagnostic study, we performed CRA and DSA on 26 consecutive symptomatic patients. Only 1 angiographic procedure was performed on normal asymptomatic arteries, yielding 42 arteries for comparison. Four neuroradiologists graded the CRA maximum intensity projections (MIPs) and DSA images, according to the North American Symptomatic Carotid Endarterectomy Trial guidelines. CRA studies included a search for the narrowest view by evaluating 60 MIPs generated at 3 degrees intervals and measurement of actual artery diameters. Artery diameters and stenosis grades were analyzed graphically; statistical significance was determined using a paired t test. RESULTS: The mean difference of 1.2% (CI, -18%, 21%) between CRA and DSA stenosis grades was not statistically significant (P=0.55). Agreement of the optimal CRA viewing angle was limited, with an interobserver variability of 24+/-13 degrees . The interobserver variability of DSA and CRA stenosis grades, 9.1% (CI, 0%, 21%) and 9.4% (CI, 0%, 22%), respectively, was not significantly different (P=0.79). CONCLUSIONS: CRA provides stenosis grades equivalent to DSA, as well as absolute measurements, providing a comparison for newer 3D techniques.
BACKGROUND: Since the validation of carotid endarterectomy (CEA) as an effective means of stroke prevention, there has been renewed interest in its best indications and methods, as well as in how it compares to carotid angioplasty and stenting (CAS). This review examines these topics, as well as the investigation of carotid stenosis and the role of auditing and reporting CEA results. INVESTIGATION: Brain imaging with CT or MRI should be obtained in patients considered for CEA, in order to document infarction and rule out mass lesions. Carotid investigation begins with ultrasound and, if results agree with subsequent, good-quality MRA or CT angiography, treatment can be planned and catheter angiography avoided. An equally acceptable approach is to proceed directly from ultrasound to catheter angiography, which is still the gold-standard in carotid artery assessment. INDICATIONS: Appropriate patients for CEA are those symptomatic with transient ischemic attacks or nondisabling stroke due to 70-99% carotid stenosis; the maximum allowable stroke and death rate being 6%. Uncertain candidates for CEA are those with 50-69% symptomatic stenosis, and those with asymptomatic stenosis > or = 60% but, if selected carefully on the basis of additional risk factors (related to both the carotid plaque and certain patient characteristics), some will benefit from surgery. Asymptomatic patients will only benefit if surgery can be provided with exceptionally low major complication rates (3% or less). Inappropriate patients are those with less than 50% symptomatic or 60% asymptomatic stenosis, and those with unstable medical or neurological conditions. TECHNIQUES: Carotid endarterectomy can be performed with either regional or general anaesthesia and, for the latter, there are a number of monitoring techniques available to assess cerebral perfusion during carotid cross-clamping. While monitoring cannot be considered mandatory and no single monitoring technique has emerged as being clearly superior, EEG is most commonly used. "Eversion" endarterectomy is a variation in surgical technique, and there is some evidence that more widely practiced patch closure may reduce the acute risk of operative stroke and the longer-term risk of recurrent stenosis. CAROTID ANGIOPLASTY AND STENTING: Experience with this endovascular and less invasive procedure grows, and its technology continues to evolve. Some experienced therapists have reported excellent results in case series and a number of randomized trials are now underway comparing CAS to CEA. However, at this time it is premature to incorporate CAS into routine practice replacing CEA. AUDITING: It has been shown that auditing of CEA indications and results with regular feed-back to the operating surgeons can significantly improve the performance of this operation. Carotid endarterectomy auditing is recommended on both local and regional levels.
Angiolipomas are rarely encountered in the spine. We report the case of a 47-year-old man with a thoracic angiolipoma involving the T9 vertebral body. A preoperative spinal angiogram confirmed a highly vascular neoplasm. The lesion was treated with endovascular embolization prior to a T9 corpectomy and resection of the epidural component of the tumor. At time of surgery, minimal blood loss occurred during resection of the vertebral body and the epidural mass. Pathologic examination demonstrated features consistent with spinal angiolipoma. This report emphasizes the clinical, radiographic, and pathologic features of infiltrating spinal angiolipoma and discusses therapeutic management options.