Trabecular bone structure of the calcaneus: comparison of MR imaging at 3.0 and 1.5 T with micro-CT as the standard of reference.

PURPOSE: To investigate in vitro the calcaneal trabecular bone structure in elderly human donors with high spatial resolution magnetic resonance (MR) imaging at 3.0 T and 1.5 T, to quantitatively compare MR measures of bone microarchitecture with those from micro-computed tomography (CT), and to compare the performance of 3.0-T MR imaging with that of 1.5-T MR imaging in differentiating donors with spinal fractures from those without spinal fractures. MATERIALS AND METHODS: The study was performed in line with institutional and legislative requirements; all donors had dedicated their body for educational and research purposes prior to death. Sagittal MR images of 49 human calcaneus cadaveric specimens were obtained (mean age of donors, 79.5 years +/- 11 [standard deviation]; 26 male donors, 23 female donors). After the spatial coregistering of images acquired at 3.0-T and 1.5-T MR imaging, the signal-to-noise-ratios and structural parameters obtained at each magnetic field strength were compared in corresponding sections. Micro-CT was performed on calcaneus cores obtained from corresponding regions in 40 cadaveric specimens. Vertebral deformities of the thoracic and lumbar spine were radiographically classified by using the spinal fracture index. Diagnostic performance of the structural parameters in differentiating donors with vertebral fractures from those without was assessed by using receiver operator characteristic (ROC) analysis, including area under the ROC curve (A(z)). RESULTS: Correlations between structural parameters at 3.0-T MR imaging and those at micro-CT were significantly higher (P < .05) than correlations between structural parameters at 1.5-T MR imaging and those at micro-CT (trabecular thickness, r = 0.76 at 3.0 T vs r = 0.57 at 1.5 T). Trabecular dimensions were amplified at 3.0 T because of increasing susceptibility artifacts. Also, higher ROC values were found for structural parameters at 3.0 T than at 1.5 T, but differences were not significant (trabecular thickness, A(z) = 0.75 at 3.0 T vs A(z) = 0.66 at 1.5 T, P > .05). CONCLUSION: MR imaging at 3.0 T provided a better measure of the trabecular bone structure than did MR imaging at 1.5 T. There was a trend for better differentiation of donors with from those without osteoporotic vertebral fractures at 3.0 T than at 1.5 T.

Aged↗

Cartilage MR imaging at 3.0 versus that at 1.5 T: preliminary results in a porcine model.

PURPOSE: To compare 1.5- and 3.0-T magnetic resonance (MR) images of porcine knee specimens containing artificial cartilage lesions in terms of accuracy of lesion depiction, image quality, and signal-to-noise ratio (SNR). MATERIALS AND METHODS: This Health Insurance Portability and Accountability Act-compliant study had institutional review board approval, and informed consent was obtained from the human volunteers. Two fat-saturated cartilage MR imaging sequences (an intermediate-weighted fast spin-echo [SE] sequence and a spoiled gradient-echo [GRE] sequence) were optimized for imaging at 3.0 T in two human volunteers and then used to image 10 porcine knees in which 29 artificial cartilage lesions had been created. Corresponding sequences were used at 1.5 T for all specimens. Images were assessed by two radiologists in consensus, and diagnostic performance in lesion depiction was determined by using macroscopic findings in specimen slices as a reference standard. SNRs were also calculated. For statistical analysis, the McNemar test of discordant pairs was used with a level of significance of P < .05. RESULTS: The best diagnostic performance for both the intermediate-weighted fast SE and the spoiled GRE sequences was achieved at 3.0 T. With use of corresponding fat-saturated intermediate-weighted fast SE sequences with an identical acquisition time (9 minutes 44 seconds), 26 (90%) of 29 lesions were detected at 3.0 T, while 18 (62%) were detected at 1.5 T. With use of fat-saturated spoiled GRE sequences, 24 (83%) of 29 lesions were detected at 3.0 T (acquisition time, 8 minutes 48 seconds), and 23 (79%) lesions were detected at 1.5 T (acquisition time, 11 minutes 14 seconds). The rate of correct lesion grade assessment was 65% (17 of 26 lesions) at 3.0 T and 61% (11 of 18 lesions) at 1.5 T with the intermediate-weighted fast SE sequences and 83% (20 of 24 lesions) at 3.0 T and 70% (16 of 23 lesions) at 1.5 T with the spoiled GRE sequences. Both subjective evaluation of image quality and SNR values were significantly higher at 3.0 T (P < .05). CONCLUSION: In this animal model, MR imaging at 3.0 T increased the accuracy of cartilage lesion assessment when compared with imaging at 1.5 T. Image quality and SNR were highest at 3.0 T.

Animals↗

Optimization of gadodiamide concentration for MR arthrography at 3 T.

OBJECTIVE: The purpose of our study was to determine the optimal concentration of a gadolinium-based contrast agent (gadodiamide) for direct MR arthrography at 3 T compared with 1.5 T in an in vitro study. CONCLUSION: Optimized concentrations of gadolinium-based contrast agents for MR arthrography are similar at 3 and 1.5 T, although a slightly greater dilution may be useful at 3 T. Signal-to-noise ratio peak levels are significantly reduced by adding an iodinated contrast agent, relatively significantly more at 3 T than at 1.5 T.

Arthrography↗

High-resolution MRI vs multislice spiral CT: which technique depicts the trabecular bone structure best?

