Validity of pachymetric measurements by manipulating the acoustic factor of Orbscan II.

PURPOSE: To assess the validity of pachymetric measurements by examining the constancy of the acoustic factor (AF) of the Orbscan II (Orbtek, Bausch & Lomb, Rochester, NY) after overnight rigid gas-permeable (RGP) contact lens wear. METHODS: Twenty participants wore CRT (Paragon Vision Sciences, Mesa, AZ) HDS 100 contact lenses on one eye and control lenses on the contralateral eye for one night while sleeping. Another 24 participants wore CRT lenses on both eyes for one night. Central corneal thickness was measured using optical coherence tomography and Orbscan II on the night before lens use, immediately after lens removal on the following morning, and 1, 3, 6, and 12 hours later. By using optical coherence tomography as a reference, the adjusted AF was calculated by using a least squares method over time. RESULTS: The adjusted AF depended on the corneal thickness in normally hydrated corneas. The adjusted AF and the percentage change of the adjusted AF varied before and after overnight lens wear. There was a strong and significant correlation between the corneal swelling and the percentage change of the adjusted AF (all r at least 0.91, P<0.05). CONCLUSIONS: The adjusted AF is a variable, not a constant. The AF is a function of the corneal thickness and its alteration with, for example, corneal swelling. The validity of the adjusted Orbscan II pachymetric measures using a single AF is untenable.

Adult↗

Overnight corneal swelling with silicone hydrogel contact lenses with high oxygen transmissibility.

PURPOSE: To compare central corneal swelling after 8 hours of sleep in eyes wearing 2 different silicone hydrogel lenses with high oxygen transmissibility. METHODS: Twenty neophyte subjects were randomly assigned to wear a comfilcon A lens (CooperVision Inc) in one eye and a lotrafilcon A lens (CIBA Vision) in the contralateral eye for an 8-hour overnight period. The study was repeated with another 20 neophyte subjects wearing comfilcon A in one eye only and no lens in the contralateral control eye. Central corneal thickness was measured with optical pachometry before lens insertion, immediately after lens removal on waking, at 20 and 40 minutes, 1 hour, 2 hours and 3 hours. RESULTS: There was no significant difference between the amount of overnight central corneal swelling induced by the 2 lenses (4.1% +/- 1.9% with comfilcon A vs. 4.0% +/- 1.7% with lotrafilcon A; P>0.05). The swelling of the comfilcon A lens-wearing eyes was significantly higher than that found in the non-lens-wearing contralateral eyes (4.5% +/- 2.1% vs. 3.0% +/- 1.7%; P<0.05). CONCLUSIONS: The same amount of overnight corneal swelling was induced by the 2 study lenses. The higher overnight swelling observed with the comfilcon A lenses compared to the non-lens-wearing eyes is similar to that reported in the literature for studies using lotrafilcon A lenses.

Adult↗

Objective and subjective responses in patients refitted to daily-wear silicone hydrogel contact lenses.

PURPOSE: Silicone hydrogel (SiH) lenses offer many physiological advantages for daily wear (DW) in addition to the continuous-wear modality for which they were originally developed. The purpose of this study was to investigate the clinical performance and physiological responses in a group of successful long-term wearers of conventional hydrogel lenses when refitted with DW SiH contact lenses. METHODS: Eighty-seven successful soft lens wearers (8.4+/-4.7 years of prior lens wear) participated in this study. Bulbar and limbal hyperemia were subjectively graded and digitally photographed for subsequent masked objective evaluation. Subjective symptoms were scored using visual analog scales. In addition, refractive error, corneal curvature, and corneal thickness were measured. All subjects were refitted with Focus Night & Day (lotrafilcon A) SiH lenses; however, to reduce the potential for bias, they were informed that they were being randomly assigned to wear either low oxygen permeability (Dk) lenses or high Dk SiH lenses and were "masked" as to their lens assignment. Subjects returned after 1 week, 1 month, and 2 months of DW, at which time all gradings, photographs, and measurements were repeated. End-of-day subjective symptoms were also graded periodically during the study. RESULTS: Ninety-three percent of subjects were successfully refitted. Both objective and subjective evaluations showed that bulbar and limbal hyperemia decreased significantly in all quadrants during the study (p<0.001), particularly for those subjects with greater baseline hyperemia (p<0.001). Subjects reported a concurrent reduction in end-of-day dryness and improved end-of-day comfort compared with their habitual lenses (p<0.001). No significant changes in refractive error, tarsal papillary response, corneal curvature, or corneal thickness were found during the study. CONCLUSIONS: Hyperemia in contact lens wearers may be attributed to a number of factors, including hypoxia. Refitting existing low Dk lens wearers with SiH lenses on a DW basis can result in a decrease in hyperemia, which may be significant for some subjects and also results in improvements in symptoms of dryness and discomfort.

