Vertebroplasty versus kyphoplasty: biomechanical behavior under repetitive loading conditions.

STUDY DESIGN: Ex vivo biomechanical study using osteoporotic cadaveric fractured vertebral bodies. OBJECTIVE: To investigate the behavior of fractured osteoporotic vertebral bodies treated with either vertebroplasty or kyphoplasty under repetitive loading conditions. SUMMARY OF BACKGROUND DATA: Vertebroplasty and kyphoplasty are newer alternatives for the treatment of osteoporotic vertebral fractures. Loading conditions that can lead to fractures treated with these methods will likely be encountered subsequently; as such, it is important to understand differences in the biomechanical behavior of the resultant constructs. METHODS: There were 7 pairs of osteoporotic T8 and T10 vertebral bodies cyclically loaded to produce a vertebral compression fracture. Of each pair, one was assigned to the kyphoplasty group and the other to the vertebroplasty group. After treatment, specimens were cyclically loaded to 100,000 cycles, between 20% and 70% of the predicted failure load. RESULTS: Height was restored with kyphoplasty, but the vertebral bodies showed significant height loss during cyclic loading. Vertebroplasty specimens had higher compression stiffness and smaller height reduction. CONCLUSIONS: Under repetitive loading conditions, fractured vertebral bodies treated with kyphoplasty were initially taller, but because of a progressive loss of height during loading, the resulting constructs were shorter after 100,000 cycles than those treated with vertebroplasty.

Aged↗

Distal biceps tendon repair: a biomechanical comparison of intact tendon and 2 repair techniques.

BACKGROUND: A variety of techniques have been described for distal biceps tendon reattachment-bone tunnel with transosseous sutures, suture anchors, and interference screw techniques. HYPOTHESIS: There will be no significant difference between the mean failure strength, maximum strength, and stiffness of the intact specimen and repair techniques tested: bone tunnel with transosseous sutures and interference screw. STUDY DESIGN: Controlled laboratory study. METHODS: Nine matched pairs of fresh-frozen human cadaveric elbows were prepared. The intact tendon was pulled from the radial tuberosity; the right and left elbows were randomized to bone tunnels with transosseous sutures or interference screw repair techniques. The repaired specimens were pulled using the same regimen for the intact tendon. Failure strength, maximum strength, and stiffness were measured and compared. RESULTS: The mean failure strength, maximum strength, and stiffness of intact tendons were 204.3 +/- 76.9 N, 221.7 +/- 65.9 N, and 30.1 +/- 12.4 N/mm, respectively; for the interference screw specimens, 178.0 +/- 54.5 N, 192.1 +/- 53.1 N, and 30.4 +/- 9.5 N/mm, respectively; and for the bone tunnel specimens, 124.9 +/- 22.8 N, 206.6 +/- 49.8 N, and 15.9 +/- 5.6 N/mm, respectively. There were no significant differences between measures in the intact and interference screw specimens. Mean failure strength and stiffness of the bone tunnel specimens were significantly lower than those of the intact and interference screw specimens; there was no significant difference between the maximum strengths of the treatments. Interference screw failure occurred abruptly with little plastic deformation in nearly all specimens with the tendon and screw pulling out as a unit, often involving fracture of the radial wall. Two of the bone tunnels failed at the bony bridge; the remainder lost bone-tendon contact as the distal tendon was shredded by the suture. CONCLUSION: The results suggest interference screw fixation repair is nearly as strong and stiff as the intact tendon and stronger than the bone tunnel repair technique. CLINICAL RELEVANCE: The interference screw provides better stiffness and failure strength compared with the bone tunnel technique for distal biceps tendon repair. Given the superior mechanical properties, the interference screw technique is recommended as the treatment of choice for biceps tendon rupture repair.

Aged↗

Effects of hydrostatic pressure and transforming growth factor-beta 3 on adult human mesenchymal stem cell chondrogenesis in vitro.

