PubMed Health⌕ Search

Biomedical subjects

Deborah A Agler

Publications and source records attributed to Deborah A Agler.

At least 19 recordsLinked to original sources

Cardiac resynchronization therapy and the emerging role of echocardiography (part 1): indications and results from current studies.

Cardiac resynchronization therapy (CRT) has been established as an adjunctive treatment for patients with left ventricular systolic dysfunction and medically refractory heart failure with a wide QRS interval. Echocardiography can be used to determine the response in left ventricular structure and function after device implantation and emerging evidence as a method for selection of patients who may derive clinical benefit from CRT. This review discusses the applications of CRT, including results of clinical trials and the current experience using echocardiography. Part 2 will address the practical aspects of obtaining echocardiographic data in patients who are potential candidates for CRT and optimization of pacemaker settings after device implantation.

Cardiac Pacing, Artificial↗

Cardiac resynchronization therapy and the emerging role of echocardiography (part 2): the comprehensive examination.

Cardiac resynchronization therapy has been established as an adjunctive treatment for patients with severe left ventricular systolic dysfunction and medically refractory heart failure symptoms with a prolonged electrocardiographic QRS interval. Echocardiography has emerged as a useful method to evaluate patients who are considered for cardiac resynchronization therapy. This review outlines measurements of ventricular performance to be used in this patient population including echocardiographic optimization of cardiac resynchronization therapy device settings.

Cardiac Pacing, Artificial↗

Asymmetry of systolic anterior motion of the mitral valve in patients with hypertrophic obstructive cardiomyopathy: a real-time three-dimensional echocardiographic study.

By geometric analysis of real-time 3-dimensional echocardiography performed in 39 patients with hypertrophic obstructive cardiomyopathy and definite systolic anterior motion of the mitral valve, we found that the angle between the mitral annular plane and basal portion of the anterior mitral valve leaflet, and the angle between the basal portion of the anterior leaflet and its tip portion measured in the medial and central anteroposterior planes, were significantly smaller than those in the lateral plane. The distance between the interventricular septum and the anterior mitral valve tip in the medial and central plane was also significantly smaller than that in the lateral plane. The lateral distance between the interventricular septum and the anterior mitral valve tip was the only independent determinant of left ventricular outflow tract pressure gradient by multiple stepwise regression analysis. In conclusion, systolic anterior motion of the mitral valve develops predominantly in the medial side, resulting in laterally located narrow left ventricular outflow tract opening in patients with hypertrophic obstructive cardiomyopathy.

Adult↗

Determinants of ischemic mitral regurgitation in patients with chronic anterior wall myocardial infarction: a real time three-dimensional echocardiography study.

OBJECTIVE: We sought to elucidate the geometric determinants of ischemic mitral regurgitation (IMR) in patients with chronic anterior myocardial infarction (MI). MATERIALS AND METHODS: In 16 patients with anterior MI only (Group A) and 18 patients with both anterior and inferoposterior MI (Group B), three parallel equidistant anteroposterior (AP) planes (medial, central, lateral) perpendicular to the mitral valvular commissure-commissure plane were generated. The systolic tenting area of the mitral valve (MVTa) and the angles between the annular plane and leaflets (anterior, Aalpha; posterior, Palpha) on the AP planes were measured. The left ventricular end-systolic and end-diastolic volumes, and end-diastolic and end-systolic mitral annular area (MAAs) were obtained. RESULT: The regurgitant orifice area (ROA) was significantly smaller in Group A than Group B (0.08 +/- 0.09 vs 0.20 +/- 0.18 cm(2), P < 0.05). In the total of 34 patients, the medial MVTa (P < 0.001), MAAs (P < 0.05) and the spherical index (P < 0.05) were three independent determinants of ROA while the left ventricular volumes were not. MAAs was the only independent determinant of ROA in Group A, while the medial MVTa was in Group B. Palpha (P < 0.05) and MVTa (P = 0.06) tended to be larger in the medial than the lateral side in Group B, while no differences were found in Group A. CONCLUSION: The geometry of the mitral valve apparatus was more important than the left ventricular volumes in determining the severity of IMR in patients with anterior MI. The posteromedial side tenting could play a critical role in causing significant IMR when the inferoposterior MI coexists with anterior MI.