Adolescent↗

Corneal oxygen deficiency.

OBJECTIVES: To compare the ocular effects of low Dk hydrogel and high Dk silicone hydrogel contact lenses. METHODS: A review of recent literature was conducted to determine the effects of wearing low and high Dk soft lenses on corneal swelling, vascular response, refractive error and the corneal epithelium. RESULTS: High Dk silicone hydrogel contact lenses became available for research and clinical practice almost 10 and 5 years ago respectively. During that time many studies have been conducted and it has been demonstrated repeatedly how much improvement there has been to the physiological response of the eye particularly when wearing the lenses on an overnight basis. CONCLUSIONS: Although silicone hydrogels only constitute about 2% of current wearers, their positive effects on the eye compared with low Dk hydrogel lenses should make them the most dominant lenses in the near future.

Bacterial Infections↗

A review of the Holden-Mertz criteria for critical oxygen transmission.

PURPOSE: Holden and Mertz established the foundations for the new generation of silicone hydrogel contact lenses for daily and extended wear in 1984. Absence of lens-induced corneal swelling was their premise and although this was possible with daily wear, the goal with extended wear seemed almost impossible because of the limitation of hydrogel materials. Experience with extended and daily wear of disposable contact lenses during the last 2 decades and, more recently, with silicone hydrogels has led to the reconsideration of the validity of the findings of Holden and Mertz. RESULTS: A pivotal influence on the Holden and Mertz critical Dk/t value for closed-eye lens wear was exerted by two numbers: the no-lens wear corneal edema level (4%) and the silicone lens data point (Dk/t of 182x10, closed-eye edema level of 2.6%). Subsequent publications appear to give a more accurate assessment of the no-lens closed-eye corneal edema level, and there are also more recent measurements of silicone hydrogel lens Dk/t and corneal edema responses. CONCLUSIONS: It now appears that the Holden and Mertz criteria for extended-wear critical Dk/t should be revised upwards to at least 125x10.

Contact Lenses, Extended-Wear↗

Reduction of myopia from corneal refractive therapy.

PURPOSE: : The purpose of the study was to monitor the efficacy of corneal refractive therapy (CRT) lenses to reduce myopia over a 4-week period. Refractive error, keratometry, high and low contrast acuity, and subjective vision after 28 days of using CRT contact lenses were measured. METHODS: : Twenty-three myopes wore CRT HDS lenses, Dk = 100. The Nikon autokefractor/keratometer was used to measure the refractive error and keratometric changes. Visual acuity was measured using computerized high and low contrast charts and the subjects completed visual analog scales characterizing their vision on a daily basis. Measurements were performed at baseline (before lens insertion before sleep), immediately after lens removal the next morning and at 1, 3, 7, and 14 hours after eye opening. Measurements were made on the days following 1, 4, 10, and 28 nights of lens wear. After 72 hours of no lens wear, these parameters were again measured to assess corneal recovery. RESULTS: : The pretreatment manifest refraction (mean of OD and OS +/- standard deviation [SD]) was -2.72 DS +/- 1.06 and -0.55 DC +/- 0.40. Myopic spherical equivalent refractive error (+/- SD) decreased by 1.30 DS +/- 0.53 (range 0-3 D) immediately after lens removal on day 1 and by 2.59 DS +/- 0.77 by day 28 (range 1.25-3.88 D). The cylinder remained unchanged. Uncorrected visual acuity improved by 5 lines after one night and reached 0.00 LogMAR (6/6) by day 4. Visual acuity was maintained throughout the day by day 10. The day and time effect of the spherical equivalent change and the central corneal radius of curvature were statistically significant (p < 0.01) up to day 10 and remained the same until day 28. Central (autokeratometer) Ks flattened by 1.28 D +/- 1.35 after one night and 2.33 D +/- 1.30 by day 28. The subjective vision improved significantly from day 1 to day 28 (p < 0.01) and was maintained throughout the day from day 4 to day 28 (p < 0.01). All measures did not recover completely to baseline after 72 hours of no lens wear. CONCLUSIONS: : CRT lenses significantly reduced myopia, improved visual acuity and subjective vision, and flattened central corneal curvature. Maximal effect was achieved after 10 days and was maintained for the rest of the study period.

