Chloride selective calix[4]arene optical sensor combining urea functionality with pyrene excimer transduction.

A neutral 2-site chloride selective compound has been developed (3), based on a 1,3-alternate tetrasubstituted calix[4]arene providing a preorganized supramolecular scaffold. The resultant supramolecular cavity is among the first to combine urea functional groups bridged with single methylene spacers to pyrene moieties. It combines a naturally and synthetically proven H-bonding system with the elegant ratiometric fluorescent signaling properties of an intramolecular pyrene excimer system, triggered by conformational changes upon anion coordination. The excimer emission of 3 is quenched, with a simultaneous rise in the monomer emission solely by the chloride anion among a wide variety of anions tested. 3 has an association constant of 2.4 x 10(4) M(-1) with chloride. The suitability and advantages of ratiometric optical sensor compounds like 3 for use in practical sensor devices is discussed. 3 has an LOD of 8 x 10(-6) M with chloride in acetonitrile-chloroform (95:5 v/v). A dynamic fluorescence study revealed a response time of < 3 s. A recently developed and simple HPLC-based purification method complimented conventional organic work up methods to yield pure product.

Journal Article↗

Novel integrated paired emitter-detector diode (PEDD) as a miniaturized photometric detector in HPLC.

A novel low power, low cost, highly sensitive, miniaturized light emitting diode (LED) based flow detector has been used as optical detector for the detection of sample components in high performance liquid chromatography (HPLC). This colorimetric detector employs two LEDs, one operating in normal mode as a light source and the other is reverse biased to work as a light detector. Instead of measuring the photocurrent directly, a simple timer circuit is used to measure the time taken for the photocurrent generated by the emitter LED (lambda(max) 500 nm) to discharge the detector LED (lambda(max) 621 nm) from 5 V (logic 1) to 1.7 V (logic 0) to give digital output directly without using an A/D converter. Employing a post-column reagent method, a Nucleosil 100-7 column (functionalized with iminodiacetic acid (IDA) groups) was used to separate a mixture of transition metal complexes, manganese(II) and cobalt(II) in 4-(2-pyridylazo)-resorcinol (PAR). All optical measurements were taken by using both the in-built HPLC variable wavelength detector and the proposed paired-emitter-detector-diode (PEDD) optical detector configured in-line for data comparison. The concentration range investigated using the PEDD was found to give a linear response to the Mn(II) and Co(II) PAR complexes. The effects of flow rate and emitter LED light source intensity were investigated. Under optimised conditions the PEDD detector offered a linear range of 0.9-100 microM and LOD of 0.09 microM for Mn-PAR complex. A linear range of 0.2-100 microM and LOD of 0.09 microM for Co-PAR complex was achieved.

Journal Article↗

Fast electrophoretic analysis of individual mitochondria using microchip capillary electrophoresis with laser induced fluorescence detection.

The analysis of mitochondria by capillary electrophoresis usually takes longer than 20 min per replicate which may compromise the quality of the mitochondria due to degradation. In addition, low sample consumption may be beneficial in the analysis of rare or difficult samples. In this report, we demonstrate the ability to analyze individual mitochondrial events in picoliter-volume samples (approximately 80 pL) taken from a bovine liver preparation using microchip capillary electrophoresis with laser-induced fluorescence detection (micro-chip CE-LIF). Using a commercial "double-T" glass microchip, the sample was electrokinetically loaded in the "double-T" intersection and then subjected to electrophoretic separation along the main separation channel. In order to decrease interactions of mitochondria with channel walls during the analysis, poly(vinyl alcohol) was used as a dynamic coating. This procedure eliminates the need for complicated covalent surface modifications within the channels that were previously used in capillary electrophoresis methods. For analysis, mitochondria, isolated from bovine liver tissue, were selectively labelled using 10-nonyl acridine orange (NAO). The results consist of electropherograms where each mitochondrial event is a narrow spike (240 +/- 44 ms). While the spike intensity is representative of its NAO content, its migration time is used to calculate and describe its electrophoretic mobility, which is a property still largely unexplored for intracellular organelles. The five-fold decrease in separation time (4 min for microchip versus 20 min for capillary electrophoresis) makes microchip electrophoretic separations of organelles a faster, sensitive, low-sample volume alternative for the characterization of individual organelle properties and for investigations of subcellular heterogeneity.

Animals↗

Chemo/bio-sensor networks.

The concept of wireless sensor networks conjures up images of a world of ubiquitous sensing, but it requires a massive increase in the number of sensors available. Although there has been considerable activity in transducer-based 'sensor nets', there have been virtually no corresponding deployments of chemical- or biological-sensing networks - considerable advances in materials science are needed before these can be used on a large scale.

Journal Article↗

Initial development and testing of a novel foam-based pressure sensor for wearable sensing.

BACKGROUND: This paper provides an overview of initial research conducted in the development of pressure-sensitive foam and its application in wearable sensing. The foam sensor is composed of polypyrrole-coated polyurethane foam, which exhibits a piezo-resistive reaction when exposed to electrical current. The use of this polymer-coated foam is attractive for wearable sensing due to the sensor's retention of desirable mechanical properties similar to those exhibited by textile structures. METHODS: The development of the foam sensor is described, as well as the development of a prototype sensing garment with sensors in several areas on the torso to measure breathing, shoulder movement, neck movement, and scapula pressure. Sensor properties were characterized, and data from pilot tests was examined visually. RESULTS: The foam exhibits a positive linear conductance response to increased pressure. Torso tests show that it responds in a predictable and measurable manner to breathing, shoulder movement, neck movement, and scapula pressure. CONCLUSION: The polypyrrole foam shows considerable promise as a sensor for medical, wearable, and ubiquitous computing applications. Further investigation of the foam's consistency of response, durability over time, and specificity of response is necessary.

