PubMed Health⌕ Search

Biomedical subjects

Dieter Lubda

Publications and source records attributed to Dieter Lubda.

At least 19 recordsLinked to original sources

Fast, high-efficiency peptide separations on a 50-microm reversed-phase silica monolith in a nanoLC-MS set-up.

Proteomic studies have stimulated the development of novel stationary phases in miniaturised chromatographic columns that permit high linear flow velocities and exhibit high resolving power. In this work, a 50-microm reversed-phase silica-based monolith was chromatographically characterised for its use in proteomics applications using a nanoLC-MS set-up. It showed high efficiency for the separation of tryptic peptides under isocratic elution conditions (HETP(min)=5-10 microm at 2.4 mm/s). Flow rates up to 1.95 microL/min (18.4 mm/s) and gradient slopes up to an unusually fast 9% could be used. This resulted in rapid separations of peptide mixtures, with peak widths at half height of between 5 and 10 s. The 50-microm monolithic column was used to analyse depleted serum from a cervical cancer patient at a throughput of one sample per 30 min.

Amino Acid Sequence↗

Monolithic silica-based capillary column with strong chiral cation-exchange type surface modification for enantioselective non-aqueous capillary electrochromatography.

A silica-based monolithic stationary phase prepared by the sol-gel process in a 100 microm I.D. fused-silica (FS) capillary has been modified chemically with 3-mercaptopropyl trimethoxysilane followed by immobilization of a strong cation-exchange (SCX) type chiral selector, (S)-N-(4-allyloxy-3,5-dichlorobenzoyl)-2-amino-3,3-dimethylbutane phosphonic acid, by radical addition reaction onto the reactive sulfhydryl surface. After a fine-tuning of the mobile phase composition, the enantioselective capillary column was evaluated for the separation of various chiral basic drugs by enantioselective non-aqueous capillary electrochromatography (CEC), in comparison to capillary column analogs packed with 3.5 microm silica particles having attached the same selector. The performance of the monolithic silica column was further compared to corresponding polymethacrylate-based organic polymer monoliths. The study indicated that strong counter-ions such as 2-aminobutanol or N,N,N',N'-tetramethylethylenediamine are needed, although they reduce the electroosmotic flow velocity and separation factors in comparison to less efficient counter-ions, in order to allow the elution of the oppositely charged solutes in the ion-exchange retention mode within reasonable run time and as sharp zones. In contrast, weak counter-ions such as N,N-diisopropylethylamine (Huenig base) provided stronger electroosmotic flow and much better separation factors, but relatively poor peak efficiencies. Overall, with the chemically functionalized monolithic silica column the high quality separations of packed column analogs could be approximated, with regards to both separation factors and peak performances. On the other hand, the monolithic capillary column certainly outperformed the packed column in terms of system robustness under capillary electrochromatography conditions and showed excellent column longevity. The enantioselective strong cation-exchange-type monolithic silica column performed also well in comparison to the organic polymer monolith.

Cation Exchange Resins↗

Stereoselective separations of chiral phosphinic acid pseudodipeptides by CEC using silica monoliths modified with an anion-exchange-type chiral selector.

A nonaqueous CEC method for the simultaneous separation of the four stereoisomers of the N-benzyloxycarbonyl phosphinic pseudodipeptide methyl ester benzyloxycarbonyl-homophenylalanine Z-hPhepsi(PO2HCH2)Phe-OCH3 as well as of the corresponding N-2,4-dinitrophenyl (DNP)-derivative with free C-terminal carboxylic group DNP-hPhepsi(PO2HCH2)Phe-OH was developed. For this purpose, a monolithic silica capillary column modified with a cinchona alkaloid-derived anion-exchange-type chiral selector, namely O-9-(tert-butylcarbamoyl)quinidine (tBuCQD) was prepared. The mobile phase composition (ACN/methanol ratio, counterion type) was thoroughly optimized to end up with baseline resolution of all four stereoisomers with critical resolution of as high as about 2. The CEC method proved to be superior over the corresponding HPLC separations primarily due to significantly enhanced plate numbers (between 200,000 and 600,000 m(-1) in CEC). Diastereoselectivity contributions arising from electrophoretic mobility differences of the diastereomers facilitated the separation of the later eluted diastereomeric peak pair (peaks III and IV), but had a negative influence on the selectivity of the earlier eluted diastereomeric peak pair (peaks I and II). The stereoselective CEC assay allowed the assessment of the stereoisomeric purity of the individual isomers which were obtained by preparative HPLC on a CHIRALPAK QD-AX column that is based on the same tBuCQD selector. The present study demonstrates that there exist problems which are hard to solve by HPLC, yet can be conveniently solved by CEC. Moreover, it was intended to prove by this practical application that CEC with monolithic columns is robust enough to be used for solving real-life problems.

