PubMed Health⌕ Search

Biomedical subjects

Dilip Kittur

Publications and source records attributed to Dilip Kittur.

7 recordsLinked to original sources

Resident perceptions of the impact of work-hour restrictions on health care delivery and surgical education: time for transformational change.

BACKGROUND: The Accreditation Council for Graduate Medical Education has recently enacted an 80-hour workweek, which has been in effect in New York State for several years. We surveyed surgical residents from all four State University of New York (SUNY) surgical programs to determine their perceptions of the impact of the 80-hour workweek on patient care, surgical education, and personal life. METHODS: A survey instrument to address the three areas of concern was developed and administered to all surgical residents at the four SUNY programs. Anonymity of the responders was maintained. Responses to the questions were in numeric rank scores and were analyzed by descriptive statistics, chi-square analysis, and analysis of variance. RESULTS: Response rate was 59%. Factors perceived to be affected negatively by the residents were continuity and safety of care, their operative experience, and their relations with attendings. The factors affected positively were increased personal time and decreased fatigue at work. Interestingly, the latter did not appear to decrease the rate of medical errors in their perception. CONCLUSIONS: The 80-hour workweek has the potential to have adverse effects on patient care despite improving the level of fatigue at work. Reengineering the surgical residencies will be needed to take full advantage of the restricted work hours.

Delivery of Health Care↗

Signal transduction pathway in endothelial dysfunction.

BACKGROUND: Endothelial dysfunction is an important feature of sepsis, acute respiratory distress syndrome (ARDS), and other infectious conditions. Previously, we reported an in vitro model to study endothelial dysfunction, in which endothelial cells are induced to form capillary tube networks by culturing on a basement membrane matrix (Matrigel). In this study, we defined the signal transduction pathways that lead to endothelial cell function and capillary disruption characteristic of sepsis and other infectious conditions. METHODS: Human aortic endothelial cells (HAEC) were cultured on a laminin-rich matrix to form capillary-like networks. The HAECs were treated with a protein tyrosine phosphatase inhibitor (sodium orthovanadate), a phosphoinositon-3-phosphate inhibitor (wortmannin), or a protein kinase C inhibitor (bisindolylmaleimide) before capillary tubes had formed or after the capillary tubes had matured. The degree of capillary tube formation was quantified by counting the intersection of capillary networks in triplicate wells. Statistical significance was determined by analysis of variance. RESULTS: Endothelial dysfunction occurred after inhibition of protein tyrosine phosphatase or protein kinase C. Whereas inhibition of phosphoinositon-3-phosphate did not cause endothelial dysfunction, sodium orthovanadate (2-20 microM) and bisindolylmaleimide (2-10 microM) significantly reduced capillary networks. The mean +/- SD of the number of capillary tubes in the control, sodium orthovanadate-treated, and bisindolylmaleimide-treated groups were 251.0 +/- 7.0, 65.6 +/- 9.9 (p < 0.001), and 181.7 +/- 0.1 (p < 0.001), respectively. Sodium orthovanadate (20-200 microM) and bisindolylmaleimide (10-100 microM) inhibited capillary tube formation. At higher concentrations, sodium orthovanadate (> 200 microM) and bisindolylmaleimide (>100 microM) disrupted mature capillary tubes. CONCLUSIONS: Our results suggest that PKC and protein tyrosine phosphatase play a role in endothelial dysfunction by interfering with the phosphorylation signals within endothelial cells. These mechanisms may be important in the endothelial dysfunction in sepsis and other infectious conditions.

Analysis of Variance↗

Soluble interleukin 2 receptor (sIL-2R) levels in renal transplant recipients.

