Patent foramen ovale using the Premere device: the results of the CLOSEUP trial.

OBJECTIVES: The CLOSEUP trial was conducted to determine the safety and effectiveness of the Premere closure device in closure of patent foramen ovale (PFO). BACKGROUND: PFO is a relatively common congenital condition, associated with cryptogenic stroke and migraine with aura. The Premere device is specifically designed to close PFO of variable size and length, with right and left anchor arms connected by a flexible tether. The device has an open architecture, a low profile, and a small surface area on the left atrial side which may discourage thrombus formation. METHODS: Patients between 18 and 65 years of age who had a cryptogenic ischemic stroke or a transient ischemic attack and a PFO underwent percutaneous PFO closure using the Premere device. RESULTS: Of the 73 enrolled patients, six patients had atrial anatomy not appropriate for the Premere; 27 patients received the 15 mm and 40 patients received the 20 mm device. Implantation was successful in all patients. At 6 months of follow-up, 86% of patients had no shunt that could be provoked with Valsalva as assessed during contrast echocardiography. Closure rates were better with the 20 mm versus the 15 mm device, and three patients with residual shunt had atrial septal aneurysms at baseline. One patient had transient atrial fibrillation which resolved by 3 months. There were no instances of thrombus, death, or stroke. CONCLUSIONS: These data demonstrate that the Premere device can safely and effectively close PFO. Additional studies should be undertaken to demonstrate the effectiveness of PFO closure in reducing thrombo-embolic events such as stroke.

Adolescent↗

Venture wire control catheter.

We wished to test the safety and efficacy of a novel wire control catheter for use during percutaneous coronary intervention. The ability to vary the angulation of the tip of an intravascular guidewire would often be desirable. Previous attempts to produce deflectable-tip guidewire systems have met with limited success. The Venture wire control catheter (Velocimed, Minneapolis, MN) was used to facilitate percutaneous coronary intervention in 20 patients. There were no device-related complications. Percutaneous coronary intervention was successful in all patients. Our initial experience with the Venture wire control catheter has been favorable.

Aged↗

Effectiveness and safety of the Proxis system in demonstrating retrograde coronary blood flow during proximal occlusion and in capturing embolic material.

The Feasibility And Safety Trial for its embolic protection device during transluminal intervention in coronary vessels: a European Registry (FASTER) was designed to demonstrate that (1) the Proxis embolic protection system can control anterograde flow and reverse blood flow in native coronary arteries and saphenous vein grafts; and (2) this system can capture embolic debris. Percutaneous coronary intervention on stenotic coronary lesions revolutionized treatment of coronary disease, but is associated with the risk of major adverse cardiac events. This prospective, nonrandomized, multicenter clinical feasibility and safety study enrolled 40 patients with 51 lesions at 4 centers who underwent treatment of stenotic lesions with proximal emboli protection (Proxis system). Proxis was successfully used 95% of the time, and embolic debris was qualitatively identified in all cases. Major adverse cardiac events occurred in 2 patients (5.0%): 1 late in-stent thrombosis resulting in death and 1 non-Q-wave infarction when a lesion was crossed before deployment of the Proxis system. Mean vessel occlusion time was 4.3 +/- 2.4 minutes. Native flow reversal was sufficient in 31 patients, with a mean aspirate volume of 11.8 +/- 6.5 ml. When the infusion catheter was used to augment reflow, mean occlusion time was 4.6 minutes. In conclusion, this trial is the first to demonstrate that retrograde blood flow can be achieved during proximal occlusion and that the Proxis system can be used safely during intervention of saphenous vein grafts and native coronary arterial lesions to capture embolic material.

Aged↗