The dose-area product, a new parameter for the dosimetry of narrow photon beams.

In the dosimetry of narrow photon fields with side lengths of the order of 1 cm, the traditional parametrisation via the absolute dose on the beam axis and the relative lateral dose distribution has to deal with the difficulty to find sufficiently small detectors and to adjust them accurately on the narrow-beam axis. This can be avoided by reconsidering the parametrisation, using as normalization factor the surface integral of the dose in the plane perpendicular to the beam axis, abbreviated as the "dose-area product" (DAP). We investigated and confirmed the ability of a large-area parallel-plate ionisation chamber, with a sensitive volume shaped as a flat cylinder of 81.6 mm diameter and 2 mm thickness, to perform the integration over the full lateral dose profile of narrow photon beams with side lengths up to 5 cm. The lateral adjustment of this large-area detector relative to a narrow photon beam is not critical. The large-area ionisation chamber was calibrated in terms of the DAP by reference to a 0.3 cm3 ionisation chamber. A field-size dependent "modified output factor" was defined as the ratio of the DAP measured at 5 cm phantom depth for 100 cm SSD, and the monitor reading. A prominent phenomenon of narrow photon fields is the field-size and source-distance independence of the relative axial profile of the DAP as function of the thickness of a pre-absorber or of the depth in a phantom. For narrow-beam treatment planning in IMRT, the DAP is combined with the energy- and field size-dependent relative lateral dose distribution which is represented, for example, by a Gaussian convolution kernel. Another useful feature of the DAP is the possibility of its direct control during patient irradiation by means of an on-line monitor with spatial resolution, arranged in the accessory holder.

Calibration↗

Two-dimensional ionization chamber arrays for IMRT plan verification.

In this paper we describe a concept for dosimetric treatment plan verification using two-dimensional ionization chamber arrays. Two different versions of the 2D-ARRAY (PTW-Freiburg, Germany) will be presented, a matrix of 16 x 16 chambers (chamber cross section 8 mm x 8 mm; the distance between chamber centers, 16 mm) and a matrix of 27 x 27 chambers (chamber cross section 5 mm x 5 mm; the distance between chamber centers is 10 mm). The two-dimensional response function of a single chamber is experimentally determined by scanning it with a slit beam. For dosimetric plan verification, the expected two-dimensional distribution of the array signals is calculated via convolution of the planned dose distribution, obtained from the treatment planning system, with the two-dimensional response function of a single chamber. By comparing the measured two-dimensional distribution of the array signals with the expected one, a distribution of deviations is obtained that can be subjected to verification criteria, such as the gamma index criterion. As an example, this verification method is discussed for one sequence of an IMRT plan. The error detection capability is demonstrated in a case study. Both versions of two-dimensional ionization chamber arrays, together with the developed treatment plan verification strategy, have been found to provide a suitable and easy-to-handle quality assurance instrument for IMRT.

Computer-Aided Design↗

[Resolution and sensitivity of a two-dimensional ionisation chamber array (PTW type 10024)].

The two-dimensional verification of intensity-modulated radiation plans is one of the major requirements for the safe application of this technique. The present study examines the resolution and sensitivity of a two-dimensional ionisation-chamber array (PTW2D-Array, type 10024), which can be used for plan verification instead of films. According to the Shannon-Nyquist theorem, the resolution of the 2D-Array is sufficient for dose distributions with a minimal field size of 2 cm x 2 cm. The minimal field size can be reduced to 1 cm x 1 cm by shifting the array 5 mm in the direction of the MLC movement and by repeating the measurements. The high sensitivity against a monitor decalibration for a single field of a sequence is demonstrated on the basis of an individual case. The minimal threshold for MLC misalignment detected by a chamber of the array is less than 1 mm. Therefore, the resolution capabilities of the 2D-Array are sufficient for most intensity-modulated radiation therapy (IMRT)fields.

Humans↗

Dosimetric characteristics of a new unshielded silicon diode and its application in clinical photon and electron beams.

Shielded p-silicon diodes, frequently applied in general photon-beam dosimetry, show certain imperfections when applied in the small photon fields occurring in stereotactic or intensity modulated radiotherapy (IMRT), in electron beams and in the buildup region of photon beam dose distributions. Using as a study object the shielded p-silicon diode PTW 60008, well known for its reliable performance in general photon dosimetry, we have identified these imperfections as effects of electron scattering at the metallic parts of the shielding. In order to overcome these difficulties a new, unshielded diode PTW 60012 has been designed and manufactured by PTW Freiburg. By comparison with reference detectors, such as thimble and plane-parallel ionization chambers and a diamond detector, we could show the absence of these imperfections. An excellent performance of the new unshielded diode for the special dosimetric tasks in small photon fields, electron beams and build-up regions of photon beams has been observed. The new diode also has an improved angular response. However, due to its over-response to low-energy scattered photons, its recommended range of use does not include output factor measurements in large photon fields, although this effect can be compensated by a thin auxiliary lead shield.

Biophysical Phenomena↗

[Improvement of the accuracy of the Laplace transform method for the determination of radiotherapy spectra of clinical linear accelerators].

The present study focused on the reconstruction of the bremsstrahlung spectrum of a clinical linear accelerator from the measured transmission curve, with the aim of improving the accuracy of this method. The essence of the method was the analytic inverse Laplace transform of a parameter function fitted to the measured transmission curve. We tested known fitting functions, however they resulted in considerable fitting inaccuracy, leading to inaccuracies of the bremsstrahlung spectrum. In order to minimise the fitting errors, we employed a linear combination of n equations with 2n-1 parameters. The fitting errors are now considerably smaller. The measurement of the transmission function requires that the energy-dependent detector response is taken into account. We analysed the underlying physical context and developed a function that corrects for the energy-dependent detector response. The factors of this function were experimentally determined or calculated from tabulated values.

Models, Theoretical↗