Aged↗

Electrical conduction disturbance effects on dynamic changes of functional mitral regurgitation.

OBJECTIVES: The aim of this study was to investigate the relationship between dynamics of functional mitral regurgitation (MR) and the degree of electrical conduction disturbance, and to evaluate the impact of cardiac resynchronization therapy (CRT) on MR severity and its phasic pattern. BACKGROUND: Mechanisms of phasic changes of functional MR, which may be determined by annulus dilation and tethering of the leaflet, remain unclear. METHODS: Transthoracic two-dimensional echocardiography was performed in 60 patients with functional MR. A biventricular pacemaker was implanted in 19 patients. The mitral annulus area (MAA) and the tenting area (TA) were measured from apical views. The MR volume and fraction were assessed by the quantitative pulsed Doppler method. Instantaneous regurgitation flow rate was measured by proximal flow convergence method. A dynamic change in MR flow rate was evaluated by frame-by-frame analysis throughout systole. RESULTS: A phasic pattern with two peaks at early- and late-systole and decrease in mid-systole was noticed in 57 patients. The early-systolic peak of MR was larger than the late-systolic peak (128.4 +/- 64.3 ml/s vs. 73.9 +/- 55.1 ml/s, p < 0.001). The ratio of flow rate at these two peaks correlated with QRS duration (r = 0.55, p < 0.001). Early-systolic flow rate reduced after CRT (143.9 +/- 60.8 ml/s to 90.7 +/- 54.1 ml/s, p < 0.05), but late-systolic flow rate did not (61.5 +/- 55.0 ml/s to 51.2 +/- 40.9 ml/s, p = NS). A similar pattern was observed for TA, whereas MAA did not change after CRT. CONCLUSIONS: Biphasic pattern was found in functional MR, and the ratio of flow rate at two peaks correlated with QRS duration. The CRT decreased regurgitation flow volume by reducing early-systolic MR but not late-systolic MR, resulting in the change in phasic pattern of functional MR.

Aged↗

Evaluation of left ventricular outflow tract area after septal reduction in obstructive hypertrophic cardiomyopathy: a real-time 3-dimensional echocardiographic study.

BACKGROUND: The comparative impact of percutaneous alcohol septal reduction (ASR) and surgical myectomy on the left ventricular outflow tract (LVOT) area in patients with obstructive hypertrophic cardiomyopathy (HC) is not well defined. Real-time 3-dimensional echocardiography (RT3DE) provides accurate information about the LVOT geometry and shape. We aimed to analyze the change in LVOT area after septal reduction interventions in patients with obstructive HC using RT3DE. METHODS: Thirty-one HC patients (mean age 53 +/- 17 years) undergoing ASR (n = 14) or myectomy (n = 17) were studied at baseline and during follow-up with RT3DE. LVOT area was measured after observing the LVOT in the 3D space as the smallest area during midsystole. LVOT pressure gradients were determined by conventional continuous wave Doppler. RESULTS: Overall, LVOT area increased from 0.86 +/- 0.20 to 2.50 +/- 0.88 cm2 (P < .01), and the resting LVOT pressure gradient decreased from 64 +/- 41 to 16 +/- 10 mm Hg (P < .01) after a median follow-up of 3 months after intervention (range 1-24 months). A similar significant decrease in LVOT pressure gradients was seen in myectomy and ASR groups (from 62 +/- 39 to 12 +/- 5 mm Hg and from 67 +/- 43 to 21 +/- 14 mm Hg, respectively, P < .01 in between each group, and P = NS between both groups). However, the increase in LVOT area was greater in myectomy than in ASR group (from 0.81 +/- 0.22 to 2.90 +/- 0.64 cm2 and 0.93 +/- to 0.16 to 2.02 +/- 0.92 cm2, respectively, P < .01 between both groups). CONCLUSION: RT3DE demonstrated an effective increase in LVOT area after both ASR and myectomy. This technique may be useful for assessing the results of septal reduction in patients with obstructive HC.

