PubMed Health⌕ Search

Biomedical subjects

David T Lai

Publications and source records attributed to David T Lai.

At least 19 recordsLinked to original sources

Mitral leaflet remodeling in dilated cardiomyopathy.

BACKGROUND: Normal mammalian mitral leaflets have regional heterogeneity of biochemical composition, collagen fiber orientation, and geometric deformation. How leaflet shape and regional geometry are affected in dilated cardiomyopathy is unknown. METHODS AND RESULTS: Nine sheep had 8 radio-opaque markers affixed to the mitral annulus (MA), 4 markers sewn on the central meridian of the anterior mitral leaflet (AML) forming 4 distinct segments S1 to S4 and 2 on the posterior leaflet (PML) forming 2 distinct segments S5 and S6. Biplane videofluoroscopy and echocardiography were performed before and after rapid pacing (180 to 230 bpm for 15+/-6 days) sufficient to develop tachycardia-induced cardiomyopathy (TIC) and functional mitral regurgitation (FMR). Leaflet tethering was defined as change of displacement of AML and PML edge markers from the MA plane from baseline values while leaflet length was obtained by summing the segments between respective leaflet markers. With TIC, total AML and PML length increased significantly (2.11+/-0.16 versus 2.43+/-0.23 cm and 1.14+/-0.27 versus 1.33+/-0.25 cm before and after pacing for AML and PML, respectively; P<0.05 for both), but only segments near the edge of each leaflet (S4 lengthened by 23+/-17% and S5 by 24+/-18%; P<0.05 for both) had significant regional remodeling. AML shape did not change and no leaflet tethering was observed. CONCLUSIONS: TIC was not associated with leaflet tethering or shape change, but both anterior and posterior leaflets lengthened because of significant remodeling localized near the leaflet edge. Leaflet remodeling accompanies mitral regurgitation in cardiomyopathy and casts doubt on FMR being purely "functional" in etiology.

Animals↗

Annular height-to-commissural width ratio of annulolasty rings in vivo.

BACKGROUND: A "saddle-shaped" mitral annulus with an optimal ratio between annular height and commissural diameter may reduce leaflet and chordal stress and is purported to be conserved across mammalian species. Whether annuloplasty rings maintain this relationship is unknown. METHODS AND RESULTS: Twenty-three adult sheep underwent implantation of radiopaque markers on the left ventricle and mitral annulus. Eight animals underwent implantation of a Carpentier-Edwards Physio ring, 7 underwent a Medtronic Duran flexible ring, and 8 served as controls. Animals were studied with biplane videofluoroscopy 7 to 10 days postoperatively. Annular height and commissural width (CW) were determined from 3D marker coordinates, and annular height:CW ratio (AHWCR) was calculated. Annular height was similar in Control and Duran animals but significantly lower in the Physio group at end diastole (8.4+/-3.8, 6.7+/-2.3, and 3.4+/-0.6 mm, respectively, for Control, Duran, and Physio; ANOVA=0.005) and at end systole (14.5+/-6.2, 10.5+/-5.5, and 5.8+/-2.5 mm, respectively, for Control, Duran, and Physio; ANOVA=0.004). Both ring groups reduced CW significantly relative to Control. AHCWR did not differ between Control and Duran but was lower in Physio (23+/-11%, 24+/-7%, and 12+/-2% at end diastole and 42+/-17%, 37+/-17%, and 21+/-10% at end systole, respectively, for Control, Duran, and Physio, respectively; ANOVA <0.05 for both). CONCLUSIONS: Mitral annular height and AHWCR of the native valve were unchanged by a Duran ring, whereas the Physio ring led to a lower AHWCR. Theoretically, such a flexible annuloplasty ring may provide better leaflet stress distribution by maintaining normal AHWCR.

Animals↗

Effects of paracommissural septal-lateral annular cinching on acute ischemic mitral regurgitation.