This study examined the effects of intermittent hydrostatic pressure (IHP) and transforming growth factor-beta 3 on chondrogenesis of adult human mesenchymal stem cells (hMSCs) in vitro. Chondrogenic gene expression was determined by quantifying mRNA signal levels for SOX9, a transcription factor critical for cartilage development and the cartilage matrix proteins, aggrecan and type II collagen. Extracellular matrix production was determined by weight and histology. IHP was applied to hMSCs in pellet culture at a level of 10 MPa and a frequency of 1 Hz for 4 h per day for periods of 3, 7, and 14 days. hMSCs responded to addition of TGF-beta 3 (10 ng/mL) with a greater than 10-fold increase (p < 0.01) in mRNA levels for each, SOX9, type II collagen, and aggrecan during a 14-day culture period. Applying IHP in the presence of TGF-beta 3 further increased the mRNA levels for these proteins by 1.9-, 3.3-, and 1.6-fold, respectively, by day 14. Chondrogenic mRNA levels were increased with just exposure to IHP. Extracellular matrix deposition of type II collagen and aggrecan increased in the pellets as a function of treatment conditions and time of culture. This study demonstrated adjunctive effects of IHP on TGF-beta 3-induced chondrogenesis and suggests that mechanical loading can facilitate articular cartilage tissue engineering.

Adult↗

Dose- and time-dependent effects of cyclic hydrostatic pressure on transforming growth factor-beta3-induced chondrogenesis by adult human mesenchymal stem cells in vitro.

This study examined effects of varying magnitudes of intermittent hydrostatic pressure (IHP) applied for different times on chondrogenesis of adult human mesenchymal stem cells (hMSCs) in vitro. hMSCs were exposed to 0.1, 1, and 10 MPa of IHP at a frequency of 1 Hz for 4 h/day for 3, 7, and 14 days in the presence of transforming growth factor (TGF-beta3). Chondrogenesis was characterized by gene expression, macromolecule production, and extracellular matrix deposition. Exposure of hMSCs to 0.1 MPa of IHP increased SOX9 and aggrecan mRNA expression by 2.2- and 5.6-fold, respectively, whereas type II collagen mRNA expression responded maximally at 10 MPa. Production of sulfated glycosaminoglycan responded to IHP of 1 MPa and 10 MPa, whereas collagen levels increased only at 10 MPa. Morphologically, matrix condensation occurred with increased IHP, concomitant with collagen expression. This study demonstrated that different levels of IHP differentially modulate hMSC chondrogenesis in the presence of TGF-beta3. The data suggest that tissue engineering of articular cartilage through application or recruitment of hMSCs can be facilitated by mechanical stimulation.

Adult↗

Gene regulation ex vivo within a wrap-around tendon.

This study tested the hypothesis that physiologic tendon loading modulates the fibrous connective tissue phenotype in undifferentiated skeletal cells. Type I collagen sponges containing human bone marrow stromal cells (MSCs) were implanted into the midsubstance of excised sheep patellar tendons. An ex vivo loading system was designed to cyclically stretch each tendon from 0 to 5% at 1.0 Hz. The MSC-sponge constructs were implanted into 2 tendon sites: the first site subjected to tension only and a second site located at an artificially created wrap-around region in which an additional compressive stress was generated transverse to the longitudinal axis of the tendon. The induced contact pressure at the wraparound site was 0.55 +/- 0.12 MPa, as quantified by pressure-sensitive film. An MSC-sponge construct was maintained free swelling in the same bath as an unloaded control. After 2 h of tendon stretching, the MSC-sponge constructs were harvested and real-time PCR was used to quantify Fos, Sox9, Cbfa1 (Runx2), and scleraxis mRNA expression as markers of skeletal differentiation. Two hours of mechanical loading distinctly altered MSC differentiation in the wrap-around region and the tensile-only region, as evidenced by differences in Fos and Sox9 mRNA expression. Expression of Fos mRNA was 13 and 52 times higher in the tensile-only and wrap-around regions, respectively, compared to the free-swelling controls. Expression of Sox9 mRNA was significantly higher (2.5-3 times) in MSCs from the wraparound region compared to those from the tensile-only region or in free-swelling controls. In contrast, expression levels for Cbfa1 did not differ among constructs. Scleraxis mRNA was not detected in any construct. This study demonstrates that the physiologic mechanical environment in the wrap-around regions of tendons provides stimuli for upregulating early response genes and transcription factors associated with chondrogenic differentiation. These differentiation responses begin within as little as 2 h after the onset of mechanical stimulation and may be the basis for the formation of fibrocartilage that is typically found in the wrap-around region of mature tendons in vivo.

