Dieter Haemmerich

Publications and source records attributed to Dieter Haemmerich.

At least 19 recordsLinked to original sources

Multiple-electrode radiofrequency ablation creates confluent areas of necrosis: in vivo porcine liver results.

PURPOSE: To prospectively evaluate, in vivo in pigs, an impedance-based multiple-electrode radiofrequency (RF) ablation system for creation of confluent areas of hepatic coagulation. MATERIALS AND METHODS: The study was preapproved by the institutional research animal care and use committee. A prototype multiple-electrode RF system that enables switching between three electrically independent electrodes at impedance spikes was created. Forty-two coagulation zones (18 with single, 12 with cluster, and 12 with multiple [three single electrodes spaced 2 cm apart] electrodes) were created at laparotomy in 15 female pigs. Half the ablations were performed for 12 minutes, and half were performed for 16 minutes. The coagulation zones were excised and sliced into approximately 3-mm sections for measurement. Analysis of variance and two-sample t tests (with Bonferroni correction, alpha = .0033) were used to assess for differences between groups. RESULTS: At 12 minutes, the mean multiple-electrode coagulation was significantly larger than the mean single-electrode coagulation (minimum diameter, 2.8 vs 1.6 cm; maximum diameter, 4.2 vs 2.0 cm; volume, 22.1 vs 6.7 cm(3); P < .0033 for all comparisons). The mean maximum diameter achieved at 12 minutes with multiple electrodes was significantly larger than that achieved with the cluster electrode (4.2 vs 2.9 cm, P = .02). At 16 minutes, the mean multiple-electrode coagulation (minimum diameter, 3.2 cm; maximum diameter, 4.2 cm; volume, 29.1 cm(3)) was significantly larger than the mean single-electrode (minimum diameter, 1.7 cm; maximum diameter, 2.2 cm; volume, 7.1 cm(3); P < .0033 for all comparisons) and cluster-electrode (minimum diameter: 2.3 cm, P = .007; maximum diameter: 3.2 cm, P = .005; volume: 13.1 cm(3), P = .001) coagulations. CONCLUSION: Compared with the single and cluster systems used as controls, the multiple-electrode RF ablation system enabled the creation of significantly larger coagulation zones.

Animals↗

Hepatic radiofrequency ablation at low frequencies preferentially heats tumour tissue.

PURPOSE: Radiofrequency ablation is a clinically accepted treatment modality for liver cancer. There are significant differences in dielectric properties between normal and cancer tissue in the liver, which are particularly pronounced at frequencies below 100 kHz. This study performed computer simulations to determine whether radiofrequency (RF) ablation at lower frequencies than currently employed (450-500 kHz) can take advantage of this difference to preferentially deposit energy within the tumour. MATERIALS AND METHODS: Finite Element Method computer models were created for a cooled needle electrode and a multi-tine RF electrode inserted into a 2 cm diameter tumour. RF ablation was simulated and current density as well as tissue temperature distribution determined. In vivo data were used on electrical conductivity of normal and cancer tissue in the models to simulate RF ablation in liver at the currently used frequency of 500 kHz and at 10 kHz. RESULTS: At 500 kHz there was little difference in RF current density and final tissue temperature between normal and cancer tissue. Due to the more pronounced differences in electrical conductivity at 10 kHz, cancer tissue was heated preferentially at this frequency. Depending on power control algorithm, this resulted in either higher intra-tumour temperatures or lower temperatures outside the tumour at 10 kHz compared to 500 kHz. CONCLUSION: Radiofrequency ablation at lower frequencies than currently used may preferentially heat the tumour and preserve normal tissue. A targeted device for selective tumour destruction may be designed to make use of this principle.

Catheter Ablation↗

Convective cooling effect on cooled-tip catheter compared to large-tip catheter radiofrequency ablation.

