David W Holdsworth

Publications and source records attributed to David W Holdsworth.

At least 19 recordsLinked to original sources

Fast retrospectively gated quantitative four-dimensional (4D) cardiac micro computed tomography imaging of free-breathing mice.

OBJECTIVE: We sought to demonstrate retrospectively gated dynamic 3D cardiac micro computed tomography (CT) of free-breathing mice. MATERIALS AND METHODS: Five C57Bl6 mice were scanned using a cone-beam scanner with a slip-ring-mounted flat-panel detector. After the injection of an intravascular iodinated contrast agent, projection images were acquired over the course of 50 seconds, while the scanner rotated through 10 complete rotations. The mouse respiratory and electrocardiogram signals were recorder simultaneously with image acquisition. After acquisition, the projection images were retrospectively sorted into projections belonging to different cardiac time points, occurring only during expiration. RESULTS: Dynamic 3D cardiac images, with isotropic 150-microm voxel spacing, were reconstructed at 12-millisecond intervals throughout the cardiac cycle in all mice. The average ejection fraction and cardiac output were 58.2+/-4.6% and 11.4+/-1.3 mL/min, respectively. The measured entrance dose for the entire scan was 28 cGy. Repeat scans of the same animals showed that intrasubject variability was smaller than intersubject variability. CONCLUSIONS: We have developed a high-resolution micro computed tomography method for evaluating the cardiac function and morphology of free-breathing mice in acquisition times shorter than 1 minute.

Animals↗

Adventitial microvessel formation after coronary stenting and the effects of SU11218, a tyrosine kinase inhibitor.

OBJECTIVES: The aim of this study was to delineate the temporal profile of adventitial microvessel (Ad-MV) formation after stenting, its relationship to arterial wall hypoxia, and the effects of a tyrosine kinase inhibitor (TKI), SU11218, on Ad-MV and in-stent intimal hyperplasia (IH). BACKGROUND: Adventitial microvessels have been reported after arterial injury; however, the underlying stimulus for this response and its relationship to IH is unknown. METHODS: Coronary stenting was performed in 40 pigs randomized to SU11218 (n = 20) or placebo (n = 20). Vessel wall hypoxia was assessed by pimonidazole adducts and hypoxia-inducible factor (HIF)-1 alpha expression. Adventitial microvessels were quantified by three-dimensional microscopic computed tomography (3D micro CT). Intimal hyperplasia was measured by intravascular ultrasound (IVUS), 3D micro CT, and morphometry. The effects of SU11218 were assessed in vitro on smooth muscle cell (SMC) and endothelial cell (EC) functions and in vivo on Ad-MV and IH. RESULTS: Hypoxia was evident in the vessel wall at 48 h and persisted for four weeks. Adventitial microvessels increased significantly at one week (24 +/- 7 microvessels/segment) and four weeks (23 +/- 7 microvessels/segment) compared with uninjured arteries (16 +/- 2 microvessels/segment; p < 0.001) and correlated with IH (r = 0.77, p < 0.001). The TKI SU11218 inhibited platelet-derived growth factor receptor-beta phosphorylation, EC and SMC DNA synthesis, and migration in a dose-dependent manner in vitro and significantly inhibited Ad-MV (16 +/- 5 vs. 23 +/- 7 microvessels/segment in placebo, p < 0.001) and produced approximately 80% reduction in IH (0.52 +/- 0.51 mm2 vs. 2.47 +/- 1.66 mm2 in placebo, p < 0.001) at four weeks in vivo. CONCLUSIONS: Arterial stenting causes arterial wall hypoxia followed by Ad-MV formation. The TKI SU11218 inhibits both Ad-MV formation and IH and represents a promising therapeutic agent to prevent in-stent restenosis.

Animals↗

Time-course characterization of the computed tomography contrast enhancement of an iodinated blood-pool contrast agent in mice using a volumetric flat-panel equipped computed tomography scanner.