Animals↗

Bone cement improves suture anchor fixation.

Suture anchor fixation failure can occur if the anchor pulls out of bone. We hypothesized that suture anchor fixation can be augmented with polymethylmethacrylate cement, and that polymethylmethacrylate can be used to improve fixation in a stripped anchor hole. Six matched cadaveric proximal humeri were used. On one side, suture anchors were placed and loaded to failure using a ramped cyclic loading protocol. The stripped anchor holes then were injected with approximately 1 cc polymethylmethacrylate, and anchors were replaced and tested again. In the contralateral humerus, polymethylmethacrylate was injected into anchor holes before anchor placement and testing. In unstripped anchors, polymethylmethacrylate increased the number of cycles to failure by 34% and failure load by 71% compared with anchors not augmented with polymethylmethacrylate. Polymethylmethacrylate haugmentation of stripped anchors increased the cycles to failure by 31% and failure load by 111% compared with unstripped uncemented anchors. No difference was found in cycles to failure or failure load between cemented stripped anchors and cemented unstripped anchors. Polymethylmethacrylate can be used to augment fixation, reducing the risk of anchor pull-out failure, regardless whether the suture anchor hole is stripped or unstripped.

Aged↗

Measurement of in vivo lumbar intervertebral disc pressure during spinal manipulation: a feasibility study.

This paper presents the first reported measurements of lumbar intervertebral disc pressure in vivo during spinal manipulation. A pressure transducer was inserted into the nucleus pulposus of one normal-appearing lumbar disc in an asymptomatic adult volunteer. Pressures were recorded during several body positions and maneuvers, then during spinal manipulation, and lastly during a repetition of the preintervention body positions. Baseline pressures in the prone and side-lying positions measured 110 kPa and 150 kPa, respectively. During the manipulation, pressure rose to a peak of 890 kPa over 250 ms. Immediately following, pressures in the prone and side-lying positions measured 150 kPa and 165 kPa, respectively. These data do not support the hypotheses that manipulation can reduce a herniation by decreasing intradiscal pressure, or cause a herniation by raising pressure to failure levels. Further work may lead to a better understanding of this treatment method.

Adult↗

The use of an interspinous implant in conjunction with a graded facetectomy procedure.

STUDY DESIGN: The range of motion (ROM) of lumbar cadaver spines was measured during flexion, extension, axial rotation, and lateral bending following graded facetectomies and implantation of an X STOP interspinous spacer implant. OBJECTIVE: The study was performed undertaken to understand better the influence of the interspinous spacer implant on the kinematics of the lumbar spine following graded facetectomies. SUMMARY OF THE BACKGROUND DATA: Lateral lumbar spinal stenosis is often treated with a unilateral or bilateral facetectomy procedure. Previous biomechanical research has shown that a facetectomy may increase the ROM during flexion and axial rotation. METHODS: Seven cadaver spines (L2-L5) were tested in flexion, extension, axial rotation, and lateral bending, and the individual ROM of each motion segment was measured. Specimens were tested intact and following 3 graded facetectomies (i.e., unilateral medial facetectomy [UMF], unilateral total facetectomy [UTF], and bilateral total facetectomy [BTF]), with and without the X STOP. RESULTS: A BTF caused a significant increase in ROM during flexion and axial rotation but not extension and lateral bending. The UMF and UTF did not affect the ROM during any of the 4 motions. The interspinous implant: (1) significantly decreased the flexion ROM for the intact, UMF, UTF, and BTF treatments; (2) significantly decreased the extension ROM for the intact, UMF, and BTF treatments but not the UTF (P < 0.13); (3) had no significant effect on the axial rotation ROM; and (4) significantly increased the lateral bending ROM for the UMF, UTF, and BTF treatments. CONCLUSIONS: The results suggest that the implant may be used in conjunction with a UMF or UTF. However, the X STOP should not be used in conjunction with BTF.