BACKGROUND: Previous experimental studies demonstrated that central septal-lateral (SL) annular cinching (SLAC) abolishes acute ischemic mitral regurgitation (IMR), but whether localized cinching near the anterior (ACOM) or posterior (PCOM) commissure is equally effective is unknown. METHODS: Six adult sheep underwent implantation of 9 radiopaque markers on the left ventricle, 8 around the mitral annulus (MA) and 1 on each papillary muscle (PM) tip. Transannular SL sutures were placed at the valve center (CENT) and near ACOM and PCOM and externalized. Acute IMR was induced by proximal circumflex coronary snare occlusion. Biplane videofluoroscopy and transesophageal echocardiography were performed before and continuously during 3 episodes of myocardial ischemia including 20 seconds of SLAC at each different location. End-systolic MA SL dimension at each suture location and distances between the anterior and posterior PM tips and mid-septal annulus ("saddle horn") were calculated from the 3-dimensional (3D) marker coordinates. RESULTS: SLAC interventions in all 3 locations reduced the degree of IMR, but cinching at the center, SLAC(CENT), had a significantly greater effect on reducing the magnitude of IMR than SLAC(PCOM) or SLAC(ACOM) (mean grade of IMR reduction=1.0+/-0.5, 1.8+/-0.5, and 0.9+/-0.2 for SLAC(ACOM), SLAC(CENT), and SLAC(PCOM), respectively; P=0.044). Although ACOM and PCOM cinching reduced SL(CENT) somewhat, only SLAC(CENT) simultaneously reduced both SL(ACOM) and SL(PCOM) and also repositioned both PM tips closer to the annular saddle horn. CONCLUSIONS: SLAC in all 3 positions reduced acute IMR, but central SLAC cinching was most effective, reduced all mitral annular SL dimensions, and relocated both PM tips closer to the mid-septal annulus. Central SLAC is most capable of correcting the annular and subvalvular perturbations accompanying acute left ventricular ischemia that lead to IMR.

Acute Disease↗

Mitral annular size predicts Alfieri stitch tension in mitral edge-to-edge repair.

BACKGROUND AND AIM OF THE STUDY: Whilst increased 'Alfieri stitch' tension may reduce the durability of 'edge-to-edge' mitral repair, the factors affecting suture tension are unknown. In order to study hemodynamics and left ventricular (LV) and annular dynamics that determine suture tension, the central edge of the mitral leaflets was approximated with a miniature force transducer to measure leaflet tension (T) at the leaflet approximation point. METHODS: Eight sheep were studied under open-chest conditions immediately after surgical placement of a force transducer and implantation of radiopaque markers on the left ventricle and mitral annulus (MA). Hemodynamic variables were altered by two caval occlusion steps (deltaV1 and deltaV2) and dobutamine infusion. Three-dimensional marker coordinates were obtained by simultaneous biplane videofluoroscopy to measure LV volume, MA area (MAA) and septal-lateral (SL) annular dimension throughout the cardiac cycle. RESULTS: At baseline, peak Alfieri stitch tension (0.30 +/- 0.18 N) was observed 96 +/- 61 ms prior to end-diastole coincident with peak annular SL diameter (98 +/- 58 ms before end-diastole). Dobutamine infusion decreased suture tension (from 0.30 +/- 0.18 N to 0.20 +/- 0.12 N, p = 0.01), although peak systolic pressure increased significantly (138 +/- 19 versus 115 +/- 14 mmHg; p = 0.03). A regression model was fitted with the goal of interpreting the hemodynamic and geometric predictors of tension as their influence varied with time: Tt (N) = 0.1916 + 0.2115 x SL (cm) - 0.1996 x MAA/SL (cm2/cm) + ft x LVP (mmHg), where Tt is tension at any time during the cardiac cycle and ft is the time-varying coefficient of LVP. CONCLUSION: Tension on the leaflets in the edge-to-edge repair is determined primarily by MA SL size, and paradoxically is lower when the contractile state is enhanced. This indicates that annular and/or LV dilatation increase stitch tension and may adversely affect durability of the repair if concomitant ring annuloplasty is not performed.

Animals↗

Edge-to-edge mitral valve repair without ring annuloplasty for acute ischemic mitral regurgitation.

