PubMed Health⌕ Search

Biomedical subjects

David P Naidich

Publications and source records attributed to David P Naidich.

10 recordsLinked to original sources

Pulmonary nodules on multi-detector row CT scans: performance comparison of radiologists and computer-aided detection.

PURPOSE: To compare the performance of radiologists and of a computer-aided detection (CAD) algorithm for pulmonary nodule detection on thin-section thoracic computed tomographic (CT) scans. MATERIALS AND METHODS: The study was approved by the institutional review board. The requirement of informed consent was waived. Twenty outpatients (age range, 15-91 years; mean, 64 years) were examined with chest CT (multi-detector row scanner, four detector rows, 1.25-mm section thickness, and 0.6-mm interval) for pulmonary nodules. Three radiologists independently analyzed CT scans, recorded the locus of each nodule candidate, and assigned each a confidence score. A CAD algorithm with parameters chosen by using cross validation was applied to the 20 scans. The reference standard was established by two experienced thoracic radiologists in consensus, with blind review of all nodule candidates and free search for additional nodules at a dedicated workstation for three-dimensional image analysis. True-positive (TP) and false-positive (FP) results and confidence levels were used to generate free-response receiver operating characteristic (ROC) plots. Double-reading performance was determined on the basis of TP detections by either reader. RESULTS: The 20 scans showed 195 noncalcified nodules with a diameter of 3 mm or more (reference reading). Area under the alternative free-response ROC curve was 0.54, 0.48, 0.55, and 0.36 for CAD and readers 1-3, respectively. Differences between reader 3 and CAD and between readers 2 and 3 were significant (P < .05); those between CAD and readers 1 and 2 were not significant. Mean sensitivity for individual readings was 50% (range, 41%-60%); double reading resulted in increase to 63% (range, 56%-67%). With CAD used at a threshold allowing only three FP detections per CT scan, mean sensitivity was increased to 76% (range, 73%-78%). CAD complemented individual readers by detecting additional nodules more effectively than did a second reader; CAD-reader weighted kappa values were significantly lower than reader-reader weighted kappa values (Wilcoxon rank sum test, P < .05). CONCLUSION: With CAD used at a level allowing only three FP detections per CT scan, sensitivity was substantially higher than with conventional double reading.

Adolescent↗

CT screening for lung cancer: suspiciousness of nodules according to size on baseline scans.

PURPOSE: To assess the frequency with which a particular, possibly optimal work-up of noncalcified nodules less than 5.0 mm in diameter identified on initial computed tomographic (CT) images at baseline screening leads to a diagnosis of malignancy prior to first annual repeat screening, compared with a possibly optimal work-up of larger nodules. MATERIALS AND METHODS: Two series of baseline CT screenings in high-risk people were retrospectively reviewed. The first series (n = 1,000) was performed in 1993-1998; the second (n = 1,897), in 1999-2002. In each series, cases in which the largest noncalcified nodule detected was less than 5.0 mm in diameter and those in which it was 5.0-9 mm were reviewed to determine whether diagnostic work-up prior to first annual repeat screening showed or would have shown nodule growth and led or would have led to a diagnosis based on biopsy or surgical specimens. RESULTS: The frequency with which malignancy was or could have been diagnosed when the largest noncalcified nodule was less than 5.0 mm in diameter was 0 of 378, whereas when the largest noncalcified nodule was 5.0-9 mm in diameter, the frequency was 13 or 14 of 238. If persons with only nodules smaller than 5.0 mm had merely been referred for first annual repeat screening without immediate further work-up, the referrals for such work-up would have been reduced by 54% (from 817 [28%] to 385 [13%] of 2,897). CONCLUSION: In modern CT screening for lung cancer at baseline, detected noncalcified nodules smaller than 5.0 mm in diameter do not justify immediate work-up but only annual repeat screening to determine whether interim growth has occurred.

Adult↗

Imaging of unusual diffuse lung diseases.

PURPOSE OF REVIEW: Computed tomography scans are commonly used in imaging lung diseases. As more information accumulates, patterns of rare or new diseases on CT scans are being increasingly reported. Several pulmonary diseases have distinguishing features, which are better delineated on high resolution CT scans than plain chest radiographs. The radiographic features of unusual diffuse lung diseases published in the past two years are described. RECENT FINDINGS: Severe acute respiratory syndrome generally manifests as focal or diffuse bilateral areas of consolidation on chest radiography and reticulation with ground-glass attenuation commonly seen on CT scans. A normal HRCT rules out the diagnosis of Pneumocystis carinii pneumonia while a normal chest radiograph does not. Immunocompromised patients without AIDS, who have CMV pneumonia, generally demonstrate a combination of ground-glass attenuation, air-space consolidation, and small nodules on HRCT. Nodules less than 10 mm in size in immunocompromised patients are highly suggestive of viral infections. Bronchial wall thickening on HRCT associated with cavitating nodules is suggestive of Wegner granulomatosis in the appropriate clinical setting. Small cysts may be seen in a minority of patients with subacute hypersensitivity pneumonitis and centrilobular emphysema in chronic farmer's lung. Reversed halo sign has a high specificity for cryptogenic organizing pneumonia. The triad of ground-glass opacities, ill-defined centrilobular nodules and cysts and focal areas of air trapping is highly suggestive of subacute hypersensitivity pneumonitis. SUMMARY: Familiarizing with radiographic and CT scan patterns may help the clinician to exclude certain diagnoses and narrow the differential diagnosis for others.