Biomechanical Phenomena↗

Insertion loads of the X STOP interspinous process distraction system designed to treat neurogenic intermittent claudication.

An interspinous process implant has been developed to treat patients suffering from neurogenic intermittent claudication secondary to lumbar spinal stenosis. As most patients who suffer from spinal stenosis are over the age of 50 and may have weaker bones, it is imperative to know how bone mineral density (BMD) correlates with lateral spinous process strength. The study was undertaken to characterize the lateral failure loads of the spinous process, correlate the failure loads to BMD, and compare the failure loads to the loads required to insert an interspinous process implant. Spinous process lateral failure loads were assessed, correlated to BMD, and compared to the loads required to insert an interspinous process implant. Mean spinous process failure loads were significantly greater than the lateral insertion load of the interspinous process implant. There was a significant relationship between the BMD and spinous process failure load. The technique used to insert the interspinous implant poses little risk to spinous process failure. There is ample margin of safety between the insertion loads and spinous process failure loads. The significant relationship between BMD and spinous process failure load suggests that patients with lower BMD must be approached with more caution during the implant insertion procedure.

Biomechanical Phenomena↗

The effect of an interspinous process implant on facet loading during extension.

STUDY DESIGN: Facet loading parameters of lumbar cadaver spines were measured during extension before and after placement of an interspinous process implant. OBJECTIVE: The study was undertaken to quantify the influence of an interspinous implant on facet loading at the implanted and adjacent levels during extension. SUMMARY OF BACKGROUND DATA: Facet loading is increased during extension and decreased during flexion. Previous studies have demonstrated that interspinous process decompression relieves disc pressure at the implanted level and does not alter disc pressure at the adjacent levels. Facet joints are believed to play a key role in back pain, especially in patients with collapsed discs and increased motion segment mobility resulting in increased facet loading. METHODS: Seven cadaver spines (L2-L5) were loaded to 15 Nm of extension and 700 N compression with and without an interspinous process implant (X STOP) placed between the L3-L4 spinous processes. Pressure-sensitive film was placed in the facet joints of the implanted and adjacent levels. After loading, the film was digitally analyzed for peak pressure, average pressure, contact area, and force. These values were compared between the intact and implanted specimens at the adjacent and implanted levels using a paired t test (P < 0.05). RESULTS: The implant significantly reduced the mean peak pressure, average pressure, contact area, and force at the implanted level. The mean peak pressure, average pressure, contact area, and force at the adjacent levels were not significantly different between the intact and implanted specimens with the exception of contact area at the L2-L3 level. CONCLUSIONS: Interspinous process decompression will unlikely cause adjacent level facet pain or accelerated facet joint degeneration. Furthermore, pain induced from pressure originating in the facets and/or posterior anulus of the lumbar spine may be relieved by interspinous pro-cess decompression. Clinical results from patients with a component of lower back pain suggest that this is a valid conclusion.

Cadaver↗

The treatment mechanism of an interspinous process implant for lumbar neurogenic intermittent claudication.

