PubMed Health⌕ Search

Biomedical subjects

Dieter Liepsch

Publications and source records attributed to Dieter Liepsch.

6 recordsLinked to original sources

Biofluid mechanics--an interdisciplinary research area of the future.

Biofluid mechanics is a complex field that focuses on blood flow and the circulation. Clinical applications include bypass and anastomosis surgery, and the development of artificial heart valves and vessels, stents, vein and dialysis shunts. Biofluid mechanics is also involved in diagnostic and therapeutic measures, including CT and MRI, and ultrasound. The study of biofluid mechanics involves measuring blood flow, pressure, pulse wave, velocity distribution, the elasticity of the vessel wall, the flow behavior of blood to minimize complications in vessel,- neuro-, and heart surgery. Biofluid mechanics influence the lungs and circulatory system, the blood flow and micro-circulation; lymph flow, and artificial organs. Flow studies in arterial models can be done without invasive techniques on patients or animals. The results of fluid mechanic studies have shown that in the addition to basic biology, an understanding of the forces and movement on the cells is essential. Because biofluid mechanics allows for the detection of the smallest flow changes, it has an enormous potential for future cell research. Some of these will be discussed.

Biomechanical Phenomena↗

Theoretical approach to blood ejection from the human left ventricle.

An ejection dynamics mathematical model of human left ventricle (LV) based on physiological data of human heart is proposed in this study. The mathematical equations were expressed in terms of vorticity-stream function equations in a prolate spheroidal coordinate system. These equations combined with specified boundary conditions were numerically solved by using an alternating-direction-implicit (ADI) algorithm with second order accuracy. The unsteady aspects of the ejection process were subsequently introduced into the numerical simulation. The numerical results have shown that the present ellipsoidal model could be available to simulate the ejection process of the human LV. Such a model combined with cardiac muscle mechanics could be studied further to determine altered left ventricular function in cardiac diseases.

Adult↗

Changes in carotid artery flow velocities after stent implantation: a fluid dynamics study with laser Doppler anemometry.

PURPOSE: To study the influence of stent size and location on flow patterns in a physiological carotid model. METHODS: Wallstents were positioned in silicon models of the carotid artery at various locations: 2 stents appropriately sized to the anatomy were placed in (1) the internal carotid artery (ICA) and (2) the ICA extending completely into the common carotid artery so as to cover the external carotid artery (ECA) orifice. Another 2 stents were placed in the ICA extending (1) partially and (2) completely into the bulb to simulate stent displacement and disproportion between stent size and the original vessel geometry. Measurements were performed with laser Doppler anemometry (LDA) using pulsatile flow conditions (Reynolds number=250; flow 0.431 L/min; ICA:ECA flow rate ratio 70:30) in hemodynamically relevant cross sections. The hemodynamic changes were analyzed with 1-dimensional flow profiles. RESULTS: With the stent in the ICA, no changes of the normal flow profile were seen. For stents positioned in the ICA and extending partially or completely into the carotid bulb, the flow behavior was affected by the resistance of the stent to flow in the ECA. Hemodynamically relevant disturbances were seen in the ICA and ECA, especially in the separation zones (regions along the walls just after a bifurcation, bend, or curve). The ICA:ECA flow rate ratios shifted from 70:30 to 71.3:28.7 and from 70:30 to 75.1:24.9, respectively, in the 2 malpositioned stent models. With the stent placed in the ICA extending completely into the CCA, the ICA:ECA flow rate ratio shifted from 70:30 to 72.4:27.6. In this configuration, there were no notable flow changes in the ICA, but a clear diminishing of the separation zones in the ECA separation zones. CONCLUSIONS: Anatomically correct positioning of appropriately sized stents does not lead to relevant flow disturbances in the ICA. In the ECA, depending on the position, size, and interstices of the stent, the physiological flow was considerably disturbed when any part of the stent covered the inflow of the vessel. Disturbances were seen when the stent was positioned into the bulb. For clinical application, stent location and size must be carefully determined so that the stent covers the bifurcation completely or is in the ICA only.

Blood Flow Velocity↗

Experimental flow studies in an elastic Y-model.

