Optimization of a tomosynthesis system for the detection of lung nodules.

Mathematical observers that track human performance can be used to reduce the number of human observer studies needed to optimize imaging systems. The performance of human observers for the detection of a 3.6 mm lung nodule in anatomical backgrounds was measured as a function of varying tomosynthetic angle and compared with mathematical observers. The human observer results showed a dramatic increase in the percent of correct responses, from 80% in the projection images to 96% in the projection images with a tomosynthetic angle of just 3 degrees. This result suggests the potential usefulness of the scanned beam digital x-ray system for this application. Given the small number of images (40) used per tomosynthetic angle and the highly nonstationary statistical nature of the backgrounds, the nonprewhitening eye observer achieved a higher performance than the channelized Hotelling observer using a Laguerre-Gauss basis. The channelized Hotelling observer with internal noise and the eye filter matched to the projection data were shown to track human performance as the tomosynthetic angle changed. The validation of these mathematical observers extends their applicability to the optimization of tomosynthesis systems.

Algorithms↗

CT colonography: influence of 3D viewing and polyp candidate features on interpretation with computer-aided detection.

PURPOSE: To retrospectively determine if three-dimensional (3D) viewing improves radiologists' accuracy in classifying true-positive (TP) and false-positive (FP) polyp candidates identified with computer-aided detection (CAD) and to determine candidate polyp features that are associated with classification accuracy, with known polyps serving as the reference standard. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained; this study was HIPAA compliant. Forty-seven computed tomographic (CT) colonography data sets were obtained in 26 men and 10 women (age range, 42-76 years). Four radiologists classified 705 polyp candidates (53 TP candidates, 652 FP candidates) identified with CAD; initially, only two-dimensional images were used, but these were later supplemented with 3D rendering. Another radiologist unblinded to colonoscopy findings characterized the features of each candidate, assessed colon distention and preparation, and defined the true nature of FP candidates. Receiver operating characteristic curves were used to compare readers' performance, and repeated-measures analysis of variance was used to test features that affect interpretation. RESULTS: Use of 3D viewing improved classification accuracy for three readers and increased the area under the receiver operating characteristic curve to 0.96-0.97 (P<.001). For TP candidates, maximum polyp width (P=.038), polyp height (P=.019), and preparation (P=.004) significantly affected accuracy. For FP candidates, colonic segment (P=.007), attenuation (P<.001), surface smoothness (P<.001), distention (P=.034), preparation (P<.001), and true nature of candidate lesions (P<.001) significantly affected accuracy. CONCLUSION: Use of 3D viewing increases reader accuracy in the classification of polyp candidates identified with CAD. Polyp size and examination quality are significantly associated with accuracy.

Adult↗

Pulmonary nodules on multi-detector row CT scans: performance comparison of radiologists and computer-aided detection.

PURPOSE: To compare the performance of radiologists and of a computer-aided detection (CAD) algorithm for pulmonary nodule detection on thin-section thoracic computed tomographic (CT) scans. MATERIALS AND METHODS: The study was approved by the institutional review board. The requirement of informed consent was waived. Twenty outpatients (age range, 15-91 years; mean, 64 years) were examined with chest CT (multi-detector row scanner, four detector rows, 1.25-mm section thickness, and 0.6-mm interval) for pulmonary nodules. Three radiologists independently analyzed CT scans, recorded the locus of each nodule candidate, and assigned each a confidence score. A CAD algorithm with parameters chosen by using cross validation was applied to the 20 scans. The reference standard was established by two experienced thoracic radiologists in consensus, with blind review of all nodule candidates and free search for additional nodules at a dedicated workstation for three-dimensional image analysis. True-positive (TP) and false-positive (FP) results and confidence levels were used to generate free-response receiver operating characteristic (ROC) plots. Double-reading performance was determined on the basis of TP detections by either reader. RESULTS: The 20 scans showed 195 noncalcified nodules with a diameter of 3 mm or more (reference reading). Area under the alternative free-response ROC curve was 0.54, 0.48, 0.55, and 0.36 for CAD and readers 1-3, respectively. Differences between reader 3 and CAD and between readers 2 and 3 were significant (P < .05); those between CAD and readers 1 and 2 were not significant. Mean sensitivity for individual readings was 50% (range, 41%-60%); double reading resulted in increase to 63% (range, 56%-67%). With CAD used at a threshold allowing only three FP detections per CT scan, mean sensitivity was increased to 76% (range, 73%-78%). CAD complemented individual readers by detecting additional nodules more effectively than did a second reader; CAD-reader weighted kappa values were significantly lower than reader-reader weighted kappa values (Wilcoxon rank sum test, P < .05). CONCLUSION: With CAD used at a level allowing only three FP detections per CT scan, sensitivity was substantially higher than with conventional double reading.

