Four methods of measuring tidal volume during high-frequency oscillatory ventilation.

OBJECTIVE: Assess the accuracy of four different methods of measuring tidal volume during simulated high-frequency oscillatory ventilation. DESIGN: In vitro study. SETTING: Research laboratory. SUBJECTS: Three differential pressure pneumotachometers, a modified Pitot tube, an ultrasound flowmeter, and an adult hot wire anemometer. INTERVENTIONS: Each device was placed in series with a Sensormedics 3100B high-frequency ventilator and an 8.0-mm endotracheal tube attached to a 48.9-L plethysmograph. Inspiratory/expiratory ratio was fixed at 1:1 and mean airway pressure at 10 cm H2O. Tidal volumes were calculated at each combination of frequency (f: 3, 4, 6, 8, 10, 12 Hz) and pressure amplitude (DeltaP: 30, 60, 90 cm H2O) by digital integration of the sampled flow signals from each device and compared with those calculated from pressure changes within the plethysmograph. The protocol was repeated after incorporation of frequency-specific calibrations to the flow-measuring algorithm of each device. The hot wire anemometer was further evaluated at Fio2 of 1.0, 37 degrees C, 80% humidity, mean airway pressure of 20 cm H2O, and an inspiratory/expiratory ratio of 1:2. MEASUREMENTS AND MAIN RESULTS: Tidal volumes were 36-305 mL. Bland-Altman analysis demonstrated that each device exhibited systematic bias before frequency-specific adjustment. After frequency-specific adjustment of the flow-measuring algorithm, the two most accurate and precise devices were the Hans Rudolph pneumotachometer, which exhibited a mean error of 0.2% (95% confidence interval, -3.0% to 3.4%), and the hot wire anemometer, which had a mean error of -1.1% (95% confidence interval, -5.5% to 3.3%). The hot wire anemometer remained accurate at Fio2 1.0, 37 degrees C, 80% humidity, mean airway pressure of 20 cm H2O, and an inspiratory/expiratory ratio of 1:2. CONCLUSIONS: Tidal volume can be measured during high-frequency oscillatory ventilation using a variety of techniques. Frequency-specific calibration improves the accuracy and precision of tidal volume measurements. Hot wire anemometry exhibits stable performance characteristics across the range of temperature, humidity, Fio2, and inspiratory/expiratory ratios encountered clinically, has a small deadspace, is unaffected by mean airway pressure, and is therefore suitable for clinical applications.

Adult↗

Tidal volume reduction in patients with acute lung injury when plateau pressures are not high.

Use of a volume- and pressure-limited mechanical ventilation strategy improves clinical outcomes of patients with acute lung injury and acute respiratory distress syndrome (ALI/ARDS). However, the extent to which tidal volumes and inspiratory airway pressures should be reduced to optimize clinical outcomes is a controversial topic. This article addresses the question, "Is there a safe upper limit to inspiratory plateau pressure in patients with ALI/ARDS?" We reviewed data from animal models with and without preexisting lung injury, studies of normal human respiratory system mechanics, and the results of five clinical trials of lung-protective mechanical ventilation strategies. We also present an original analysis of data from the largest of the five clinical trials. The available data from each of these assessments do not support the commonly held view that inspiratory plateau pressures of 30 to 35 cm H2O are safe. We could not identify a safe upper limit for plateau pressures in patients with ALI/ARDS.

Animals↗

Quantifying mechanical heterogeneity in canine acute lung injury: impact of mean airway pressure.

BACKGROUND: The heterogeneous pattern of acute lung injury (ALI) predisposes patients to ventilator-associated lung injury. Currently, there is no simple technique that can reliably quantify lung heterogeneity during the dynamic conditions of mechanical ventilation. Such a technique may be of use in optimizing mechanical ventilatory parameters such as rate, tidal volume, or positive end-expiratory pressure. METHODS: To determine the impact of heterogeneity on respiratory mechanics, the authors measured respiratory impedance (Zrs), expressed as respiratory resistance (Rrs) and elastance (Ers), in 11 anesthetized dogs from 0.078 to 8.9 Hz using broadband pressure and flow excitations under baseline conditions and after ALI produced by infusion of 0.08 ml/kg oleic acid into the right atrium. Data were obtained at mean airway pressures (Pao) of 5, 10, 15, and 20 cm H2O. The Zrs spectra were fit by various models of the respiratory system incorporating different distributions of parallel viscoelastic tissue properties. RESULTS: Under baseline conditions, both Rrs and Ers exhibited dependence on oscillation frequency, reflecting viscoelastic behavior. The Ers demonstrated significant dependence on Pao. After ALI, both the level and frequency dependence of Rrs and Ers increased, as well as the apparent heterogeneity of tissue properties. Both Rrs and Ers as well as heterogeneity decreased with increasing Pao, approaching baseline levels at the highest levels of Pao. CONCLUSIONS: These data demonstrate that Zrs can provide specific information regarding the mechanical heterogeneity of injured lungs at different levels of Pao. Moderate increases in Pao seem to be beneficial in ALI by reducing heterogeneity and recruiting lung units. These noninvasive measurements of lung heterogeneity may ultimately allow for the development of better ventilation protocols that optimize regional lung mechanics in patients with ALI.

Airway Resistance↗