BACKGROUND: Alfieri edge-to-edge mitral repair has been used clinically with ring annuloplasty to correct ischemic mitral regurgitation (IMR), but its efficacy without concomitant ring annuloplasty has not been described in this setting. METHODS: Seventeen sheep underwent implantation of 9 radiopaque markers on the left ventricle, 8 on the mitral annulus (MA), 1 on each papillary muscle (PM) tip, and 1 on the anterior and posterior leaflet edges near the anterior and posterior commissures. Alfieri repair was performed in 7 animals, and 10 were controls. Biplane videofluoroscopy and transesophageal echocardiography (TEE) were performed (open chest) before and continuously during left circumflex coronary artery occlusion to induce acute IMR. MA area (MAA), anterior (APM), and posterior (PPM) papillary muscle tip distances to midseptal MA ("saddle horn"), and distance of each leaflet marker to the mitral annular plane were calculated from 3-dimensional marker coordinates at end-systole (ES). RESULTS: Severity of IMR was not different between groups (+1.9+/-0.7 versus +1.4+/-0.5 for Control and Alfieri, respectively; P=not significant [NS]). Mitral annular area (MAA; 21+/-15 versus 19+/-9%; P =NS) and septal-lateral (SL) annular diameter (12+/-6 versus 12+/-11%; P =NS) increased similarly during ischemia. While PPM-saddle horn distance increased in both groups (1.5+/-1.3 and 1.6+/-1.4 mm for Control and Alfieri, respectively; P<0.05 versus preischemia), APM-saddle horn distance increased in Control (1.0+/-1.2 mm; P=0.03) but not in the Alfieri animals (0.8+/-08 mm; P=0.07). Leaflet edge displacements from the annular plane during ischemia were similar in both groups. CONCLUSIONS: Alfieri repair did not prevent acute IMR nor alter ischemic valvular or subvalvular geometric perturbations. Adjunct surgical procedures, such as ring annuloplasty, are also necessary.

Acute Disease↗

Aorto-mitral annular dynamics.

BACKGROUND: The aortic and mitral valves are coupled through fibrous aorto-mitral continuity, but their synchronous dynamic physiology has not been completely characterized. METHODS: Seven sheep underwent implantation of five radiopaque markers on the left ventricle, 10 on the mitral annulus, and 3 on the aortic annulus. One of the mitral annulus markers was placed at the center of aorto-mitral continuity (mitral annulus "saddle horn"). Animals were studied with bi-plane videofluoroscopy 7 to 10 days postoperatively. Total circumference and lengths of mitral fibrous annulus, mitral muscular annulus, aortic fibrous annulus, and aortic muscular annulus were calculated throughout the cardiac cycle from three dimensional marker coordinates as was mitral annular area and aortic annular area. Aorto-mitral angle was determined as the angle between the centroid of the aortic annulus markers, the saddle horn, and the centroid of the mitral annulus markers. Aortic annulus and mitral annulus flexion was expressed as the difference between maximum and minimum values of the aortic and mitral annulus angles during the cardiac cycle. RESULTS: Mitral and aortic annular areas changed in roughly a reciprocal fashion during late diastole and early systole with an overall 32 +/- 8% change in aortic annular area and a 13 +/- 13% change in mitral annular area. Aortic fibrous annulus changed much less than aortic muscular annulus (6 +/- 2% vs 18 +/- 4%; p = 0.0003) as did mitral fibrous annulus relative to mitral muscular annulus (4 +/- 1% vs 8 +/- 2%; p = 0.004). Aortic annulus and mitral annulus flexion was 8 +/- 2 degrees and increased to 11 +/- 2 degrees (p = 0.009) with inotropic stimulation. CONCLUSIONS: Dynamic aortic and mitral annular area changes were not mediated through the anatomic fibrous continuity. Aorto-mitral flexion, which increased with enhanced contractility, may facilitate left ventricle ejection. The effect of valvular surgical interventions on aorto-mitral flexion needs further investigation.

Animals↗

Acute type A aortic dissection complicated by aortic regurgitation: composite valve graft versus separate valve graft versus conservative valve repair.

OBJECTIVE: To clarify the merits of various surgical approaches, we studied the outcome after composite valve graft versus separate valve and graft replacement versus conservative valve treatment with replacement of the ascending aorta in patients with acute type A aortic dissection complicated by aortic regurgitation. METHODS: Between 1967 and 1999, 123 patients (mean age 56 +/- 15 years) underwent composite valve graft replacement (n = 21), separate valve and graft replacement (n = 20), or conservative valve treatment (n = 82 [commissural resuspension in 46]); follow-up averaged 6.5 years (95% complete). RESULTS: The 30-day, 1-year, and 6-year survival estimates of 85% +/- 4%, 79% +/- 5%, and 69% +/- 5% (+/-1 standard error of mean), respectively, after conservative valve treatment were similar to 86% +/- 8%, 81% +/- 9%, and 65% +/- 16%, respectively, with composite valve graft replacement and better (but insignificantly so) than 70% +/- 10%, 70% +/- 10%, and 45% +/- 11%, respectively, with separate valve and graft replacement. The 6-year freedom from proximal reoperation was 95% +/- 3%, 89% +/- 10%, and 100% in conservative valve graft, separate valve and graft, and composite valve graft subgroups, respectively (P = not significant). Cox regression multivariable analysis identified that previous sternotomy (hazard ratio [or e(beta)] 95% confidence interval 1.4-10.9, P =.006), hypertension (0.99-2.9, P =.05), cardiac tamponade (1.1-4.0, P =.03), and stroke (1.7-7.0, P =.001) increased the hazard of death. No factors predicting a higher likelihood of late proximal reoperation were identified. CONCLUSIONS: In patients with acute type A aortic dissection and aortic regurgitation, there was no significant difference in overall survival or reoperation rates among these surgical approaches. We try to save the valve whenever possible unless the aortic root is pathologically dilated (eg, Marfan syndrome or annuloaortic ectasia) or destroyed by the dissection process, when composite valve graft or valve-sparing aortic root replacement is indicated.