Adolescent↗

The histone deacetylase inhibitor MS-275 interacts synergistically with fludarabine to induce apoptosis in human leukemia cells.

Interactions between the novel benzamide histone deacetylase (HDAC) inhibitor MS-275 and fludarabine were examined in lymphoid and myeloid human leukemia cells in relation to mitochondrial injury, signal transduction events, and apoptosis. Prior exposure of Jurkat lymphoblastic leukemia cells to a marginally toxic concentration of MS-275 (e.g., 500 nM) for 24 h sharply increased mitochondrial injury, caspase activation, and apoptosis in response to a minimally toxic concentration of fludarabine (500 nM), resulting in highly synergistic antileukemic interactions and loss of clonogenic survival. Simultaneous exposure to MS-275 and fludarabine also led to synergistic effects, but these were not as pronounced as observed with sequential treatment. Similar interactions were noted in the case of (a) other human leukemia cell lines (e.g., U937, CCRF-CEM); (b) other HDAC inhibitors (e.g., sodium butyrate); and (c) other nucleoside analogues (e.g., 1-beta-D-arabinofuranosylcytosine, gemcitabine). Potentiation of fludarabine lethality by MS-275 was associated with acetylation of histones H3 and H4, down-regulation of the antiapoptotic proteins XIAP and Mcl-1, enhanced cytosolic release of proapoptotic mitochondrial proteins (e.g., cytochrome c, Smac/DIABLO, and apoptosis-inducing factor), and caspase activation. It was also accompanied by the caspase-dependent down-regulation of p27(KIP1), cyclins A, E, and D(1), and cleavage and diminished phosphorylation of retinoblastoma protein. However, increased lethality of the combination was not associated with enhanced fludarabine triphosphate formation or DNA incorporation and occurred despite a slight reduction in the S-phase fraction. Prior exposure to MS-275 attenuated fludarabine-mediated activation of MEK1/2, extracellular signal-regulated kinase, and Akt, and enhanced c-Jun NH(2)-terminal kinase phosphorylation; furthermore, inducible expression of constitutively active MEK1/2 or Akt significantly diminished MS-275/fludarabine-induced lethality. Combined exposure of cells to MS-275 and fludarabine was associated with a significant increase in generation of reactive oxygen species; moreover, both the increase in reactive oxygen species and apoptosis were largely attenuated by coadministration of the free radical scavenger L-N-acetylcysteine. Finally, prior administration of MS-275 markedly potentiated fludarabine-mediated generation of the proapoptotic lipid second messenger ceramide. Taken together, these findings indicate that the HDAC inhibitor MS-275 induces multiple perturbations in signal transduction, survival, and cell cycle regulatory pathways that lower the threshold for fludarabine-mediated mitochondrial injury and apoptosis in human leukemia cells. They also provide insights into possible mechanisms by which novel, clinically relevant HDAC inhibitors might be used to enhance the antileukemic activity of established nucleoside analogues such as fludarabine.

Antineoplastic Combined Chemotherapy Protocols↗

Surface normal overlap: a computer-aided detection algorithm with application to colonic polyps and lung nodules in helical CT.

We developed a novel computer-aided detection (CAD) algorithm called the surface normal overlap method that we applied to colonic polyp detection and lung nodule detection in helical computed tomography (CT) images. We demonstrate some of the theoretical aspects of this algorithm using a statistical shape model. The algorithm was then optimized on simulated CT data and evaluated using a per-lesion cross-validation on 8 CT colonography datasets and on 8 chest CT datasets. It is able to achieve 100% sensitivity for colonic polyps 10 mm and larger at 7.0 false positives (FPs)/dataset and 90% sensitivity for solid lung nodules 6 mm and larger at 5.6 FP/dataset.