OBJECTIVE: The objective of this study was to determine the time-course of computed tomography (CT) contrast enhancement of an iodinated blood-pool contrast agent. METHODS: Five C57BL/6 mice were anesthetized, imaged at baseline, and given an iodinated blood-pool contrast agent. Micro-CT scans were acquired at 0, 0.25, 0.5, 1, 2, 4, 8, and 24 hours after injection. The mean CT number was determined in a region of interest in 7 organs. RESULTS: The CT contrast enhancement was plotted as a function of time for each organ. We identified an imaging window immediately after injection suitable for visualizing the vascular system and a second imaging window at 24 hours for visualizing liver and spleen. CONCLUSIONS: A single injection of the blood-pool contrast agent can be used for dual-phase investigations of the vasculature (t = 0 hours) and liver (t = 24 hours), which can be applied to studies of liver tumors or disease.

Animals↗

Angle-independent measure of motion for image-based gating in 3D coronary angiography.

The role of three-dimensional (3D) image guidance for interventional procedures and minimally invasive surgeries is increasing for the treatment of vascular disease. Currently, most interventional procedures are guided by two-dimensional x-ray angiography, but computed rotational angiography has the potential to provide 3D geometric information about the coronary arteries. The creation of 3D angiographic images of the coronary arteries requires synchronization of data acquisition with respect to the cardiac cycle, in order to minimize motion artifacts. This can be achieved by inferring the extent of motion from a patient's electrocardiogram (ECG) signal. However, a direct measurement of motion (from the 2D angiograms) has the potential to improve the 3D angiographic images by ensuring that only projections acquired during periods of minimal motion are included in the reconstruction. This paper presents an image-based metric for measuring the extent of motion in 2D x-ray angiographic images. Adaptive histogram equalization was applied to projection images to increase the sharpness of coronary arteries and the superior-inferior component of the weighted centroid (SIC) was measured. The SIC constitutes an image-based metric that can be used to track vessel motion, independent of apparent motion induced by the rotational acquisition. To evaluate the technique, six consecutive patients scheduled for routine coronary angiography procedures were studied. We compared the end of the SIC rest period (rho) to R-waves (R) detected in the patient's ECG and found a mean difference of 14 +/- 80 ms. Two simultaneous angular positions were acquired and rho was detected for each position. There was no statistically significant difference (P = 0.79) between rho in the two simultaneously acquired angular positions. Thus we have shown the SIC to be independent of view angle, which is critical for rotational angiography. A preliminary image-based gating strategy that employed the SIC was compared to an ECG-based gating strategy in a porcine model. The image-based gating strategy selected 61 projection images, compared to 45 selected by the ECG-gating strategy. Qualitative comparison revealed that although both the SIC-based and ECG-gated reconstructions decreased motion artifact compared to reconstruction with no gating, the SIC-based gating technique increased the conspicuity of smaller vessels when compared to ECG gating in maximum intensity projections of the reconstructions and increased the sharpness of a vessel cross section in multi-planar reformats of the reconstruction.

Algorithms↗

Characterization of volumetric flow rate waveforms in the normal internal carotid and vertebral arteries.

Knowledge of normal cerebrovascular volumetric flow rate (VFR) dynamics is of interest for establishing baselines, and for providing input data to cerebrovascular model studies. Retrospectively gated phase contrast magnetic resonance imaging was used to measure time-resolved VFR waveforms from the two internal carotid arteries (ICA) and two vertebral arteries (VA) of 17 young, normal volunteers (16M:1F) at rest in a supine posture. After normalizing each waveform to its respective cycle-averaged VFR, the timing and amplitude of feature points from the individual waveforms were averaged together to produce archetypal ICA and VA waveform shapes. Despite significant inter-individual differences in cycle-averaged VFR within the ICA compared to VA (275+/-52 versus 91+/-18 mL min-1), the respective waveform shapes were qualitatively similar overall. The VA waveform shape did, however, exhibit significantly higher amplitudes (e.g., peak:average VFR of 1.78+/-0.30 versus 1.66+/-0.16; p<0.05) and significantly higher variability both between and within subjects. A significant correlation was observed between peak and cycle-averaged VFR, suggesting that the representative waveform shapes presented here-when scaled by an individual's cycle-averaged VFR-may be used to characterize normal ICA and VA flow rate dynamics. This capability may be of particular utility for studies where cerebrovascular flow dynamics are required, but only average flow rates are available.