Acute Disease↗

Ischemia in three left ventricular regions: Insights into the pathogenesis of acute ischemic mitral regurgitation.

BACKGROUND: Acute posterolateral left ventricular ischemia in sheep results in ischemic mitral regurgitation, but the effects of ischemia in other left ventricular regions on ischemic mitral regurgitation is unknown. METHODS: Six adult sheep had radiopaque markers placed on the left ventricle, mitral annulus, and anterior and posterior mitral leaflets at the valve center and near the anterior and posterior commissures. After 6 to 8 days, animals were studied with biplane videofluoroscopy and transesophageal echocardiography before and during sequential balloon occlusion of the left anterior descending, distal left circumflex, and proximal left circumflex coronary arteries. Time of valve closure was defined as the time when the distance between leaflet edge markers reached its minimum plateau, and systolic leaflet edge separation distance was calculated on the basis of left ventricular ejection. RESULTS: Only proximal left circumflex coronary artery occlusion resulted in ischemic mitral regurgitation, which was central and holosystolic. Delayed valve closure (anterior commissure, 58 +/- 29 vs 92 +/- 24 ms; valve center, 52 +/- 26 vs 92 +/- 23 ms; posterior commissure, 60 +/- 30 vs 94 +/- 14 ms; all P <.05) and increased leaflet edge separation distance during ejection (mean increase, 2.2 +/- 1.5 mm, 2.1 +/- 1.9 mm, and 2.1 +/- 1.5 mm at the anterior commissure, valve center, and posterior commissure, respectively; P <.05 for all) was seen during proximal left circumflex coronary artery occlusion but not during left anterior descending or distal left circumflex coronary artery occlusion. Ischemic mitral regurgitation was associated with a 19% +/- 10% increase in mitral annular area, and displacement of both papillary muscle tips away from the septal annulus at end systole. CONCLUSIONS: Acute ischemic mitral regurgitation in sheep occurred only after proximal left circumflex coronary artery occlusion along with delayed valve closure in early systole and increased leaflet edge separation throughout ejection in all 3 leaflet coaptation sites. The degree of left ventricular systolic dysfunction induced did not correlate with ischemic mitral regurgitation, but both altered valvular and subvalvular 3-dimensional geometry were necessary to produce ischemic mitral regurgitation during acute left ventricular ischemia.

Acute Disease↗

Tachycardia-induced cardiomyopathy in the ovine heart: mitral annular dynamic three-dimensional geometry.

BACKGROUND: Ring annuloplasty has been used to correct annular dilatation and mitral regurgitation in dilated cardiomyopathy, but little is known about the dynamic precise 3-dimensional geometry of the mitral annulus in this condition. METHODS: Nine sheep had radiopaque markers sewn to the mitral annulus, creating 8 distinct segments beginning at the posterior commissure (segments 1-4, septal mitral annulus; segments 5-8, lateral mitral annulus). Biplane videofluoroscopy and transesophageal echocardiography were performed before and after rapid pacing (180-230 min(-1) for 15 +/- 6 days) sufficient to develop tachycardia-induced cardiomyopathy and mitral regurgitation. Mitral annular segment contraction was defined as the percentage difference between maximum and minimum lengths. Mitral annular area and mitral annular septal-lateral and commissure-commissure diameters and 3-dimensional shape were determined from marker coordinates. RESULTS: With tachycardia-induced cardiomyopathy, end-diastolic mitral annular area, septal-lateral diameter, and commissure-commissure diameter increased by 36% +/- 14%, 25% +/- 12%, and 9% +/- 5%, respectively (P <.01), whereas mitral regurgitation increased from 0.3 +/- 0.2 to 2.2 +/- 0.9 (P <.0001). All annular segments dilated at end-diastole with tachycardia-induced cardiomyopathy, except the segment between the midseptal annulus and the left fibrous trigone. Annular segment contraction was significantly decreased with tachycardia-induced cardiomyopathy in the lateral, but not in the septal, regions. Three-dimensional reconstruction of annular shape revealed a saddle shape of the annulus at baseline; this shape was also measured with tachycardia-induced cardiomyopathy, but there was some flattening of the septal annulus. CONCLUSIONS: With tachycardia-induced cardiomyopathy, the mitral annulus dilated substantially, being more in the septal-lateral than in the commissure-commissure dimension. Greater annular segmental dilatation and decreased contraction occurred in the lateral annulus. The saddle shape of the annulus was retained but flattened.