STUDY DESIGN: The spinal canal and neural foramina dimensions of cadaver lumbar spines were quantified during flexion and extension using magnetic resonance imaging before and after placement of an interspinous process implant. OBJECTIVE: To quantify the effect of the implant on the dimensions of the spinal canal and neural foramina during flexion and extension. SUMMARY OF THE BACKGROUND DATA: Lumbar neurogenic intermittent claudication symptoms are typically exacerbated during extension and relieved during flexion. It is understood that the dimensions of the spinal canal and neural foramen increase in flexion and decrease in extension. The authors hypothesized that an interspinous process implant would significantly prevent narrowing of the canal and foramina in extension and have no significant effect in flexion. METHODS: Eight L2-L5 specimens were positioned to 15 degrees of flexion and 15 degrees of extension using a positioning frame. Each specimen was magnetic resonance imaged with and without an interspinous implant (X STOP) placed between the L3-L4 spinous processes. Canal and foramina dimensions were compared between the intact and implanted specimens using a repeated measures analysis of variance with a level of significance of 0.05. RESULTS: In extension, the implant significantly increased the canal area by 18% (231-273 mm), the subarticular diameter by 50% (2.5-3.7 mm), the canal diameter by 10% (17.8-19.5 mm), the foraminal area by 25% (106-133 mm), and the foraminal width by 41% (3.4-4.8 mm). CONCLUSIONS: The results of this study show that the X STOP interspinous process implant prevents narrowing of the spinal canal and foramina in extension.

Cadaver↗

The monotonic and fatigue properties of osteoporotic thoracic vertebral bodies.

STUDY DESIGN: Measurement of the monotonic and fatigue properties of osteoporotic thoracic vertebral bodies. OBJECTIVES: To determine the loading values at which osteoporotic vertebral bodies are susceptible to failure. SUMMARY OF BACKGROUND DATA: Vertebral compression fractures are the most common osteoporotic fracture. Eighty-three percent of vertebral compression fractures are caused by moderate or less trauma, and there is not a specific traumatic event in 59% of these cases. Fatigue loading can lead to premature failure, although the relationship between loading and cycles to failure is not well established. METHODS: Eighteen osteoporotic thoracic vertebral bodies were tested in monotonic compression to determine the correlation between the bone mineral content and the ultimate compressive load. Seventeen osteoporotic thoracic vertebral bodies were cyclically loaded at varying percentages of the ultimate compressive load until failure to determine the relationship between loading and fatigue life. RESULTS: The bone mineral content was linearly correlated with ultimate compressive load. Based on our regression analysis, a 10% decrease in bone mineral content will lead to an approximate 10% decrease in ultimate compressive load. The percentage of ultimate compressive load was inversely correlated to the logarithm of cycles to failure, with specimens loaded at 60%, 70%, and 80% of ultimate compressive load lasting on average 5.6 x 10, 4.0 x 10, and 31 cycles to failure, respectively. CONCLUSIONS: The bone mineral content is a strong predictor of the ultimate compressive load, while the percentage of the ultimate compressive load is a strong predictor of the cycles to failure for osteoporotic thoracic vertebral bodies.

Adult↗

Capsaicin-sensitive sensory neurons contribute to the maintenance of trabecular bone integrity.

UNLABELLED: This investigation used capsaicin to selectively lesion unmyelinated sensory neurons in rats. Neuronal lesioning induced a loss of trabecular integrity, reduced bone mass and strength, and depleted neuropeptides in nerve and bone. These data suggest that capsaicin-sensitive sensory nerves contribute to trabecular bone integrity. INTRODUCTION: Familial dysautomia is an autosomal recessive disease in which patients suffer from unmyelinated sensory neuron loss, reduced BMD, and frequent fractures. It has been proposed that the loss of neurotransmitters synthesized by unmyelinated neurons adversely affects bone integrity in this hereditary syndrome. The purpose of this study was to determine whether small sensory neurons are required for the maintenance of bone integrity in rats. MATERIALS AND METHODS: Ten-month-old male Sprague-Dawley rats were treated with either capsaicin or vehicle. In vivo DXA scanning and micro CT scanning, and histomorphometry were used to evaluate BMD, structure, and cellular activity. Bone strength was measured in distal femoral sections. Body weight and gastrocnemius/soleus weights were measured and spontaneous locomotor activity was monitored. Peroneal nerve morphometry was evaluated using light and electron microscopy. Substance P and calcitonin gene-related peptide (CGRP) content in the sciatic nerve and proximal tibia were determined by enzyme immunoassay (EIA). Substance P signaling was measured using a sciatic nerve stimulation extravasation assay. RESULTS: Four weeks after capsaicin treatment, there was a loss of BMD in the metaphyses of the tibia and femur. In the proximal tibia, the osteoclast number and surface increased, osteoblast activity and bone formation were impaired, and trabecular bone volume and connectivity were diminished. There was also a loss of bone strength in the distal femur. No changes occurred in body weight, 24-h grid-crossing activity, weight bearing, or muscle mass after capsaicin treatment, indicating that skeletal unloading did not contribute to the loss of bone integrity. Capsaicin treatment destroyed 57% of the unmyelinated sensory axons, reduced the substance P and CGRP content in the sciatic nerve and proximal tibia, and inhibited neurogenic extravasation. CONCLUSION: These results support the hypothesis that capsaicin-sensitive sensory neurons contribute to the maintenance of trabecular bone integrity. Capsaicin-sensitive neurons have efferent functions in the tissues they innervate, effects mediated by transmitters released from the peripheral nerve terminals. We postulate that the deleterious effects of capsaicin treatment on trabecular bone are mediated by reductions in local neurotransmitter content and release.