BACKGROUND: Allograft rejection is associated with T cell activation. T cell activation leads to secretion of soluble IL-2 receptor and elevated serum soluble IL-2 receptor (sIL-2R) levels. However, the clinical implication of individual elevated sIL-2 receptor levels is unclear. We followed levels of sIL-2R pre- and post-transplantation to determine if sIL-2R levels predict rejection episodes or degree of graft function. MATERIALS AND METHODS: Serum samples of 12 patients who underwent living or cadaveric renal transplant were followed weekly with serial sIL-2R levels. These levels were followed until the serum creatinine reached a baseline. Of the 12 patients, three patients developed delayed graft function. The remaining nine patients were followed for a period of 3 months. Sera of these nine patients in the initial 3 months post-transplant were monitored for sIL-2R levels. For comparison, sIL-2R levels were also measured in 150 healthy volunteers and five dialysis patients. RESULTS: Recipients undergoing severe rejection episodes had higher overall serum levels of sIL-2R (1515 +/- 496 U/mL) as compared with recipients who had stable renal transplants and no episodes of rejection (698 +/- 333 U/mL) (P = 0.034). Comparison of sIL-2R ratios (post-transplant sIL-2R level/pre-transplant sIL-2R level) revealed that ratios of 0.6 or higher were more frequently seen in patients who subsequently underwent severe rejection episodes. Dialysis patients were found to have higher sIL-2R levels (2605 +/- 1312 U/mL) compared with renal transplant patients (1047 +/- 192 U/mL) (P < 0.001) and healthy volunteers (349 +/- 185 U/mL) (P < 0.001). CONCLUSION: Our results suggest that individual levels of sIL-2R are not predictive of rejection in the early post-transplant period, but s-IL2R ratios greater than 0.6 may be predictive of severe rejection episodes.

Graft Rejection↗

Cross-species comparison of gene expression between human and porcine tissue, using single microarray platform--preliminary results.

INTRODUCTION: Xenotransplantation is a potential solution for inadequate supply of donor organs. Pigs are considered the ideal donor for kidney transplantation to human recipients, therefore it is important to understand the gene regulation in the porcine organs. Oligonucleotide array technology has been utilized largely for human, mouse and rat gene expression studies only. Its use with porcine genes has not been reported. We investigated the possibility of studying gene regulation in porcine kidney with a human GeneChip microarray platform. METHODS: To assess the feasibility of using a single microarrray platform for comparison of expressing data across different species (human and pig), we compared the gene expression profiles of human brain, human kidney and pig kidney using the Affymetrix U-133 A human GeneChip, which contains probes for 22,283 genes. Kidney biopsies from pigs and humans, with normal histology, were used to obtain RNA for porcine and human samples, while a commercially available adult whole cortex total RNA sample (Clontech) was used for the human sample. We assessed the intensity ratio for housekeeping and tissue specific genes. To examine the potential for non-specific binding to create false positive errors in our data, we compared the expression profiles in our experiments to a number of public databases. RESULTS: There were approximately the same number of genes expressed at higher levels in the pig kidney as in the human kidney and human brain. The major differences in gene expression were found for genes with tissue specific patterns of expression. Eighty genes were increased in human brain vs. human and pig kidney samples. Two hundred and eighty genes were increased in human and pig kidney vs. human brain samples. Of the top 25 genes increased in pig kidney compared with human brain, we were able to cross-reference 18 genes to the Unigene and SAGE public databases. We confirmed the expected higher levels of expression in the kidney in 18 genes. Of the top 25 genes increased in human brain vs. pig kidney, we were able to cross-reference 20 genes to the Unigene and SAGE databases and confirm the expected higher expression levels in brain in 17 genes with three inconclusive genes. CONCLUSION: This low level of false positive findings, at this preliminary stage, supports the concept of using human GeneChip microarray platform to compare gene expression profiles between pig and human tissues in the absence of a porcine microarray platform. Our study opens a new avenue into the analysis of porcine genes relevant to xenotransplantation.

Animals↗

A novel extracorporeal kidney perfusion system: a concept model.

The number of patients awaiting kidney transplantation has more than doubled in the past decade while the number of available donor organs has seen only a modest increase, leading to a critical shortage of organs. In response to this extreme shortage, the criteria for accepting organs have been modified to include marginal donors such as non-heart beating donors (NHBD). In these kidneys, determining viability is important for success of transplantation. Therefore, a study was undertaken to develop a system that would allow the extracorporeal assessment of function and compatibility of the donor organ before the patient is exposed to the risks associated with surgery. Following bilateral nephrectomy, the kidneys of 10 pigs (approximately 30 kg) were connected to a commercially available hypothermic pulsatile kidney perfusion apparatus. This system was modified to allow for normothermic pulsatile renal perfusion using the potential recipient's blood, via vascular access. These kidneys were perfused with the animal's blood for a minimum of two hours while various parameters were monitored. Perfusion pressures were kept between 60 and 90 mmHg, which correlated to flows between 70 and 150 mL/min. A decrease in perfusion pressure with a concomitant rise in flow over the two-hour period served as a good predictor of a viable and compatible graft. The modified kidney preservation system allows the normothermic, pulsatile extracorporeal perfusion of donor kidneys with the ability to monitor resistance to flow and urine production. This model also allows observation of the kidney for signs of hyperacute rejection. Further research needs to be conducted in order to determine if the system represents a methodology to increase the pool of available donor organs.