BACKGROUND: Both actively cooled-tip and large-tip catheters are currently available clinically to create large endomyocardial lesions during application of radiofrequency (RF) energy. The purpose of this study was to compare the effect of convective cooling at physiologic flow rates on RF lesion size using both actively cooled and large-tip catheters. METHODS: Porcine hearts were sectioned into 72 pieces and placed in a temperature-controlled saline bath (37 degrees C) with varying directed flow rates (0, 1, 2, and 3 L/min). Cooled-tip RF ablation (4 mm tip) was performed for 1 minute on 36 tissue sections with power manually titrated to keep tip temperature below 40 degrees C. Large-tip catheter ablation (10 mm tip) was performed at 65 degrees C target temperature for 1 minute on 36 tissue sections. For each catheter, flow rates were randomized between applications. The tissue pieces were sectioned and measured to determine lesion depth, width, and volume. RESULTS: Lesion dimensions were independent of the flow rate for the cooled-tip catheter (mean volumes: 382.0 +/- 121.6, 419.9 +/- 133.4, 375.9 +/- 169.1, and 346.7 +/- 173.4 mm(3) for 0, 1, 2, and 3 L/min flow rate, respectively, P = 0.78). For the large-tip catheter, lesion size varied significantly with flow, such that higher flow rates produced larger lesions (mean volumes: 120.7 +/- 50.7, 256.5 +/- 97.9, 393.4 +/- 149.9, and 548.9 +/- 157.0 mm(3) for 0, 1, 2, and 3 L/min flow rate respectively, P < 0.001) CONCLUSION: During RF ablation, blood flow rate significantly affects lesion size for large-tip but not cooled-tip catheters. At low flow rates (0-1 L/min) cooled-tip catheters create larger lesions, while at high flow rates (3 L/min) large-tip catheters create larger lesions.

Animals↗

Effects of the time response of the temperature sensor on thermodilution measurements.

Thermodilution is widely used to measure cardiac output, ejection fraction and end diastolic volume. Even though the method is based on dynamic temperature measurements, little attention has been paid to the characterization of the dynamic behavior of the temperature sensor and to its influence on the accuracy of the method. This paper presents several theoretical and empirical results related to the thermodilution method. The results show that, at flow velocities above 0.2 m s(-1), the response of temperature sensors embedded in Swan-Ganz catheters can be accurately described by a convolution operation between the true temperature of the blood and the impulse response of the sensor. The model developed is used to assess the influence of the probe response on the measurement of cardiac output, and this study leads us to the conclusion that the probe response can cause errors in the cardiac output measurement, but this error is usually small (2% in cases with a high degree of arrhythmia). The results show that these small errors appear during arrhythmias that affect the R-R interval and when the real temperature distribution at the pulmonary artery does not possess a shape with perfect temperature plateaux.

Animals↗

Automatic control of finite element models for temperature-controlled radiofrequency ablation.

BACKGROUND: The finite element method (FEM) has been used to simulate cardiac and hepatic radiofrequency (RF) ablation. The FEM allows modeling of complex geometries that cannot be solved by analytical methods or finite difference models. In both hepatic and cardiac RF ablation a common control mode is temperature-controlled mode. Commercial FEM packages don't support automating temperature control. Most researchers manually control the applied power by trial and error to keep the tip temperature of the electrodes constant. METHODS: We implemented a PI controller in a control program written in C++. The program checks the tip temperature after each step and controls the applied voltage to keep temperature constant. We created a closed loop system consisting of a FEM model and the software controlling the applied voltage. The control parameters for the controller were optimized using a closed loop system simulation. RESULTS: We present results of a temperature controlled 3-D FEM model of a RITA model 30 electrode. The control software effectively controlled applied voltage in the FEM model to obtain, and keep electrodes at target temperature of 100 degrees C. The closed loop system simulation output closely correlated with the FEM model, and allowed us to optimize control parameters. DISCUSSION: The closed loop control of the FEM model allowed us to implement temperature controlled RF ablation with minimal user input.

Algorithms↗

In vitro measurements of temperature-dependent specific heat of liver tissue.

