Bipolar radiofrequency ablation using internally cooled electrodes in ex vivo bovine liver: prediction of coagulation volume from applied energy.

OBJECTIVE: We sought to evaluate the relationship between parameters of bipolar radiofrequency (RF) ablation using internally cooled electrodes. MATERIALS AND METHODS: Bipolar RF ablations (n = 24) were performed in ex vivo bovine liver using an internally cooled applicator with 2 electrodes located on the same shaft. The power-output was systematically varied (20-75 W). On the basis of our experimental data, mathematical functions were fitted and the goodness-of-fit was assessed by the parameter R. RESULTS: The duration to induce an increase of tissue resistance and the amount of applied energy increased with a decreased power-output. The maximum short-axis was 4.5 cm (20 W) and required an application of 64 kilojoules (kJ). The volume of coagulation can be determined as a function of the duration of energy application (R = 0.954) and the amount of applied energy (R = 0.945). CONCLUSION: The amount of applied energy and the duration of energy application can predict the volume of induced coagulation and may be useful to control internally cooled bipolar RF ablation.

Animals↗

Multipolar radiofrequency ablation with internally cooled electrodes: experimental study in ex vivo bovine liver with mathematic modeling.

PURPOSE: To evaluate the size and geometry of thermally induced coagulation by using multipolar radiofrequency (RF) ablation and to determine a mathematic model to predict coagulation volume. MATERIALS AND METHODS: Multipolar RF ablations (n = 80) were performed in ex vivo bovine livers by using three internally cooled bipolar applicators with two electrodes on the same shaft. Applicators were placed in a triangular array (spacing, 2-5 cm) and were activated in multipolar mode (power output, 75-225 W). The size and geometry of the coagulation zone, together with ablation time, were assessed. Mathematic functions were fitted, and the goodness of fit was assessed by using r(2). RESULTS: Coagulation volume, short-axis diameter, and ablation time were dependent on power output and applicator distance. The maximum zone of coagulation (volume, 324 cm(3); short-axis diameter, 8.4 cm; ablation time, 193 min) was induced with a power output of 75 W at an applicator distance of 5 cm. Coagulation volume and ablation time decreased as power output increased. Power outputs of 100-125 W at applicator distances of 2-4 cm led to a reasonable compromise between coagulation volume and ablation time. At 2 cm (100 W), coagulation volume, short-axis diameter, and ablation time were 66 cm(3), 4.5 cm, and 19 min, respectively; at 3 cm (100 W), 90 cm(3), 5.2 cm, and 22 min, respectively; at 4 cm (100 W), 132 cm(3), 6.1 cm, and 27 min, respectively; at 2 cm (125 W), 56 cm(3), 4.2 cm, and 9 min, respectively; at 3 cm (125 W), 73 cm(3), 4.9 cm, and 12 min, respectively; and at 4 cm (125 W), 103 cm(3), 5.5 cm, and 16 min, respectively. At applicator distances of 4 cm (>125 W) and 5 cm (>100 W), the zones of coagulation were not confluent. Coagulation volume (r(2) = 0.80) and RF ablation time (r(2) = 0.93) were determined by using the mathematic model. CONCLUSION: Multipolar RF ablation with three bipolar applicators may produce large volumes of confluent coagulation ex vivo. A compromise is necessary between prolonged RF ablations at lower power outputs, which produce larger volumes of coagulation, and faster RF ablations at higher power outputs, which produce smaller volumes of coagulation.

Animals↗

MR-guided radiofrequency ablation: do magnetic fields influence extent of coagulation in ex vivo bovine livers?