Adult↗

Multisite trial of MR flow measurement: phantom and protocol design.

PURPOSE: To describe a portable, easily assembled phantom with well-defined bore geometry together with a series of tests that will form the basis of a standardized quality assurance protocol in a multicenter trial of flow measurement by the MR phase mapping technique. MATERIALS AND METHODS: The phantom consists of silicone polymer layers containing parallel straight and stenosed flow channels in one layer and a U-bend in a second layer, separated by hermetically sealed agarose slabs. The phantom is constructed by casting low melting-point metal in an aluminum mold precisely milled to the desired geometry, and then using the low melting-point metal core as a negative around which the silicone is allowed to set. By melting out the metal, the flow channels are established. The milled aluminum mold is reusable, ensuring faithful reproduction of the flow geometry for all phantoms thus produced. The agarose layers provide additional loading and static background signal for background correction. With the use of the described phantom, one can evaluate flow measurement accuracy and repeatability, as well as the influence of several imaging geometry factors: slice offset, in-plane position, and slice-flow obliquity. RESULTS: The new phantom is compact and portable, and is well suited for reassembly. We were able to demonstrate its facility in a battery of tests of interest in evaluating MR flow measurements. CONCLUSION: The phantom is a robust standardized test object for use in a multicenter trial. Such a trial, to investigate the performance of MR flow measurement using the phantom and the tests we describe, has been initiated.

Blood Flow Velocity↗

Validation of a 40 MHz B-scan ultrasound biomicroscope for the evaluation of osteoarthritis lesions in an animal model.

OBJECTIVE: To evaluate high frequency (40 MHz) B-mode ultrasound for the detection of osteoarthritis (OA) lesions of varying severity in an animal model of OA. DESIGN: Ultrasound biomicroscopy (UBM) was performed on the femoral articular surface of adult rabbits with unilateral transection of the anterior cruciate ligament at 4, 8 and 12 weeks post-surgery and on control rabbits. The articular cartilage was examined and graded macroscopically and histologically for OA lesions. Histological examination was used as a reference to determine sensitivity and specificity of ultrasonographic and macroscopic examination regarding fibrillation and ulceration of articular cartilage. RESULTS: Identification of slight surface irregularities was made possible with UBM. The sensitivity and specificity of UBM were 92.3% and 96.4%, respectively, to detect histological fibrillation and 90.9% and 97.6%, respectively, to identify histological ulceration. Macroscopic examination using India Ink had a sensitivity and specificity of 80% and 96.4%, respectively, for fibrillation and 90.9% and 90.5%, respectively, for ulceration when compared to histology. A high correlation (rsp=0.90) was found between ultrasonographic and histological scores. CONCLUSIONS: UBM of articular cartilage reflects histological structure and can accurately detect early changes such as fibrillation. UBM has the potential to be a valuable tool for the in vivo identification of early lesions of OA and for monitoring the disease or efficacy of novel therapy if it can be packaged in a minimally invasive format suitable for intra-articular imaging.

Animals↗

Real-time numerical simulation of Doppler ultrasound in the presence of nonaxial flow.

Numerical simulations of Doppler ultrasound (DUS) relying on computational fluid dynamics (CFD) models of nonaxial flow have traditionally employed detailed (but computationally intensive) models of the DUS physics, or have sacrificed much of the physics in the interest of computational or conceptual simplicity. In this paper, we present a compromise between these extremes, with the objective of simulating the essential characteristics of DUS spectrograms in a real-time manner. Specifically, a precomputed pulsatile CFD velocity field is interrogated at some number, N, of discrete points distributed spatially within a sample volume of prescribed geometry and power distribution and temporally within a prescribed sampling window. Intrinsic spectral broadening is accounted for by convolving each of the point velocities with a semiempirical broadening function. Real-time performance is facilitated through the use of an efficient algorithm for interpolating the unstructured CFD data. A spherical sample volume with Gaussian power distribution, N = 1000 sampling points, and quadratic broadening function are shown to be adequate for simulating, at frame rates of 86 Hz on a 1.5 GHz desktop workstation, realistic-looking spectrograms at representative locations within a stenosed carotid bifurcation model. Via qualitative comparisons with matched in vitro data, these simulated spectrograms are shown to mimic the distinctive spectral envelopes, broadening and power characteristics associated with common carotid, stenotic jet and poststenotic recirculating flows. We conclude that the complex interaction between Doppler ultrasound and complicated clinically relevant blood flow dynamics can be simulated in real time via this relatively straightforward semiempirical approach.