Animals↗

Ablation of mitral annular and leaflet muscle: effects on annular and leaflet dynamics.

Mitral annular (MA) and leaflet three-dimensional (3-D) dynamics were examined after circumferential phenol ablation of the MA and anterior mitral leaflet (AML) muscle. Radiopaque markers were sutured to the left ventricle, MA, and both mitral leaflets in 18 sheep. In 10 sheep, phenol was applied circumferentially to the atrial surface of the mitral annulus and the hinge region of the AML, whereas 8 sheep served as controls. Animals were studied with biplane video fluoroscopy for computation of 3-D mitral annular area (MAA) and leaflet shape. MAA contraction (MAACont) was determined from maximum to minimum value. Presystolic MAA (PS-MAACont) reduction was calculated as the percentage of total reduction occurring before end diastole. Phenol ablation decreased PS-MAACont (72 +/- 6 vs. 47 +/- 31%, P = 0.04) and delayed valve closure (31 +/- 11 vs. 57 +/- 25 ms, P = 0.017). In control, the AML had a compound sigmoid shape; after phenol, this shape was entirely concave to the atrium during valve closure. These data indicate that myocardial fibers on the atrial side of the valve influence the 3-D dynamic geometry and shape of the MA and AML.

Animals↗

Annular versus subvalvular approaches to acute ischemic mitral regurgitation.

BACKGROUND: Ischemic mitral regurgitation (IMR) has been attributed to annular dilatation, papillary muscle (PM) displacement ("apical leaflet tenting"), or both. We compared the efficacy of reducing annular or subvalvular dimensions to gain more mechanistic insight into acute IMR. METHODS: Eight adult sheep underwent implantation of radiopaque markers on the LV, mitral annulus (MA), each leaflet edge, and each PM tip. Trans-annular septal-lateral (SL) and inter-PM tip sutures were placed and externalized. Biplane videofluoroscopy and transesophageal echocardiography were performed before and continuously during LCx occlusion-induced IMR with SL annular (SLAC) or inter-PM (PAPS) suture tightening (4 to 5 mm of cinching for 5 seconds during ischemia). MA SL dimension, inter-papillary distance (APM-PPM), and the distances between the anterior (APM) and posterior (PPM) PM tips and the mid-septal annulus ("saddle horn") were calculated from 3-D marker coordinates at end-systole. RESULTS: SLAC reduced IMR (grade=2.1+/-0.6 versus 0.7+/-0.5, P.001), SL annular diameter (4.9+/-2.5 mm smaller versus pre-cinching; P.001), and PM-"saddle horn" distances (0.9+/-0.7 and 1.0+/-0.8 mm reduction for APM and PPM, respectively; P.005). PAPS reduced APM-PPM distance (3.7+/-1.8 mm reduction versus precinching; P.001), only slightly decreased the PPM-"saddle horn" distance (0.3+/-0.3 mm reduction; P.03), and had no effect on IMR. CONCLUSIONS: Acute IMR was abolished by annular SL reduction, which also repositioned both PM tips closer to the mid-septal annulus and paradoxically increased leaflet "apical tenting"; reducing inter-papillary dimension was not effective, even though it displaced the leaflets toward the annular plane (less "apical tenting").

Acute Disease↗

Will a partial posterior annuloplasty ring prevent acute ischemic mitral regurgitation?

