PubMed Health⌕ Search

Biomedical subjects

Davis Massey

Publications and source records attributed to Davis Massey.

7 recordsLinked to original sources

A new alloantigen-independent control for chronic allograft nephropathy rat models.

BACKGROUND: Isografts are used as controls in many transplant experiments. Our laboratory and others have noticed histological changes in control isograft groups of rats similar to allograft groups, suggesting alloantigen-independent factors contributing to chronic allograft nephropathy. However, the isograft model as a nonalloantigen control is flawed because of the potential of unrecognized minor antigen differences between rats. We designed a study using autografts to isolate alloantigen-independent factors in the rat renal transplant allograft model. MATERIALS AND METHODS: Male Lewis rats weighing 150-250 g underwent a procedure designed to mimic the injury of renal transplant, in which the left kidney was perfused with cold University of Wisconsin solution and subjected to similar cold and warm ischemic times as Lewis isograft rats undergoing renal transplanation. RESULTS: Six autograft rats were compared to five isograft and three single nephrectomy rats. Autograft rats showed normal kidney function according to serum BUN, Cr, and urinary protein. At 360 days, four of six autografts displayed normal renal parenchymal histology, whereas the remaining two autografts displayed histological changes scored as Banff acute rejection 1a and 1b. At sacrifice time, four of five isografts showed histological changes scored as Banff chronic rejection 1 and the single nephrectomy group showed normal histology in the remaining native kidney. CONCLUSIONS: Our data demonstrate that the chronic nephropathy observed in the isograft cannot be completely freed from suspicion of immunological origin. We propose that the autograft model for rat renal transplant research is a better nonimmunologic control than the isograft model for chronic allograft nephropathy.

Animals↗

Potential pitfalls in diagnostic oral pathology: a review for the general surgical pathologist.

Oral developmental, reactive, benign neoplastic and malignant neoplastic conditions, many odontogenic in origin, may not be seen routinely by the general surgical pathologist and therefore may present a diagnostic dilemma. This article describes odontogenic and nonodontogenic conditions with little or no destructive potential along with the more aggressive conditions that resemble them clinically and histologically. The importance of clinical and radiographic correlation as an adjunct to tissue diagnosis is highlighted. Additionally, a brief summary of odontogenesis is presented with attention given to odontogenic embryologic remnants and the developmental and pathologic processes that may arise from them.

Diagnostic Errors↗

Commentary: clinical diagnostic use of cystatin C.

Clinicians recognize and compensate for limitations in estimating the glomerular filtration rate (GFR) using serum creatinine (sCr) measurements by the use of timed collections and mathematical manipulations of sCr. These limitations stem from that fact that sCr is affected by nonrenal influences, including muscle mass and disease state. In addition, sCr may not be sensitive enough to detect minimal declines in GFR in those patient populations in which it is important to recognize early decline. This brief review describes the limitations of sCr, and examines the contribution that sCysC may be able to make in the early recognition of declining renal function. The physiology of CysC is presented, as are the results of clinical investigations that suggest sCysC is in many instances superior to sCr in the recognition of early decline in renal function. Certain exceptions to this are noted.

Biomarkers↗

A pathologist's perspective on bone marrow aspiration and biopsy: I. Performing a bone marrow examination.

The bone marrow aspirate and biopsy is an important medical procedure for the diagnosis of hematologic malignancies and other diseases, and for the follow-up evaluation of patients undergoing chemotherapy, bone marrow transplantation, and other forms of medical therapy. During the procedure, liquid bone marrow is aspirated from the posterior iliac crest or sternum with a special needle, smeared on glass microscope slides by one of several techniques, and stained by the Wright-Giemsa or other techniques for micro-scopic examination. The bone marrow core biopsy is obtained from the posterior iliac crest with a Jamshidi or similar needle and processed in the same manner as other surgical specimens. Flow cytometric examination, cytochemical stains, cytogenetic and molecular analysis, and other diagnostic procedures can be performed on bone marrow aspirate material, while sections prepared from the bone marrow biopsy can be stained by the immunoperoxidase or other techniques. The bone marrow procedure can be performed with a minimum of discomfort to the patient if adequate local anesthesia is utilized. Pain, bleeding, and infection are rare complications of the bone marrow procedure performed at the posterior iliac crest, while death from cardiac tamponade has rarely occurred from the sternal bone marrow aspiration. The recent development of bone marrow biopsy needles with specially sharpened cutting edges and core-securing devices has reduced the discomfort of the procedure and improved the quality of the specimens obtained.

Adult↗

Digital photography: a primer for pathologists.