Adult↗

Tear turnover rate is reduced in patients with symptomatic dry eye.

PURPOSE: Tear turnover rate (TTR) is defined as the percent decrease of fluorescein concentration in the tears per minute after the instillation of fluorescein. The purpose of this study was to examine differences in TTR in a sample with symptoms of dry eye and an asymptomatic control sample using the Fluorotron Master Fluorophotometer. METHODS: TTR was measured using the OcuMetrics Fluorotron Master. It measures the decay of the fluorescence of high molecular weight fluorescein FITC Dextran instilled into the tear film. Twenty participants (post-menopausal women) were enrolled in the study (10 asymptomatic (age 64.7 +/- 6.99) and 10 symptomatic (age 61.5 +/- 7.98)). Participants were grouped according to either a positive (symptomatic) or negative (asymptomatic) McMonnies Dry Eye Questionnaire, i.e., an indication of self-reported ocular dryness and the use of rewetting/lubricating drops (questions 4 and 5). TTR was measured in the afternoon only. Measurements were made on the right eye with a controlled blink rate (15 blinks/min), for up to 30 min, post-insertion of 2 microl of 2% FITC Dextran (MW 9500). The scan data were used to construct a graph of log fluorescein concentration (ng/ml) as a function of time and the TTR calculated (%/ min = (1- ln (slope)) x 100). RESULTS: There was a significant difference in the TTR between symptomatic and asymptomatic subjects. Mean TTR (symptomatic) was 4.89 +/-2.74%/min (range, 2.04-11.81) and mean TTR (asymptomatic) was 11.85 +/- 3.31%/min (range, 5.76-16.45) (P < 0.0001). CONCLUSIONS: Fluorophotometry may be used to demonstrate differences in the tear turnover rate in this post-menopausal group of women, with patients experiencing symptoms of dry eye having a lower TTR than the normals.

Journal Article↗

Contact lens-induced corneal swelling and surface changes measured with the Orbscan II corneal topographer.

PURPOSE: The purpose of this study was to measure central and topographical corneal swelling in response to contact lens wear and eye closure, to determine whether the swelling induced by soft and polymethyl methacrylate (PMMA) lenses is different, and to determine whether the anterior and/or posterior corneal shape alters with corneal swelling. METHODS: An Orbscan II corneal topographer was used to measure corneal swelling and the shape of the anterior and posterior corneal surfaces of 16 neophytes before and after wearing soft and PMMA contact lenses with near-zero oxygen transmissibility. The lens-wearing eye was patched for 3 h. RESULTS: The mean 15.1% +/- 3.8% (+/- SD) central corneal swelling with soft lenses was significantly >12.6% +/- 4.1% with PMMA lenses. Topographical corneal swelling was significantly greater with soft vs. PMMA lenses. However, the difference between central and peripheral corneal swelling was much greater with PMMA lenses. With both lenses, the cornea swelled significantly more in the center than the periphery. The anterior best-fit sphere radius remained unchanged in response to soft lenses (0.00 +/- 0.04 mm) and steepened slightly but significantly with PMMA lenses (-0.04 +/- 0.05 mm). The posterior best-fit sphere radius flattened significantly with both lenses (0.12 +/- 0.07 mm with soft and 0.14 +/- 0.08 mm with PMMA lenses). CONCLUSIONS: Corneal swelling (greater centrally than peripherally) flattens the posterior surface of the cornea and is independent of lens type. Although the anterior best-fit sphere radius steepened with PMMA, the magnitude is probably clinically unimportant. Both lens types produced greater central vs. peripheral corneal swelling. However, the soft lens induced significantly greater overall swelling than PMMA. Because their oxygen transmission was the same, these results suggest that there is lateral diffusion of oxygen from the peripheral area of the cornea (that is not covered by the lens) toward the center.

Adult↗

Corneal and epithelial thickness changes after 4 weeks of overnight corneal refractive therapy lens wear, measured with optical coherence tomography.

