Correcting aponeurotic ptosis.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to David R Jordan.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: Conjunctival lymphoproliferative lesions have not been selected for independent analysis with newer immunohistochemical and molecular genetic techniques to highlight their unique profile. METHODS: Retrospective case series examined biopsies from 16 consecutive patients with conjunctival lymphoproliferative lesions. The histopathologic, immunohistochemical, and molecular genetic features were characterized, as well as the frequency of tumour type, prognostic implications, clinical features, and treatments offered. RESULTS: The diagnosis was lymphoma in 12 cases, atypical lymphoid hyperplasia (ALH) in 1 case, and reactive lymphoid hyperplasia (RLH) in 3 cases. The primary lymphomas consisted of 4 mucosa-associated lymphoid tissue lymphomas (MALTL), 1 follicular lymphoma (FL), 2 diffuse large B-cell lymphomas (DLBCLs), 1 lymphoplasmacytic lymphoma, and 1 T-cell lymphoma. Primary lymphomas were treated with radiation (n = 7), surgery (n = 1), and topical chemotherapy (n = 1). Complete remission was achieved in 8 of 9 primary lymphomas. Two cases of recurrence to the other conjunctiva were treated with radiation and both remained disease free. Secondary lymphomas included 2 DLBCL and 1 MALTL. Complete remission was seen in 2 patients after radiation plus chemotherapy, while the patient treated with chemotherapy alone was lost to follow-up. The 1 case of ALH presented bilaterally and achieved complete remission after topical chemotherapy treatments. The 3 RLH cases were surgically managed and 2 of the 3 recurred and were subsequently excised. Eleven lymphomas were of B-cell lineage by immunophenotyping. Molecular genetic studies of immunoglobulin heavy chain (IgH) gene rearrangement by polymerase chain reaction (PCR) showed clonal bands in 6 of 12 lymphomas, 1 of 3 RLH (polyclonal by immunophenotyping) and 1 ALH. BCL2-IgH [t(14;18)] rearrangement was seen in 8 of 12 cases (1 FL, 3 DLBCLs, 4 MALTLs) by real-time quantitative PCR. INTERPRETATION: Conjunctival lymphomas are predominantly B-cell type with a high prevalence of MALTL. An unexpected finding was the BCL2-IgH rearrangement seen in 4 of 5 MALTL cases in our series. The significance of this remains unclear.
Explore the source record for details and available documents.
BACKGROUND: Lacrimal gland lymphoproliferative disorders are usually classified as orbital adnexal tumours. Because the lacrimal gland is the only orbital structure with native lymphocytes, we examined cases with primary involvement of the gland. METHODS: The 14 cases were selected from a review of all cases in the surgical pathology files of the Ottawa Hospital between 1992 and 2003. The lesions were categorized according to the latest World Health Organization classification of tumours of lymphoid tissues. We conducted a clinical, histopathological, immunohistochemical, immunophenotypic and molecular genetic analysis of the cases. RESULTS: The 8 female and 6 male patients, aged 20 to 88 (mean 60) years, were followed for an average of 4 years (range 11 months to 13 years). All presented with supratemporal orbital swelling. The 5 primary lymphomas, of mucosa-associated lymphoid tissue (MALT), were confined to the lacrimal gland (stage IE); 1 tumour transformed to diffuse large B-cell lymphoma, necessitating chemotherapy, and the other 4 were treated with radiation. One of the 5 patients had previously had Sjögren's syndrome. The 6 secondary lymphomas (4 follicular) presented either concurrently with systemic lymphoma or up to 12 years afterwards and were treated in a variety of ways; all the patients had an orbital relapse. At the last follow-up assessment, 6 of the patients with lymphoma had no evidence of disease, 3 were alive with disease, 2 had died (1 of lymphoma, the other with no evidence of disease), and the status of 1 patient was not known. Of the 3 patients with reactive proliferations, 2 had reactive lymphoid hyperplasia (associated with Sjögren's syndrome in 1), and 1 had Rosai-Dorfman disease. All 9 lymphomas that underwent molecular genetic analysis were of B-cell lineage, and 8 had a monoclonal rearrangement in the immunoglobulin heavy-chain gene (IgH); the 9th lymphoma showed an oligoclonal rearrangement. One lymphoma showed the t(14;18) translocation, typical of follicular lymphoma; no lymphoma showed the t(11;18) translocation, commonly found in MALT lymphoma (but only 2 cases were studied). Molecular genetic analysis was performed in 2 of the cases of reactive lymphoid hyperplasia: monoclonal IgH rearrangement was detected in 1 case (the patient with Sjögren's syndrome), oligoclonal rearrangement in the other. INTERPRETATION: Lacrimal gland lymphomas are B-cell tumours that develop in older adults. Primary tumours, a hIgH proportion of which have MALT characteristics, have a favourable prognosis. Molecular genetic studies may be useful when morphologic and immunophenotypic studies give equivocal results.