The purpose of this study was to compare trabecular bone structure parameters obtained from high-resolution magnetic resonance (HRMR) and multislice computed tomography (MSCT) images with those determined in contact radiographs from corresponding specimen sections. High-resolution MR and MSCT images were obtained in 39 distal radius specimens. For HRMR the in-plane spatial resolution was 0.152x0.153 mm(2) with a slice thickness of 0.9 and 0.3 mm using a 3D T1-weighted spin-echo sequence. For MSCT the resolution was 0.247x0.247 mm(2) with a collimation of 1 mm. Using a diamond saw, 117 0.9- to 1-mm-thick sections were obtained from these specimens and contact radiographs were acquired. In the corresponding sections structure parameters analogous to bone histomorphometry were determined. Significant correlations between MR- and CT-derived structure parameters and those derived from the contact radiographs were found (p<0.01); r values of up to 0.75 were obtained for HRMR imaging and up to 0.70 for MSCT. On the average, structure parameters showed higher correlations for the MR- than for the CT-derived data. For the MR data the threshold algorithm used for binarizing the images substantially affected these correlations. In conclusion, trabecular bone structure parameters assessed in distal radius HRMR and MSCT images are significantly correlated with those determined in corresponding specimen sections (p<0.01). High-resolution MR-derived structure parameters, however, performed better in the prediction of trabecular bone structure.

Aged↗

Dissociating perceptual and conceptual implicit memory in multiple sclerosis patients.

Previous studies indicate that Multiple Sclerosis (MS) patients exhibit deficits in tests of explicit memory such as free recall, but show normal priming on implicit tests of memory such as word stem completion. However, the memory performance of patients with different MS disease subtypes has not been fully examined. In the current study, memory was assessed in Primary Progressive (PPMS), Relapsing Remitting (RRMS), and Secondary Progressive (SPMS) MS subgroups. Explicit memory as well as perceptual and conceptual implicit memory were examined using free recall, word fragment completion, and exemplar generation tests, respectively. All three groups of MS patients exhibited free recall deficits and normal priming on the exemplar generation test. However, the PPMS group exhibited a deficit in word fragment completion priming, whereas the RRMS and SPMS groups exhibited normal levels of priming on this task. Lesion load was assessed using magnetic resonance imaging and was negatively correlated with explicit memory performance, but it did not account for the observed deficits in perceptual implicit memory. The results indicate that PPMS patients exhibit a pattern of memory impairment that is distinct from that of the RRMS and SPMS groups. Moreover, the results indicate that perceptual implicit memory can be neurologically dissociated from conceptual implicit memory.

Adult↗

Local differences in the trabecular bone structure of the proximal femur depicted with high-spatial-resolution MR imaging and multisection CT.

RATIONALE AND OBJECTIVES: The authors performed this study to investigate structural variations in the trabecular bone of the proximal femur at high-resolution magnetic resonance (MR) imaging and high-resolution multisection computed tomography (CT). MATERIALS AND METHODS: Bone mineral density (BMD) was measured in 36 proximal human femur specimens by using dual x-ray absorptiometry. High-resolution MR imaging was performed at 1.5 T with an in-plane spatial resolution of 0.195 x 0.195 mm and a section thickness of 0.3 and 0.9 mm. Multisection CT was performed with an ultra-high-resolution protocol; images were obtained with an in-plane spatial resolution of 0.25 mm and a section thickness of 1 mm. In a subset of these specimens, micro CT was performed with an isotropic spatial resolution of 30 microm. Identical regions of interest (ROIs) were used to analyze images obtained with MR imaging, multisection CT, and micro CT. Trabecular bone structural parameters were obtained, and the parameters from the individual imaging modalities and BMD were correlated. RESULTS: Significant differences concerning the trabecular microarchitecture between the individual ROIs were demonstrated with multisection CT and MR imaging. A number of the correlations between structural parameters derived with multisection CT, MR imaging, micro CT, and BMD measurements were significant. For MR imaging, threshold technique and section thickness had an effect on structural parameters. CONCLUSION: Structural parameters obtained in the proximal femur with multisection CT and high-resolution MR imaging show regional differences. These techniques may be useful for depicting the trabecular architecture in the diagnosis of osteoporosis.

Adult↗

Bone structure of the distal radius and the calcaneus vs BMD of the spine and proximal femur in the prediction of osteoporotic spine fractures.

The aim of this study was to compare structure measures obtained from high-resolution MR images of the calcaneus and the distal radius with bone mineral density (BMD) of the spine and hip in the prediction of osteoporotic spine fracture status. High-resolution MR images of the calcaneus and radius were obtained in 24 post-menopausal women with spine fractures and 22 age-matched controls. Imaging was performed at 1.5 T using a T1-weighted spin-echo sequence (slice thickness 1 mm, in-plane spatial resolution 195 x 195 microm(2)). Structure analysis was performed using parameters analogous to standard histomorphometry. Bone mineral density of the spine was obtained using quantitative CT and of the hip with dual-energy X-ray absorptiometry. Significant differences between both patient groups were obtained with BMD and all structure parameters ( p<0.05). Using receiver operating characteristic analysis to determine the diagnostic performance in differentiating both groups, the best results were found for BMD of the spine, one of the radial structure measures and a combination of the calcaneal structure measures. In this study BMD of the spine and structure measures of the distal radius were best suited to predict the osteoporotic fracture status of the spine. A combination of BMD and structure measures did not yield any additional information on fracture status.

Absorptiometry, Photon↗