Anion Exchange Resins↗

Silica-based monolithic columns with mixed-mode reversed-phase/weak anion-exchange selectivity principle for high-performance liquid chromatography.

This article describes the synthesis, chromatographic characterization, and performance evaluation of analytical (100 x 4.6 mm id) and semipreparative (100 x 10 mm id) monolithic silica columns with mixed-mode RP/weak anion-exchange (RP/WAX) surface modification. The monolithic RP/WAX columns were obtained by immobilization of N-(10-undecenoyl)-3-aminoquinuclidine onto thiol-modified monolithic silica columns (Chromolith) by a radical addition reaction. Their chromatographic characterization by Engelhardt and Tanaka tests revealed slightly lower hydrophobic selectivities than C-8 phases, as well as higher polarity and also improved shape selectivity than RP-18e silica rods. The surface modification enabled separation by both RP and anion-exchange chromatography principles, and thus showed complementary selectivities to the RP-18e monoliths. The mixed-mode monoliths have been tested for the separation of peptides and turned out to be particularly useful for hydrophilic acidic peptides, which are usually insufficiently retained on RP-18e monolithic columns. Compared to a corresponding particulate RP/WAX column (5 microm, 10 nm pore diameter), the analytical RP/WAX monolith caused lower system pressure drops and showed, as expected, higher efficiency (e.g. by a factor of about 2.5 lower C-term for a tetrapeptide). The upscaling from the analytical to semipreparative column dimension was also successful.

Anions↗

Making broad proteome protein measurements in 1-5 min using high-speed RPLC separations and high-accuracy mass measurements.

The throughput of proteomics measurements that provide broad protein coverage is limited by the quality and speed of both the separations as well as the subsequent mass spectrometric analysis; at present, analysis times can range anywhere from hours (high throughput) to days or longer (low throughput). We have explored the basis for proteomics analyses conducted on the order of minutes using high-speed capillary RPLC combined through on-line electrospray ionization interface with high-accuracy mass spectrometry (MS) measurements. Short 0.8-microm porous C18 particle-packed 50-microm-i.d. capillaries were used to speed the RPLC separations while still providing high-quality separations. Both time-of-flight (TOF) and Fourier transform ion cyclotron resonance (FTICR) MS were applied for identifying peptides using the accurate mass and time (AMT) tag approach. Peptide RPLC relative retention (elution) times that were generated by solvent gradients that differed by at least 25-fold were found to provide relative elution times that agreed to within 5%, which provides the basis for using peptide AMT tags for higher throughput proteomics measurements. For fast MS acquisition speeds (e.g., 0.2 s for TOF and either approximately 0.3 or approximately 0.6 s for FTICR), peptide mass measurement accuracies of better than +/-15 ppm were obtained with the high-speed RPLC separations. The ability to identify peptides and the overall proteome coverage was determined by factors that include the separation peak capacity, the sensitivity of the MS (with fast scanning), and the accuracy of both the mass measurements and the relative RPLC peptide elution times. The experimental RPLC relative elution time accuracies of 5% (using high-speed capillary RPLC) and mass measurement accuracies of better than +/-15 ppm allowed for the confident identification of >2800 peptides and >760 proteins from >13,000 different putative peptides detected from a Shewanellaoneidensis tryptic digest. Initial results for both RPLC-ESI-TOF and RPLC-ESI-FTICR MS were similar, with approximately 2000 different peptides from approximately 600 different proteins identified within 2-3 min. For <120-s proteomic analysis, TOF MS analyses were more effective, while FTICR MS was more effective for the >150-s analysis due to the improved mass accuracies attained using longer spectrum acquisition times.

Animals↗

Ultrahigh-throughput proteomics using fast RPLC separations with ESI-MS/MS.

We describe approaches for proteomics analysis using electrospray ionization-tandem mass spectrometry coupled with fast reversed-phase liquid chromatography (RPLC) separations. The RPLC separations used 50-microm-i.d. fused-silica capillaries packed with submicrometer-sized C18-bonded porous silica particles and achieved peak capacities of 130-420 for analytes from proteome tryptic digests. When these separations were combined with linear ion trap tandem mass spectrometry measurements, approximately 1000 proteins could be identified in 50 min from approximately 4000 identified tryptic peptides; approximately 550 proteins in 20 min from approximately 1800 peptides; and approximately 250 proteins in 8 min from approximately 700 peptides for a S. oneidensis tryptic digest. The dynamic range for protein identification with the fast separations was determined to be approximately 3-4 orders of magnitude of relative protein abundance on the basis of known proteins in human blood plasma analyses. We found that 55% of the MS/MS spectra acquired during the entire analysis (and up to 100% of the MS/MS spectra acquired from the most data-rich zone) provided sufficient quality for identifying peptides. The results confirm that such analyses using very fast (minutes) RPLC separations based on columns packed with microsized porous particles are primarily limited by the MS/MS analysis speed.