We measured the specific heat of liver tissue in vitro by uniformly heating liver samples between two electrodes. We insulated the samples by expanded polystyrene, and corrected for heat loss and water loss. The specific heat of the liver is temperature-dependent, and increases by 17% at 83.5 degrees C (p < 0.05), compared to temperatures below 65 degrees C. The average specific heat was 3411 J kg(-1)K(-1) at 25 degrees C, and 4187 J kg(-1)K(-1) at 83.5 degrees C. Water loss from the samples was significant above 70 degrees C, with approximately 20% of reduction in sample mass at 90 degrees C.

Animals↗

Measurement of temperature-dependent specific heat of biological tissues.

We measured specific heat directly by heating a sample uniformly between two electrodes by an electric generator. We minimized heat loss by styrofoam insulation. We measured temperature from multiple thermocouples at temperatures from 25 degrees C to 80 degrees C while heating the sample, and corrected for heat loss. We confirm method accuracy with a 2.5% agar-0.4% saline physical model and obtain specific heat of 4121+/-89 J (kg K)(-1), with an average error of 3.1%.

Animals↗

Multiple-electrode radiofrequency ablation: simultaneous production of separate zones of coagulation in an in vivo porcine liver model.

PURPOSE: A multiple-electrode radiofrequency (RF) system was developed based on switching between electrodes that allows for the simultaneous use of as many as three electrically independent electrodes. The purpose of this study was to determine if each multiple-electrode ablation zone is identical to an ablation zone created with conventional single-electrode mode. MATERIALS AND METHODS: Nine female domestic pigs (mean weight, 90 kg) were used for this study. A prototype monopolar multiple-electrode RF ablation system was created with use of an RF generator and an electronic switching algorithm. A maximum of three electrodes can be used simultaneously by switching between electrodes at each impedance spike (30 omega greater than baseline levels). A total of 39 zones of ablation were created at open laparotomy in pig livers with use of a conventional single electrode (n = 9), two single electrodes simultaneously (n = 6 ablations; 12 ablation zones), or three single electrodes simultaneously (n = 6 ablations; 18 ablation zones). RF electrodes were spaced in separate lobes of the liver when multiple zones of coagulation were created simultaneously. Animals were euthanized after RF ablation, livers were removed, and ablation zones were sectioned and measured. RESULTS: Zones of coagulation created simultaneously with two or three electrodes were equivalent to ablation zones created with use of conventional single-electrode ablation. No significant differences were observed among control animals treated with a single electrode, those with two separate zones of ablation created simultaneously, and those with three simultaneously created ablation zones in terms of mean (+/-SD) minimum diameter (1.6 cm +/- 0.6, 1.6 cm +/- 0.5, and 1.7 cm +/- 0.4, respectively), maximum diameter (2.0 cm +/- 0.5, 2.3 cm +/- 0.5, 2.2 cm +/- 0.5, respectively), and volume (6.7 cm3 +/- 3.7, 7.4 cm3 +/- 3.8, and 7.8 cm3 +/- 3.9; P > .30, analysis of variance, pairwise t-test comparisons). CONCLUSIONS: A rapid-switching multiple-electrode RF system was able to simultaneously create as many as three separate ablation zones of equivalent size compared with single-electrode controls. This system would allow physicians to simultaneously treat multiple tumors, substantially reducing procedure time and anesthesia risk.

Algorithms↗

Haemostatic partial nephrectomy using bipolar radiofrequency ablation.