Algorithms↗

Computed tomographic analysis of bone support for three acetabular cup designs.

The initial stability and long-term survivorship of cementless acetabular components is partially dependent on bone-prosthesis contact patterns. This study addresses the question: What are the differences in contact patterns for hemispheric, dual geometry, and spiked designs? Quantitative and qualitative assessment of contact patterns was achieved using a novel, nondestructive computed tomography-based analysis. Eighteen cadaveric hemipelvis specimens were randomly assigned to receive one of three cup designs. The mean amount of cup contact was 48.6% in the hemisphere group, 31.9% in the dual geometry group, and 35.1 percent in the spiked group. The hemispheric design showed more contact and a more uniform contact pattern than the dual geometry design. The dual geometry design featured a tight fit at the rim of the implant. In the spiked group, the amount of bone-prosthesis contact was affected by the distance that the spikes advanced into the pelvic bone. This nondestructive imaging technique has potential future uses in in vitro and in vivo studies.

Acetabulum↗

Virtual angiography for visualization and validation of computational models of aneurysm hemodynamics.

It has recently become possible to simulate aneurysmal blood flow dynamics in a patient-specific manner via the coupling of three-dimensional (3-D) X-ray angiography and cmputational fluid dynamics (CFD). Before such image-based CFD models can be used in a predictive capacity, however, it must be shown that they indeed reproduce the in vivo hemodynamic environment. Motivated by the fact that there are currently no techniques for adequately measuring complex blood velocity fields in vivo, in this paper we describe how cine X-ray angiograms may be simulated for the purpose of indirectly validating patient-sperific CFD models. Mimicking the radiological procedure, a virtual angiogram is constructed by first simulating the time-varying injection of contrast agent into a precomputed, patient-specific CFD model. A time-series of images is then constructed by simulating the attenuation of X-rays through the computed 3-D contrast-agent flow dynamics. Virtual angiographic images and residence time maps, here derived from an image-based CFD model of a giant aneurysm, are shown to be in excellent agreement wiith the corresponding clinical images and residence time maps, but only when the interaction between the quasisteady contrast agent injection and the pulsatile flow are properly accounted for. These virtual angiographic techniques pave the way for validating image-based CFD models against routinely available clinical data, and provide a means of visualizing complex, 3-D blood flow dynamics in a clinically relevant manner. They also clearly show how the contrast agent injection perturbs the noraml blood flow patterns, further highlighting the potential utility of image-based CFD as a window into the true aneurysmal hemodynamics.

Algorithms↗

Correction of XRII geometric distortion using a liquid-filled grid and image subtraction.

X-ray image intensifier (XRII) geometric distortion reduces the accuracy of image-guided procedures and quantitative image reconstructions. Due to the dependence of this error on the earth's magnetic field, the required correction is angle dependent, and calibration data should ideally be acquired simultaneously with clinical image data, at a specific orientation. We describe a technique to correct XRII geometric image distortion at any angular position during a stereotactic procedure. This approach uses a machined plastic grid, which contains channels that can be filled with iodinated contrast agent and subsequently flushed with water, providing contrast and mask images, respectively, of a geometric calibration grid. The standard image subtraction capabilities of conventional digital subtraction angiography devices can then be used to create a subtraction image of the iodine-filled channels, without any confounding anatomical structure. Grid-line intersection points are used to determine the control points that are required for a global polynomial correction algorithm, creating a correction map that is specific to the current angular position and XRII field of view (FOV). Tests with a clinical C-arm based XRII show that control points can be obtained with a precision of +/-0.053 mm, resulting in geometric correction accuracy of +/-0.152 mm, at a nominal FOV of 40 cm. While the precision and accuracy are both poorer than that achieved with a high-contrast steel-bead grid, the fact that the liquid grid can remain rigidly attached to the XRII during an entire procedure results in the establishment of an absolute detector coordinate system (referenced to the liquid-filled correction grid). The design of the liquid-filled channels allows the required control points to be introduced into the image or removed in about 30 s, avoiding the appearance of obscuring or confounding markers during clinical image acquisition, with a concurrent increase in patient dose of about 8% in the current design. Applications for this technique include stereotactic surgery, radiosurgery, x-ray stereogrammetry, and other image-guided procedures.