Chromatography, High Pressure Liquid↗

Comprehensive pore structure characterization of silica monoliths with controlled mesopore size and macropore size by nitrogen sorption, mercury porosimetry, transmission electron microscopy and inverse size exclusion chromatography.

The porosity of monolithic silica columns is measured by using different analytical methods. Two sets of monoliths were prepared with a given mesopore diameter of 10 and 25 nm, respectively and with gradated macropore diameters between 1.8 and 7.5 microm. After preparing the two sets of monolithic silica columns with different macro- and mesopores the internal, external and total porosity of these columns are determined by inverse size-exclusion chromatography (ISEC) using polystyrene samples of narrow molecular size distribution and known average molecular weight. The ISEC data from the 4.6 mm analytical monolithic silica columns are used to determine the structural properties of monolithic silica capillaries (100 microm I.D.) prepared as a third set of samples. The ISEC results illustrate a multimodal mesopore structure (mesopores are pores with stagnant zones) of the monoliths. It is found by ISEC that the ratio of the different types of pores is dependent on the change in diameter of the macropores (serve as flow-through pores). The porosity data achieved from the mercury penetration measurement and nitrogen adsorption as well of scanning electron microscopy (SEM) and transmission electron microscopy (TEM) pictures are correlated with the results we calculated from the ISEC measurements. The ISEC results, namely the multimodal pore structure of the monoliths, reported in several publications, are not confirmed analyzing the pore structures of the different silica monoliths using all other analytical methods.

Adsorption↗

Combining restricted access material (RAM) and turbulent flow for the rapid on-line extraction of the cyclooxygenase-2 inhibitor rofecoxib in plasma samples.

Restricted access material (RAM) has been used in the packing of a solid-phase extraction (SPE) column for on-line extractions under turbulent flow conditions. The bio-compatible RAM material works by the principle of size exclusion in addition to conventional reversed-phase chromatography, thereby allowing the extraction and preconcentration of small analyte molecules from biological samples such as plasma. Using small column dimensions (0.76 mm x 50 mm) and a consequently high linear velocity, turbulent flow was achieved during online sample extractions. The improved mass-transfer rate characteristic of turbulent flow allows fast sample cleanup without decreased extraction efficiency. The novel use of the RAM column, connected upstream to a C18 monolithic column, allowed the direct injection, extraction, separation, and MS/MS detection of plasma samples spiked with rofecoxib in a span of 5 min. Calibration curves obtained using this RAM turbulent flow coupled column method showed good linearity (R2 > 0.99) and reproducibility (%RSD < or = 7%). The lower limit of quantitation of rofecoxib in plasma samples was found to be 40 ng/ml. The extraction method showed good recovery of rofecoxib from a plasma matrix with minimal signal loss and robustness after more than 200 plasma injections.

Chromatography, High Pressure Liquid↗

Stir bar sorptive extraction based on restricted access material for the direct extraction of caffeine and metabolites in biological fluids.

A biocompatible stir bar sorptive extraction (SBSE) device was prepared using an alkyl-diol-silica (ADS) restricted access material (RAM) as the SBSE coating. The RAM-SBSE bar was able to simultaneously fractionate the protein component from a biological sample, while directly extracting caffeine and its metabolites, overcoming the present disadvantages of direct sampling in biological matrices by SBSE, such as fouling of the extraction coating by proteins. Desorption of the analytes was performed by stirring the bar in a water/ACN mixture (3/1, v/v) and subsequently reconcentrating the sample solution in water to enable HPLC-UV analysis to be performed. The limit of detection, based on a signal to noise ratio of 3, for caffeine was 25 ng/mL in plasma. The method was confirmed to be linear over the range of 0.5-100 microg/mL of caffeine with an average linear coefficient (R2) value of 0.9981. The injection repeatability and intra-assay precision of the method were evaluated over ten injections, resulting in a %RSD of approximately 8%. The RAM-SBSE device was robust (>50 extraction in plasma without significant signal loss) and simple to use, providing many direct extractions and subsequent determination of caffeine and its metabolites in biological fluids. In contrast to existing sample preparation methods for the analysis of caffeine and selected metabolites in biological fluids, this feasibility study using a biocompatible SBSE approach was advantageous in terms of simplifying the sample preparation procedures.

