PubMed Health⌕ Search

Biomedical subjects

David Norwood

Publications and source records attributed to David Norwood.

9 recordsLinked to original sources

Multiplexed detection of anthrax-related toxin genes.

Simultaneous analysis of three targets in three colors on any real-time polymerase chain reaction (PCR) instrument would increase the flexibility of real-time PCR. For the detection of Bacillus strains that can cause inhalation anthrax-related illness, this ability would be valuable because two plasmids confer virulence, and internal positive controls are needed to monitor the testing in cases lacking target-specific signals. Using a real-time PCR platform called MultiCode-RTx, multiple assays were developed that specifically monitor the presence of Bacillus anthracis-specific virulence plasmid-associated genes. In particular for use on LightCycler-1, two triplex RTx systems demonstrated high sensitivity with limits of detection nearing single-copy levels for both plasmids. Specificity was established using a combination of Ct values and correct amplicon melting temperatures. All reactions were further verified by detection of an internal positive control. For these two triplex RTx assays, the analytical detection limit was one to nine plasmid copy equivalents, 100% analytical specificity with a 95% confidence interval (CI) of 9%, and 100% analytical sensitivity with a CI of 2%. Although further testing using clinical or environmental samples will be required to assess diagnostic sensitivity and specificity, the RTx platform achieves similar results to those of probe-based real-time systems.

Antigens, Bacterial↗

Development and evaluation of an efficient 3'-noncoding region based SARS coronavirus (SARS-CoV) RT-PCR assay for detection of SARS-CoV infections.

The severe acute respiratory syndrome (SARS) epidemic originating from China in 2002 was caused by a previously uncharacterized coronavirus that could be identified by specific RT-PCR amplification. Efforts to control future SARS outbreaks depend on the accurate and early identification of SARS-CoV infected patients. A real-time fluorogenic RT-PCR assay based on the 3'-noncoding region (3'-NCR) of SARS-CoV genome was developed as a quantitative SARS diagnostic tool. The ideal amplification efficiency of a sensitive SARS-CoV RT-PCR assay should yield an E value (PCR product concentration increase per amplification cycle) equal to 2.0. It was demonstrated that the 3'-NCR SARS-CoV based RT-PCR reactions could be formulated to reach excellent E values of 1.81, or 91% amplification efficacy. The SARS-CoV cDNA preparations derived from viral RNA extract and the cloned recombinant plasmid both exhibit the identical amplification characteristics, i.e. amplification efficacy using the same PCR formulation developed in this study. The viral genomic copy (or genomic equivalences, GE) per infectious unit (GE/pfu) of SARS-CoV used in this study was also established to be approximate 1200-1600:1. The assay's detection sensitivity could reach 0.005 pfu or 6-8 GE per assay. It was preliminarily demonstrated that the assay could efficiently detect SARS-CoV from clinical specimens of SARS probable and suspected patients identified in Taiwan. The 3'-NCR based SARS-CoV assay demonstrated 100% diagnostic specificity testing samples of patients with acute respiratory disease from a non-SARS epidemic region.

3' Untranslated Regions↗

Monkeypox virus detection in rodents using real-time 3'-minor groove binder TaqMan assays on the Roche LightCycler.

During the summer of 2003, an outbreak of human monkeypox occurred in the Midwest region of the United States. In all, 52 rodents suspected of being infected with monkeypox virus were collected from an exotic pet dealer and from private homes. The rodents were euthanized and submitted for testing to the United States Army Medical Research Institute of Infectious Diseases by the Galesburg Animal Disease Laboratory, Illinois Department of Agriculture. The rodent tissue samples were appropriately processed and then tested by using an integrated approach involving real-time polymerase chain reaction (PCR) assays, an antigen-detection immunoassay, and virus culture. We designed and extensively tested two specific real-time PCR assays for rapidly detecting monkeypox virus DNA using the Vaccinia virus F3L and N3R genes as targets. The assays were validated against panels of orthopox viral and miscellaneous bacterial DNAs. A pan-orthopox electrochemiluminescence (ECL) assay was used to further confirm the presence of Orthopoxvirus infection of the rodents. Seven of 12 (58%) animals (seven of 52 (15%) of all animals) tested positive in both monkeypox-specific PCR assays and two additional pan-orthopox PCR assays (in at least one tissue). The ECL results showed varying degrees of agreement with PCR. One hamster and three gerbils were positive by both PCR and ECL for all tissues tested. In addition, we attempted to verify the presence of monkeypox virus by culture on multiple cell lines, by immunohistology, and by electron microscopy, with negative results. Sequencing the PCR products from the samples indicated 100% identity with monkeypox virus strain Zaire-96-I-16 (a human isolate from the Congo). These real-time PCR and ECL assays represent a significant addition to the battery of tests for the detection of various orthopoxviruses. In light of the recent monkeypox virus transmissions, early detection of the virus is crucial for both natural outbreaks and potential acts of bioterrorism.