Cytomegalovirus Infections↗

Wavelet compression of low-dose chest CT data: effect on lung nodule detection.

PURPOSE: To assess the effect of using a lossy Joint Photographic Experts Group standard for wavelet image compression, JPEG2000, on pulmonary nodule detection at low-dose computed tomography (CT). MATERIALS AND METHODS: One hundred sets of lung CT data ("cases") were compressed to 30:1, 20:1, and 10:1 levels by using a wavelet-based JPEG2000 method, resulting in 400 test cases. Each case consisted of nine 1.25-mm sections that had been obtained with 20-40 mAs. Four thoracic radiologists independently interpreted the test case images. Performance was measured by using area under the receiver operating characteristic (ROC) curve (Az) and conventional sensitivity and specificity analyses. RESULTS: There were 51 cases with and 49 without lung nodules. Az values were 0.984, 0.988, 0.972, 0.921, respectively, for original and 10:1, 20:1, and 30:1 compressed images. Az values decreased significantly at 30:1 (P =.014) but not at 10:1 compression, with a trend toward significant decrease at 20:1 (P =.051). Specificity values were unaffected by compression (>98.0% at all compression levels). Sensitivity values were 86.3% (176 of 204 test cases with nodules), 77.9% (159 of 204 cases), 76.5% (156 of 204 cases), and 70.1% (143 of 204 cases), respectively, for original and 10:1, 20:1, and 30:1 compressed images. Results of logistic regression model analysis confirmed the significant effects of compression rate and nodule attenuation, size, and location on sensitivity (P <.05). CONCLUSION: While no reduction in nodule detection at 10:1 compression levels was demonstrated by using ROC analysis, a significant decrease in sensitivity was identified. Further investigation is needed before widespread use of image compression technology in low-dose chest CT can be recommended.

Humans↗

Lung nodule detection and characterization with multislice CT.

The ability to identify and characterize pulmonary nodules has been dramatically increased by the introduction of multislice CT (MSCT) technology. Using high-resolution sections, MSCT allows considerable improvement in assessing nodule morphology, enhancement patterns, and growth. MSCT also has facilitated the development and potential of clinical application of computer-assisted diagnosis.

Algorithms↗

Small pulmonary nodules: volume measurement at chest CT--phantom study.

Three-dimensional methods for quantifying pulmonary nodule volume at computed tomography (CT) and the effect of imaging variables were studied by using a realistic phantom. Two fixed-threshold methods, a partial-volume method (PVM) and a variable method, were used to calculate volumes of 40 plastic nodules (largest dimension, <5 mm: 20 nodules with solid attenuation and 20 with ground-glass attenuation) of known volume. Tube current times (20 and 120 mAs), reconstruction algorithms (high and low frequency), and nodule characteristics were studied. Higher precision was associated with use of a PVM with predetermined pure nodule attenuation, high-frequency algorithm, and diagnostic CT technique (120 mAs). A PVM is promising for volume quantification and follow-up of nodules.

Algorithms↗

CT of airways disease and bronchiectasis.

High-resolution CT is accepted as an accurate noninvasive means of diagnosing bronchiectasis. A wide spectrum of abnormalities may be identified at HRCT in patients with airway disease, including various distinctive patterns of bronchiectasis in specific clinical settings, such as ABPA, MAC infection, AIDS, and CF. Characteristic CT findings occasionally suggest a specific diagnosis that may not have been under clinical consideration. HRCT also provides significant clinical use in assessing the degree and extent of airway disease, and allows noninvasive monitoring of disease progression, regression, or response to therapy.

AIDS-Related Opportunistic Infections↗

CT screening for lung cancer Assessing a regimen's diagnostic performance.

PURPOSE: The purpose of this study was to characterize the diagnostic performance of a regimen of CT screening for lung cancer. METHODS: Using a common protocol/regimen of screening, 2968 asymptomatic persons at high risk for lung cancer were enrolled in two studies [Early Lung Cancer Action Projects (ELCAP) I and II] for baseline and annual repeat screening. A total of 4538 annual repeat screenings were performed. The regimen's diagnostic performance was characterized in terms of frequency of positive result of the initial CT as well as of screen-diagnosis and Stage I screen-diagnosis among all diagnoses (interim-diagnoses included), all separately for baseline and annual repeat screenings. RESULTS: The proportions with positive result of the initial CT were 12% and 6% in the baseline and repeat screenings, respectively. The proportions of screen-diagnoses among all diagnoses (interim-diagnoses included) were 97% and 99% in the baseline and repeat cycles, respectively. The corresponding proportions of pre-surgical Stage I screen-diagnoses were 95% and 93%. CONCLUSION: The performance of the ELCAP regimen is quite satisfactory in avoiding over many positive results of the initial CT, and it produces highly promising diagnostic results as for the attainment of cure by early intervention.

Aged↗

Interferon-induced sarcoidosis.

Interferons have been used as therapy of both malignant and nonmalignant diseases and commonly in the treatment of hepatitis C virus infection. Although the most commonly encountered side effects of interferon therapy include nonspecific constitutional symptoms, pulmonary involvement is rare. Here, we provide two documented cases of sarcoidosis appearing in patients receiving interferon therapy for hepatitis C infection, because there have only been a few reports of this association. Physicians should be aware of this uncommon yet clinically important complication, because imaging these patients may obviate more invasive procedures.

Antiviral Agents↗