Journal Article↗

Wearable Sensors? What is there to sense?

This paper provides an overview of research conducted in the development of ambulatory devices for wearable sensing applications. Two configurations of wearable sensing are shown, the first a wearable chemosensor in a wrist-watch configuration, and the second a textile with an integrated foam sensor. The foam sensor is composed of polypyrrole-coated polyurethane foam, which exhibits a piezo-resistive response when exposed to electrical current. The potential of wearable sensing is discussed using these examples to illustrate the relevant concerns.

Biomedical Technology↗

Development of a biosensor for endocrine disrupting compounds based on tyrosinase entrapped within a poly(thionine) film.

Preparation of semiconducting films by electropolymerisation of a monomer which is itself a redox mediator is an attractive and simple method for biosensor fabrication. A polymeric film of the redox dye thionine (phenothiazine) enables the stable immobilisation of polyphenol oxidase (tyrosinase) while acting as mediator for the enzymatic process. The immobilisation method is based on an inner crosslinked tyrosinase layer which contains thionine with an electropolymerised film of poly(thionine) on top. This method gave the most stable redox couple for poly(thionine) and exhibited the greatest response stability. The sensor was tested using a range of synthetic oestrogens and phenolic compounds, which are suspected endocrine disruptors/oestrogen mimics. The device responded well to all compounds tested with limits of detection ranging from 1 to 23 microM (based on three times S/N ratio). The tyrosinase/poly(thionine) electrode response to phenol was 3 orders of magnitude greater than the unmediated response in the absence of poly(thionine).

Biosensing Techniques↗

CO2 laser microfabrication of an integrated polymer microfluidic manifold for the determination of phosphorus.

A simple colorimetric technique is implemented in a polymer microfluidic manifold. The simple chemistry aids an uncomplicated microchannel design, which is fabricated by CO(2) laser ablation. Issues such as bonding of multiple layers, alignment of micro-fabricated structures and integration of optical components are addressed. A demonstration of a stopped flow regime in the microfluidic manifold is also presented.

Journal Article↗

Tuning and enhancing enantioselective quenching of calixarene hosts by chiral guest amines.

The synthesis of a propranolol amide derivative of p-allylcalix[4]arene is described, which has been designed to behave as a molecular sensor capable of distinguishing chiral amines on the basis of their shape and chirality. This molecule can discriminate between the enantiomers of phenylalaninol through the quenching of the fluorescence emission in methanol in contrast to an (S)-dinaphthylprolinol calix[4]arene derivative, which can discriminate between the enantiomers of phenylglycinol, but not phenylalaninol. The separation between the naphthyl fluorophores and the hydrogen-bonding sites within the chiral cavity can be tuned to recognize guest amines with similar separation between aryl groups and hydrogen-bonding sites. The formation of metal ion complexes of the p-allylcalix[4]arene propranolol amide derivative is shown to induce a more regular and rigid cone conformation in the calix[4]arene macrocycle, which generates a significant enhancement in the observed enantiomeric discrimination.

Amines↗

A prototype industrial sensing system for phosphorus based on micro system technology.

Progress in the development of a miniaturised microfluidic instrument for monitoring phosphorus in natural waters and wastewater is presented. The yellow colorimetric method for phosphate analysis has been transferred to a microfluidic chip configuration This simple method employs one reagent mixed in a 1:1 ratio with a sample to produce a yellow colour absorbing strongly below 400 nm. A stopped flow approach is used which, together with the very rapid kinetics and simple reagent stream, enables a very uncomplicated microfluidic manifold design to be adopted. The working wavelength is 380 nm to coincide with the peak output of a recently developed UV-LED narrow bandwidth light source. The limit of detection for the yellow method is 0.2 ppm with a dynamic linear range from 0-50 ppm possible. The reaction time at room temperature is less than 3 min, which means that up to 20 samples per hour can be analysed.

Journal Article↗

Analysis of river water samples utilising a prototype industrial sensing system for phosphorus based on micro-system technology.

The application of a phosphorus monitoring device based on microsystems technology (MST) to the analysis of river water is presented. An alternative to the standard molybdenum blue method known as the yellow vanadomolybdophosphoric acid method has been very effectively implemented. The method is simple, a reagent and sample are mixed in a 1:1 ratio forming a yellow complex that absorbs strongly below 400 nm in the UV spectrum. The kinetics of the reaction are rapid and sample turnaround is typically 3 min at room temperature. Therefore a very uncomplicated microfluidic design can be adopted. The working wavelength was chosen as 380 nm to coincide with the peak output of a UV-LED narrow bandwidth light source recently developed by Nichia. The limit of detection for the yellow method in the microfluidic system is 0.2 ppm with a dynamic linear range from 0-50 ppm. The method was applied to a measurement of phosphorus in a local river at specific sampling points along its course.

Absorption↗

Monitoring of headspace total volatile basic nitrogen from selected fish species using reflectance spectroscopic measurements of pH sensitive films.

The release of amines from decomposing fish such as trimethylamine (TMA), dimethylamine (DMA) and ammonia, collectively known as total volatile basic nitrogen (TVB-N), are in high enough concentrations in headspace to be monitored by a colour change in a pH-sensitive sensor. A method developed here uses a pH indicator dye physically trapped in a cellulose polymer film to respond to the headspace TVB-N released from selected fish species during spoilage. Two species were selected for analysis on the basis of economic importance and the levels of volatile amines released were followed with time using uv/vis reflectance spectroscopic measurements. The results show that there is a significant increase in the TVB-N content in the headspace of fish samples after an incubation period of 8-12 h for cod and 12-15 h for orange roughy.

Journal Article↗