PubMed Health⌕ Search

Biomedical subjects

David W Carmichael

Publications and source records attributed to David W Carmichael.

3 recordsLinked to original sources

Improving whole brain structural MRI at 4.7 Tesla using 4 irregularly shaped receiver coils.

Both higher magnetic field strengths (> or =3 T) and multiple receiver "array coils" can provide increased signal-to-noise ratio (SNR) for MRI. This increase in SNR can be used to obtain images with higher resolution, enabling better visualisation of structures within the human brain. However, high field strength systems also suffer from increased B(1) non-uniformity and increased power deposition, reaching specific absorption rate (SAR) limits more quickly. For these problems to be mitigated, a careful choice of both the pulse sequence design and transmit RF coil is required. This paper describes the use of a prototype array coil consisting of 4 irregularly shaped coils within a standard configuration for neuroimaging at 4.7 T (a head transmit/receive volume coil to minimise SAR and a head gradient insert for maximum gradient performance). With a fast spin echo (FSE) pulse sequence optimised for 4.7 T, this provides dramatically increased quality and resolution over a large brain volume. Using the array coil, a SNR improvement relative to the volume coil of 1-1.5 times in central brain areas and 2-3 times in cortical regions was obtained. Array coil images with a resolution of 352 x 352 x 2000 mum had a SNR of 16.0 to 26.2 in central regions and 19.9 to 34.8 in cortical areas. Such images easily demonstrate cortical myeloarchitecture, while still covering most of the brain in a approximately 12 min scan.

Algorithms↗

Common SENSE (sensitivity encoding using hardware common to all MR scanners): a new method for single-shot segmented echo planar imaging.

A new method is presented that enables image acquisition to be segmented into two readouts. This is achieved using a new pulse sequence that creates two components of magnetization with different spatial profiles. Each component of the magnetization is measured in one of the readouts. This produces two images with complimentary "sensitivity profiles" and near identical contrast. The images can be acquired with a reduced data matrix that corresponds to shorter periods of data acquisition. The reduced matrix images are then combined to produce a full matrix image using reconstruction methods previously applied to images from multiple RF coils in the sensitivity encoding (SENSE) technique. The most promising application for this technique is in improving the performance of echo planar imaging (EPI) at high field. In this application, common SENSE obtains two segments of data in a single excitation of the magnetization (i.e., two readouts are performed per shot). The combination of these segments in image space avoids the difficulties normally associated with segmented EPI methods, namely, increased ghosting from discontinuities in the k-space data. The main advantages are a reduction in distortion and blurring. Common SENSE is compatible with parallel imaging and partial Fourier methods.

Echo-Planar Imaging↗

Method for spatially interleaving two images to halve EPI readout times: two reduced acquisitions interleaved (TRAIL).

A new MRI method is presented that can generate images using half the normal readout time or, more usefully, half the number of phase-encode steps, combining two readouts per excitation. However, the corresponding data are interleaved in image space-not in k-space, as in many other fast techniques. This gives a resilience to the phase-related artifacts that can occur in many other techniques due to subject motion. A modified stimulated-echo experiment is used to create two low-resolution images from a single sequence. The magnetization that contributes to these images is nonuniformly distributed within each pixel, forming two sinusoidal waves in quadrature, with an oscillation period of exactly two pixels. Since only half of each pixel contributes significant signal, the two images can be interleaved to create a full image with twice as many pixels and double the resolution. When the technique is used in the phase-encode direction, the effective imaging time is halved, though with two readouts per TR period. When two half-length echo-planar readouts are used, the method can also reduce blurring and distortion by halving the effective readout time for echo-planar imaging (EPI). For even further improvements, the technique can be combined with partial Fourier or parallel imaging.

Echo-Planar Imaging↗