Adolescent↗

Automated mitral annular tracking: a novel method for evaluating mitral annular motion using two-dimensional echocardiography.

We developed an automated mitral annular tracking method based on a digital processing of high frame rate cineloop images of 2-dimensional echocardiography. In this study, its feasibility and accuracy was validated in 11 healthy volunteers and 16 patients with left ventricular (LV) dysfunction. The mitral annular excursion measured by automated mitral annular tracking agreed well with that measured by 3-dimensional echocardiography and correlated with LV ejection fraction. The longitudinal mitral annular excursion was reduced whereas the radial one was preserved for patients with LV dysfunction compared with control subjects. The novel automated mitral annular tracking method is clinically feasible and has potential capability to quantify the comprehensive mitral annular motion for evaluating LV function in a clinical setting.

Adult↗

Usefulness of real-time three-dimensional echocardiography for evaluation of myectomy in patients with hypertrophic cardiomyopathy.

Real-time 3-dimensional echocardiography was performed in 10 patients with obstructive hypertrophic cardiomyopathy (HC) before and after myectomy and in 6 controls. The exact location of systolic anterior motion of the mitral leaflet was shown in all patients with HC with a predominant involvement of the medial portion in 4 patients and the middle portion in 6 patients. The smallest area of the left ventricular outflow tract was significantly smaller in patients with HC than in controls (1.4 +/- 0.7 vs 5.1 +/- 1.2 cm(2), p <0.01), significantly increased after myectomy (4.8 +/- 1.8 cm2, p <0.01) and was associated with a reduction of the pressure gradient at rest from 63 +/- 41 to 15 +/- 5 mm Hg (p <0.01).

Adult↗

Conduction system abnormalities in patients with obstructive hypertrophic cardiomyopathy following septal reduction interventions.

We observed the impact of percutaneous transluminal septal myocardial ablation (PTSMA) and myectomy on the conduction system in patients with obstructive hypertrophic cardiomyopathy (HC). Septal reduction intervention is capable of eliminating the left ventricular outflow tract obstruction in patients with obstructive HC; however, conduction system abnormalities are frequent consequences of these procedures. A standard 12-lead electrocardiogram and Doppler echocardiogram were obtained in 204 patients who underwent PTSMA (n = 70) or myectomy (n = 134) before and at average of 3 months after intervention. Of 146 patients who had normal conduction systems before intervention, the duration of the QRS complex was significantly prolonged from 98 +/- 15 to 130 +/- 25 ms (p <0.0001), with right bundle branch block (RBBB) developing in 62% patients after PTSMA, and from 100 +/- 13 to 154 +/- 20 ms (p <0.0001), with left bundle branch block (LBBB) developing in 93% patients after myectomy. No significant difference in the QRS duration was found in the remaining 58 patients who had preexisting conduction abnormalities after intervention. In 174 patients without a preexisting permanent pacemaker, a pacemaker was implanted in 22% versus 13% of patients who underwent PTSMA (overall and without preexisting conduction block, respectively) and 10% versus 2% of patients with myectomy. The duration of baseline QRS was an independent predictor for the requirement of a permanent pacemaker (p <0.0001). Thus, RBBB often develops after PTSMA and LBBB is very frequently produced by myectomy. A possible requirement of a permanent pacemaker should always be considered before intervention when patients have preexisting RBBB or LBBB.

Bundle-Branch Block↗

The pseudorestrictive pattern of transmitral Doppler flow pattern after conversion of atrial fibrillation to sinus rhythm: is atrial or ventricular dysfunction to blame?