Explore the source record for details and available documents.
PURPOSE: To determine and compare the amount of force required to disrupt the integrity of various orbital implants. METHODS: Compression tests were carried out by using a servo-electrical universal testing system on orbital implants including aluminum oxide (Bioceramic implant, FCI, Issy-Les-Moulineaux, France), coralline hydroxyapatite (HA) (Bio-Eye, Integrated Orbital Implants, Inc., San Diego, CA, U.S.A.), bovine HA (Molteno M-Sphere, IOP Inc., Costa Mesa, CA, U.S.A.), synthetic HA (FCI3, FCI, Issy-Les-Moulineaux, France), Chinese HA (H + Y Comprehensive technologies, Philadelphia, PA, U.S.A.), polylactic acid (Kinsey Nash Corporation, Duluth, MN, U.S.A.), porous polyethylene (Medpor, Porex Surgical Inc., College Park, GA, U.S.A.), and polymethylmethacrylate. RESULTS: Two basic groups of implants were identified: those that eventually reach a critical compression point and collapse (coralline HA, aluminum oxide, synthetic FCI3 HA, bovine HA, Chinese HA, and polymethylmethacrylate), and those that do not collapse but gradually compress with increasing load (porous polyethylene, polylactic acid). For similar-sized implants, the critical collapse point was earliest for the FCI3 HA implant, followed by the coralline HA, aluminum oxide, and polymethylmethacrylate implants. Smaller-sized collapsible implants showed earlier critical collapse points than larger-sized implants of similar material. CONCLUSIONS: A technique was established to assess the force required to disrupt the integrity of various orbital implants that is reliable, unbiased, and repeatable with any orbital implant. Orbital implants of different materials and sizes demonstrate different degrees of integrity. It is important to use similar-sized implants when comparing the integrity of different implant materials because size influences the force required to overcome the structural integrity of the implant.
A 45-year-old man received an injection of Restylane (cross-linked hyaluronic acid) to a mid-forehead furrow line in an attempt to reduce its prominence. The injection was uncomplicated and successful in reducing the line. Five months after the injection, he returned with an inflammatory reaction in the area of injection that resolved without treatment over a period of 3 weeks.
PURPOSE: To describe a technique for localizing extraocular muscles during secondary orbital implantation and to report the author's experience in 100 consecutive cases. DESIGN: Retrospective, noncomparative, consecutive case series. PARTICIPANTS AND METHODS: A retrospective review was performed of the charts from one surgeon's practice of 100 consecutive patients who received a secondary porous orbital implant for anophthalmic socket rehabilitation. The following data were recorded: age, gender, reason for seeking secondary implantation, type of implant used, size and style of implant used, number of muscles localized, follow-up duration, and problems encountered and their treatment. Preoperative and postoperative photographs, implant motility, prosthetic motility, and overall impressions (by patient and physician) of the surgical outcome were analyzed. RESULTS: The 100 patients (66 males and 34 females, with a mean age of 38.9 years) were followed up for an average of 16.9 months (range, 4-60 months). All 4 rectus muscles were identified in 93 patients, 3 recti were identified in 6 patients, and 2 recti were identified in 1 patient. In 2 patients, the levator muscle mistakenly was thought to be the superior rectus muscle and was connected to the implant. Reconstructive surgical procedures were required in both cases. At final follow-up, 98% of patients believed that they had benefited from surgery, with an improved prosthetic appearance, improved symmetry between the 2 eyes, improved comfort, better prosthetic motility, or a combination thereof. Compared with the results of the preoperative examination, implant and prosthetic motility was improved in 92% to 98% of patients. CONCLUSIONS: The tunnel technique allows successful localization of extraocular muscles during secondary orbital implant surgery in a high percentage of patients. Surgical outcomes were excellent, with few complications and high patient satisfaction.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We describe a case of a 32-year-old man who presented with a visually apparent but otherwise asymptomatic mass in the right lateral fornix. Computerized tomography demonstrated the mass adjacent to the lacrimal gland. The mass was surgically removed, and histopathologic examination was consistent with a dacryolith of the lacrimal ductule. There were several cilia isolated from the dacryolith. This entity should be considered in the differential diagnosis of patients presenting with a localized mass in the region of the lacrimal gland.