Caffeine↗

Approaches for coupling solid-phase microextraction to nanospray.

Biocompatible solid-phase microextraction (SPME) devices were prepared using two restricted access materials (RAM) as the SPME coating. The restricted access materials were immobilized on steel and platinum wires. The selective coating eliminated most of the matrix interference, which allowed the coupling to mass spectrometry without further purification. The SPME devices were interfaced to mass spectrometry by electronanospray. Several experimental set-ups are described and discussed herein. For the in situ extraction of peptides from the tryptic digests, trypsin was immobilized both on steel wires and on the inside wall of a vial. The devices were incubated together with the RAM-SPME devices and a protein (casein) solution. After the protein digestion, the resulting peptides were analyzed by SPME/nanospray. The vial approach provided the best results; up to eight peptides could be identified which corresponds to a sequence coverage of 58%. The limit of detection of SPME/nanospray for the extraction of peptides from an aqueous solution was about 50 fmol/mL. The results demonstrate that the direct coupling of SPME to nanospray can reduce analysis time and is an attractive alternative to conventional approaches like Zip-Tip purification.

Amino Acid Sequence↗

A silica-based monolithic column in capillary HPLC and CEC coupled with ESI-MS or electrospray-atmospheric-pressure laser ionization-MS.

We describe the successful coupling of CEC and capillary HPLC with the recently developed atmospheric-pressure laser ionization (APLI) method. APLI is suitable for selectively and sensitively ionizing nonpolar aromatic compounds at ambient pressure for subsequent mass-selective detection. The polycyclic aromatic hydrocarbons used as analytes are first separated either by CEC on a silica-based monolithic column or by capillary HPLC. The eluent, along with a sheath flow, is volatilized by microelectrospray and then selectively ionized by excimer laser (KrF*) radiation via two-photon excitation. A QTOF-MS is used as mass-selective detector. This interface combination makes soft ionization of thermally labile nonpolar aromatic analytes possible.

Chromatography, High Pressure Liquid↗

Monolithic silica columns with chemically bonded tert-butylcarbamoylquinine chiral anion-exchanger selector as a stationary phase for enantiomer separations.

An enantioselective silica rod type chiral stationary phase (CSP) is presented as a novel combination of the well-known enantiomer separation properties of immobilized tert-butyl-carbamoylquinine chiral anion-exchanger selector with the unique properties of monolithic silica material. The chromatographic behavior of the tert-butyl-carbamoylquinine silica rod was studied and compared with a similar prepared particulate material. Good selectivities were achieved for a spectrum of chiral test components like N-derivatized amino acids (DNB- Ac-, DNZ-, Bz-, Z-amino acids) and for Suprofen. The influence of mobile phase parameters, as well as the effect of serially coupling up to six 10 cm monolithic silica columns was studied and put in context to conventional columns of particulate 5 microm type CSP. Using that 60 cm long monolithic column it was possible to improve the enantiomer separation of Suprofen and achieve a baseline separation in less than 10 min of total separation time.

Anion Exchange Resins↗

Evaluation and comparison of tailor-made stationary phases based on spherical silica-based beads for capillary electrochromatography via peptide separation analysis.

Small cyclic peptides have been employed to elucidate the performance of novel sorbents as stationary phases in capillary electrochromatography (CEC). In this paper chain length dependencies for ordinary liquid chromatographic sorbents are reported together with findings acquired on beads specifically designed to suit CEC. The latter, tailor-made, spherical, porous silica exhibits a distinguished surface modification to meet the criteria anticipated to enhance performance profiles in CEC. With well-characterised peptides resembling the analytes, probing of the CEC system in a systematic manner (predominantly via the organic modifier content of the background electrolyte (BE)) reveals insight into the complex interplay occurring in such analytical systems at the molecular and sub-molecular level in particular upon various modes of interaction.

Amino Acid Sequence↗

Enantioselective hydrolysis of some 2-aryloxyalkanoic acid methyl esters and isosteric analogues using a penicillin G acylase-based HPLC monolithic silica column.