PURPOSE: To investigate thickness changes of the total cornea and epithelium across the horizontal corneal meridian after 4 weeks of overnight corneal refractive therapy (CRT) rigid contact lens (Paragon Vision Sciences, Mesa, AZ) wear. METHODS: Thirty subjects were fitted with CRT contact lenses (Dk/t = 67), which were worn overnight for 4 weeks. Corneal thickness was measured at nine locations along the horizontal meridian by using optical coherence tomography (OCT) before lens insertion in the evening. Corneal thickness was measured the next morning immediately after lens removal and 1, 3, 7, and 14 hours later. This was repeated on days 4, 10, and 28 of the study and then 3 days after discontinuing lens wear. RESULTS: Twenty-three subjects completed the study. At lens removal on day 1, the central and paracentral cornea swelled by 4.9% and 6.2%, respectively (both P = 0.000). The central epithelium thinned by 7.3%, and the mid peripheral epithelium thickened by 13% (both P = 0.000). Corneal swelling recovered throughout the day, with most of the deswelling taking place within the first 3 hours after lens removal. Maximal central epithelial thinning reached 13.5% by day 4. Three days after the study completion, corneal and epithelial thickness had recovered to baseline values. CONCLUSIONS: This study shows that CRT lenses induce differential overnight swelling across the cornea, with rapid deswelling during the day. Central epithelial thinning and paracentral thickening occurs, with recovery 3 days after discontinuation of lens wear.

Adult↗

Objective measurements of corneal light-backscatter during corneal swelling, by optical coherence tomography.

PURPOSE: To demonstrate that corneal light-backscatter can be measured objectively during corneal swelling by optical coherence tomography (OCT). METHODS: One eye (randomly selected) of 20 non-contact-lens wearers (10 men and 10 women; mean age, 35.6 +/- 9.6 years) was patched during 3 hours of soft contact lens (SCL) wear. The contralateral eye acted as the control. Central corneal images were captured before and after SCL wear at 20-minute intervals over 100 minutes using optical coherence tomography (OCT) to obtain corneal thickness and light-backscatter profiles. OCT backscattered light of the epithelial layer (decided by the thickness measurements) and 10 equally divided layers of the remaining cornea were analyzed with a custom software program. Two baseline measurements were taken at different visits before lens wear to test the repeatability of light-backscatter measurements. RESULTS: From two baseline measurements, repeated measurements showed good repeatability of normalized backscatter results. Immediately after contact lens removal, total central corneal thickness increased significantly by 13.8% +/- 2.3% (mean +/- SD) compared with baseline (P = 0.0001, paired t-test) and then decreased during the deswelling course. Corneal backscattered light changed significantly (repeated-measures ANOVA [Re-ANOVA]: F((50, 950)) = 2.22, P = 0.0001) after lens wear, and a significant increase in backscatter was found in the epithelial layer (36.4%) and the most posterior corneal layer (35.6%) immediately after lens removal (post hoc test, P = 0.005). There was a strong correlation (r = 0.9375, P < 0.05) between the change in backscatter and corneal swelling during the deswelling period. The backscatter recovery rate was approximately the same for both epithelial and posterior layers after lens removal. CONCLUSIONS: Light-backscattering analysis with OCT seems to be a promising and repeatable method of objectively measuring corneal backscatter. This study has demonstrated that corneal backscattered light increased in the anterior and posterior layers of the cornea during corneal swelling induced by contact lens wear and eye closure.

Adult↗

Diurnal variation of corneal sensitivity and thickness.

PURPOSE: To measure the diurnal variation of central corneal sensitivity and thickness over 24 hours. METHODS: A noncontact pneumatic esthesiometer to measure central corneal sensitivity and an optical pachymeter to measure central corneal thickness were used on 20 noncontact lens wearers. These measurements were performed at 22:00 before 8 hours of sleep and on the following day on eye opening and at hourly intervals between 7:00 and 22:00. RESULTS: Central corneal sensitivity varied by 35% over the 24 hours. Sensitivity was significantly lower by 17.1 +/- 2.1% on eye opening and recovered to the level of the previous night after 4 hours. Corneal sensitivity continued to increase throughout the day but was not significantly higher. Central corneal thickness varied by 3.9% over the 24 hours. The mean overnight corneal swelling was 2.9 +/- 0.31%, and 2 hours after eye opening, the cornea had deswelled to the same thickness as the previous night. The cornea thinned further throughout the day, but there were no statistically significant differences between the values after 14:00. There was a high correlation between corneal sensitivity and thickness over time (r = 0.8; p < 0.05). DISCUSSION: Corneal sensitivity correlated with corneal thickness: both were higher on awakening and then decreased and remained below the levels measured the previous night. This may be due to physiological and/or environmental factors. The lack of significant differences between the values after 14:00 suggests that baseline may be measured at any time from 7 hours after eye opening.