Patients with paroxysmal atrial fibrillation (AF) who have recently converted from AF to sinus rhythm often exhibit a restrictive Doppler pattern in the transmitral flow (TMF) velocity. However, the mechanism of this phenomenon has not been well defined. We evaluated the temporal change of TMF pattern and hemodynamics after conversion of AF to in sinus rhythm in an animal model. Eight open-chest dogs underwent 3 hours of pacing-induced AF. TMF velocities and pressure data were acquired at baseline (sinus rhythm), immediately after conversion of AF, and every 10 minutes thereafter. Early diastolic TMF velocity was increased immediately after conversion and recovered to the baseline value in 20 minutes. Atrial systolic TMF velocity was reduced after AF and recovered to baseline value in 20 to 30 minutes. Early diastolic/atrial systolic TMF velocity was increased after conversion, and recovered to baseline value in 20 to 30 minutes. The mean left atrial (LA) pressure increased immediately, 10 and 20 minutes after the conversion of AF to sinus rhythm. The left ventricular end-diastolic pressure was increased and positive left ventricular dP/dt and tau were decreased immediately after AF, whereas they recovered within 10 minutes. In conclusion, a pseudorestrictive pattern of TMF after AF occurred as a result of transient LA mechanical functional impairment and increased LA pressure caused by LA stunning. Transient left ventricular diastolic dysfunction also effected the TMF velocity immediately after the conversion from AF to sinus rhythm, although it recovered faster than LA mechanical dysfunction.

Animals↗

In vivo short-term Doppler hemodynamic profiles of 189 Carpentier-Edwards Perimount pericardial bioprosthetic valves in the mitral position.

We sought to determine the hemodynamic performance of the Carpentier-Edwards Perimount pericardial valve in the mitral position. We reviewed the Doppler echocardiographic data on 189 patients (110 women; 68 +/- 12 years of age) who were implanted with this valve (7.6 days +/- 13 postoperatively) at our institution between September 2000 and May 2002. The average ejection fraction was 47%. For all valves, the peak velocity was 1.9 +/- 0.3 m/s, peak gradient was 15 +/- 4.8 mm Hg, and mean gradient was 5.8 +/- 2 mm Hg. The pressure half-time was 93 +/- 24 milliseconds, with a calculated effective orifice area of 2.5 +/- 0.6 cm2. The average effective orifice area by continuity equation (83 valves) was 1.5 +/- 0.5 cm2. The mitral regurgitation was graded mild or less in 97.5% of all valves. This is the largest series establishing the favorable hemodynamic behavior of the different sizes of a new Perimount mitral valve, and the reported data could serve as a reference.

Adult↗

Geometric changes of mitral annulus assessed by real-time 3-dimensional echocardiography: becoming enlarged and less nonplanar in the anteroposterior direction during systole in proportion to global left ventricular systolic function.

OBJECTIVE: We sought to investigate the geometric changes of the mitral annulus during systole in relation to global left ventricular (LV) systolic function using real-time 3-dimensional (3D) echocardiography. METHODS: Real-time 3D echocardiography was performed in 23 patients with global LV systolic dysfunction with ejection fraction of 37 +/- 19% and 9 control subjects with ejection fraction of 62 +/- 4%. Volumetric data were divided into 9 rotational apical planes (angle increment = 20 degrees) using 3D software. Nine rotational annular dimensions (ADs) were measured in all planes in early and late systole. Nonplanar angle (NPA) of the annulus between two vectors from two hinge points of the annulus in the anteroposterior plane to the center between two commissures in the commissure-commissure plane was measured during early and late systole. Fractional changes of NPA and AD were defined as changes in percentage during systole. RESULTS: NPA significantly increased during systole (early, 145 +/- 12 degrees; late, 160 +/- 9 degrees; P < .01). Among 9 ADs, 3 anteroposteriorly directed ADs showed the most prominent fractional increases during systole in all patients. Both fractional changes of NPA ( R 2 = 0.87, P < .01) and the anteroposterior dimension, AD 1 ( R 2 = 0.85, P < .01) showed significant positive correlation with global LV systolic function. CONCLUSIONS: Real-time 3D echocardiography demonstrated that saddle shape of the mitral annulus was getting enlarged and less nonplanar mainly in the anteroposterior direction during systole. These geometric changes were proportional to the global LV systolic function.

Adult↗

Mitral annular motion as a surrogate for left ventricular ejection fraction: real-time three-dimensional echocardiography and magnetic resonance imaging studies.