Absorptiometry, Photon↗

Mechanobiology of mandibular distraction osteogenesis: experimental analyses with a rat model.

We analyzed mechanobiological influences on successful distraction osteogenesis (DO). Mandibular distraction surgeries were performed on 15 adult male Sprague-Dawley rats. Animals underwent gradual distraction (GD), progressive lengthening by small increments (5-day latency followed by 0.25 mm distractions twice daily for 8 days followed by 28-day maturation period). Distracted hemimandibles were harvested on postoperative days (POD) 5, 7, 10, 13, and 41. Load-displacement curves were then recorded for ex vivo distractions of 0.25 mm and stresses determined. Histologically, new bone formation appeared in GD specimens on distraction day 2 (POD 7), filling 50-60% of the gap by distraction day 8 (POD 13), with nearly complete bony bridging at end maturation (POD 41). Average tensile strains imposed by each incremental distraction ranged from approximately 10% to 12.5% during distraction days 2-8 and were associated with bone apposition rates of about 260 microm/day. Because this GD protocol was previously determined to be optimal for DO, we conclude that strains within this range provide an excellent environment for de novo bone apposition. Distraction caused tissue damage in distraction day 2, 5, and 8 specimens as evidenced by distinct drops in the load/displacement curves. Taken together, our interpretation of these data is that daily distractions cause daily tissue damage which triggers new mesenchymal tissue formation.

Animals↗

The effects of an interspinous implant on the kinematics of the instrumented and adjacent levels in the lumbar spine.

STUDY DESIGN: Measurement of the kinematics of the lumbar spine after insertion of an interspinous spacer in vitro. OBJECTIVES: To understand the kinematics of the instrumented and adjacent levels due to the insertion of this interspinous implant. SUMMARY OF BACKGROUND DATA: An interspinous spacer (X Stop, SFMT, Concord, California) has been developed to treat neurogenic intermittent claudication by placing the stenotic segment in slight flexion and preventing extension. This restriction of motion by the interspinous implant may affect the kinematics of levels adjacent to the instrumented level. METHODS: Seven lumbar spines (L2-L5) were tested in flexion-extension, lateral bending, and axial rotation. Images were taken during each test to determine the kinematics of each motion segment. The interspinous implant was placed at the L3-L4 level, and the test protocol was repeated. RESULTS: The flexion-extension range of motion was significantly reduced at the instrumented level. Axial rotation and lateral bending ranges of motion were not affected at the instrumented level. The range of motion in flexion-extension, axial rotation, and lateral bending at the adjacent segments was not significantly affected by the implant. CONCLUSIONS: The implant does not significantly alter the kinematics of the motion segments adjacent to the instrumented level.

Adolescent↗

The effects of an interspinous implant on intervertebral disc pressures.