Adult↗

Dryness and discomfort with silicone hydrogel contact lenses.

PURPOSE: The purpose of this study was to determine whether symptoms of dryness and discomfort are experienced differently with silicone hydrogel lenses compared to conventional hydrogels, in symptomatic and asymptomatic subjects. METHODS: Thirty-nine symptomatic and asymptomatic subjects wore four types of lenses: Focus NIGHT & DAY (CIBA Vision), Focus DAILIES (CIBA Vision), ACUVUE 2 (Johnson & Johnson Visioncare) and Proclear Compatibles (CooperVision) contralaterally for 7 hours and rated comfort and dryness on a zero-to-100 point visual analog scale at 0, 1, 3, 5 and 7 hours. RESULTS: In both groups, no lens differences were found for comfort and dryness, but the comfort and dryness ratings of the symptomatic group decreased significantly (became worse) over the 7-hour period. CONCLUSIONS: These results demonstrate that dryness and comfort is the same over time with silicone hydrogel as with the other three lenses.

Adult↗

Successful monovision contact lens wearers refitted with bifocal contact lenses.

PURPOSE: Should successful monovision contact lens wearers be refitted with bifocal lenses? METHODS: Fifty current monovision lens wearers were fitted with ACUVUE Bifocal contact lenses (Johnson & Johnson Vision Care, Jacksonville, FL). Visual function and subjective vision ratings were assessed with habitual monovision lenses at the first visit and then were repeated at the end of 6 months while wearing bifocal lenses. Lens preference was determined at the end of the 6-month study, and the subjects were called 1 year later to repeat the lens preference questionnaire. RESULTS: Forty (80%) subjects completed the 6-month study; nine discontinued for visual reasons. At the end of 6 months of wear, 68% preferred bifocal lenses and 25% preferred monovision. Of the subjects who were contacted a year later, 53% were still wearing bifocal lenses. High-contrast visual acuity and letter contrast sensitivity at distance was the same for monovision and bifocal lenses, but low-contrast acuity was better with monovision. Intermediate low- and high-contrast acuity and 3-meter and near stereoscopic acuity were better with bifocal lenses. Near high- and low-contrast acuity were better with monovision. All subjective ratings, except near vision in poor lighting, were significantly greater with bifocal lenses. CONCLUSIONS: It is possible to refit successful monovision lens wearers with simultaneous vision bifocal lenses, and these lenses should be considered as an alternative method for the correction of presbyopia. In addition, subjective responses to bifocal lenses may not be reflective of visual function measurements.

Adult↗

Topographical thickness of the epithelium and total cornea after hydrogel and PMMA contact lens wear with eye closure.

PURPOSE: To determine changes in topographical thickness of the epithelium and total cornea after hydrogel (2-hydroxyethyl methacrylate; HEMA or soft lens) and PMMA rigid contact lens wear with eyes closed, as measured by optical coherence tomography (OCT). METHODS: Epithelial and total corneal thickness in 18 neophyte eyes was measured with OCT at intervals of 10 degrees across a 10-mm zone of the horizontal meridian of the cornea, before and after 3 hours of soft and rigid contact lens wear with the eye closed. These measurements were repeated 20 minutes after removal of the lenses. RESULTS: Lens type, time, and location were found to be significant main influences (P < 0.0001) on corneal swelling in patched eyes, by three-way ANOVA, and there was a significant three-way interaction among lens type, time, and location (F((16,272)) = 1.78, P = 0.033). However, there was no significant main effect and interaction of epithelial thickness (F((16, 272)) = 0.33, P = 0.99). Immediately after removal of the lenses, total corneal thickness in the horizontal meridian was significantly greater with both soft and PMMA lenses (P < 0.001) at each location with each lens, compared with the baseline measurements. With both lenses, the increase in actual thickness and percentage of corneal swelling at the center was greater than at each peripheral point (excluding the first 10 degrees points; P < 0.005). HEMA lenses caused greater corneal swelling than the PMMA lenses at each location immediately after removal of the lenses (P < 0.005). CONCLUSIONS: This study shows that corneal swelling is dependent on lens type and corneal location when eyes are closed, but epithelial thickness across the horizontal corneal meridian does not change during lens wear with eyes closed. OCT is an efficient method of measuring topographical corneal and epithelial thickness in response to contact lens wear.