BACKGROUND: Acute posterolateral ischemia in sheep results in ischemic mitral regurgitation (IMR). While complete ring annuloplasty prevents acute IMR, partial annuloplasty rings may offer a more physiologic repair, but are untested in animal models of IMR. METHODS: Radiopaque markers were placed on the LV, mitral annulus (MA), and leaflets in 13 sheep. Seven sheep served as controls, and 6 had a St. Jude Tailor partial flexible ring implanted (29 mm in 5, 31 mm in 1). After 8+/-1 day, the animals were studied with biplane videofluoroscopy and echocardiography before and during acute posterolateral LV ischemia (balloon occlusion of circumflex artery). Mitral annular area (MAA), septal-lateral annular diameter (SL), annular perimeters, and leaflet edge separation were calculated from 3-D marker coordinates. RESULTS: The average degree of mitral regurgitation increased from 0.0+/-0.0 to 2.1+/-0.7 (P=0.0006) in the control group during acute ischemia but remained unchanged in the Tailor group (0.1+/-0.2 for both conditions). The change in MAA throughout the cardiac cycle before ischemia was 17+/-4% in control animals, but only 5+/-2% (P=0.0002) in the Tailor ring group. Unlike the control animals, there was no increase in MAA (5.4+/-0.8 and 5.5+/-0.7 cm(2), respectively; p=NS) nor dilatation of the muscular annulus (6.2+/-0.3 and 6.2+/-0.4, respectively; p=NS) during ischemia with the Tailor ring. Mitral SL dimension increased slightly with ischemia (2.3+/-0.2 versus 2.2+/-0.2 cm, P=0.03). Although posterior leaflet motion was limited, as observed with complete rings, normal annular flexion was maintained with the Tailor ring before and during acute ischemia. CONCLUSIONS: The Tailor partial annuloplasty ring prevented acute IMR probably by limiting SL diameter dilatation during acute ischemia. In this animal model of acute IMR, a partial, flexible posterior annuloplasty ring is as effective as a complete ring.

Acute Disease↗

Mechanistic insights into posterior mitral leaflet inter-scallop malcoaptation during acute ischemic mitral regurgitation.

BACKGROUND: Three-dimensional dynamics of the 3 individual scallops within the posterior mitral leaflet during acute ischemic mitral regurgitations have not been previously measured. METHODS: Radiopaque markers were sutured to the mitral annulus, papillary muscle tips, and leaflet edges in 13 sheep. Immediately postoperatively, under open-chest conditions, 3-D marker coordinates were obtained using high-speed biplane videofluoroscopy before and during echocardiographically verified acute ischemic mitral regurgitation produced by occlusion of the left circumflex coronary artery. RESULTS: During acute ischemic mitral regurgitation, at end systole, the anterolateral edge of the central scallop was displaced 0.8+/-0.9 mm laterally and 0.9+/-0.6 mm apically away from the anterolateral scallop; such displacement correlated with lateral displacement of the lateral annulus (R(2)=0.7, SEE=0.7 mm, P<0.001) and movement of the right lateral annulus away from the nonischemic anterior papillary tip (R(2)=0.6, SEE=0.8 mm, P=0.002), respectively. End-systolic displacement of the posteromedial edge of the central scallop was 1.4+/-0.9 mm anteriorly and 0.9+/-0.6 mm laterally away from the posteromedial scallop, corresponding to anterior displacement of the mid-lateral annulus (R(2)=0.5, SEE=1.0 mm, P<0.001). CONCLUSIONS: Malcoaptation of the scallops within the posterior leaflet during acute left ventricular ischemia is a novel observation. The primary geometric mechanism underlying scallop malcoaptation in acute ischemic mitral regurgitation was annular dilatation, which hindered leaflet coaptation by drawing the individual scallops apart. These findings support the use of annular reduction in the repair of ischemic mitral regurgitation and also suture closure of prominent subcommissures between posterior leaflet scallops.

Acute Disease↗

Does profound hypothermic circulatory arrest improve survival in patients with acute type a aortic dissection?

OBJECTIVE: No evidence exists that profound hypothermic circulatory arrest (PHCA) improves survival or reduces the likelihood of distal aortic reoperation in patients with acute type A aortic dissection. METHODS: Records of 307 patients with acute type A aortic dissection from 1967 to 1999 were retrospectively reviewed. The influence of repair using PHCA (n=121) versus without PHCA (n=186) on death and freedom from distal aortic reoperation was analyzed using multivariable Cox regression models. Propensity score analysis identified a subset of 152 comparable patients in 3 quintiles (QIII-V) in which the effects of PHCA (n=113) versus no PHCA (n=39) were further compared. RESULTS: For all patients, 30-day, 1-year, and 5-year survival estimates were 81+/-2%, 74+/-3%, and 63+/-3% (+/-1 SE). Survival rates and actual freedom from distal aortic reoperation was not significantly different between treatment methods in the entire patient cohort nor in the matched patients in quintiles III-V. Treatment method was not associated with differences in early major complications, late survival, or distal aortic reoperation rates in the entire patient sample or in quintiles III-V. CONCLUSIONS: Aortic repair with or without circulatory arrest was associated with comparable early complications, survival, and distal aortic reoperation rates in patients with acute type A aortic dissection. Despite the lack of concrete evidence favoring the use of PHCA, it does no harm, and most of our group uses PHCA regularly because of its practical technical advantages and theoretical potential merit.