PURPOSE: To prospectively determine if static magnetic fields of magnetic resonance (MR) imagers affect radiofrequency (RF) ablation coagulation volume and shape. MATERIALS AND METHODS: Ex vivo RF ablations of bovine livers were performed with magnetic field strengths of 0.2, 1.5, and 3.0 T and were compared with ablations performed outside the magnetic field in a control group. Two MR-compatible monopolar RF devices (internally cooled single and cluster electrodes) were systematically tested. Length of long axis (y-axis), length of two short axes (x- and z-axes), and coagulation volume and shape measured outside and inside different magnetic fields were compared with the Dunnett test. Significance level was set to .05. RESULTS: For the single electrode, no significant difference was observed between length of short axes and coagulation volume and shape measured inside and outside the magnetic field. Mean x- and z-axis lengths were 2.3 and 2.6 cm, respectively, outside the magnetic field; 2.4 and 2.4 cm, respectively, at 0.2 T; 2.5 and 2.6 cm, respectively, at 1.5 T; and 2.2 and 2.5 cm, respectively, at 3.0 T. Differences between length of long axis, length of short axis perpendicular to static magnetic field, and coagulation volume and shape achieved with the cluster electrode inside and outside the magnetic field were not significant. Mean x- and z-axis lengths were 3.9 and 3.9 cm, respectively, outside the magnetic field; 3.7 and 3.8 cm, respectively, at 0.2 T; 4.0 and 4.3 cm, respectively, at 1.5 T; and 3.8 and 3.8 cm, respectively, at 3.0 T. Differences between ablations performed at 1.5 T and those performed in the control group with the cluster electrode were significant (P = .026). In this case, a difference of 4 mm in the length of the short axis parallel to the magnetic field was detected, but there was no significant difference in coagulation volume. CONCLUSION: No significant differences in coagulation volume and shape could be recorded between RF ablations performed outside and those performed inside the static magnetic field.

Animals↗

Percutaneous MR-guided radiofrequency ablation of recurrent sacrococcygeal chordomas.

OBJECTIVE: Radiofrequency ablation is emerging as a therapeutic technique for the treatment of an increasing variety of tumors. Exact visual guidance to the tumor and controlled delivery of energy is pivotal for ablation success. CONCLUSION: Introducing MRI as a guidance technique ideally uses tumor-specific tissue characteristics, allows direct multiplanar reconstruction for precise needle positioning, and permits real-time monitoring and assessment of treatment-induced tissue signal changes to increase the safety of the procedure.

Aged↗

Magnetic susceptibility effects on the accuracy of MR temperature monitoring by the proton resonance frequency method.

PURPOSE: To evaluate the error of MR temperature assessment based on the temperature-dependent Larmor frequency shift of water protons, which can result from susceptibility effects caused by the radiofrequency (RF) applicator. MATERIALS AND METHODS: Local frequency shifts due to RF applicator displacements were simulated numerically by means of a three-dimensional elementary dipole model. Experimental examinations using a water tank phantom equipped with a high-precision screw thread were applied to examine temperature and movement effects for five commercially available, MR-compatible RF applicators. Measurements were performed at 1.5 Tesla. RESULTS: For single-needle electrodes perpendicular to the external field, a distortion of 0.1 ppm and 0.2 ppm was recorded at a distance of 17.5 mm and 12.5 mm, respectively, to the needle shaft. Cluster applicators and umbrella-shaped applicators caused distortions of 0.1 ppm up to distances of 36 mm. Sinusoidal dependence on applicator orientation was found with the highest values for perpendicular orientation and the lowest values for orientation parallel to the magnetic field. With a single electrode oriented perpendicular to the field at a distance of 1.5 cm and 2.0 cm, a needle displacement of 5 mm led to an error in temperature measurement of 16.3 degrees C and 7.5 degrees C, respectively. CONCLUSION: In MR temperature measurement, displacement of the RF applicator by patient movement or breathing leads to significant errors that have to be taken into account when PRF temperature maps are used to monitor tumor ablation in the presence of paramagnetic applicators.

Catheter Ablation↗

Magnetic resonance-guided percutaneous radiofrequency ablation of renal cell carcinomas: a pilot clinical study.

OBJECTIVE: The objective of this study was to assess the feasibility and efficacy of magnetic resonance imaging-(MRI) guided percutaneous radiofrequency (RF) ablation of renal cell carcinomas (RCC). SUBJECTS AND METHODS: Twelve patients with RCC (63 to 82 years old) were treated with RF ablation in an interventional 0.2-Tesla open MR unit. Tumor sizes varied from 1.6 cm to 3.9 cm in maximum diameter (tumor volumes 1.9 cm3 to 28.7 cm3). RF procedures were entirely performed in the MR suite. For positioning of the MR-compatible RF-electrode, near real-time MR fluoroscopy by means of rapid gradient echo sequences (acquisition time approximately 2 seconds) was used. Monitoring of ablation was obtained by intermittent imaging with T1- and T2-weighted spin echo sequences. RESULTS: Accurate placement of the RF electrodes was possible in all cases using near real-time MR fluoroscopy. Eleven of 12 patients were successfully treated within 1 single session; 1 patient had to be retreated for tumor relapse at 13 months follow up. Mean number of electrode repositionings under MR guidance during 1 session was 1.7; ablation time ranged between 12 and 28 minutes. Mean duration of 1 treatment session was 5 hours. Coagulation volumes ranged from 7.3 cm3 up to 30.2 cm3. All patients now appear to be disease-free with a mean follow up of 10.3 months (range, 3-23 months). CONCLUSION: MRI-guided RF ablation of RCC in an interventional MR unit is safe and feasible. Fast MR imaging is a convenient method for rapid positioning of MR-compatible RF electrodes. MR monitoring of ablation procedure with T2-weighted imaging allows for immediate assessment of coagulation extent.

