PubMed Health⌕ Search

Biomedical subjects

David W Berzins

Publications and source records attributed to David W Berzins.

7 recordsLinked to original sources

An in vitro comparison of the intraradicular dentin bond strength of Resilon and gutta-percha.

The purpose of this study was to compare the micropush-out bond strength of Resilon to that of gutta-percha. Extracted human anterior teeth were used for evaluation. The crowns were removed and the root canals were instrumented with Gates Glidden drills and 0.06 Profile rotary files. Instrumentation was performed with 5.25% sodium hypochlorite irrigation and a final rinse of 17% EDTA. The teeth were randomly divided into two groups. Gutta-percha group: obturation with gutta-percha and Kerr Pulp Canal Sealer EWT. Resilon group: obturation with Resilon points, Epiphany Primer, and Root Canal Sealant. The teeth were cut perpendicular to their long axis to obtain a series of 1.0 mm thick disks (n = 15 per group). Micropush-out bond strengths to root canal dentin were measured. The results show that the mean bond strength to root canal dentin was significantly higher (p < 0.05) in the Resilon/Epiphany group as compared to the gutta-percha/Kerr Pulp Canal Sealer EWT group.

Adhesiveness↗

A comparison of thermal properties between gutta-percha and a synthetic polymer based root canal filling material (Resilon).

A new polymer-based obturating material, Resilon, has been developed but there have been no studies identifying its thermal properties. The purpose of this study was to compare the melting point, specific heat, enthalpy change with melting and heat transfer between gutta-percha (GP) and Resilon (R). The first three tests were determined using a differential scanning calorimeter and the heat transfer test was determined using a split-tooth model. Results show no significant difference (t test, p > 0.05) between gutta-percha and Resilon for the melting point temperature (GP: 60.01 degrees C; R: 60.57 degrees C). There was a significant difference (t test, p < 0.05) in specific heat capacity (GP: 0.94 J/g degrees C, R: 1.15 J/g degrees C) and endothermic enthalpy change (GP: 10.88 J/g, R: 25.20 J/g) between the two materials. The heat transfer test showed a significant difference (Mann-Whitney, p < 0.05) in temperature increase between gutta-percha and Resilon within 3 mm of the heat source.

Calorimetry↗

Resistance to fracture of two all-ceramic crown materials following endodontic access.

STATEMENT OF PROBLEM: There is currently no protocol for managing endodontic access openings for all-ceramic crowns. A direct restorative material is generally used to repair the access opening, rendering a repaired crown as the definitive restoration. This endodontic procedure, however, may weaken the restoration or initiate microcracks that may propagate, resulting in premature failure of the restoration. PURPOSE: The purpose of this in vitro study was to evaluate how an endodontic access opening prepared through an all-ceramic crown altered the structural integrity of the ceramic, and the effect of a repair of this access on the load to failure of an all-ceramic crown. MATERIAL AND METHODS: Twenty-four alumina (Procera) and 24 zirconia (Procera) crowns were fabricated and cemented (Rely X Luting Plus Cement) onto duplicate epoxy resin dies. Twelve crowns of each were accessed to simulate root canal treatment therapy. Surface defects of all accessed specimens were evaluated with an environmental scanning electron microscope. The specimens were repaired with a porcelain repair system (standard adhesive resin/composite resin protocol) and were loaded to failure in a universal testing machine. Observations made visually and microscopically noted veneer delamination from the core, core fracture, shear within the veneer porcelain, or a combination thereof. A Kruskal-Wallis test was used to determine if a significant difference (alpha=.05) in load to failure existed between the 4 groups, and a Mann-Whitney test with a Bonferroni correction (P<.0125) was used for multiple comparisons. A Weibull analysis was also used to estimate the Weibull modulus and characteristic failure for each group. RESULTS: All specimens exhibited edge chipping around the access openings. Some displayed larger chips within the veneering porcelain, and 4 zirconia crowns showed radial crack formation. There was a significant difference in load to failure among all groups with the exception of the alumina intact and repaired specimens (P=.695). The alumina crowns generally showed fracture of the coping with the veneering porcelain still bonded to the core, whereas the zirconia copings tended not to fracture but experienced veneering porcelain delamination. CONCLUSION: Endodontic access through all-ceramic crowns resulted in a significant loss of strength in the zirconia specimens but not in the alumina specimens.

Aluminum Oxide↗

A comparison of bond strength between direct- and indirect-bonding methods.