OBJECTIVE: To determine whether an electrode array with a bipolar radiofrequency ablation (RFA) energy source can be used to perform a haemostatic partial nephrectomy by simultaneously ablating and coagulating renal tissue. MATERIALS AND METHODS: Lower-pole partial nephrectomy was performed in 12 porcine kidneys using a bipolar RFA system. Intraoperative ultrasonography was used to identify and avoid the collecting system. Tissues were positioned between opposing electrodes and tissue impedance monitored using a proprietary feedback and control algorithm. Ablation time and power, lesion width and length, and tissue thickness were recorded. The kidneys were assessed in vivo to show haemostasis of the remaining renal unit. Collecting system integrity was assessed with methylene blue injection, and the resected tissue analysed histologically. RESULTS: Partial nephrectomies were successful in all 12 porcine kidneys; the mean nephrectomy specimen was 3.2 x 2.6 cm. The total ablation time (sem) per lesion was 211 (15) s and the mean power was 23 W. Methylene blue injection showed an intact collecting system in 11 of the 12 kidneys, and haematoxylin and eosin staining showed a mean zone of necrosis of 9 mm at the resection margin. Ultrasonography revealed flow to the remaining kidneys after RFA and the in vivo assessment of haemostasis revealed no abnormal bleeding or haemorrhage from the kidneys. CONCLUSIONS: Applying bipolar RF energy to an electrode array can enable transmural excision of renal parenchyma in vivo in a bloodless fashion without collecting system injury.

Animals↗

Large-volume radiofrequency ablation of ex vivo bovine liver with multiple cooled cluster electrodes.

Three methods of creating large thermal lesions with cool-tip cluster electrodes were compared. Three cluster electrodes were arranged 4 cm apart in a triangular array. Eight lesions were created ex vivo in fresh bovine liver (from a butcher) with each method: sequential ablation (three electrodes, 12 minutes each); simultaneous activation of electrodes (12 minutes); and rapid switching of power between electrodes (12 minutes), for which an electronic computer-controlled switch was developed. For sequential, rapid switching, and simultaneous methods, lesion volumes were 137.5 cm(3)+/- 22.2, 116.4 cm(3)+/- 15.2, and 22.3 cm(3)+/- 6.4 (P < .05), respectively, and final temperatures at lesion center were 80 degrees C +/- 5, 97 degrees C +/- 8, and 41 degrees C +/- 3 (P < .001), respectively. Because of electrical interference between electrodes, simultaneous method led to little heating at the center between the electrodes and created small discontinuous lesions. Rapid switching created large round lesions by employing multiple electrodes concurrently, which substantially reduced treatment time and resulted in more effective heating between electrodes.

Animals↗

Lesion size estimator of cardiac radiofrequency ablation at different common locations with different tip temperatures.

Finite element method (FEM) analysis has become a common method to analyze the lesion formation during temperature-controlled radiofrequency (RF) cardiac ablation. We present a process of FEM modeling a system including blood, myocardium, and an ablation catheter with a thermistor embedded at the tip. The simulation used a simple proportional-integral (PI) controller to control the entire process operated in temperature-controlled mode. Several factors affect the lesion size such as target temperature, blood flow rate, and application time. We simulated the time response of RF ablation at different locations by using different target temperatures. The applied sites were divided into two groups each with a different convective heat transfer coefficient. The first group was high-flow such as the atrioventricular (AV) node and the atrial aspect of the AV annulus, and the other was low-flow such as beneath the valve or inside the coronary sinus. Results showed the change of lesion depth and lesion width with time, under different conditions. We collected data for all conditions and used it to create a database. We implemented a user-interface, the lesion size estimator, where the user enters set temperature and location. Based on the database, the software estimated lesion dimensions during different applied durations. This software could be used as a first-step predictor to help the electrophysiologist choose treatment parameters.

Algorithms↗

Theoretical analysis of the heat convection coefficient in large vessels and the significance for thermal ablative therapies.

Ablative therapies such as radio-frequency (RF) ablation are increasingly used for treatment of tumours in liver and other organs. Often large vessels limit the extent of the thermal lesion, and cancer cells close to the vessel survive resulting in local tumour recurrence. Accurate estimates of the heat convection coefficient h for large vessels will help improve ablation techniques, and are required for estimation of thermal lesion dimensions in simulations. Previous estimates of h did not consider that only part of the vessel is heated, and assumed uniform temperature distribution at the vessel wall. An analytical relationship between the heat convection coefficient, blood velocity and temperature is formulated. The heat convection coefficient evaluated will assist both simulations and design of proper protocols for in vivo measurements. The mathematical model developed in this work describes the exchange of heat between a solid surface and a moving fluid and it is based on energy and motion equations for Navier-Stokes fluids. A particular case of a laminar blood flow in the portal vein is studied when a portion of its surface is heated. The results show that heating a larger portion of the vessels reduces convective heat loss, which may result in more effective ablation strategies.

