PubMed Health⌕ Search

Biomedical subjects

David Whitley

Publications and source records attributed to David Whitley.

7 recordsLinked to original sources

Specific occupant and collision characteristics are associated with motor vehicle collision-related blunt cerebrovascular artery injury.

BACKGROUND: Blunt cerebrovascular artery injury (BCI) remains difficult to diagnose but is recognized with increasing frequency after motor vehicle collisions (MVCs). Failure to detect this injury in a timely fashion can be devastating. Criteria that can be used to heighten the suspicion of this injury have been suggested; however, more encompassing screening has been recommended. To address this need, we sought to describe occupant, vehicle, and collision characteristics among MVC occupants who sustained a BCI. METHODS: All cases of BCI identified in the National Automotive Sampling System Crashworthiness Data System, a national probability sample of passenger vehicles involved in police-reported tow-away MVCs, between 1993 and 2001 were selected. Information on occupant (e.g., demographics, seating position, and restraint use), collision (e.g., collision type and severity), and vehicle characteristics were obtained and summarized using descriptive statistics. RESULTS: Nine-hundred forty individuals with BCI were identified in the Crashworthiness Data System data files. Over half were belted (57.4%) and 82.3% had airbag deployment; 16.2% were partially or completely ejected from the vehicle. Head and thoracic injuries were common (44.4% and 40.8%, respectively); 27.8% sustained a cervical spine fracture and 21.0% sustained a soft-tissue injury to the neck. The mean Injury Severity Score was 33.6. The case fatality rate was 44.5%. The majority of BCI occupants were drivers (76.0%). Among belted occupants, the lap/shoulder was the most commonly attributed as the injury source (61.4%). Among unbelted occupants, frequent injury sources included air bags (15.0%), windshield (13.7%), and other interior objects. With respect to collision characteristics, the average change in velocity (Delta V) was 43.3 km/h. The majority of collisions were frontal (76.2%). CONCLUSION: This study indicates that BCI is both a rare and lethal injury typified by specific occupant and collision characteristics. These characteristics provide insight as to the cause of this injury that may aid in the evaluation and management of the blunt trauma patient at risk for BCI.

Accidents, Traffic↗

Determining patient preference for treatment of extracranial carotid artery stenosis: carotid angioplasty and stenting versus carotid endarterectomy.

Revascularization of extracranial carotid artery stenosis (ECAS) continues to be the subject of spirited academic debate. Conflicting studies in the literature have fostered uncertainty among patients choosing between CEA and CAS. We obtained preference-based utilities from prospective patients being evaluated for ECAS and incorporated them into a decision analytic model. Patients being evaluated for ECAS in an outpatient setting were interviewed prior to their initial visit with a vascular surgeon. Patient preference data were elicited using probability trade-off (PTO) assessment and time trade-off (TTO) method. Decision analysis was performed to compare CEA with CAS. Morbidity and mortality rates were obtained from recent literature reports from the same institution. Our results showed that when patients are informed, they prefer and will more often choose CEA over CAS for revascularization of ECAS. Among patients preferring CAS, they expect no more than a 46% increase in the rate of stroke and/or death. Future clinical studies on true stroke rates for CAS will be required to further refine this analysis.

Angioplasty, Balloon↗

Abdominal aortic aneurysms in "high-risk" surgical patients: comparison of open and endovascular repair.