The purpose of this study was to evaluate and compare the shear bond strength and the sites of bond failure for brackets bonded to teeth, using two indirect-bonding material protocols and a direct-bonding technique. Sixty extracted human premolars were collected and randomly divided into three groups. The direct-bonded group (group 1) used a light-cured adhesive and primer (Transbond XT). One indirect-bonded group (group 2) consisted of a chemical-cured primer (Sondhi Rapid Set) and light-cured adhesive (Transbond XT), whereas the other group (group 3) used a light-cured primer (Orthosolo) and adhesive (Enlight LV). Forty hours after bonding, the samples were debonded. Mean shear bond strengths were 16.27, 13.83, and 14.76 MPa for groups 1, 2, and 3, respectively. A one-way analysis of variance showed no significant difference in mean bond strength between groups (P = .21). Furthermore, a Weibull analysis showed all three groups tested provided over a 90% survival rate at normal masticatory and orthodontic force levels. For each tooth, an Adhesive Remnant Index (ARI) score was determined. Group 2 was found to have a significantly lower ARI score (P < .05) compared with groups 1 and 3. In addition, Pearson correlation coefficients indicated no strong correlation between bond strength and ARI score within or across all groups.

Analysis of Variance↗

Bond strength of direct and indirect bonded brackets after thermocycling.

Thermocycling simulates the temperature dynamics in the oral environment. With direct bonding, thermocycling reduces the bond strength of orthodontic adhesives to tooth structure. The purpose of this study was to evaluate the shear bond strengths (SBS) of one direct and two indirect bonding methods/adhesives after thermocycling. Sixty human premolars were divided into three groups. Teeth in group 1 were bonded directly with Transbond XT. Teeth in group 2 were indirect bonded with Transbond XT/Sondhi Rapid Set, which is chemically cured. Teeth in group 3 were indirect bonded with Enlight LV/Orthosolo and light cured. Each sample was thermocycled between 5 degrees C and 55 degrees C for 500 cycles. Mean SBS in groups 1, 2, and 3 were not statistically significantly different (13.6 +/- 2.9, 12.3 +/- 3.0, and 11.6 +/- 3.2 MPa, respectively; P > .05). However, when these values were compared with the results of a previous study using the same protocol, but without thermocycling, the SBS was reduced significantly (P = .001). Weibull analysis further showed that group 3 had the lowest bonding survival rate at the minimum clinically acceptable bond-strength range. The Adhesive Remnant Index was also determined, and group 2 had a significantly (P < .05) higher percentage of bond failures at the resin/enamel interface.

Bicuspid↗

Accuracy of LED and halogen radiometers using different light sources.

PURPOSE: To determine the accuracy of commercially available, handheld light-emitting diode (LED) and halogen-based radiometers using LED and quartz-tungsten-halogen (QTH) curing lights with light guides of various diameters. METHODS: The irradiance of an LED curing light (L.E. Demetron 1, SDS/Kerr, Orange, CA, USA) and a QTH curing light (Optilux 501, SDS/Kerr) were measured using multiple units of an LED (Demetron L.E.D. Radiometer, SDS/Kerr) and a halogen radiometer (Demetron 100, SDS/Kerr) and compared with each other and to a laboratory-grade power meter (control). Measurements were made using five light guides with distal light guide diameters of 4, 7, 8, 10, and 12.5 mm. For each light guide, five readings were made with each of three radiometers of each radiometer type. Data were analyzed with two-way analysis of variance/Tukey; alpha = 0.05. RESULTS: In general, both handheld radiometer types exhibited significantly different irradiance readings compared with the control meter. Additionally, readings between radiometer types were found to differ slightly, but were correlated. In general, the LED radiometer provided slightly lower irradiance readings than the halogen radiometer, irrespective of light source. With both types of handheld radiometers, the use of the larger-diameter light guides tended to overestimate the irradiance values as seen in the control, while smaller-diameter light guides tended to underestimate. CLINICAL SIGNIFICANCE: The evaluated LED or halogen handheld radiometers may be used interchangeably to determine the irradiance of both LED and QTH visible-light-curing units. Measured differences between the two radiometer types were small and probably not clinically significant. However, the diameter of light guides may affect the accuracy of the radiometers, with larger-diameter light guides overestimating and smaller-diameter guides underestimating the irradiance value measured by the control instrument.

Analysis of Variance↗

A bayesian approach to parameter estimation for a crayfish (Procambarus spp.) bioaccumulation model.

Bioaccumulation models are used to describe chemical uptake and clearances by organisms. Averaged input parameter values are traditionally used and yield point estimates of model outputs. Hence, the uncertainty and variability of model predictions are ignored. Probabilistic modeling approaches, such as Monte Carlo simulation and the Bayesian method, have been recommended by the U.S. Environmental Protection Agency to provide a quantitative description of the degree of uncertainty and/or variability in risk estimates in ecological hazards and human health effects. In this study, a Bayesian analysis was conducted to account for the combined uncertainty and variability of model parameters in a crayfish bioaccumulation model. After a 5-d exposure in the LaBranche Wetlands (LA, USA), crayfish were analyzed for polycyclic aromatic hydrocarbon concentrations and lipid fractions. The posterior distribution of model parameters were derived from the joint posterior parameter distributions using a Markov chain Monte Carlo approach and the experimental data. The results were then used to predict the distribution of chrysene concentration versus time in the crayfish to compare the predicted ranges at the different study sites.

Animals↗