Algorithms↗

Prospective respiratory-gated micro-CT of free breathing rodents.

Microcomputed tomography (Micro-CT) has the potential to noninvasively image the structure of organs in rodent models with high spatial resolution and relatively short image acquisition times. However, motion artifacts associated with the normal respiratory motion of the animal may arise when imaging the abdomen or thorax. To reduce these artifacts and the accompanying loss of spatial resolution, we propose a prospective respiratory gating technique for use with anaesthetized, free-breathing rodents. A custom-made bed with an embedded pressure chamber was connected to a pressure transducer. Anaesthetized animals were placed in the prone position on the bed with their abdomens located over the chamber. During inspiration, the motion of the diaphragm caused an increase in the chamber pressure, which was converted into a voltage signal by the transducer. An output voltage was used to trigger image acquisition at any desired time point in the respiratory cycle. Digital radiographic images were acquired of anaesthetized, free-breathing rats with a digital radiographic system to correlate the respiratory wave form with respiration-induced organ motion. The respiratory wave form was monitored and recorded simultaneously with the x-ray radiation pulses, and an imaging window was defined, beginning at end expiration. Phantom experiments were performed to verify that the respiratory gating apparatus was triggering the micro-CT system. Attached to the distensible phantom were 100 microm diameter copper wires and the measured full width at half maximum was used to assess differences in image quality between respiratory-gated and ungated imaging protocols. This experiment allowed us to quantify the improvement in the spatial resolution, and the reduction of motion artifacts caused by moving structures, in the images resulting from respiratory-gated image acquisitions. The measured wire diameters were 0.135 mm for the stationary phantom image, 0.137 mm for the image gated at end deflation, 0.213 mm for the image gated at peak inflation, and 0.406 mm for the ungated image. Micro-CT images of anaesthetized, free-breathing rats were acquired with a General Electric Healthcare eXplore RS in vivo micro-CT system. Images of the thorax were acquired using the respiratory cycle-based trigger for the respiratory-gated mode. Respiratory gated-images were acquired at inspiration and end expiration, during a period of minimal respiration-induced organ motion. Gated images were acquired with a nominal isotropic voxel spacing of 44 microm in 20-25 min (80 kVp, 113 mAs, 300 ms imaging window per projection). The equivalent ungated acquisitions were 11 min in length. We observed improved definition of the diaphragm boundary and increased conspicuity of small structures within the lungs in the gated images, when compared to the ungated acquisitions. In this work, we have characterized the externally monitored respiratory wave form of free-breathing, anaesthetized rats and correlated the respiration-induced organ motion to the respiratory cycle. We have shown that the respiratory pressure wave form is an excellent surrogate for the radiographic organ motion. This information facilitates the definition of an imaging window at any phase of the breathing cycle. This approach for prospectively gated micro-CT can provide high quality images of anaesthetized free-breathing rodents.

Animals↗

Internal carotid artery stenosis measurement: comparison of 3D computed rotational angiography and conventional digital subtraction angiography.