STUDY DESIGN: Measurement of intradiscal pressure was performed after placement of an interspinous implant in a cadaver model. OBJECTIVE: To understand the likelihood of accelerated adjacent-level disc degeneration as a result of the implant. SUMMARY OF BACKGROUND DATA: An interspinous implant has been developed to treat lumbar neurogenic claudication secondary to spinal stenosis that places the stenotic segment in slight flexion and prevents extension. Previous biomechanical studies demonstrated that fusing one level may significantly increase the intradiscal pressures at adjacent levels. Moreover, clinical studies have reported an increased incidence of adjacent-level degeneration after lumbar spinal fusion. METHODS: Eight cadaver lumbar specimens (L2-L5) were loaded in flexion, neutral, and extension. A pressure transducer measured intradiscal pressure and annular stresses during each of the three positions at each of the three disc levels. An appropriately sized implant was placed at L3-L4, and the pressure measurements were repeated. RESULTS: The pressures at the adjacent discs were not significantly affected by the interspinous implant insertion. There was a significant decrease in intradiscal pressure at the L3-L4 disc in the posterior annulus and nucleus in the neutral and extended positions. CONCLUSIONS: The implant does not significantly change the intradiscal pressures at the adjacent levels, yet it significantly unloads the intervertebral disc at the instrumented level in the neutral and extended positions. On the basis of the current findings, it does not appear that the implant causes accelerated disc degeneration at the adjacent levels.

Aged↗

Effects of creep and cyclic loading on the mechanical properties and failure of human Achilles tendons.

The Achilles tendon is one of the most frequently injured tendons in humans, and yet the mechanisms underlying its injury are not well understood. This study examines the ex vivo mechanical behavior of excised human Achilles tendons to elucidate the relationships between mechanical loading and Achilles tendon injury. Eighteen tendons underwent creep testing at constant stresses from 35 to 75 MPa. Another 25 tendons underwent sinusoidal cyclic loading at 1 Hz between a minimum stress of 10 MPa and maximum stresses of 30-80 MPa. For the creep specimens, there was no significant relationship between applied stress and time to failure, but time to failure decreased exponentially with increasing initial strain (strain when target stress is first reached) and decreasing failure strain. For the cyclically loaded specimens, secant modulus decreased and cyclic energy dissipation increased over time. Time and cycles to failure decreased exponentially with increasing applied stress, increasing initial strain (peak strain from first loading cycle), and decreasing failure strain. For both creep and cyclic loading, initial strain was the best predictor of time or cycles to failure, supporting the hypothesis that strain is the primary mechanical parameter governing tendon damage accumulation and injury. The cyclically loaded specimens failed faster than would be expected if only time-dependent damage occurred, suggesting that repetitive loading also contributes to Achilles tendon injuries.

Achilles Tendon↗

Posterior stabilization at the cervicothoracic junction: a biomechanical study.

STUDY DESIGN: This study biomechanically evaluated three fixation devices for stability with posterior two- and three-column injuries. OBJECTIVES: To find an effective means of posteriorly stabilizing injuries at the cervicothoracic junction. SUMMARY OF BACKGROUND DATA: The cervicothoracic spine is complex anatomically and has been a difficult challenge in approach and stabilization of traumatic and degenerative disorders. METHODS: Twenty-one human cadaveric spines (C3-T3) were loaded in flexion, extension, lateral bending, and axial torsion. A posterior two-column injury was created at C7-T1. One of three posterior fixation systems was applied (two rod-screw systems, one plate-screw system, all with screws at C5, C6 and T1, T2). The spines were tested again. A three-column injury was created by transecting the remaining anterior structures; the spines were tested a final time. RESULTS: In flexion-extension, there were no significant differences in stiffness between intact and instrumented two-column injury specimens for all systems; the instrumented three-column injury was significantly (P < 0.05) less stiff than intact specimens in extension. Ranges of motion and neutral zones decreased from intact to instrumented two-column injuries and increased from intact to three-column constructs. In lateral bending and axial rotation, all systems were stiffer than intact spines for both injuries; ranges of motion and neutral zones were reduced for both injuries compared with intact specimens. CONCLUSION: All three systems stabilize the cervicothoracic junction with a posterior two-column injury in flexion-extension, lateral bending, and axial rotation; none was adequate for a three-column injury, particularly in extension. A three-column injury at this level would warrant supplemental anterior fixation.

Adult↗