Adult↗

Precorneal and pre- and postlens tear film thickness measured indirectly with optical coherence tomography.

PURPOSE: To demonstrate the feasibility of indirectly measuring the precorneal tear film thickness and pre- and postlens tear film (PLTF) thickness using optical coherence tomography (OCT). METHODS: Central corneal thickness (C(1)) which includes the tear film (T) of both eyes of 40 non-contact lens wearers was measured using OCT after calibration. The mean age of the 40 subjects was 31.2 +/- 9.3 years with a mean horizontal K-reading of 7.87 mm. Rigid contact lenses with base curves 0.3- to 0.5-mm steeper than the flattest K of the eye were fitted to measure real corneal thickness (C(2)), independently of the postlens tear film. T was calculated by T = C(1) - C(2). To measure pre- and postlens tear film thickness, Focus Night & Day and Acuvue lenses (Vistakon, Johnson & Johnson Vision Care, Jacksonville, FL) were fitted on both eyes. Central soft lens thickness (L(1)), which includes the prelens tear film (P), was measured by OCT in situ and in saline in a wet cell (L(2)). P was calculated by P = L(1) - L(2). Thickness of the central cornea plus the postlens tear film (C(3)) was measured during lens wearing. Postlens tear film (PLTF) was calculated by PLTF = C(3) - C(2). RESULTS. The mean +/- SD precorneal tear film thickness was 3.3 +/- 1.5 microm (range, 0-6.9) before lens insertion and 4.7 +/- 2.3 microm (range, 0.7-11.0) after lens fitting, which was significantly thicker (paired t-test: P < 0.01). The prelens tear film thickness was 3.9 +/- 2.6 and 3.6 +/- 2.1 microm (mean +/- SD; paired t-test: P = 0.52) and the postlens tear film thickness was 4.5 +/- 2.3 and 4.7 +/- 3.1 microm (paired t-test: P = 0.08) on and under Focus Night & Day and Acuvue lenses, respectively. Post hoc tests showed that precorneal (baseline) and prelens tear films were equivalent, and each was different (thinner; Tukey honestly significant difference P < 0.05) from the postlens tear film. CONCLUSIONS: OCT can noninvasively measure the thickness of the precorneal and prelens tear film as well as the postlens tear film. The thickness of the normal precorneal tear film is approximately 3 micro m and becomes thicker after lens fitting. The postlens tear film is thicker than the precorneal and prelens tear films with soft contact lenses. The thickness of both pre- and postlens tear films appears to be independent of the investigated lens types.

Adult↗

Topographical thickness of the epithelium and total cornea after overnight wear of reverse-geometry rigid contact lenses for myopia reduction.

PURPOSE: To investigate topographical thickness changes of the epithelium and total cornea measured with optical coherence tomography (OCT) after overnight wear of rigid gas-permeable lenses. METHODS: Reverse geometry design CRT (Dk=100) rigid (test) lenses (Paragon Vision Sciences, Mesa, AZ) were randomly fitted on one eye of each of 20 neophyte subjects (mean age, 24.6 +/- 2.7 years) and the other eye was fitted with an alignment tricurve rigid lens of the same material (control). Epithelial and total corneal thickness was measured at intervals of 10 degrees across a 10-mm zone of the horizontal meridian of the cornea, before and after overnight wear. Refractive error was measured with an autorefractor. These measurements were repeated 20 and 60 minutes and 3, 6, and 12 hours after lens removal. RESULTS: After one night of lens wear, myopia decreased in the test eye by 1.18 +/- 0.81 D, which was significantly different from baseline (P<0.001). No significant change was found in the control eye. Twelve hours after removal, two thirds of the myopic reduction was still present. Different topographical swelling patterns were induced by the two lens designs, with greatest swelling occurring in the center with the control lens and in the midperiphery with the test lenses (polynomial regression: P<0.005). Significantly greater central corneal swelling was found with the control lens than the test lens (6.9% +/- 3.1% vs. 4.9% +/- 2.0%, respectively, P=0.006). The effect on epithelial thickness differed between lenses and depended on both position and time (F(48,912)=2.3; P=0.000). Immediately after removal of the test lens, the central epithelium was 5.1% +/- 4.5% thinner than baseline, and all other locations (P<0.005 post hoc tests) and the epithelium in the midperiphery showed significant thickening (1.9% on the temporal side and 2.4% on the nasal side, both P<0.006 compared with the baseline). There were no significant changes in epithelial thickness with the control lens during the study period (post hoc tests: P>0.05). CONCLUSIONS: The optical coherence tomograph is a sensitive instrument that can detect small changes in epithelial and corneal thickness across the entire cornea. Topographical thickness changes of the epithelium and total cornea induced by one night of reverse-geometry lens wear appear to be associated with the decrease of myopia.

