PubMed Health⌕ Search

Biomedical subjects

David W Schmidtke

Publications and source records attributed to David W Schmidtke.

8 recordsLinked to original sources

Micropatterned surfaces for controlling cell adhesion and rolling under flow.

Cell adhesion and rolling on the vascular wall is critical to both inflammation and thrombosis. In this study we demonstrate the feasibility of using microfluidic patterning for controlling cell adhesion and rolling under physiological flow conditions. By controlling the width of the lines (50-1000 microm) and the spacing between them (50-100 microm) we were able to fabricate surfaces with well-defined patterns of adhesion molecules. We demonstrate the versatility of this technique by patterning surfaces with 3 different adhesion molecules (P-selectin, E-selectin, and von Willebrand Factor) and controlling the adhesion and rolling of three different cell types (neutrophils, Chinese Hamster Ovary cells, and platelets). By varying the concentration of the incubating solution we could control the surface ligand density and hence the cell rolling velocity. Finally by patterning surfaces with both P-selectin and von Willebrand Factor we could control the rolling of both leukocytes and platelets simultaneously. The technique described in this paper provides and effective and inexpensive way to fabricate patterned surfaces for use in cell rolling assays under physiologic flow conditions.

Animals↗

Nanostructured biosensors built by layer-by-layer electrostatic assembly of enzyme-coated single-walled carbon nanotubes and redox polymers.

In this study, we describe the construction of glucose biosensors based on an electrostatic layer-by-layer (LBL) technique. Gold electrodes were initially functionalized with negatively charged 11-mercaptoundecanoic acid followed by alternate immersion in solutions of a positively charged redox polymer, poly[(vinylpyridine)Os(bipyridyl)2Cl(2+/3+)], and a negatively charged enzyme, glucose oxidase (GOX), or a GOX solution containing single-walled carbon nanotubes (SWNTs). The LBL assembly of the multilayer films were characterized by UV-vis spectroscopy, ellipsometry, and cyclic voltammetry, while characterization of the single-walled nanotubes was performed with transmission electron microscopy, Raman spectroscopy, thermogravimetric analysis, and X-ray photoelectron spectroscopy. When the GOX solution contained single-walled carbon nanotubes (GOX-SWNTs), the oxidation peak currents during cyclic voltammetry increased 1.4-4.0 times, as compared to films without SWNTs. Similarly the glucose electro-oxidation current also increased (6-17 times) when SWNTs were present. By varying the number of multilayers, the sensitivity of the sensors could be controlled.

Aspergillus niger↗

Synthesis of nanometer-scale polymeric structures on surfaces from template assisted admicellar polymerization: a comparative study with protein adsorption.

A novel method for the formation of nanometer-scale polymer structures via template assisted admicellar polymerization (TAAP) is described. Admicellar polymerization uses a surfactant layer adsorbed on a surface to localize monomer to the surface prior to polymerization of the monomer. Nanostructures are formed by restricting adsorption to the uncovered sites of an already-templated surface, in this case to the interstitial sites between adsorbed latex spheres. Unlike most other process that form polymer nanostructures, polymer dimensions can be significantly smaller than the interstitial size because of sphere-surfactant interactions. Protein adsorption in the interstitial sites of colloidal arrays was also studied for three different proteins, and the results were compared with those obtained via admicellar polymerization.

Adsorption↗

Amperometric biosensors based on redox polymer-carbon nanotube-enzyme composites.

Based on their size and unique electrical properties, carbon nanotubes offer the exciting possibility of developing ultrasensitive, electrochemical biosensors. In this study, we describe the construction of amperometric biosensors based on the incorporation of single-walled carbon nanotubes modified with enzyme into redox polymer hydrogels. The composite films were constructed by first incubating an enzyme in a single-walled carbon nanotube (SWNTs) solution and then cross-linking within a poly[(vinylpyridine)Os(bipyridyl)(2)Cl(2+/3+)] polymer film. Incorporation of SWNTs, modified with glucose oxidase, into the redox polymer films resulted in a 2-10-fold increase in the oxidation and reduction peak currents during cyclic voltammetry, while the glucose electrooxidation current was increased 3-fold to approximately 1 mA/cm(2) for glucose sensors. Similar effects were also observed when SWNTs were modified with horseradish peroxidase prior to incorporation into redox hydrogels.

Biosensing Techniques↗

Dynamic alterations of membrane tethers stabilize leukocyte rolling on P-selectin.

Leukocytes rolling on selectins extrude thin membrane tethers that might stabilize rolling velocities despite marked alterations in wall shear stress. To test this hypothesis, we used differential interference contrast videomicroscopy to visualize formation and breakage of membrane tethers as neutrophils rolled on P-selectin under flow. Neutrophils rapidly increased tether number as wall shear stress rose and decreased tether number as wall shear stress declined. Membrane tethers invariably accompanied slower, more uniform rolling steps that translated into lower mean rolling velocities and variances in velocity. Unexpectedly, neutrophils, but not fixed cells or microspheres bearing selectin ligands, rolled progressively more slowly and uniformly over time. Scanning electron microscopy revealed that neutrophils developed larger, more complex tether structures as they rolled for longer periods. These data provide evidence that neutrophils stabilize selectin-mediated rolling by rapidly adjusting tether number in response to changes in wall shear stress. Gradual remodeling of tether architecture may further reduce rolling velocities, facilitating integrin-dependent deceleration and arrest on inflamed vascular surfaces.