AIMS: To validate the accuracy of mitral annular motion assessed by real-time three-dimensional echocardiography (RT3DE) as a surrogate for determination of the left ventricular function in comparison with magnetic resonance imaging (MRI). METHODS AND RESULTS: Forty-seven patients with a variety of cardiac pathologies underwent both RT3DE and MRI exams. After 3D data sets were transferred to a PC with a custom-made program, nine consecutive rotational apical plane images (20 degrees apart) were displayed. The two mitral leaflet insertion points were manually identified in each plane. The geometry of the mitral annulus was reconstructed from a total of 18 coordinates (x, y, z), and the changes in mitral annular area and mitral annular motion along the apical long axis were calculated. The left ventricular ejection fraction (LVEF) determined by MRI was 41+/-18%, and 24 patients had LVEF<50%. Mitral annular motion (y) obtained by RT3DE was 11+/-5 mm and correlated moderately well with LVEF (x) measured by MRI (r=0.84, y=0.25x+0.43, p<0.0001). The mitral annular motion<12 mm was a good threshold for detecting LVEF<50% with 96% sensitivity, 85% specificity, and 91% accuracy. CONCLUSION: Mitral annular motion determined by RT3DE correlated moderately well with LVEF; and systolic motion, <12 mm, accurately detected LV dysfunction.

Adult↗

Importance of mitral valve repair associated with left ventricular reconstruction for patients with ischemic cardiomyopathy: a real-time three-dimensional echocardiographic study.

BACKGROUND: Left ventricular (LV) reconstruction surgery leads to early improvement in LV function in ischemic cardiomyopathy (ICM) patients. This study was designed to evaluate the impact of mitral valve (MV) repair associated with LV reconstruction on LV function 1-year after surgery in ICM patients assessed by real-time 3-dimensional echocardiography (3DE). METHODS AND RESULTS: Sixty ICM patients who underwent the combination surgery (LV reconstruction in 60, MV repair in 30, and revascularization in 52 patients) were studied. Real-time 3DE was performed and LV volumes were obtained at baseline, discharge, 6-month and >or=12-month follow-up. Reduction in end-diastolic volumes (EDV) by 29% and in end-systolic volumes by 38% were demonstrated immediately after surgery and remained at subsequent follow-up (P<0.0001). The LV ejection fraction significantly increased by about 10% at discharge and was maintained >or=12-month (P<0.0001). Although the LV volumes were significantly larger in patients with MV repair before surgery (EDV, 235+/-87 mL versus 193+/-67 mL, P<0.05), they were similar to LV volumes of the patients without MV repair at subsequent follow-ups. However, the EDV increased from 139+/-24 mL to 227+/-79 mL (P<0.01) in 7 patients with recurrent mitral regurgitation (MR). Improvement in New York Heart Association functional class occurred in 81% patients during late follow-up. CONCLUSIONS: Real-time 3DE demonstrates that LV reconstruction provides significant reduction in LV volumes and improvement in LV function which is sustained throughout the 1-year follow-up with 84% cardiac event free survival. If successful, MV repair may prevent LV redilation, while recurrent MR is associated with increased LV volumes.

Echocardiography, Three-Dimensional↗

Comparison of left ventricular diastolic function in obstructive hypertrophic cardiomyopathy in patients undergoing percutaneous septal alcohol ablation versus surgical myotomy/myectomy.

Both percutaneous transcoronary alcohol septal reduction (ASR) and surgical myectomy are effective treatments to relieve left ventricular (LV) outflow tract obstruction in obstructive hypertrophic cardiomyopathy (HC). LV diastolic function was assessed by echocardiography in 57 patients with obstructive HC at baseline and 5 +/- 4 months after ASR (n = 37) or surgical myectomy (n = 20). LV outflow tract pressure gradient decreased from 65 +/- 40 to 23 +/- 21 mm Hg (p <0.01) after treatment. The ratio of the early-to-late peak diastolic LV inflow velocities, and the ratio of the early peak diastolic LV inflow velocity to the lateral mitral annulus early diastolic velocity determined by tissue Doppler imaging significantly decreased after the procedures (1.6 +/- 1.7 vs 1.0 +/- 0.7 and 15 +/- 8 vs 11 +/- 5, respectively), whereas LV inflow propagation velocity significantly increased (60 +/- 24 vs 71 +/- 36 cm/s). Left atrial size decreased from 29 +/- 7 to 25 +/- 6 cm(2) (p <0.05). Patients had a significant improvement in New York Heart Association functional class and in exercise performance. When comparing ASR with myectomy, no difference was found in the degree of change in any parameter of diastolic function. Thus, diastolic function indexes obtained by echocardiography changed after septal reduction interventions in patients with obstructive HC; this change was similar to that after surgical myectomy and ASR.