Adult↗

The measurement of corneal epithelial thickness in response to hypoxia using optical coherence tomography.

PURPOSE: To determine if corneal epithelial thickness increases in association with corneal edema induced by wearing soft contact lenses during eye closure. DESIGN: Experimental study. METHODS: One eye (randomly selected) of twenty noncontact lens wearers (10 males and 10 females, age 35.6 +/- 9.6 years) was patched during 3 hours of soft contact lens (SCL) wear and the contralateral eye acted as a control. Corneal and epithelial thickness of both eyes was measured before and after SCL wear using optical coherence tomography (OCT). RESULTS: Immediately after contact lens removal, total corneal thickness was increased significantly by 13.8 +/- 2.3% (mean +/- SD) compared with baseline (P <.0001, paired t test) and after 100 minutes was still 4.5 +/- 2.3% thicker than baseline (P <.0001, paired t test). The control eyes showed no change in total corneal thickness (P >.05, paired t test). Immediately after contact lens removal, corneal epithelial thickness was increased by 1.7 +/- 4.8%, but this change was not statistically significant (P >.05, paired t test). Following contact lens removal, epithelial thickness changed significantly (Repeated measure analysis of variance [Re-ANOVA]: F((7,133)) = 4.91, p(H-F) < 0.001) over the next 100 minutes with thinning recorded at 60, 80, and 100 minutes (P <.05, paired t test). There was no significant change over time in epithelial thickness of the control eyes (Re-ANOVA: F(4, 76) = 0.91, p(H-F) = 0.464). CONCLUSION: OCT demonstrated that corneal epithelial thickness does not increase in response to hypoxia from SCL wear and eye closure, in contrast to a significant increase in total corneal thickness.

Adult↗

Relation between optical coherence tomography and optical pachymetry measurements of corneal swelling induced by hypoxia.

PURPOSE: To determine the relation between optical coherence tomography (OCT) and optical pachymetry (OP) measurements of corneal swelling induced by hypoxia. DESIGN: Experimental study. METHODS: One randomly selected eye of 20 noncontact lens wearers (10 males and 10 females, age 35.6 +/- 9.6 years) was patched during 3 hours of soft contact lens (SCL) wear while the contralateral eye acted as control. Central corneal thickness of both eyes was measured before and after SCL wear using OCT and OP in randomized order. RESULTS: Baseline central corneal thickness was 523.6 +/- 33.0 microm (mean +/- standard deviation [SD]) measured with OCT and 490.6 +/- 25.5 microm with OP. Immediately after contact lens removal, corneal thickness measured with OCT increased by 13.8 +/- 2.3% compared with 12.1 +/- 1.8% (paired t test: P <.001) measured with OP. Thereafter, corneal thickness decreased at the rate of 5.6% per hour for OCT and 5.4% per hour for OP. The difference in thickness between instruments before lens insertion, which was 33 microm compared with the difference after lens removal (edematous cornea), which ranged from 46 to 41 microm. The difference between instruments decreased during the corneal deswelling period after lens removal. The correlation coefficient between OCT and OP was 0.914 before lens insertion and 0.932 after lens removal. CONCLUSION: This study has demonstrated the difference of corneal thickness measured with OCT and OP. Although both instruments are correlated highly in all conditions tested, OCT may overestimate corneal thickness in normal and edematous corneas.

Adult↗