Optimized clinical T2 relaxometry with a standard CPMG sequence.

PURPOSE: To optimize the accuracy and precision of T2 measurements using the standard Carr-Purcell-Meiboom-Gill (CPMG) sequence. T2 values obtained with this technique are normally sensitive to imperfect refocusing due to the formation of unwanted stimulated echoes. MATERIALS AND METHODS: Modifications are made to the refocusing slice selection width and the interleaving scheme. A widened refocusing slice improves the uniformity of the refocusing flip angle across the slice. A slow spin echo acquisition provided "gold standard" T2 values. Repeated T2 measurements in phantom and human studies are used to compare the accuracy and precision of the optimized and non-optimized CPMG implementations. RESULTS: The required slice thickness ratio between refocusing and excitation slice widths is found to be 3:1 for typical optimized radiofrequency pulses. T2 values obtained using this optimized implementation more closely correspond to "gold standard" values. Repeated T2 measurements indicate significantly improved correspondence between data and model. A reduction in the fitting error of approximately 70% is demonstrated for phantoms. CONCLUSION: We demonstrate that a relatively simple change to the CPMG relaxometry sequence parameters from the default setup yields significant improvements in the accuracy and precision of T2 measurements.

Adult↗

TurboFLASH FAIR imaging with optimized inversion and imaging profiles.

Optimal implementation of pulsed arterial spin labeling (PASL) methods such as flow-sensitive alternating inversion recovery (FAIR), require the minimization of interactions between the inversion and imaging slabs. For FAIR, the inversion:imaging slice thickness ratio (STR) is usually at least 3:1 in order to fully contain the extent of the imaging slice. The resulting gap exacerbates the transit time. So far, efforts to minimize the STR have concentrated on the inversion profile. However, the imaging profile remains a limiting factor especially for rapid sequences such as turbo fast low-angle shot (TurboFLASH) which uses short pulses. This study reports the implementation of a TurboFLASH sequence with optimized inversion and imaging profiles. Slice-selection is achieved with a preparation module incorporating a pair of identical adiabatic frequency offset corrected inversion (FOCI) pulses. The optimum radiofrequency (RF) and gradient scheme for this pulse combination is described, and the relaxation characteristics of the slice-selection scheme are investigated. Phantom experiments demonstrate a reduction in the STR to approximately 1.13:1. Implementation in an animal model is described, and the benefit of the improved profile in probing the sensitivity of the flow signal to tagging geometry is demonstrated. Sensitivity to transit time effects can be minimized with this sequence, and ASL methodologies can be better explored as a result of the improved conformance with the ideal of square slice profiles.

Animals↗

Pulsed arterial spin labeling using TurboFLASH with suppression of intravascular signal.

Accurate quantification of perfusion with the ADC techniques requires the suppression of the majority of the intravascular signal. This is normally achieved with the use of diffusion gradients. The TurboFLASH sequence with its ultrashort repetition times is not readily amenable to this scheme. This report demonstrates the implementation of a modified TurboFLASH sequence for FAIR imaging. Intravascular suppression is achieved with a modified preparation period that includes a driven equilibrium Fourier transform (DEFT) combination of 90 degrees-180 degrees-90 degrees hard RF pulses subsequent to the inversion delay. These pulses rotate the perfusion-prepared magnetization into the transverse plane where it can experience the suitably placed diffusion gradients before being returned to the longitudinal direction by the second 90 degrees pulse. A value of b = 20-30 s/mm(2) was thereby found to suppress the majority of the intravascular signal. For single-slice perfusion imaging, quantification is only slightly modified. The technique can be readily extended to multislice acquisition if the evolving flow signal after the DEFT preparation is considered. An advantage of the modified preparation scheme is evident in the multislice FAIR images by the preservation of the sign of the magnetization difference.

Animals↗