To determine the causes and history of atherosclerosis it is necessary to understand the hemodynamic parameters of blood circulation. Hemodynamic parameters play an important role in the formation of atherosclerotic plaques, especially near bends and bifurcations where the flow separates from the wall. Here the flow is laminar and non-axial with eddies, secondary flow, flow separation and stagnation points. Stenoses are found predominantly in flow separation areas. Therefore, it is important to separately study the following flow parameters: steady and pulsatile flow, wall elasticity and non-Newtonian flow behavior of blood. A simplified silicon elastic y-model simulating the human carotid artery was used for the analysis of these parameters. This model can be used for numerical studies as well. Flow was visualized at steady flow using dyes and at pulsatile flow with a photoelastic apparatus and a birefringent solution. The local axial velocity at steady and pulsatile flow was determined with a one-component Laser-Doppler-Anemometer (LDA). Pulsatile flow was generated by a piston membrane pump. A glycerin-water solution was used to simulate the Newtonian flow behavior of blood. A DMSO-Separan water solution was used to simulate the non-Newtonian flow behavior. Pulsatile flow creates higher and lower shear rates so called oscillating shear rate compare to steady flow depending on the velocity amplitude. The non-Newtonian fluid showed a markedly different flow behavior than the Newtonian fluid especially in areas of flow separation. Shear gradients were calculated from these velocity measurements using a bicubic spline interpolation. Shear stresses were calculated from these velocity shear gradients and the viscosity of the non-Newtonian fluid at these shear gradients. At special areas, high shear stresses > 10 Pa were found. The elasticity of the model wall also influences the flow behavior. The measurements showed that the characteristics of pulsatile flow and the elasticity of the model wall should be observed concomitantly. This paper presents the steady and pulsatile flow with a Newtonian and non-Newtonian fluid in an elastic model.

Arteriosclerosis↗

An introduction to biofluid mechanics--basic models and applications.

Cardiovascular disease is the primary cause of morbidity and mortality in the western world. Complex hemodynamics play a critical role in the development of atherosclerosis and the processes of aging, as well as many other disease processes. Biofluid mechanics play a major role in the cardiovascular system and it is important to understand the forces and movement of blood cells and whole blood as well as the interaction between blood cells and the vessel wall. Fundamental fluid mechanical, which are important for the understanding of the blood flow in the cardiovascular circulatory system of the human body aspects are presented. Measurement techniques for model studies such as LDA, ultrasound, and MRI studies will be discussed. Viscosity and flow behavior changes specifically the creation of vortices and flow disturbances can be used to show how medication can influence flow behavior. Experiments have shown that hemodynamics may have a strong influence on the creation of aneurysms and varicose veins. Other factors such as vessel wall structure are also important. In preliminary studies, it has been demonstrated that geometry and elasticity of vessel walls help determine flow behavior. High velocity fluctuations indicate flow disturbances that should be avoided. Health care practitioners must understand fluid dynamic factors such as flow rate ratio, pressure and velocity gradients, and flow behavior, velocity distribution, shear stress on the wall and on blood cells. These mechanical factors are largely responsible for the deposit of blood cells and lipids, a leading cause of atherosclerosis. The interaction between blood cells and of the cells with the vessel, leads to the formation of plaques and agglomerations. These deposits are found predominantly at arterial bends and bifurcations where blood flow is disturbed, where a secondary flow is created, and where flow separation regions are found. Experiments on hemodynamic effects in elastic silicon rubber models of the cardiovascular system with flow wire, stents, or patches for vessel surgery will be discussed. These studies can be important in improving diagnostics and therapeutic applications.

Animals↗

Flow velocities after carotid artery stenting: impact of stent design. A fluid dynamics study in a carotid artery model with laser Doppler anemometry.

PURPOSE: To study the influence of a newly developed membrane stent design on flow patterns in a physiologic carotid artery model. METHODS: Three different stents were positioned in silicone models of the carotid artery: a stainless steel stent (Wall-stent), a nitinol stent (SelfX), and a nitinol stent with a semipermeable membrane (MembraX). To increase the contact area of the membrane with the vessel wall, another MembranX model was modified at the outflow tract. The membrane consists of a biocompatible silicone-polyurethane copolymer (Elast-Eon) with a pore size of 100 mum. All stents were deployed across the bifurcation and the external carotid artery origin. Flow velocity measurements were performed with laser Doppler anemometry (LDA), using pulsatile flow conditions (Re = 220; flow 0.39 l/min; flow rate ratio ICA:ECA = 70:30) in hemodynamically relevant cross-sections. The hemodynamic changes were analyzed by comparing velocity fluctuations of corresponding flow profiles. RESULTS: The flow rate ratio ICA:ECA shifted significantly from 70/30 to 73.9/26.1 in the MembraX and remained nearly unchanged in the SelfX and Wallstent. There were no changes in the flow patterns at the inflow proximal to the stents. In the stent no relevant changes were found in the SelfX. In the Wallstent the separation zone shifted from the orifice of the ICA to the distal end of the stent. Four millimeters distal to the SelfX and the Wallstent the flow profile returned to normal. In the MembraX an increase in the central slipstreams was found with creation of a flow separation distal to the stent. With a modification of the membrane this flow separation vanished. In the ECA flow disturbances were seen at the inner wall distal to the stent struts in the SelfX and the Wallstent. With the MembraX a calming of flow could be observed in the ECA with a slight loss of flow volume. CONCLUSIONS: Stent placement across the carotid artery bifurcation induces alterations of the physiologic flow behavior. Depending on the stent design the flow alterations are located in different regions. All the stents tested were suitable for the carotid bifurcation. The MembraX prototype has shown promising hemodynamic properties ex vivo.

Alloys↗