PubMed Health⌕ Search

Biomedical subjects

Dawn M Elliott

Publications and source records attributed to Dawn M Elliott.

23 records · Page 2Linked to original sources

Effect of fiber orientation and strain rate on the nonlinear uniaxial tensile material properties of tendon.

Tendons are exposed to complex loading scenarios that can only be quantified by mathematical models, requiring a full knowledge of tendon mechanical properties. This study measured the anisotropic, nonlinear, elastic material properties of tendon. Previous studies have primarily used constant strain-rate tensile tests to determine elastic modulus in the fiber direction. Data for Poisson's ratio aligned with the fiber direction and all material properties transverse to the fiber direction are sparse. Additionally, it is not known whether quasi-static constant strain-rate tests represent equilibrium elastic tissue behavior. Incremental stress-relaxation and constant strain-rate tensile tests were performed on sheep flexor tendon samples aligned with the tendon fiber direction or transverse to the fiber direction to determine the anisotropic properties of toe-region modulus (E0), linear-region modulus (E), and Poisson's ratio (v). Among the modulus values calculated, only fiber-aligned linear-region modulus (E1) was found to be strain-rate dependent. The E1 calculated from the constant strain-rate tests were significantly greater than the value calculated from incremental stress-relaxation testing. Fiber-aligned toe-region modulus (E(1)0 = 10.5 +/- 4.7 MPa) and linear-region modulus (E1 = 34.0 +/- 15.5 MPa) were consistently 2 orders of magnitude greater than transverse moduli (E(2)0 = 0.055 +/- 0.044 MPa, E2 = 0.157 +/- 0.154 MPa). Poisson's ratio values were not found to be rate-dependent in either the fiber-aligned (v12 = 2.98 +/- 2.59, n = 24) or transverse (v21 = 0.488 +/- 0.653, n = 22) directions, and average Poisson's ratio values in the fiber-aligned direction were six times greater than in the transverse direction. The lack of strain-rate dependence of transverse properties demonstrates that slow constant strain-rate tests represent elastic properties in the transverse direction. However, the strain-rate dependence demonstrated by the fiber-aligned linear-region modulus suggests that incremental stress-relaxation tests are necessary to determine the equilibrium elastic properties of tendon, and may be more appropriate for determining the properties to be used in elastic mathematical models.

Adaptation, Physiological↗

Methods for quasi-linear viscoelastic modeling of soft tissue: application to incremental stress-relaxation experiments.

The quasi-linear viscoelastic (QLV) model was applied to incremental stress-relaxation tests and an expression for the stress was derived for each step. This expression was used to compare two methods for normalizing stress data prior to estimating QLV parameters. The first and commonly used normalization method was shown to be strain-dependent. Thus, a second normalization method was proposed and shown to be strain-independent and more sensitive to QLV time constants. These analytical results agreed with representative tendon data. Therefore, this method for normalizing stress data was proposed for future studies of incremental stress-relaxation, or whenever comparing stress-relaxation at different strains.

Animals↗

Chondropathy after meniscal tear or partial meniscectomy in a canine model.

A primary goal in considering treatment for meniscal injuries is the preservation of the health of the articular cartilage. However, the chondroprotective effects of various techniques for meniscal injury treatments are unknown. We used a canine model to quantify articular cartilage degeneration in the medial compartment of the canine knee, resulting from a surgically created tear or a partial meniscectomy (PM) of the posterior region of the medial meniscus (each group, n = 10). After sacrifice at 12 weeks, the development of gross chondropathy and the changes in cartilage tensile stiffness were quantified, and correlations between these measurements were examined. Both treatment surgical treatment groups caused significantly greater gross chondropathy as compared to the unoperated contralateral controls. Cartilage tensile stiffness was significantly lower than unoperated controls by nearly 28% in both experimental groups. However, there were no significant differences observed between the gross chondropathy or the cartilage mechanical property changes between the experimental groups. Importantly, the severity of gross chondropathy was found to significantly correlate with the decrement in tensile stiffness properties of the articular cartilage. These findings indicate that significant degeneration of canine articular cartilage develops to a similar degree in the presence of a partially healed meniscus tear or a PM of the knee.

Animals↗

Direct measurement of the Poisson's ratio of human patella cartilage in tension.

Articular cartilage has been shown to exhibit large transverse contractions when loaded in tension, suggesting the existence of large values for the Poisson's ratio. Previous studies have suggested that this effect is dependent on amplitude of applied strain, so that a single Poisson's ratio may not be sufficient to describe cartilage behavior. In this study, the Poisson's ratio (v), toe region modulus (Eo), and linear region modulus (E) of human patellar articular cartilage were calculated in simple tension tests from optical analysis of the two-dimensional strain fields at equilibrium. The Poisson's ratio was found to be independent of strain due to the absence of viscoelastic effects during testing. The Poisson's ratio was found to be significantly higher in the surface zone (1.87 +/- 1.11, p<0.01) than in the middle zone (0.62 +/- 0.23), with no significant correlation of v with age of the cartilage. In general, values for Poisson's ratio were greater than 0.5, suggesting cartilage behavior in tension deviates from isotropy. Reported values for the Poisson's ratio of cartilage in compression have been much lower than values measured here in tension, reflecting a mechanical contribution of the collagen fibers to anisotropy in tension but not compression. The toe-region modulus (Eo) was significantly higher in the surface zone (4.51 +/- 2.78 MPa, n=8) compared to the middle zone (2.51 +/- 1.93 MPa, n=10). In addition, the linear-region modulus (E) in the surface zone, but not middle zone (3.42 +/- 2.17 MPa, n=10), was found to correlate with age (R=0.97, p<0.02) with values of surface zone E equal to 23.92 +/- 12.29 MPa (n=5) for subjects under 70 yr of age, and 4.27 +/- 2.89 MPa (n=3) for subjects over 70 yr. Moduli values and trends with depth were consistent with previous studies of human and animal cartilage. From direct measures of two independent material properties, v and E, we calculated a shear modulus, G, which had not been previously reported for cartilage from tensile testing. Calculated values for surface zone G were 3.64 +/- 1.80 MPa for subjects under 70 yr old and 0.96 +/- 0.69 MPa for subjects over 70 yr old, and were significantly higher in the surface zone than in the middle zone (1.10 +/- 0.78 MPa). This study provides an intrinsic measure for the Poisson's ratio of articular cartilage and its dependence on depth which will be important in understanding the nonlinear tension-compression and anisotropic behaviors of articular cartilage.

Adult↗

Joint degeneration following meniscal allograft transplantation in a canine model: mechanical properties and semiquantitative histology of articular cartilage.

This study examined the hypothesis that meniscal allograft transplantation serves a "chondroprotective" role and prevents the histological and biomechanical changes of the articular cartilage following meniscectomy. Skeletally mature mongrel dogs underwent total medial meniscectomy and received either a fresh meniscal allograft ( n=10) or no further treatment ( n=10). Semiquantitative histology and biomechanical analysis of the femoral articular cartilage was used to assess cartilage pathology 12 weeks following surgery. Histological analysis showed significant changes in cartilage structure that did not differ between the meniscectomy and allograft transplantation groups. Similarly, the tensile modulus of the surface zone cartilage was significantly lower than that in unoperated controls following either meniscectomy or allograft transplantation. A significant correlation was observed between the biomechanical and histological changes, suggesting that degenerative changes in cartilage structure and mechanical function are interrelated. Our findings do not support the hypothesis that meniscal allograft transplantation provides chondroprotection of the femoral condyle and also suggest that it does not lead to increased degenerative changes.

Animals↗