2 recordsLinked to original sources

Capnogram shape in obstructive lung disease.

Small, preliminary studies have suggested that capnograms of obstructive lung disease (OD) exhibit a characteristic shape and that this shape may be correlated to changes in forced expiratory volume in 1 s (FEV(1)). We evaluated the association between capnograms and spirometry from subjects with OD with normal and restrictive lung disease (RD) subjects. The study was conducted in a prospective, nonrandomized manner using a convenience sample of 262 subjects presenting to a pulmonary function laboratory. Capnograms were recorded before pulmonary function testing. Subjects with OD had capnograms that were significantly different from normal and RD subjects. These differences were progressive, increasing with disease severity. The average take-off angle of the ascending phase for severe OD was 7.2 degrees less (95% confidence interval [CI]: 4.0, 10.4) than for normals. The average alveolar plateau elevation angle was 0.8 degrees more (95% CI: 0.14, 1.4) for moderate OD than for normals, whereas the average elevation angle was 3.6 degrees more (95% CI: 2.9, 4.3) for severe OD than for normals. Differences between OD capnograms and normal and RD capnograms, correlating to changes in FEV(1), were sufficiently large enough to suggest that the capnogram could be used to discriminate between OD and normal.

Adult↗

Specificity and sensitivity of automated external defibrillator rhythm analysis in infants and children.

STUDY OBJECTIVES: The rhythm detection algorithms of automated external defibrillators have been derived from adult rhythms, and their ability to discriminate between shockable and nonshockable rhythms in children is largely unknown. This study evaluates the performance of 1 automated external defibrillator algorithm in infants and children and evaluates algorithm performance with anterior-posterior versus sternal-apex lead placement. METHODS: We enrolled pediatric patients in a critical care unit, an electrophysiology laboratory, and a cardiac operating room. A monitor-defibrillator recorded ECGs by means of standard defibrillation-monitor pads. Selected 15-second rhythm samples were played into a LIFEPAK 500 automated external defibrillator, and the automated external defibrillator "shock/no shock" decision was documented. To determine sensitivity and specificity, the automated external defibrillator decision was compared with the "shockable" versus "nonshockable" rhythm classification provided by 3 expert clinicians who were blinded to the automated external defibrillator decision. RESULTS: We recorded 1,561 rhythm samples from 203 pediatric patients (median age 11 months; range, day of birth to 7 years). The automated external defibrillator recommended a shock for 72 of 73 rhythm samples classified as coarse ventricular fibrillation by expert review (sensitivity 99%; 95% confidence interval [CI] 93% to 100%); and correctly reached a "no shock advised" decision for 1,465 of 1,472 rhythm samples classified as nonshockable by experts (specificity 99.5%). Specificity was 99.1% (95% CI 97.8% to 99.8%) with the sternal-apex lead and 99.4% (95% CI 98.1% to 99.9%) with the anterior-posterior lead. CONCLUSION: This automated external defibrillator algorithm has high specificity and sensitivity when used in infants and children with either sternal-apex or anterior-posterior lead placement.

Age Factors↗