David R S Cumming

Publications and source records attributed to David R S Cumming.

8 recordsLinked to original sources

Construction and characterization of a gold nanoparticle wire assembled using Mg2+-dependent RNA-RNA interactions.

Magnesium-ion-mediated RNA-RNA loop-receptor interactions, in conjunction with gold nanoparticles derivatized with DNA, have been used to make self-assembled nanowires. A wire located between lithographically fabricated nanoelectrodes is demonstrated that exhibits activated conduction by electron hopping at temperatures in the 150-300 K range. These techniques have the ability to link particles between devices and in the future may be used to assemble practical circuits.

Base Sequence↗

Biocompatibility of a lab-on-a-pill sensor in artificial gastrointestinal environments.

In this paper, we present a radiotelemetry sensor, designed as a lab-in-a-pill, which incorporates a two-channel microfabricated sensor platform for real-time measurements of temperature and pH. These two parameters have potential application for use in remote biological sensing (for example they may be used as markers that reflect the physiological environment or as indicators for disease, within the gastrointestinal tract). We have investigated the effects of biofouling on these sensors, by exploring their response time and sensitivity in a model in vitro gastrointestinal system. The artificial gastric and intestinal solutions used represent a model both for fasting, as well as for the ingestion of food and subsequent digestion to gastrointestinal chyme. The results showed a decrease in pH sensitivity after exposure of the sensors for 3 h. The response time also increased from an initial measurement time of 10 s in pure GI juice, to ca. 25 s following the ingestion of food and 80 s in simulated chyme. These in vitro results indicate that changes in viscosity in our model gastrointestinal system had a pronounced effect on the unmodified sensor.

Biocompatible Materials↗

Implementation of radiotelemetry in a lab-in-a-pill format.

A miniaturised lab-in-a-pill device has been produced incorporating a temperature and pH sensor with wireless communication using the 433.92 MHz ISM band. The device has been designed in order to enable real time in situ measurements in the gastrointestinal (GI) tract, and accordingly, issues concerning the resolution and accuracy of the data, and the lifetime of the device have been considered. The sensors, which will measure two key parameters reflecting the physiological environment in the GI (as indicators for disease) were both controlled by an application specific integrated circuit (ASIC). The data were sampled at 10-bit resolution prior to communication off chip as a single interleaved data stream. This incorporated a power saving serial bitstream data compression algorithm that was found to extend the service lifetime of the pill by 70%. An integrated on-off keying (OOK) radio transmitter was used to send the signal to a local receiver (base station), prior to acquisition on a computer. A permanent magnet was also incorporated in the device to enable non-visual tracking of the system. We report on the implementation of this device, together with an initial study sampling from within the porcine GI tract, showing that measurements from the lab-on-a-pill, in situ, was within 90% of literature values.

Animals↗

A system-on-chip digital pH meter for use in a wireless diagnostic capsule.

This paper describes the design and implementation of a system-on-chip digital pH meter, for use in a wireless capsule application. The system is organized around an 8-bit microcontroller, designed to be functionally identical to the Motorola 6805. The analog subsystem contains a floating-electrode ISFET, which is fully compatible with a commercial CMOS process. On-chip programmable voltage references and multiplexors permit flexibility with the minimum of external connections. The chip is designed in a modular fashion to facilitate verification and component re-use. The single-chip pH meter can be directly connected to a personal computer, and gives a response of 37 bits/pH, within an operating range of 7 pH units.

Algorithms↗

A programmable microsystem using system-on-chip for real-time biotelemetry.

A telemetry microsystem, including multiple sensors, integrated instrumentation and a wireless interface has been implemented. We have employed a methodology akin to that for System-on-Chip microelectronics to design an integrated circuit instrument containing several "intellectual property" blocks that will enable convenient reuse of modules in future projects. The present system was optimized for low-power and included mixed-signal sensor circuits, a programmable digital system, a feedback clock control loop and RF circuits integrated on a 5 mm x 5 mm silicon chip using a 0.6 microm, 3.3 V CMOS process. Undesirable signal coupling between circuit components has been investigated and current injection into sensitive instrumentation nodes was minimized by careful floor-planning. The chip, the sensors, a magnetic induction-based transmitter and two silver oxide cells were packaged into a 36 mm x 12 mm capsule format. A base station was built in order to retrieve the data from the microsystem in real-time. The base station was designed to be adaptive and timing tolerant since the microsystem design was simplified to reduce power consumption and size. The telemetry system was found to have a packet error rate of 10(-3) using an asynchronous simplex link. Trials in animal carcasses were carried out to show that the transmitter was as effective as a conventional RF device whilst consuming less power.

Computer Systems↗

A direct-sequence spread-spectrum communication system for integrated sensor microsystems.

Some of the most important challenges in health-care technologies have been identified to be development of noninvasive systems and miniaturization. In developing the core technologies, progress is required in pushing the limits of miniaturization, minimizing the costs and power consumption of microsystems components, developing mobile/wireless communication infrastructures and computing technologies that are reliable. The implementation of such miniaturized systems has become feasible by the advent of system-on-chip technology, which enables us to integrate most of the components of a system on to a single chip. One of the most important tasks in such a system is to convey information reliably on a multiple-access-based environment. When considering the design of telecommunication system for such a network, the receiver is the key performance critical block. The paper describes the application environment, the choice of the communication protocol, the implementation of the transmitter and receiver circuitry, and research work carried out on studying the impact of input data characteristics and internal data path complexity on area and power performance of the receiver. We provide results using a test data recorded from a pH sensor. The results demonstrate satisfying functionality, area, and power constraints even when a degree of programmability is incorporated in the system.

Biosensing Techniques↗

Implementation of multichannel sensors for remote biomedical measurements in a microsystems format.

A novel microelectronic "pill" has been developed for in situ studies of the gastro-intestinal tract, combining microsensors and integrated circuits with system-level integration technology. The measurement parameters include real-time remote recording of temperature, pH, conductivity, and dissolved oxygen. The unit comprises an outer biocompatible capsule encasing four microsensors, a control chip, a discrete component radio transmitter, and two silver oxide cells (the latter providing an operating time of 40 h at the rated power consumption of 12.1 mW). The sensors were fabricated on two separate silicon chips located at the front end of the capsule. The robust nature of the pill makes it adaptable for use in a variety of environments related to biomedical and industrial applications.

Biomedical Engineering↗

Electromagnetic radiation from ingested sources in the human intestine between 150 MHz and 1.2 GHz.

The conventional method of diagnosing disorders of the human gastro-intestinal (GI) tract is by sensors embedded in cannulae that are inserted through the anus, mouth, or nose. However, these cannulae cause significant patient discomfort and cannot be used in the small intestine. As a result, there is considerable ongoing work in developing wireless sensors that can be used in the small intestine. The radiation characteristics of sources in the GI tract cannot be readily calculated due to the complexity of the human body and its composite tissues, each with different electrical characteristics. In addition, the compact antennas used are electrically small, making them inefficient radiators. This paper presents radiation characteristics for sources in the GI tract that should allow for the optimum design of more efficient telemetry systems. The characteristics are determined using the finite-difference time-domain method with a realistic antenna model on an established fully segmented human body model. Radiation intensity outside the body was found to have a Gaussian-form relationship with frequency. Maximum radiation occurs between 450 and 900 MHz. The gut region was found generally to inhibit vertically polarized electric fields more than horizontally polarized fields.

Adult↗