BACKGROUND AND PURPOSE: Clinical trials have shown that carotid endarterectomy reduces stroke risk in symptomatic individuals with severe internal carotid artery (ICA) stenosis. As a result of these trials, digital subtraction angiography (DSA) became a standard of reference for ICA stenosis diagnosis. Newer 3D techniques provide a larger number of views than DSA, which may influence the estimated degree of stenosis. We evaluate this possibility by directly comparing stenosis grades from 3D computed rotational angiography (CRA) and DSA. METHODS: As a prospective diagnostic study, we performed CRA and DSA on 26 consecutive symptomatic patients. Only 1 angiographic procedure was performed on normal asymptomatic arteries, yielding 42 arteries for comparison. Four neuroradiologists graded the CRA maximum intensity projections (MIPs) and DSA images, according to the North American Symptomatic Carotid Endarterectomy Trial guidelines. CRA studies included a search for the narrowest view by evaluating 60 MIPs generated at 3 degrees intervals and measurement of actual artery diameters. Artery diameters and stenosis grades were analyzed graphically; statistical significance was determined using a paired t test. RESULTS: The mean difference of 1.2% (CI, -18%, 21%) between CRA and DSA stenosis grades was not statistically significant (P=0.55). Agreement of the optimal CRA viewing angle was limited, with an interobserver variability of 24+/-13 degrees . The interobserver variability of DSA and CRA stenosis grades, 9.1% (CI, 0%, 21%) and 9.4% (CI, 0%, 22%), respectively, was not significantly different (P=0.79). CONCLUSIONS: CRA provides stenosis grades equivalent to DSA, as well as absolute measurements, providing a comparison for newer 3D techniques.

Aged↗

High-resolution MRI and micro-CT in an ex vivo rabbit anterior cruciate ligament transection model of osteoarthritis.

OBJECTIVE: The aim of this study was to investigate the potential of using non-invasive, multi-modality imaging techniques to quantify disease progression in a rabbit model of experimentally induced osteoarthritis (OA). METHODS: High-resolution 4-T magnetic resonance imaging (MRI) and micro-computed tomography (micro-CT) techniques were implemented and validated in an ex vivo rabbit anterior cruciate ligament transection (ACLT) model of OA. A three-dimensional (3-D) rigid body registration technique was executed and evaluated to allow combined MR-CT analysis in co-registered image volumes of the knee. RESULTS: The 3-D MRI and micro-CT data formats made it possible to quantify cartilage damage, joint-space, and osseous changes in the rabbit ACLT model of OA. Spoiled gradient-recalled echo and fast-spin echo (FSE) sequences were jointly used to evaluate femorotibial cartilage and determine the sensitivity (78.3%) and specificity (95.3%) of 4-T MRI to detect clinically significant cartilage lesions. Overall precision error of the micro-CT technique for analysis of joint-space, volumetric bone mineral density (vBMD), and bone volume fraction (BV/TV) was 1.8%, 1.2%, and 2.0%, respectively. Co-registration of the 3-D data sets was achieved to within 0.36 mm for completed intermodality registrations, 0.22 mm for extrapolated intramodality registrations, and 0.50mm for extrapolated intermodality registrations. CONCLUSIONS: These results indicate that high-resolution 4-T MRI and micro-CT can be used to accurately quantify cartilage damage and calcified tissue changes in the rabbit ACLT model of OA. In addition, image volumes can be successfully co-registered to facilitate a comprehensive multi-modality examination of localized changes in both soft tissue and bone within the rabbit femorotibial joint.

Animals↗

Ex vivo characterization of articular cartilage and bone lesions in a rabbit ACL transection model of osteoarthritis using MRI and micro-CT.

OBJECTIVE: To characterize the rabbit anterior cruciate ligament transection (ACLT) model of osteoarthritis (OA) at various stages of disease using high-resolution 3-D medical imaging systems, which, in turn, will facilitate future longitudinal studies evaluating disease progression and response to therapy in live animals. METHODS: Degenerative changes in femorotibial cartilage, volumetric bone mineral density (vBMD), bone volume fraction (BV/TV), and osteophyte volume were characterized ex vivo using 4-T magnetic resonance imaging (MRI) and micro-computed tomography (micro-CT) at 4, 8, and 12 weeks post-ACLT. These changes were subsequently correlated to macroscopic joint evaluation. RESULTS: Macroscopic assessment demonstrated progressive cartilage degeneration post-surgery, which was significantly correlated to MRI evaluation (r=0.82, P<0.0001). Linear regression analysis indicated that vBMD and BV/TV are linearly related such that as vBMD increases, BV/TV increases (P<0.0001). Micro-CT revealed bone loss at 4 and 8 weeks post-ACLT, but recovery to control values at 12 weeks post-ACLT. Volumetric BMD was not strongly correlated with macroscopic assessment of articular cartilage degeneration (r=-0.35, P<0.0001). Quantitative measurement of osteophyte volume demonstrated a statistically significant difference (with respect to control groups) at both 8 and 12 weeks post-ACLT, but not at 4 weeks post-ACLT. CONCLUSIONS: The rabbit ACLT model of OA demonstrates progressive cartilage degeneration and intermediate bone changes at 4, 8, and 12 weeks post-surgery. Cartilage and bone lesions were characterized ex vivo using 4-T MRI and micro-CT, and MRI assessment of cartilage degeneration was correlated to macroscopic grading.