Aged↗

Thermal damage of the genitofemoral nerve due to radiofrequency ablation of renal cell carcinoma: a potentially avoidable complication.

OBJECTIVE: A technique is presented that may prevent damage to the genitofemoral nerve during percutaneous radiofrequency ablation of renal cell carcinomas. The genitofemoral nerve originates from the upper part of the lumbar plexus and descends laterally along the psoas major muscle, which is anatomically close to the kidney. During radiofrequency ablation, nearby healthy nerve tissue could be damaged by heat conductance. In the described technique, the radiofrequency applicator within the renal tumor is used as a lever to displace the kidney away from the psoas muscle. CONCLUSION: Three clinical cases are presented in this study. In one case, the technique was not applied, leading to coagulation of the genitofemoral nerve. In the other two cases, hazard to the genitofemoral nerve was averted by using the mentioned technique.

Aged↗

Magnetic resonance imaging characteristics of six radiofrequency electrodes in a phantom study.

PURPOSE: To evaluate and compare visibility and artifacts in magnetic resonance (MR) compatible radiofrequency (RF) electrodes for MR-guided RF ablation. MATERIAL AND METHODS: Six different MR compatible electrodes for RF ablation including two internally cooled single needles, one internally cooled cluster needle, two expandable needles and one perfused needle were tested in a phantom study at 0.2 Tesla and at 1.5 Tesla field strength. Fluoroscopic, T1- and T2-weighted fast spin echo (FSE) and gradient echo (GE) sequences, which are usually used for MR-guided interventions, were evaluated. Qualitative and quantitative evaluations were performed. Length, width, noise, tip artifacts, global artifacts and global visualization of the RF electrodes that showed all sequences at different angles. RESULTS: Qualitative analysis showed that electrodes were well visualized at all angles and sequences and on both MR imagers. Quantitative analysis showed that artifact-induced widening of the shaft was increased in all electrodes by: a). use of fluoroscopic sequences, GE sequences, and fat saturation, b). increasing the angle between the needle and main magnetic field, and c). high field strength (1.5 T). Expandable needles produced fewer tip artifacts but broader signal voids along the shaft compared to nonexpandable needles. Cluster electrodes produced less widening than the other electrodes. CONCLUSION: Visibility and artifacts in all six MR compatible RF electrodes are satisfactory and these electrodes could be used for MR-guided radiofrequency ablation procedures.

Artifacts↗

Radiofrequency ablation: in vivo comparison of four commercially available devices in pig livers.

PURPOSE: To compare in vivo coagulation necrosis obtained with four radiofrequency (RF) ablation devices, to determine shape and reproducibility of induced coagulation by means of three-dimensional measurements of the ablation zone, and to achieve representations of the coagulated areas in three-dimensional spaces. MATERIALS AND METHODS: Four commercially available RF devices (perfusion, internally cooled cluster, and nine- and 12-tine expandable electrodes) that represent the most widely used systems on the market were tested. Sixteen in vivo ablation procedures were performed in porcine livers (four ablations for each RF system). After macroscopic and histopathologic analyses of 3-mm-thick liver sections, morphometric and volumetric findings in the central zone of white coagulation necrosis were assessed. Coagulation volume, diameter, length, and shape were determined digitally. After analysis of variance, measurements with each system were tested with the Tukey post hoc test. RESULTS: Mean coagulation volumes were 31.5 cm3 +/- 15.8 (SD) for the perfusion electrode, 20.5 cm3 +/- 2.6 for the cluster electrode, 16.2 cm3 +/- 7.3 for the 12-tine electrode, and 9.8 cm3 +/- 3.2 for the nine-tine electrode (P <.05, perfusion vs nine-tine electrode). No significant differences were observed regarding the mean short axis perpendicular to the needle shaft: 2.30 cm +/- 0.94, 3.04 cm +/- 0.26, 3.44 cm +/- 0.21, and 2.70 cm +/- 0.76, respectively. Variation coefficients were 0.50, 0.13, 0.45, and 0.33, respectively. CONCLUSION: Larger coagulation volumes were obtained with the perfusion and internally cooled cluster devices. More spherical volumes of ablation were achieved with the 12-tine and cluster electrodes. The former proved superior with regard to the short axis perpendicular to the needle shaft. The cluster and nine-tine electrode produced better reproducibility, which is suggestive of improved predictability of the extent of coagulation with these systems.