Blood Flow Velocity↗

In vivo electrical conductivity of hepatic tumours.

Knowledge of electrical tissue conductivity is necessary to determine deposition of electromagnetic energy and can further be used to diagnostically differentiate between normal and neoplastic tissue. We measured 17 rats with a total of 24 tumours of the K12/TRb rat colon cancer cell line. In each animal we measured in vivo hepatic tumour and normal tissue conductivity at seven frequencies from 10 Hz to 1 MHz, at different tumour stages between 6 and 12 weeks after induction. Conductivity of normal liver tissue was 1.26 +/- 0.15 mS cm(-1) at 10 Hz, and 4.61 +/- 0.42 mS cm(-1) at 1 MHz. Conductivity of tumour was 2.69 +/- 0.91 mS cm(-1) at 10 Hz, and 5.23 +/- 0.82 mS cm(-1) at 1 MHz. Conductivity was significantly different between normal and tumour tissue (p < 0.05). We determined the percentage of necrosis and fibrosis at the measurement site. We fitted the conductivity data to the Cole-Cole model. For the tumour data we determined Spearman's correlation coefficients between the Cole-Cole parameters and age, necrosis, fibrosis and tumour volume and found significant correlation between necrosis and the Cole-Cole parameters (p < 0.05). We conclude that necrosis within the tumour and the associated membrane breakdown is likely responsible for the observed change in conductivity.

Animals↗

Bipolar radiofrequency ablation of the kidney: comparison with monopolar radiofrequency ablation.

PURPOSE: We report initial ex vivo and in vivo studies using bipolar radiofrequency (RF) ablation of porcine kidneys. An internal ground electrode is positioned in the kidney opposite the RF electrode, resulting in ablation of all the intervening renal tissue. MATERIALS AND METHODS: Ex vivo preparations of 10 porcine kidneys were perfused continuously with Ringer's solution and treated with either standard external grounded RF (N = 3) or bipolar RF ablation with 1 (N = 2), 2 (N = 3), or 3 (N = 2) cm of separation between the ground probe and the RF probe using a Model 30 RITA generator (RITA, Mountain View, CA). Target temperatures were 90 degrees C for 8 minutes. Gross and histologic assessments were made acutely. Four domestic pigs were treated with monopolar RF ablation of the lower pole of one kidney and bipolar RF with a 12-mm separation between the probes of the contralateral lower pole. Animals were harvested 48 hours later to maximize tissue damage for gross measurements and histologic evaluation. RESULTS: Ex vivo studies revealed grossly monopolar lesions 1.5 cm in maximum diameter and 1.75 cm(3) in volume. In comparison, bipolar lesions were 2.8 cm in maximum diameter and 10.3 cm(3) in volume using 3 cm of electrode separation. There was histologic evidence of cell death in all specimens. In vivo studies showed two distinct gross lesions with RF: one blanched and one hemorrhagic. Using bipolar RF, larger blanched lesions were achievable than with monopolar RF (2.80 cm(3) v 1.63 cm(3)). Overall, the combinations of blanched and hemorrhagic lesions were similar with monopolar and bipolar RF (5.01 v 5.31 cm(3)). Histologic evaluation verified cell death in the blanched lesions and rare areas of normal tissue in the hemorrhagic lesions. CONCLUSIONS: As shown by ex vivo data, bipolar RF can create larger lesions than does monopolar RF. In vivo, at 48 hours, both blanched and hemorrhagic gross lesions were seen using RF. In this model, blanched lesions predominated when performing bipolar RF.

Animals↗

Multiple probe radiofrequency ablation: pilot study in an animal model.