OBJECTIVE: To evaluate the early results of endovascular grafting for high-risk surgical candidates in the treatment of abdominal aortic aneurysms (AAA). SUMMARY BACKGROUND DATA: Since the approval of endoluminal grafts for treatment of AAA, endovascular repair of AAA (EVAR) has expanded to include patients originally considered too ill for open AAA repair. However, some concern has been expressed regarding technical failure and the durability of endovascular grafts. METHODS: The University of Alabama at Birmingham (UAB) Computerized Vascular Registry identified all patients who underwent abdominal aneurysm repair between January 1, 2000, and June 12, 2002. Patients were stratified by type of repair (open AAA vs. EVAR) and were classified as low risk or high risk. Patients with at least one of the following classifications were classified as high risk: age more than 80 years, chronic renal failure (creatinine > 2.0), compromised cardiac function (diminished ventricular function or severe coronary artery disease), poor pulmonary function, reoperative aortic procedure, a "hostile" abdomen, or an emergency operation. Death, systemic complications, and length of stay were tabulated for each group. RESULTS: During this 28-month period, 404 patients underwent AAA repair at UAB. Eighteen patients (4.5%) died within 30 days of their repair or during the same hospitalization. Two hundred seventeen patients (53%) were classified as high risk. Two hundred fifty-nine patients (64%) underwent EVAR repair, and 130 (50%) of these were considered high-risk patients (including four emergency procedures). One hundred forty-five patients (36%) underwent open AAA repair, including 15 emergency operations. All deaths occurred in the high-risk group: 12 (8.3%) died after open AAA repair and 6 (2.3%) died after EVAR repair. Postoperative length of stay was shorter for EVAR repair compared to open AAA. CONCLUSIONS: High-risk and low-risk patients can undergo EVAR repair with a lower rate of short-term systemic complications and a shorter length of stay compared to open AAA. Despite concern regarding the durability of EVAR, high-risk patients should be evaluated for EVAR repair before committing to open AAA repair.

Adult↗

Use of hybrid aortic stent grafts for endovascular repair of abdominal aortic aneurysms: indications and outcomes.

BACKGROUND: Only two aortic stent grafts (Ancure-Guidant, Menlo Park, CA, and AneuRx-Medtronic, Sunnyvale, CA) have been FDA-approved for endovascular aortic aneurysm repair (EndoAAA). These grafts differ significantly in construction and clinical advantage, and combining components of these grafts (hybrid graft) is occasionally necessary. The role and outcome of hybrid aortic stent grafts is unknown. METHODS: All EndoAAA procedures during an 18-month period (10/99-4/01) were reviewed using the hospital record and a computer registry. Endografts were classified as hybrid if components from more than one type of stent graft were used or standard if constructed from only one stent graft type. Hybrid grafts were further classified as "anticipated" or "unanticpated." Outcomes were compared between hybrid and standard grafts using Fisher's exact test. RESULTS: One hundred forty-five EndoAAA repairs were performed (AneuRx, 67; Ancure, 70; and custom-made, 8) of which 14 (9.6%) were hybrid grafts. The majority of hybrid grafts (11) were constructed by adding AneuRx aortic or iliac cuffs to Ancure grafts. In most cases, the need for a hybrid graft was unanticipated (10) and related to an intraoperative proximal type I endoleak (7). Conversion to open operation was avoided in six patients by constructing hybrid grafts. When anticipated (4), hybrid grafts were constructed to treat complex iliac aneurysms. Outcomes in all categories were similar (P > 0.05) for hybrid vs standard grafts: technical success (93 vs 99%), conversion toopen AAA (7.1 vs 2.3%), vascular complications (7.1 vs 7.6%), systemic complications (21 vs 11%), endoleak (15 vs 14%), and rupture (0 vs 0%). CONCLUSIONS: The short-term safety and effectiveness of hybrid grafts are similar to those of standard grafts. Combining graft components to create hybrid grafts may increase the ability to treat complex iliac aneurysmal disease and may reduce conversions to open AAA repair. Thus, access to multiple graft types may be an important factor in the success and safety of EndoAAA repair.

Aortic Aneurysm, Abdominal↗

Quercetin inhibits human vascular smooth muscle cell proliferation and migration.

