Trained artificial neural network for glaucoma diagnosis using visual field data: a comparison with conventional algorithms.

PURPOSE: To evaluate and confirm the performance of an artificial neural network (ANN) trained to recognize glaucomatous visual field defects, and compare its diagnostic accuracy with that of other algorithms proposed for the detection of visual field loss. METHODS: SITA Standard 30-2 visual fields, from 100 glaucoma patients and 116 healthy participants, formed the data set. Our ANN was a previously described fully trained network using scored pattern deviation probability maps as input data. Its diagnostic accuracy was compared to that of the Glaucoma Hemifield Test, the Pattern Standard Deviation index at the P<5% and <1%, and also to a technique based on the recognizing clusters of significantly depressed test points. RESULTS: The included tests had early to moderate visual field loss (median MD=-6.16 dB). ANN achieved a sensitivity of 93% at a specificity level of 94% with an area under the receiver operating characteristic curve of 0.984. Glaucoma Hemifield Test attained a sensitivity of 92% at 91% specificity. Pattern Standard Deviation, with a cut off level at P<5% had a sensitivity of 89% with a specificity of 93%, whereas at P<1% the sensitivity and specificity was 72% and 97%, respectively. The cluster algorithm yielded a sensitivity of 95% and a specificity of 82%. CONCLUSIONS: The high diagnostic performance of our ANN based on refined input visual field data was confirmed in this independent sample. Its diagnostic accuracy was slightly to considerably better than that of the compared algorithms. The results indicate the large potential for ANN as an important clinical glaucoma diagnostic tool.

Adult↗

Effects of input data on the performance of a neural network in distinguishing normal and glaucomatous visual fields.

PURPOSE: To compare the performance of neural networks for perimetric glaucoma diagnosis when using different types of data inputs: numerical threshold sensitivities, Statpac Total Deviation and Pattern Deviation, and probability scores based on Total and Pattern Deviation probability maps (Carl Zeiss Meditec, Inc., Dublin, CA). METHODS: The results of SITA Standard visual field tests in 213 healthy subjects, 127 patients with glaucoma, 68 patients with concomitant glaucoma and cataract, and 41 patients with cataract only were included. The five different types of input data were entered into five identically designed artificial neural networks. Network thresholds were adjusted for each network. Receiver operating characteristic (ROC) curves were constructed to display the combinations of sensitivity and specificity. RESULTS: Input data in the form of Pattern Deviation probability scores gave the best results, with an area of 0.988 under the ROC curve, and were significantly better (P < 0.001) than threshold sensitivities and numerical Total Deviations and Total Deviation probability scores. The second best result was obtained with numerical Pattern Deviations with an area of 0.980. CONCLUSIONS: The choice of type of data input had important effects on the performance of the neural networks in glaucoma diagnosis. Refined input data, based on Pattern Deviations, resulted in higher sensitivity and specificity than did raw threshold values. Neural networks may have high potential in the production of useful clinical tools for the classification of visual field tests.

Adult↗