Animals↗

Selectin-like kinetics and biomechanics promote rapid platelet adhesion in flow: the GPIb(alpha)-vWF tether bond.

The ability of platelets to tether to and translocate on injured vascular endothelium relies on the interaction between the platelet glycoprotein receptor Ib alpha (GPIb(alpha)) and the A1 domain of von Willebrand factor (vWF-A1). To date, limited information exists on the kinetics that govern platelet interactions with vWF in hemodynamic flow. We now report that the GPIb(alpha)-vWF-A1 tether bond displays similar kinetic attributes as the selectins including: 1) the requirement for a critical level of hydrodynamic flow to initiate adhesion, 2) short-lived tethering events at sites of vascular injury in vivo, and 3) a fast intrinsic dissociation rate constant, k(0)(off) (3.45 +/- 0.37 s(-1)). Values for k(off), as determined by pause time analysis of transient capture/release events, were also found to vary exponentially (4.2 +/- 0.8 s(-1) to 7.3 +/- 0.4 s(-1)) as a function of the force applied to the bond (from 36 to 217 pN). The biological importance of rapid bond dissociation in platelet adhesion is demonstrated by kinetic characterization of the A1 domain mutation, I546V that is associated with type 2B von Willebrand disease (vWD), a bleeding disorder that is due to the spontaneous binding of plasma vWF to circulating platelets. This mutation resulted in a loss of the shear threshold phenomenon, a approximately sixfold reduction in k(off), but no significant alteration in the ability of the tether bond to resist shear-induced forces. Thus, flow dependent adhesion and rapid and force-dependent kinetic properties are the predominant features of the GPIb(alpha)-vWF-A1 tether bond that in part may explain the preferential binding of platelets to vWF at sites of vascular injury, the lack of spontaneous platelet aggregation in circulating blood, and a mechanism to limit thrombus formation.

Antibodies, Monoclonal↗

Comparison of PSGL-1 microbead and neutrophil rolling: microvillus elongation stabilizes P-selectin bond clusters.

A cell-scaled microbead system was used to analyze the force-dependent kinetics of P-selectin adhesive bonds independent of micromechanical properties of the neutrophil's surface microvilli, an elastic structure on which P-selectin ligand glycoprotein-1 (PSGL-1) is localized. Microvillus extension has been hypothesized in contributing to the dynamic range of leukocyte rolling observed in vivo during inflammatory processes. To evaluate PSGL-1/P-selectin bond kinetics of microbeads and neutrophils, rolling and tethering on P-selectin-coated substrates were compared in a parallel-plate flow chamber. The dissociation rates for PSGL-1 microbeads on P-selectin were briefer than those of neutrophils for any wall shear stress, and increased more rapidly with increasing flow. The microvillus length necessary to reconcile dissociation constants of PSGL-1 microbeads and neutrophils on P-selectin was 0.21 microm at 0.4 dyn/cm2, and increased to 1.58 microm at 2 dyn/cm2. The apparent elastic spring constant of the microvillus ranged from 1340 to 152 pN/microm at 0.4 and 2.0 dyn/cm2 wall shear stress. Scanning electron micrographs of neutrophils rolling on P-selectin confirmed the existence of micrometer-scaled tethers. Fixation of neutrophils to abrogate microvillus elasticity resulted in rolling behavior similar to PSGL-1 microbeads. Our results suggest that microvillus extension during transient PSGL-1/P-selectin bonding may enhance the robustness of neutrophil rolling interactions.

Antibodies, Monoclonal↗

Defining the period of recovery of the glucose concentration after its local perturbation by the implantation of a miniature sensor.

At the wound caused by implanting a subcutaneous glucose sensor, the concentration of glucose differs transiently from that in the subcutaneous fluid near non-wounded skin. The period of recovery differs for different wounds and is difficult to predict. A diabetic patient implanting a subcutaneous sensor needs to know whether the transient difference subsided sufficiently for the sensor readings and the sensor's in vivo calibration to be valid. The miniature amperometric glucose sensor has a compound membrane including a layer of glucose oxidase the reaction centers of which are electrically connected to the electrode through a redox polymer; layers excluding interferents and poisons of the electrocatalytic oxidation of glucose; and a layer reducing fouling by components of the biological fluids. We show that the sensor maintains its in vitro sensitivity after its implantation for four hours in the jugular vein and in the peritoneal fluid of the rat. For a diabetic patient who implants the sensor the four-hour period is long enough for the insertion-trauma-caused local perturbation of the glucose concentration to subside and to safely rely on the readings of the implanted sensor.

Animals↗