PURPOSE: To assess the problems seen in 158 patients with coralline hydroxyapatite (HA) orbital implants (Bio-Eye). METHODS: A consecutive case series of 170 patients receiving coralline HA implanted by two surgeons over a 5-year period were reviewed. The authors analyzed age, type of surgery, implant size, peg system, follow-up duration, time of pegging, problems encountered, and treatment. RESULTS: Twelve patients were lost to follow-up after 5 months, leaving 158 patients who were followed from 6 to 130 months (average, 39 months). Problems in unpegged implants occurred in 36 (22.8%) patients. Discharge occurred in 18 (11.4%) patients, implant exposure in 12 (7.6%), socket discomfort in 1 (0.6%), conjunctival thinning in 3 (1.9%), chronic conjunctival swelling in 2 (1.3%), and implant infection in 3 (1.9%). Problems after pegging occurred in 68 (50.7%) of 134 patients: discharge in 27 (20.1%), pyogenic granuloma in 24 (17.9%), conjunctiva overgrowing the peg in 4 (3.0%), implant exposure around the sleeve in 5 (3.7%), clicking in 6 (4.5%), peg on an angle in 2 (1.5%), loose sleeve in 1 (0.7%), peg falling out in 18 (13.4%), popping peg in 1 (0.7%), poor transfer of movement in 3 (2.2%), pain with movement in 1 (0.7%), and implant infection in 2 (1.5%). CONCLUSIONS: The Bio-Eye orbital implant represents a porous orbital implant that is biocompatible with orbital tissues and allows fibrovascular ingrowth and improved motility when coupled to the overlying artificial eye. It is more expensive than other commercially available porous orbital implants, such as synthetic FCI3 HA, porous polyethylene (Medpor), and aluminum oxide (Bioceramic) implant. Problems encountered with its use are similar to those problems seen in patients with the synthetic FCI3 hydroxyapatite and aluminum oxide orbital implants.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
PURPOSE: To explore the feasibility of designing, constructing, and testing an orbital endoscope for use with the free electron laser (FEL). METHODS: An experimental study with an author-designed laser delivery system through an endoscope was conducted. Two adult pig cadavers and 6 fresh human cadavers had orbital endoscopy performed to develop a method of optic nerve sheath fenestration (ONSF) with the FEL. Twelve orbits were used to develop the surgical procedure by comparing visualization media and surgical technique. In the first 7 trials, a different variable was changed; the procedure was then refined in the human cadaver experiments. An ONSF was performed with the FEL (6.45 microm, 30 Hz, 2 to 3 mJ, 250-microm spot size) through a glass hollow wave guide introduced through an endoscope in 4 human cadaver orbits. RESULTS: Visualization of the orbital structures was clearest with carbon dioxide; sodium hyaluronate did not displace the fat, and saline hydrated the orbital fat. Biopsy forceps alone did not produce a dural window in the four trials that used the forceps. A dural window was made by using the FEL through a glass hollow wave guide adapted to the Olympus HYF-XP endoscope in the second, third, fifth, and sixth human trials with the FEL. Histologic evidence of the ONSF was produced. CONCLUSIONS: A hollow wave guide capable of transmitting the FEL through an endoscope was successfully constructed. ONSF with the FEL applied through an endoscope is technically feasible. Additional studies are currently examining techniques to improve intraorbital endoscopy.
PURPOSE: To report the clinical findings, treatment, outcomes, and histopathologic findings in patients with suspected orbital implant infection requiring implant removal. METHODS: Retrospective, observational case series of 14 patients (15 hydroxyapatite orbital implants) undergoing implant removal from September 1994 through December 2002. Patient age, type of surgery, implant type, symptoms, treatment, histopathology of implant, and follow-up course were analyzed. RESULTS: Of the 14 patients, 7 were female and 7 were male. The mean age at explantation was 42 years. The most common symptoms were discharge and socket tenderness. The most common signs were conjunctival inflammation (edema, hyperemia), discharge, and recurrent pyogenic granuloma. Clinical evidence of infection was documented in 13 patients. Histopathologic assessment of the 15 explanted implants showed acute inflammation and necrosis (abscess) with identification of microorganisms (5 patients), acute inflammation and necrosis without identification of microorganisms (4 patients), chronic inflammation with identification of microorganisms (1 patient), chronic inflammation without identification of microorganisms (3 patients), and a predominant foreign body granulomatous response without identification of microorganisms (2 patients). Osseous metaplasia was seen in 10 implants. Prompt resolution of symptoms and signs occurred in all but one case. CONCLUSIONS: The clinical course of porous orbital implant infection may be prolonged, and the early symptom of recurrent discharge, a common problem for implant recipients, may delay diagnosis. Implant infection should be suspected when there is persistent conjunctival inflammation and discharge after implant placement despite antibiotic therapy, discomfort on implant palpation, and recurrent pyogenic granuloma (indicative of implant exposure). Implant removal is usually required in these cases. If orbital pain (not necessarily related to implant palpation) is the main complaint, without signs of conjunctival inflammation and with or without discharge, one should consider other reasons for the symptoms.
: The authors report the case of a 32-year-old woman who presented with bilateral lower eyelid swelling and extraocular muscle enlargement as the initial manifestation of acromegaly. The acromegaly, however, was not diagnosed until 6 years after her symptoms began. Acromegaly should be entertained in the differential diagnosis of any patient who presents with bilateral, symmetrical extraocular muscle enlargement on computed tomographic scan, especially in the patient with normal thyroid hormone levels and no clinical findings associated with thyroid orbitopathy.