Acute Disease↗

The effects of mitral annuloplasty rings on mitral valve complex 3-D geometry during acute left ventricular ischemia.

OBJECTIVE: Annuloplasty rings are used to treat ischemic mitral regurgitation (IMR), but their exact effects on 3-D geometry of the overall mitral valve complex during acute left ventricular (LV) ischemia remain unknown. METHODS: Radiopaque markers were sutured to the mitral leaflet edges, annulus, papillary muscle tips, and ventricle in three groups of sheep. One group served as control (n = 5), and the others underwent Duran (n = 6) or Physio (n = 5) ring annuloplasty. One week later, 3-D marker coordinates at end-systole were obtained before and during balloon occlusion of the circumflex artery. RESULTS: In all control animals, acute LV ischemia was associated with: (i) septal-lateral separation of the leaflet edges, which was predicted by lateral displacement of the lateral annulus during septal-lateral mitral annular dilatation; (ii) apical restriction of the posterior leaflet edge, which was predicted by displacement of the lateral annulus away from the non-ischemic anterior papillary muscle; (iii) displacement of the posterior papillary muscle, which was not predictive of either septal-lateral leaflet separation or leaflet restriction; and (iv) mitral regurgitation. In the Duran group during ischemia, the posterior leaflet edge shifted posteriorly due to posterior movement of the lateral annulus, but no IMR occurred. In the Physio group during ischemia, neither the posterior leaflet edge nor the lateral annulus changed positions, and there was no IMR. In both the Duran and Physio groups, displacement of the posterior papillary muscle did not lead to IMR. CONCLUSIONS: Either annuloplasty ring prevented the perturbations of mitral leaflet and annular--but not papillary muscle tip--3-D geometry during acute LV ischemia. By fixing the septal-lateral annular dimension and preventing lateral displacement of the lateral annulus, annuloplasty rings prevented systolic septal-lateral leaflet separation and posterior leaflet restriction, and no acute IMR occurred. The flexible ring allowed posterior displacement of the posterior leaflet edge and the lateral annulus, which was not observed with a semi-rigid ring.

Acute Disease↗

Septal-lateral annular cinching abolishes acute ischemic mitral regurgitation.

OBJECTIVE: Ring annuloplasty prevents acute ischemic mitral regurgitation in sheep, but it also abolishes normal mitral annular and posterior leaflet dynamics. We investigated a novel surgical approach of simple septal-lateral annular cinching with sutures to treat acute ischemic mitral regurgitation. METHODS: Nine adult sheep underwent implantation of multiple radiopaque markers on the left ventricle, mitral anulus, and mitral leaflets. A septal-lateral transannular suture was anchored to the midseptal mitral anulus and externalized to a tourniquet through the midlateral mitral anulus and left ventricular wall. Open-chest animals were studied immediately postoperatively. Acute ischemic mitral regurgitation was induced by means of proximal left circumflex artery snare occlusion, and 3 progressive steps of septal-lateral annular cinching (each 2-3 mm suture tightening for 5 seconds) were performed with the transannular suture. Biplane videofluoroscopy for 3-dimensional marker coordinates and transesophageal echocardiography were performed continuously before and during left circumflex ischemia and septal-lateral annular cinching. RESULTS: Acute left circumflex ischemia caused ischemic mitral regurgitation (+0.5 +/- 0.4 [baseline] vs +2.0 +/- 0.7 [ischemia]; P =.005; scale, +0-4), which decreased progressively with each step of septal-lateral annular cinching and was eliminated during the third step (ischemic mitral regurgitation, +0.6 +/- 0.5; P = not significant vs baseline). The third step of septal-lateral annular cinching decreased the septal-lateral diameter by 6.0 +/- 2.6 mm (P =.005); however, mitral anulus area reduction (8.5% +/- 1.0% and 6.9% +/- 1.9% for ischemic mitral regurgitation and septal-lateral annular cinching step 3, respectively; P =.006) and posterior leaflet excursion (50 degrees +/- 9 degrees and 44 degrees +/- 11 degrees for regurgitation and annular cinching step 3, respectively; P =.002) throughout the cardiac cycle were affected only mildly. Normal mitral annular 3-dimensional shape was maintained with septal-lateral annular cinching. CONCLUSIONS: Isolated 22% +/- 10% reduction in mitral annular septal-lateral dimension abolished acute ischemic mitral regurgitation in normal sheep hearts while allowing near-normal mitral annular and posterior leaflet dynamic motion. Septal-lateral annular cinching may represent a simple method for the surgical treatment of ischemic mitral regurgitation, either as an adjunctive technique or alone, which helps preserve physiologic annular and leaflet function.