Animals↗

Correlation between glomerular size and long-term renal function in patients with substantial loss of renal mass.

PURPOSE: Focal segmental glomerulosclerosis and progressive renal failure have been reported in reduced renal mass models. However, these findings are not consistent across all species. Increased intracapillary pressure and chronic glomerular hyperfiltration have been shown to contribute to this progression. Studies also have shown that a strong correlation exists between higher glomerular size and the degree of glomerular sclerosis that develops following loss of functioning nephrons. MATERIALS AND METHODS: To evaluate the relationship between glomerular size and long-term renal function following massive renal mass removal we describe 9 patients with less than 50% renal mass. All patients had undergone initial nephrectomy followed by partial second nephrectomy, with 30% to 50% of the second kidney excised for localized tumor. RESULTS: In 3 patients moderate to severe renal failure developed. Mean planar glomerular area (MPA) was 29.45 +/- 2.2 mm3 for all patients. Multivariate linear regression analysis demonstrated a significant association between MPA 30 mm3 or greater and increased serum creatinine. For patients with MPA 30 mm3 or greater the predicted delta creatinine was 2.43 mg/dl higher than that in patients with MPA less than 30 mm3 (p = 0.0028). Age was the only other covariate significantly associated with outcome in multivariate analysis. CONCLUSIONS: Our data indicate an individual susceptibility toward developing renal failure after significant renal mass reduction. We suggest that patients with less than 50% renal mass and higher MPA are at greater risk for progressive renal failure. MPA may be used as a marker in high risk patients with substantial loss of renal mass to predict long-term renal function.

Aged↗

Improved treatment response with basiliximab immunoprophylaxis after liver transplantation: results from a double-blind randomized placebo-controlled trial.

Basiliximab, a high-affinity chimeric monoclonal antibody, is effective in reducing acute rejection episodes in renal allograft recipients. We assessed the ability of this antibody to similarly improve the outcome in liver transplant recipients. Adult recipients of a primary cadaveric liver transplant were randomized to treatment, stratified by hepatitis C virus (HCV) seropositivity. Patients were administered 40 mg of basiliximab (n = 188) or placebo (n = 193) as two 20-mg bolus injections days 0 and 4, plus cyclosporine and steroids. Primary efficacy variables were biopsy-confirmed acute rejection and its composite end point, including death or graft loss, and were assessed at 6 and 12 months and by HCV cohort. Because of differential efficacy responses between HCV-positive and HCV-negative cohorts, an additional analysis incorporating HCV recurrence as a component of treatment failure, termed problem-free transplant, was introduced. Safety and tolerability were monitored over the 12 months of the study. All 381 patients were assessable, and no meaningful differences in background characteristics were apparent between treatment groups. Biopsy-confirmed acute rejection rates 6 months after transplantation were 35.1% in the basiliximab group versus 43.5% in the placebo group. For death, graft loss, or first biopsy-confirmed acute rejection, rates were 44.1% versus 52.8%, respectively. The reduction in rejection episodes was concentrated in the HCV-negative cohort (14.5% relative to placebo; P =.034), with a much smaller difference (2.9%) in the HCV-positive cohort. For HCV-positive patients, problem-free transplant was shown at 12 months in 26.6% of the basiliximab group versus 11.6% in the placebo group (P =.020) and for all patients at 12 months in 39.7% of the basiliximab group versus 30.1% in the placebo group (P =.035). The incidence of infection and other adverse events was similar across the two treatment groups. There were 56 deaths (25 deaths, basiliximab group; 31 deaths, placebo group) over the 12-month study. The intravenous bolus injection was well tolerated. Immunoprophylaxis with 40 mg of basiliximab, in combination with cyclosporine and steroids, reduces the incidence of acute rejection episodes with no clinically relevant safety or tolerability concerns. The influence of HCV recurrence on efficacy results can be accounted for in future trials by using the concept of problem-free transplant, incorporating recurrence as a component of treatment failure.

Adult↗