BACKGROUND: The French paradox has been associated with regular intake of red wine, which is enriched with flavonoids. Quercetin, a flavonoid present in the human diet, exerts cardiovascular protection through its antioxidant properties. We hypothesized that the beneficial effect of quercetin also could be related to the inhibition of vascular smooth muscle cell proliferation and migration. METHODS: Human aortic smooth muscle cells (AoSMC) were grown in culture in the presence of serum. Quercetin inhibited the serum-induced proliferation of AoSMC. This inhibition was dose-dependent and not attributed to toxicity. Cell cycle analysis revealed that quercetin arrested AoSMC in the G(0)/G(1) phase. The effect of quercetin on AoSMC migration was examined using explant migration and Transwell migration assays. Quercetin significantly decreased migration in both assays in a consistent manner. Finally, Western blot analysis of AoSMC exposed to quercetin demonstrated a significant reduction in the activation of mitogen-activated protein kinase, a signaling pathway associated with the migration of vascular smooth muscle cells. CONCLUSIONS: Quercetin inhibits the proliferation and migration of AoSMC, concomitant with inhibition of mitogen-activated protein kinase phosphorylation. These findings provide new insights and a rationale for the potential use of quercetin in the prophylaxis of cardiovascular diseases.

Antioxidants↗

Vascular complications arising from maldeployed stents.

The authors present 6 unusual vascular complications secondary to maldeployed or undeployed vascular stents. They retrospectively reviewed patients referred for complications of vascular stent placement from September 1998 to March 1999. Information on patient history was obtained from a computerized database and clinical document file. Radiographic information was obtained from arteriograms, ultrasound, and computed tomography imaging. Case 1 describes an undeployed stent in the superior mesenteric artery with subsequent thrombosis in addition to celiac occlusion secondary to attempted balloon angioplasty. Case 2 refers to a malpositioned stent placed in the aortic arch and proximal left common carotid artery. Case 3 involves an undeployed coronary stent that migrated to the right distal posterior tibial artery, causing vascular occlusion and chronic pain. In Case 4, an attempted stent placement into the left iliac artery resulted in an undeployed stent lodged across the aortic bifurcation. Case 5 illustrates a partially deployed stent occluding the left renal artery that was unamenable to further angioplasty. Case 6 demonstrates arterial dissection with a pseudoaneurysm following stent placement for right subclavian stenosis. Five patients required operative intervention. Increased use of stents may escalate the number of complications requiring operative intervention. Foreign bodies can migrate distally and potentiate thrombotic occlusion of vessels. Caution must be used not only at the time of deployment but also in the follow-up period. Continued surveillance becomes important after vascular stent placement.

Aged↗

Early results of lower extremity infrageniculate revascularization with a new polytetrafluoroethylene graft.

When an autologous vein is not available for lower extremity revascularization, prosthetic grafts are often required. However, prosthetic bypass grafts have limited patency for infrageniculate reconstruction. To potentially improve patency, a new geometric modification of the polytetrafluoroethylene (PTFE) graft, Distaflo (Impra, Tempe, AZ), has been developed for lower extremity bypass. We reviewed our early experience with the Distaflo graft in patients who required infrageniculate bypass for lower extremity ischemia when no suitable autologous saphenous vein was available. All patients were maintained on warfarin anticoagulation postoperatively. All grafts were followed at 6- to 12-week intervals with duplex ultrasound evaluation. Patient characteristics, operative procedures, and graft surveillance information were maintained on a computerized registry. Thirty-two patients with limb-threatening ischemia underwent 35 infrageniculate reconstructions with a Distaflo graft between February 26, 1999, and August 24, 2000. Thirty-two of 35 bypasses were performed on extremities that had previously undergone a surgical procedure. Forty-eight previous revascularization procedures were done on these 25 extremities. Thirty grafts were constructed to the tibial outflow sites, whereas the remaining five grafts were placed to the below-knee popliteal artery. One patient died on the second postoperative day secondary to unrelated causes, and only one graft (3%) failed during the same hospitalization. Fifteen of 35 grafts (43%) remained patent 1 to 30 months later. Four patent grafts (6%) were ligated between 2 and 14 months for infectious indications. When considering the 20 failed grafts, 9 patients underwent major amputation, 5 patients remain with chronically ischemic limbs, and 6 patients underwent additional bypass grafts. Twenty-three patients (72%) maintained limb salvage. The Distaflo PTFE graft achieves promising early patency for complex infrageniculate revascularization and may be used as an alternative conduit in patients with critical limb ischemia who do not have an adequate vein for lower extremity revascularization.

Aged↗