PURPOSE: Radiofrequency ablation (RFA) is becoming increasingly popular for the minimally invasive treatment of benign and malignant tumors. Currently available systems are limited to the use of a single probe because of electrical interactions between probes. The purpose of this study was to test a new prototype multiple probe generator with a built-in switching mechanism to determine if multiple zones of necrosis could be formed simultaneously without a significant penalty in terms of lesion size and procedure time. MATERIALS AND METHODS: A dual probe generator was created by modifying a commercially available system into an alternating monopolar system with an external electronic switch controlled by a temperature feedback loop. A total of 20 radiofrequency (RF) lesions (conventional single probe, n = 10; switched dual probe, n = 10) were created in the livers of six adult pigs (temperature, 100 degrees C; 10-minute ablation). Lesions were excised and examined for volume, minimum diameter, and maximum diameter. RESULTS: The time to target temperature was slightly greater for dual (3.5 minutes) versus single ablations (2.7 minutes). However, this resulted in only a 48 second (6.5%) longer total ablation time. There was no significant difference between conventional single and dual lesions for lesion volume (13.6 +/- 9.3 cm(3) versus 13.7 +/- 7.0 cm(3); P >.05), minimum diameter (1.63 +/- 0.56 cm(3) versus 1.61 +/- 0.53; P >.05) or maximum diameter (3.3 +/- 0.84 versus 3.4 +/- 0.55, P >.05). CONCLUSION: A multiple probe RFA system that can simultaneously ablate multiple areas in the liver is feasible. If multiple probe units become clinically available, large or irregularly shaped lesions could be treated more effectively than with conventional single probe units, and multiple tumors could be ablated simultaneously, thus potentially decreasing procedure time and anesthetic complications.

Animals↗

Hepatic radiofrequency ablation with internally cooled probes: effect of coolant temperature on lesion size.

Radiofrequency (RF) ablation is a minimally invasive method for treatment of primary and metastatic liver tumors. One of the currently commercially available devices employs an internally cooled 17-gauge needle probe. Within the probe, cool water is circulated during ablation, which cools tissue close to the probe resulting in larger lesions. We evaluated the effect of different cooling water temperatures on lesion size. We created a finite-element method model, simulated 12 min impedance-controlled ablation and determined temperature distribution for three water temperatures. Lesion diameters in the model were 33.8, 33.4, and 32.8 mm for water temperatures of 5 degrees C, 15 degrees C, and 25 degrees C, respectively. We solved a simplified model geometry analytically and present dependence of lesion diameter on cooling temperature. We further performed ex vivo experiments in fresh bovine liver. We created four lesions for each water temperature, with the same water temperatures as used in the finite-element method (FEM) model. Average lesion diameters were 28.3, 30, and 29.5 mm for water temperatures of 5 degrees C, 15 degrees C, and 25 degrees C, respectively. Water temperature did not have a significant effect on lesion size in the ex vivo experiments (p = 0.76), the FEM model, and the analytical solution.

Animals↗

Mechanical compliance of the endocardium.

Radio-frequency (RF) ablation is an accepted treatment for cardiac arrhythmias related to abnormal focal cardiac substrate. The penetration depth of the electrode into the endocardium affects lesion size, a critical determinant of success of RF ablation. We measured the relation between the mechanical compliance and the penetration depth of RF ablation catheter electrode at frequently ablated areas of the endocardium and examined the influence of time after death on mechanical properties of the tissue. We measured force versus time for eight insertion depths of the catheter electrode into full-thickness endocardial samples derived from the mitral valve annulus, the left ventricular free wall and the tricuspid valve annulus. We varied the time after death at 15, 40 min, 3, 8, and 18 h and repeated our measurements. At 15 min after death, the first 0.5mm penetration depth caused the fastest relaxation at 55 s. Force decay decreased dramatically at 15 min after death as the penetration depth increased from 0.5 to 4mm. We used the force data sampled at 60s after insertion to approximate the elasticity. We observed the relations between the force versus the insertion depth. The force increased by a factor of 5 for the mitral valve annulus and 8 for the left free wall from 15 min to 18 h. We derived coefficients of a second-order polynomial equation relating the force data to insertion depth with R(2)>0.99.

Animals↗