A technique based on liquid chromatography has been developed to facilitate studies of enantioselectivity in penicillin G acylase (PGA)-catalyzed hydrolysis of some 2-aryloxyalkanoic acid methyl esters and isosteric analogues. PGA was covalently immobilized on an aminopropyl monolithic silica support to create an immobilized HPLC-enzyme reactor. Two sets of experimental data were drawn to calculate the enantioselectivity (E) of the kinetically controlled enantiomer-differentiating reaction, the degree of substrate conversion and the enantiomeric excess of the product. The developed enzymatic reactor was coupled through a switching valve to an achiral analytical column for separation and quantitation of the hydrolysis products. The enantiomeric excess was determined off-line on a PGA-chiral stationary phase. In this way, highly precise E values were determined. A computational study related to the hydrolysis of the considered racemic esters was also carried out in order to unambiguously clarify both the substrate specificity and the enantioselectivity displayed by PGA.

Catalysis↗

Silica-based monoliths for rapid peptide screening by capillary liquid chromatography hyphenated with electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry.

Capillary liquid chromatography based on particulate and monolithic stationary phases was used to screen complex peptide libraries by fast gradient elution coupled on-line to electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS). A slightly modified commercial electrospray interface consisting of a fused-silica transfer capillary and low dead volume stainless steel union at which the electrospray voltage was grounded enabled the effluent of all the capillary columns to be directly sprayed into the mass spectrometer. Stable electrospray conditions were generated over a wide range of mobile phase compositions, alleviating the need for a tapered end of the spray capillary, pneumatic assistance or preheated nebulizer gas. Since the identification of complex samples containing numerous isobaric substances is facilitated by chromatographic separation prior to mass spectrometry, stationary phase materials have been employed which offer a fast, efficient elution and, due to the complexity of samples, a high loading capacity. Silica-based monolithic capillary columns combine these three characteristics in a unique manner due to a tailored adjustment of both macro- and mesopore sizes in the highly porous silica structure. As we demonstrate by a comparative study of the silica-based monolithic and packed capillaries for LC/MS analysis of complex peptide libraries, silica monoliths show superior performance over packed beds of small-diameter particles with respect to analysis time and separation efficiency. Libraries with more than 1000 different peptides could be screened in less than 20 min.

Chromatography, Liquid↗

Bio-compatible in-tube solid-phase microextraction capillary for the direct extraction and high-performance liquid chromatographic determination of drugs in human serum.

A restricted access material (RAM), alkyl-diol-silica (ADS), was used to prepare a highly bio-compatible solid-phase microextraction (SPME) capillary for the automated and direct in-tube extraction of several benzodiazepines from human serum. The bifunctionality of the ADS extraction phase prevented fouling of the capillary by protein adsorption while simultaneously trapping the analytes in the hydrophobic porous interior. This the first report of a restricted access material utilized as an extraction phase for in-tube SPME. The approach simplified the required apparatus in comparison to existing RAM column switching procedures, and more importantly eliminated the excessive use of extraction solvents. The biocompatibility of the ADS material also overcame the existing problems with in-tube SPME that requires an ultrafiltration or other deproteinization step prior to handling biological samples, therefore further minimizing the sample preparation requirements. The calculated oxazepam, temazepam, nordazepam and diazepam detection limits were 26, 29, 22 and 24 ng/ml in serum, respectively. The method was linear over the range of 50-50 000 ng/ml with an average linear coefficient (R2) value of 0.9998. The injection repeatability and intra-assay precision of the method were evaluated with five injections of a 10-microg/ml serum sample (spiked with all compounds), resulting in an average RSD<7%. The ADS extraction column was robust, providing many direct injections of biological fluids for the extraction and subsequent determination of benzodiazepines.

Benzodiazepines↗

Characterization of silica-based monoliths with bimodal pore size distribution.

Band dispersion was studied and the retention thermodynamics addressed for insulin and angiotensin II on C18 silica monoliths with a bimodal pore size distribution, covering linear mobile-phase velocities up to 1 cm/s and different temperatures. These data suggest that the influence of average column pressure on retention (between 0 and 10 MPa) is not negligible. Plate height curves were interpreted with the van Deemter equation by assuming an independent contribution from mechanical and non-mechanical dispersion mechanisms. This analysis revealed diffusion-limited mass transfer in the mesoporous silica skeleton which, in turn, allowed us to calculate an equivalent dispersion particle diameter (d(disp) = 3 microm) using the C-term parameter of the van Deemter equation. The resulting superposition of reduced plate height curves for monolithic and particulate beds confirmed that this view presents an adequate analogy. The macroporous interskeleton network responsible for the hydraulic permeability of a monolith was translated to the interparticle pore space of particulate beds, and an equivalent permeability particle diameter (d(perm) = 15 microm) was obtained by scaling based on the Kozeny-Carman equation.

Journal Article↗