Animals↗

Detection of the Bacillus anthracis gyrA gene by using a minor groove binder probe.

Identification of chromosomal markers for rapid detection of Bacillus anthracis is difficult because significant chromosomal homology exists among B. anthracis, Bacillus cereus, and Bacillus thuringiensis. We evaluated the bacterial gyrA gene as a potential chromosomal marker for B. anthracis. A real-time PCR assay was developed for the detection of B. anthracis. After analysis of the unique nucleotide sequence of the B. anthracis gyrA gene, a fluorescent 3' minor groove binding probe was tested with 171 organisms from 29 genera of bacteria, including 102 Bacillus strains. The assay was found to be specific for all 43 strains of B. anthracis tested. In addition, a test panel of 105 samples was analyzed to evaluate the potential diagnostic capability of the assay. The assay showed 100% specificity, demonstrating the usefulness of the gyrA gene as a specific chromosomal marker for B. anthracis.

Bacillus anthracis↗

Real-time PCR assay for a unique chromosomal sequence of Bacillus anthracis.

Real-time PCR has become an important method for the rapid identification of Bacillus anthracis since the 2001 anthrax mailings. Most real-time PCR assays for B. anthracis have been developed to detect virulence genes located on the pXO1 and pXO2 plasmids. In contrast, only two published chromosomal targets exist, the rpoB gene and the gyrA gene. In the present study, subtraction-hybridization with a plasmid-cured B. anthracis tester strain and a Bacillus cereus driver was used to find a unique chromosomal sequence. By targeting this region, a real-time assay was developed with the Ruggedized Advanced Pathogen Identification Device. Further testing has revealed that the assay has 100% sensitivity and 100% specificity, with a limit of detection of 50 fg of DNA. The results of a search for sequences with homology with the BLAST program demonstrated significant alignment to the recently published B. anthracis Ames strain, while an inquiry for protein sequence similarities indicated homology with an abhydrolase from B. anthracis strain A2012. The importance of this chromosomal assay will be to verify the presence of B. anthracis independently of plasmid occurrence.

Bacillus anthracis↗

Smallpox and pan-orthopox virus detection by real-time 3'-minor groove binder TaqMan assays on the roche LightCycler and the Cepheid smart Cycler platforms.

We designed, optimized, and extensively tested several sensitive and specific real-time PCR assays for rapid detection of both smallpox and pan-orthopox virus DNAs. The assays are based on TaqMan 3'-minor groove binder chemistry and were performed on both the rapid-cycling Roche LightCycler and the Cepheid Smart Cycler platforms. The hemagglutinin (HA) J7R, B9R, and B10R genes were used as targets for the variola virus-specific assays, and the HA and DNA polymerase-E9L genes were used as targets for the pan-orthopox virus assays. The five orthopox virus assays were tested against a panel of orthopox virus DNAs (both genomic and cloned) at the U.S. Army Medical Research Institute of Infectious Diseases (USAMRIID). The results indicated that each assay was capable of detecting both the appropriate cloned gene and genomic DNA. The assays showed no cross-reactivity to the 78 DNAs in the USAMRIID bacterial cross-reactivity panel. The limit of detection (LOD) of each assay was determined to be between 12 and 25 copies of target DNA. The assays were also run against a blind panel of DNAs at the Centers for Disease Control and Prevention (CDC) on both the LightCycler and the Smart Cycler. The panel consisted of eight different variola virus isolates, five non-variola virus orthopox virus isolates, two varicella-zoster virus isolates, and one herpes simplex virus isolate. Each sample was tested in triplicate at 2.5 ng, 25 pg, 250 fg, and 2.5 fg, which represent 1.24 x 10(7), 1.24 x 10(5), 1.24 x 10(3), and 1.24 x 10(1) genome equivalents, respectively. The results indicated that each of the five assays was 100% specific (no false positives) when tested against both the USAMRIID panels and the CDC blind panel. With the CDC blind panel, the LightCycler was capable of detecting 96.2% of the orthopox virus DNAs and 93.8% of the variola virus DNAs. The Smart Cycler was capable of detecting 92.3% of the orthopox virus DNAs and between 75 and 93.8% of the variola virus DNAs. However, all five assays had nearly 100% sensitivity on both machines with samples above the LOD (>12 gene copies). These real-time PCR assays represent a battery of tests to screen for and confirm the presence of variola virus DNA. The early detection of a smallpox outbreak is crucial whether the incident is an act of bioterrorism or an accidental occurrence.