Algorithms↗

Registration of central paths and colonic polyps between supine and prone scans in computed tomography colonography: pilot study.

Computed tomography colonography (CTC) is a minimally invasive method that allows the evaluation of the colon wall from CT sections of the abdomen/pelvis. The primary goal of CTC is to detect colonic polyps, precursors to colorectal cancer. Because imperfect cleansing and distension can cause portions of the colon wall to be collapsed, covered with water, and/or covered with retained stool, patients are scanned in both prone and supine positions. We believe that both reading efficiency and computer aided detection (CAD) of CTC images can be improved by accurate registration of data from the supine and prone positions. We developed a two-stage approach that first registers the colonic central paths using a heuristic and automated algorithm and then matches polyps or polyp candidates (CAD hits) by a statistical approach. We evaluated the registration algorithm on 24 patient cases. After path registration, the mean misalignment distance between prone and supine identical anatomic landmarks was reduced from 47.08 to 12.66 mm, a 73% improvement. The polyp registration algorithm was specifically evaluated using eight patient cases for which radiologists identified polyps separately for both supine and prone data sets, and then manually registered corresponding pairs. The algorithm correctly matched 78% of these pairs without user input. The algorithm was also applied to the 30 highest-scoring CAD hits in the prone and supine scans and showed a success rate of 50% in automatically registering corresponding polyp pairs. Finally, we computed the average number of CAD hits that need to be manually compared in order to find the correct matches among the top 30 CAD hits. With polyp registration, the average number of comparisons was 1.78 per polyp, as opposed to 4.28 comparisons without polyp registration.

Algorithms↗

CT colonography: does improved z resolution help computer-aided polyp detection?

Multislice helical CT offers several retrospective choices of longitudinal (z) resolution at a given detector collimation setting. We sought to determine the effect of z resolution on the performance of a computer-aided colonic polyp detector, since a human reader and a computer-aided polyp detector may have optimal performances at different z resolutions. We ran a computer-aided polyp detection algorithm on phantom data sets as well as data obtained from a single patient. All data were reconstructed at various slice thicknesses ranging from 1.25 to 10 mm. We studied the performance of the detector at various ranges of polyp sizes using free-response receiver-operating characteristic analyses. We also studied contrast-to-noise ratios (CNR) as a function of slice thickness and polyp size. For the phantom data, reducing the slice thickness from 5 to 1.25 mm improves sensitivity from 84.5% to 98.3% (all polyps), from 61.4% to 95.5% (polyps in the range [0, 5) mm) and from 97.7% to 100% (polyps in the range [5, 10) mm) at a false positive rate of 20 per data set. For polyps larger than 10 mm, there is no significant improvement in detection sensitivity when slice thickness is reduced. CNRs showed expected behavior with slice thickness and polyp size, but in all cases remained high (> 4). The results for the patient data followed similar patterns to that of the phantom case. Thus we conclude that for this detector, the optimal slice thickness is dependent upon the size of the smallest polyps to be detected. For detection of polyps 10 mm and larger, reconstruction of 5 mm sections may be sufficient. Further study is required to generalize these results to a broader population of patients scanned on different scanners.

Colon↗

Improved renal clearance and tumor targeting of 99mTc-labeled anti-Tac monoclonal antibody Fab by chemical modifications.

This study was undertaken to improve the renal clearance and tumor targeting properties of 99mTc-labeled humanized anti-Tac (HuTac) monoclonal antibody Fab fragments using two chemical approaches: 1) labeling with a renal secretion agent 99mTc-mercaptoacetyltriglycine (MAG3) and 2) lowering its isoelectric point (pI) by acylation. HuTac Fab (3.3 mg/mL) was reacted with a trifluorophenyl ester (TFP) of 99mTc-MAG3 alone or was additionally reacted with TFP-glycolate to reduce the pI. In Balb/c mice, 99mTc-MAG3-Fab (pI > 9.3) rapidly accumulated in the kidneys (177% injected dose [ID]/g at 15 min) and then gradually cleared out of the kidneys. In contrast, the glycolation (pI 4.6 approximately 6.6) drastically reduced the renal uptake (31% ID/g) and also the whole-body retention (82% ID vs 101% for the nonglycolated) at 15 min, indicating that the glycolated 99mTc-MAG3-Fab (pI 4.6 approximately 6.6) was rapidly excreted. The glycolated remained in the blood longer than the nonglycolated (1.2% vs 0.3% ID/g at 360 min), but this effect was less drastic than the effect shown on the renal uptake. In nude mice bearing receptor-positive (ATAC4) tumors, the glycolated 99mTc-MAG3-Fab increased the peak tumor uptake to 14.8% ID/g from 8.3% ID/g for 99mTc-MAG3-Fab, whereas the glycolation resulted in a drastic reduction of the renal uptake at 15 min. We demonstrated that the renal clearance and the tumor targeting of Fab could be optimized by chemical modifications.