Animals↗

In vivo efficiency of four commercial monopolar radiofrequency ablation systems: a comparative experimental study in pig liver.

RATIONALE AND OBJECTIVES: To evaluate the efficiency of 4 radiofrequency (RF) systems by assessing the amount of delivered energy for each thermal induced lesion after perfusion mediated RF ablation and to compare the influence of perfusion mediation types on the energy efficiency. METHODS: A total of 43 ablations in 16 male landrace pigs with 4 RF devices were performed strictly according to the manufacturers' instructions. Total absorbed energy was computed and then related to 3D volumetry obtained after histopathological evaluation. Sixteen ablations were performed under physiological liver perfusion and 27 ablations with occlusion of portal vein, hepatic artery, or both vessels. Energy efficiency values of the RF systems for different vascular occlusion techniques were compared and analyzed by a nonparametrical rank sum test. RESULTS: Under physiological perfusion, the average energy delivered to produce 1-cm3 lesion size was calculated to 1650 +/- 929, 3097 +/- 389, 8312 +/- 2068, and 5493 +/- 2306 Watt x s/cm3 for the Berchtold, Radionics, Radiotherapeutics, and RITA system, respectively. After perfusion-mediated RF ablation, artery occlusion was not as effective as portal vein occlusion, which reduced the energy to 587 +/- 148, 869 +/- 276, and 903 +/- 394 Watt. s/cm3 for the Berchtold, Radionics, and Radiotherapeutics system, respectively. The occlusion of vessels, portal vein, and artery or portal vein alone increased the energy efficiency compared with physiological liver perfusion or occlusion of the artery (P = 0,003). CONCLUSIONS: Under physiological liver perfusion the open perfused system and the internally cooled system provided the best efficiency values with lowest standard deviations. The energy efficiency was increased markedly for all systems after occlusion of the portal vein either alone or in combination with arterial occlusion. Occlusion of the hepatic artery did not improve the efficiency.

Animals↗

Influence of NaCl concentrations on coagulation, temperature, and electrical conductivity using a perfusion radiofrequency ablation system: an ex vivo experimental study.

PURPOSE: To determine, by means of an ex vivo study, the effect of different NaCl concentrations on the extent of coagulation obtained during radiofrequency (RF) ablation performed using a digitally controlled perfusion device. METHOD: Twenty-eight RF ablations were performed with 40 W for 10 min using continuous NaCl infusion in fresh excised bovine liver. For perfusion, NaCl concentrations ranging from 0 (demineralized water) to 25% were used. Temperature, the amount of energy, and the dimensions of thermal-induced white coagulation were assessed for each ablation. These parameters were compared using the nonparametric Mann-Whitney test. Correlations were calculated according to the Spearman test. RESULTS: RF ablation performed with 0.9% to 25% concentrations of NaCl produced a mean volume of coagulation of 30.7 +/- 3.8 cm(3), with a mean short-axis diameter of 3.6 +/- 0.2 cm. The mean amount of energy was 21,895 +/- 1,674 W and the mean temperature was 85.4 +/- 12.8 degrees C. Volume of coagulation, short-axis diameter, and amount of energy did not differ significantly among NaCl concentrations (p > 0.5). A correlation was found between the NaCl concentration and the short-axis diameter of coagulation (r = 0.64) and between the NaCl concentration and the mean temperature (r = 0.67), but not between the NaCl concentration and volume of coagulation. CONCLUSION: In an ex vivo model, continuous perfusion with high NaCl concentrations does not significantly improve the volume of thermal-induced coagulation. This may be because the use of a low-power generator cannot sufficiently exploit the potential advantage of better tissue conductivity provided by NaCl perfusion.

Animals↗