Animals↗

A thin-walled carotid vessel phantom for Doppler ultrasound flow studies.

A technique is discussed for producing a robust ultrasound (US)-compatible flow phantom that consists of a thin-walled silicone-elastomer vessel with a lumen of arbitrary geometry, embedded in an agar-based tissue-mimicking material (TMM). The TMM has an acoustic attenuation of 0.56 dB cm(-1) MHz(-1) at 5 MHz, with nearly linear frequency-dependence and acoustic velocity of 1539 +/- 4 m s(-1). The vessel-mimicking material (VMM) has an acoustic attenuation of 3.5 dB cm(-1) MHz(-1) with linear frequency-dependence and an acoustic velocity of 1020 +/- 20 m s(-1). Scattering particles, which are added to the VMM to increase echogenicity and add speckle texture, lead to higher attenuation, depending on particle concentration and frequency. The VMM is stable over time, with a Young's elastic modulus of 1.3 to 1.7 MPa for strains of up to 10%, which mimics human arteries under typical physiological conditions. The phantom is sealed to prevent TMM exposure to air or water, to avoid changes to the acoustic velocity.

Carotid Arteries↗

Micro-computed tomography of a 500-year-old tooth: technical note.

OBJECTIVE: To determine whether micro-computed tomography (micro-CT) could be used to reconstruct ancient dental anatomy accurately and differentiate the enamel from the dentin, as well as to verify whether micro-CT could detect tooth disorders such as attrition or caries accurately. METHODS: Micro-CT imaging was performed, using a cone-beam micro-CT specimen scanner, on a 500-year-old human tooth found in a burial jar in the Cardomom Mountains in southwestern Cambodia. RESULTS: The occlusal surface of the tooth showed marked attrition, with the dentin extending close to the enamel layer on the crown. In addition to this, micro-CT images depicted calculus on the buccal surface and a cervical root caries lesion present on the distal surface. The sclerotic zone of the carious lesion (located deep in the destroyed dentin) and the dentin were effectively differentiated through excellent resolution and superior tissue contrast of the volume data set. Axial slices from apical to coronal show the carious lesion extending vertically along the dentin-enamel junction with an intact outer enamel surface. CONCLUSION: Micro-CT is a reproducible, nondestructive and highly accurate technique that can be successfully applied to the study of ancient teeth.

Cambodia↗

MP3 compression of Doppler ultrasound signals.

The effect of lossy, MP3 compression on spectral parameters derived from Doppler ultrasound (US) signals was investigated. Compression was tested on signals acquired from two sources: 1. phase quadrature and 2. stereo audio directional output. A total of 11, 10-s acquisitions of Doppler US signal were collected from each source at three sites in a flow phantom. Doppler signals were digitized at 44.1 kHz and compressed using four grades of MP3 compression (in kilobits per second, kbps; compression ratios in brackets): 1400 kbps (uncompressed), 128 kbps (11:1), 64 kbps (22:1) and 32 kbps (44:1). Doppler spectra were characterized by peak velocity, mean velocity, spectral width, integrated power and ratio of spectral power between negative and positive velocities. The results suggest that MP3 compression on digital Doppler US signals is feasible at 128 kbps, with a resulting 11:1 compression ratio, without compromising clinically relevant information. Higher compression ratios led to significant differences for both signal sources when compared with the uncompressed signals.

Algorithms↗