Acute Disease↗

Is medical therapy still the optimal treatment strategy for patients with acute type B aortic dissections?

OBJECTIVE: The optimal treatment of patients with acute type B dissections continues to be debated. METHODS: A 36-year clinical experience of medical and surgical treatments in 189 patients was retrospectively analyzed (multivariable Cox proportional hazards model) with respect to three outcome end points: all deaths, freedom from reoperation, and freedom from late aortic complications or death. Propensity score analysis identified 2 quintiles (quintiles I and II, consisting of 142 comparable patients) for further comparison of the effects of surgical versus medical treatment. RESULTS: Shock (hazard ratio 14.5, 95% confidence interval 4.7-44.5, P <.001) and visceral ischemia (hazard ratio 10.9, 95% confidence interval 3.9-30.3, P <.001) largely predominated as determinants of death, along with 6 other risk factors (arch involvement, rupture, stroke, previous sternotomy, and coronary or lung disease), which roughly doubled the hazard of death. Female sex was a significant but weaker predictor of death. Renal dysfunction, year of presentation, age, and mode of therapy (medical vs surgical) had no important bearing on overall survival. The actuarial survival estimates for all patients were 71%, 60%, 35%, and 17% at 1, 5, 10, and 15 years, respectively, and were similar for the medical and surgical patients. Reoperation and late aortic complications were predicted by the presence of Marfan syndrome. For the propensity-matched patients in quintiles I and II, survival, freedom from reoperation, and freedom from aortic complications were almost identical in the medically treated and surgical subsets. CONCLUSIONS: The prognosis for patients with acute type B aortic dissection is bleak and determined primarily by dissection-related and patient-specific risk factors, which do not appear to be readily modifiable.

Acute Disease↗

Hemodynamic performance of an unstented xenograft mitral valve substitute.

OBJECTIVE: Stentless mitral xenografts offer potential clinical benefits because they mimic the normal bileaflet mitral valve. How best to implant them and their hemodynamic performance and durability, however, remain unknown. METHODS: A stentless porcine mitral xenograft valve (Medtronic physiologic mitral valve) was implanted in 7 sheep with papillary muscle sewing tubes attached with transmural left ventricular sutures. Radiopaque markers were inserted on the leaflets, annular cuff, papillary tips, and left ventricle. After 10 +/- 5 days, the animals were studied with biplane videofluoroscopy to determine 3-dimensional marker coordinates at baseline and during dobutamine infusion. Transesophageal echocardiography assessed mitral regurgitation and valvular gradients. Mitral annular area was calculated from the annular markers. Physiologic mitral valve leaflet and annular dynamics were compared with 8 native sheep valves. RESULTS: Average mitral regurgitation grade at baseline was 1.2 +/- 1.0 (range, 0-4), and the mean transvalvular pressure gradients were 3.6 +/- 1.3 and 6.2 +/- 2.2 mm Hg during baseline and dobutamine infusion, respectively. Xenograft mitral annular area contraction throughout the cardiac cycle was reduced (6% +/- 6% vs 13% +/- 4% for physiologic mitral valve and control valve, respectively; P =.03). Physiologic mitral valve leaflet geometry during closure differed from the native valve, with the anterior leaflet being convex to the atrium and with little motion of the posterior leaflet. Three animals survived more than 3 months; good healing of the annular cuff and papillary muscle tubes was demonstrated. CONCLUSION: This stentless xenograft mitral valve substitute had low gradients at baseline and during stress conditions early postoperatively, with mild mitral regurgitation. Preliminary analysis of healing characteristics appeared favorable at 3 months. Additional studies are needed to determine long-term xenograft mitral valve performance and resistance to calcification.

Animals↗