Animals↗

Edge displacement field-based classification for improved detection of polyps in CT colonography.

Colorectal cancer can easily be prevented provided that the precursors to tumors, small colonic polyps, are detected and removed. Currently, the only definitive examination of the colon is fiber-optic colonoscopy, which is invasive and expensive. Computed tomographic colonography (CTC) is potentially a less costly and less invasive alternative to FOC. It would be desirable to have computer-aided detection (CAD) algorithms to examine the large amount of data CTC provides. Most current CAD algorithms have high false positive rates at the required sensitivity levels. We developed and evaluated a postprocessing algorithm to decrease the false positive rate of such a CAD method without sacrificing sensitivity. Our method attempts to model the way a radiologist recognizes a polyp while scrolling a cross-sectional plane through three-dimensional computed tomography data by classification of the changes in the location of the edges in the two-dimensional plane. We performed a tenfold cross-validation study to assess its performance using sensitivity/specificity analysis on data from 48 patients. The mean specificity over all experiments increased from 0.19 (0.35) to 0.47 (0.56) for a sensitivity of 1.00 (0.95).

Adult↗

Carotid disease: automated analysis with cardiac-gated three-dimensional US technique and preliminary results.

Automatic analysis was performed of four-dimensional ultrasonographic (US) data in the carotid artery. The data, which were acquired in 31 subjects (eight healthy volunteers and 23 patients) by using a US scanner fitted with a special probe, were successfully processed. Acquisition time averaged 12 minutes. Data for all healthy volunteers (n = 8) and patients with complete occlusions (n = 3) were correctly classified. Data for two of the 12 patients with mild to severe (but not occlusive) disease were misclassified by one category.

Adult↗

Quantification of distention in CT colonography: development and validation of three computer algorithms.

Three bowel distention-measuring algorithms for use at computed tomographic (CT) colonography were developed, validated in phantoms, and applied to a human CT colonographic data set. The three algorithms are the cross-sectional area method, the moving spheres method, and the segmental volume method. Each algorithm effectively quantified distention, but accuracy varied between methods. Clinical feasibility was demonstrated. Depending on the desired spatial resolution and accuracy, each algorithm can quantitatively depict colonic diameter in CT colonography.

Algorithms↗

Computed tomography colonography: feasibility of computer-aided polyp detection in a "first reader" paradigm.

OBJECTIVE: : To determine the feasibility of a computer-aided detection (CAD) algorithm as the "first reader" in computed tomography colonography (CTC). METHODS: : In phase 1 of a 2-part blind trial, we measured the performance of 3 radiologists reading 41 CTC studies without CAD. In phase 2, readers interpreted the same cases using a CAD list of 30 potential polyps. RESULTS: : Unassisted readers detected, on average, 63% of polyps > or =10 mm in diameter. Using CAD, the sensitivity was 74% (not statistically different). Per-patient analysis showed a trend toward increased sensitivity for polyps > or =10 mm in diameter, from 73% to 90% with CAD (not significant) without decreasing specificity. Computer-aided detection significantly decreased interobserver variability (P = 0.017). Average time to detection of the first polyp decreased significantly with CAD, whereas total reading case reading time was unchanged. CONCLUSION: : Computer-aided detection as a first reader in CTC was associated with similar per-polyp and per-patient detection sensitivity to unassisted reading. Computer-aided detection decreased interobserver variability and reduced the time required to detect the first polyp.

Adult↗