The computer and the digital camera provide a unique means for improving hematology education, research, and patient service. High quality photographic images of gross specimens can be rapidly and conveniently acquired with a high-resolution digital camera, and specialized digital cameras have been developed for photomicroscopy. Digital cameras utilize charge-coupled devices (CCD) or Complementary Metal Oxide Semiconductor (CMOS) image sensors to measure light energy and additional circuitry to convert the measured information into a digital signal. Since digital cameras do not utilize photographic film, images are immediately available for incorporation into web sites or digital publications, printing, transfer to other individuals by email, or other applications. Several excellent digital still cameras are now available for less than 2,500 dollars that capture high quality images comprised of more than 6 megapixels. These images are essentially indistinguishable from conventional film images when viewed on a quality color monitor or printed on a quality color or black and white printer at sizes up to 11x14 inches. Several recent dedicated digital photomicroscopy cameras provide an ultrahigh quality image output of more than 12 megapixels and have low noise circuit designs permitting the direct capture of darkfield and fluorescence images. There are many applications of digital images of pathologic specimens. Since pathology is a visual science, the inclusion of quality digital images into lectures, teaching handouts, and electronic documents is essential. A few institutions have gone beyond the basic application of digital images to developing large electronic hematology atlases, animated, audio-enhanced learning experiences, multidisciplinary Internet conferences, and other innovative applications. Digital images of single microscopic fields (single frame images) are the most widely utilized in hematology education at this time, but single images of many adjacent microscopic fields can be stitched together to prepare "zoomable" panoramas that encompass a large part of a microscope slide and closely simulate observation through a real microscope. With further advances in computer speed and Internet streaming technology, the virtual microscope could easily replace the real microscope in pathology education. Later in this decade, interactive immersive computer experiences may completely revolutionize hematology education and make the conventional lecture and laboratory format obsolete. Patient care is enhanced by the transmission of digital images to other individuals for consultation and education, and by the inclusion of these images in patient care documents. In research laboratories, digital cameras are widely used to document experimental results and to obtain experimental data.

Computers↗

The virtual blood film.

The computer and the digital camera offer unprecedented possibilities for improving hematology education, research, and patient service. Peripheral blood smear images of exceptional quality can be acquired rapidly and conveniently from the peripheral blood smear with a modern, high-resolution digital camera and a quality microscope. Digital cameras use CCD or CMOS image sensors to measure light energy and additional circuitry to convert the measured information into a digital signal. Because digital cameras do not use photographic film, images are immediately available for incorporation into web sites or digital publications, printing, transfer to other individuals by e-mail, or other applications. Several excellent consumer digital still cameras are now available for less than $1000 that capture high-quality images comprised of more than three megapixels. These images are essentially indistinguishable from conventional film images when viewed on a quality color monitor or printed on a quality color or black and white printer at sizes up to 8 x 10 in. Several recent dedicated digital photomicroscopy cameras provide an ultrahigh quality image output of more than 12 megapixels and have low noise circuit designs permitting the direct capture of darkfield and fluorescence images. There are many applications of digital images of peripheral blood smears. Because hematology is a visual science, the inclusion of quality digital images into lectures, teaching handouts, and electronic documents is essential. A few institutions have gone beyond the basic application of digital images to develop large electronic hematology atlases; animated, audio-enhanced learning experiences; multidisciplinary Internet conferences; and other innovative applications. Digital images of single microscopic fields (single-frame images) are the most widely used in hematology education at this time, but single images of many adjacent microscopic fields can be stitched together to prepare zoomable panoramas that encompass a large part of a microscope slide and closely stimulate observation through a real microscope. With further advances in computer speed and Internet streaming technology, the virtual microscope could easily replace the real microscope in pathology education. Interactive, immersive computer experiences may completely revolutionize hematology education and make the conventional lecture and laboratory format obsolete later in this decade. Patient care is enhanced by the transmission of digital images to other individuals for consultation and education, and by the inclusion of these images in patient care documents. In research laboratories, digital cameras are widely used to document experimental results and obtain experimental data.

Blood Cell Count↗

Immunophenotypic analysis of acute lymphocytic leukemia.

Acute lymphoblastic leukemia (ALL) is one of the most common hematologic malignancies. Flow cytometry is an integral part of ALL diagnosis and also provides significant patient prognostic information. This article is a practical review of the basic principles of the flow cytometric evaluation of acute leukemias, the interpretation of flow cytometric data, and the management of practical problems such as aberrant antigen, hematogones, bone marrow regeneration, and minimal residual disease.

Adult↗