Adolescent↗

Geometric differences of the mitral apparatus between ischemic and dilated cardiomyopathy with significant mitral regurgitation: real-time three-dimensional echocardiography study.

BACKGROUND: This study was conducted to elucidate the geometric differences of the mitral apparatus in patients with significant mitral regurgitation caused by ischemic cardiomyopathy (ICM-MR) and by idiopathic dilated cardiomyopathy (DCM-MR) by use of real-time 3D echocardiography (RT3DE). METHODS AND RESULTS: Twenty-six patients with ICM-MR caused by posterior infarction, 18 patients with DCM-MR, and 8 control subjects were studied. With the 3D software, commissure-commissure plane and 3 perpendicular anteroposterior (AP) planes were generated for imaging the medial, central, and lateral sides of the mitral valve (MV) during mid systole. In 3 AP planes, the angles between the annular plane and each leaflet (anterior, Aalpha; posterior, Palpha) were measured. In ICM-MR, Aalpha measured in the medial and central planes was significantly larger than that in the lateral plane (39+/-5 degrees, 34+/-6 degrees, and 27+/-5 degrees, respectively; P<0.01), whereas Palpha showed no significant difference in any of the 3 AP planes (61+/-7 degrees, 57+/-7 degrees, and 56+/-7 degrees, P>0.05). In DCM-MR, both Aalpha (38+/-8 degrees, 37+/-9 degrees, and 36+/-7 degrees, P>0.05) and Palpha (59+/-6 degrees, 58+/-5 degrees, and 57+/-6 degrees, P>0.05) revealed no significant differences in the 3 planes. CONCLUSIONS: The pattern of MV deformation from the medial to the lateral side was asymmetrical in ICM-MR, whereas it was symmetrical in DCM-MR. RT3DE is a helpful tool for differentiating the geometry of the mitral apparatus between these 2 different types of functional mitral regurgitation.

Cardiomyopathies↗

Real-time three-dimensional color doppler evaluation of the flow convergence zone for quantification of mitral regurgitation: Validation experimental animal study and initial clinical experience.

BACKGROUND: Pitfalls of the flow convergence (FC) method, including 2-dimensional imaging of the 3-dimensional (3D) geometry of the FC surface, can lead to erroneous quantification of mitral regurgitation (MR). This limitation may be mitigated by the use of real-time 3D color Doppler echocardiography (CE). Our objective was to validate a real-time 3D navigation method for MR quantification. METHODS: In 12 sheep with surgically induced chronic MR, 37 different hemodynamic conditions were studied with real-time 3DCE. Using real-time 3D navigation, the radius of the largest hemispherical FC zone was located and measured. MR volume was quantified according to the FC method after observing the shape of FC in 3D space. Aortic and mitral electromagnetic flow probes and meters were balanced against each other to determine reference MR volume. As an initial clinical application study, 22 patients with chronic MR were also studied with this real-time 3DCE-FC method. Left ventricular (LV) outflow tract automated cardiac flow measurement (Toshiba Corp, Tokyo, Japan) and real-time 3D LV stroke volume were used to quantify the reference MR volume (MR volume = 3DLV stroke volume - automated cardiac flow measurement). RESULTS: In the sheep model, a good correlation and agreement was seen between MR volume by real-time 3DCE and electromagnetic (y = 0.77x + 1.48, r = 0.87, P <.001, delta = -0.91 +/- 2.65 mL). In patients, real-time 3DCE-derived MR volume also showed a good correlation and agreement with the reference method (y = 0.89x - 0.38, r = 0.93, P <.001, delta = -4.8 +/- 7.6 mL). CONCLUSIONS: real-time 3DCE can capture the entire FC image, permitting geometrical recognition of the FC zone geometry and reliable MR quantification.

Adult↗