PubMed Health⌕ Search

Biomedical subjects

Dennis R Weller

Publications and source records attributed to Dennis R Weller.

2 recordsLinked to original sources

An isocratic liquid chromatography method for determining HIV non-nucleoside reverse transcriptase inhibitor and protease inhibitor concentrations in human plasma.

An efficient, isocratic high performance liquid chromatography (HPLC) method for determining human immunodeficiency virus (HIV) non-nucleoside reverse transcriptase inhibitors (NNRTIs) and protease inhibitors (PIs) in plasma is advantageous for laboratories participating in clinical trials and therapeutic drug monitoring (TDM) programs, or conducting small animal research. The combination of isocratic reversed phase chromatography using an S-3, 3.0 mm x 150 mm column along with low plasma volume (200 microl), rapid liquid-liquid extraction, and detection at a single wavelength (212 nm) over a short run time makes this method valuable. Within and between assay variability ranges from 0.8 to 3.5% and 1.2-6.2%, respectively. Accuracy ranges from 91.0 to 112.8% for four quality controls (50, 100, 1000, and 10,000 ng/ml) for all drugs measured (efavirenz, nevirapine, amprenavir, atazanavir, indinavir, lopinavir, nelfinavir, ritonavir, and saquinavir).

Alkynes↗

High-performance liquid chromatographic method for the determination of gemcitabine and 2',2'-difluorodeoxyuridine in plasma and tissue culture media.

Gemcitabine, a pyrimidine antimetabolite undergoes metabolism by plasma and liver cytidine deaminase to form the inactive compound, 2',2'-difluorodeoxyuridine (dFdU). The parent molecule is activated by intracellular phosphorylation. To evaluate the population pharmacokinetics in patients receiving gemcitabine, and to test the relation between gemcitabine infusion rate and antitumor activity in an in vitro bioreactor cell culture system, we developed and validated a sensitive and specific HPLC-UV method for gemcitabine and dFdU. Deproteinized plasma is vortexed, centrifuged, and 25 microL of the acidified extract sample is injected onto a Waters Spherisorb 4.6 mm x 250 mm, 5 microm C18 column at 40 degrees C. The mobile phase (flow rate, 1.0 mL/min) consists of 10:90 (v/v) acetonitrile-aqueous buffer (50 mM sodium phosphate and 3.0 mM octyl sulfonic acid, pH 2.9). Gemcitabine, dFdU, and the internal standard, 2'-deoxycytidine (2'dC) were detected with UV wavelength set at 267 nm. The standard curves for gemcitabine in both matrices ranged from 2 to 200 microM, and for dFdU in plasma, from 2 to 100 microM. Within-run and between-run component precision (CV%) was <or=6.1 and 5.7%, respectively for both human plasma and tissue culture media, and for dFdU, 2.3 and 2.7%. Total accuracy ranged from 98.7 to 106.2% for human plasma and from 96.9 to 99.2% for tissue culture media, respectively, and for dFdU, from 96.5 to 99.6%. Tetrahydrouridine (THU), an inhibitor of cytidine deaminase is used to prevent breakdown in human plasma. With one method we can measure gemcitabine in both plasma and tissue culture media. Utility is demonstrated by evaluation of the disposition of gemcitabine in an in vitro bioreactor cell culture system.

Bioreactors↗