Base Sequence↗

Use of denaturing high-performance liquid chromatography to identify Bacillus anthracis by analysis of the 16S-23S rRNA interspacer region and gyrA gene.

Denaturing high-performance liquid chromatography (DHPLC) was evaluated as a method for identifying Bacillus anthracis by analyzing two chromosomal targets, the 16S-23S intergenic spacer region (ISR) and the gyrA gene. The 16S-23S ISR was analyzed by this method with 42 strains of B. anthracis, 36 strains of Bacillus cereus, and 12 strains of Bacillus thuringiensis; the gyrA gene was analyzed by this method with 33 strains of B. anthracis, 27 strains of B. cereus, and 9 strains of B. thuringiensis. Two blind panels of 45 samples each were analyzed to evaluate the potential diagnostic capability of this method. Our results show that DHPLC is an efficient method for the identification of B. anthracis.

Bacillus anthracis↗

Detection and identification of ciprofloxacin-resistant Yersinia pestis by denaturing high-performance liquid chromatography.

Denaturing high-performance liquid chromatography (DHPLC) has been used extensively to detect genetic variation. We used this method to detect and identify Yersinia pestis KIM5 ciprofloxacin-resistant isolates by analyzing the quinolone resistance-determining region (QRDR) of the gyrase A gene. Sequencing of the Y. pestis KIM5 strain gyrA QRDR from 55 ciprofloxacin-resistant isolates revealed five mutation types. We analyzed the gyrA QRDR by DHPLC to assess its ability to detect point mutations and to determine whether DHPLC peak profile analysis could be used as a molecular fingerprint. In addition to the five mutation types found in our ciprofloxacin-resistant isolates, several mutations in the QRDR were generated by site-directed mutagenesis and analyzed to further evaluate this method for the ability to detect QRDR mutations. Furthermore, a blind panel of 42 samples was analyzed by screening for two mutant types to evaluate the potential diagnostic value of this method. Our results showed that DHPLC is an efficient method for detecting mutations in genes that confer antibiotic resistance.

Anti-Infective Agents↗

Denaturing HPLC for identifying bacteria.

Denaturing HPLC (DHPLC) is used in a wide variety of genetic applications. Here we introduce a new application for this technique, the identification of bacteria. We combined the capability of DHPLC to detect sequence variation with the principles of rRNA genotyping analysis to develop a high-throughput method of identifying microorganisms. Thirty-nine bacterial species from a broad spectrum of genera were tested to determine if DHPLC could be usedfor identification. Most (36 of 39) species of bacteria had a unique peak profile that could be used as a molecular fingerprint. Furthermore, a blind panel of 65 different bacterial isolates was analyzed to demonstrate the diagnostic capability of this method to specifically identify Yersinia pestis and Bacillus anthracis. All the Y. pestis samples (10 of 10) and the majority of B. anthracis samples (12 of 14) were correctly identified. The procedure had an overall specificity of 100%, overall sensitivity of 91.7%, and a predictive value of 96.9%. The data suggest that DHPLC of products spanning regions of genetic variability will be a useful application for bacterial identification.

Bacteria↗