PubMed Health⌕ Search

Biomedical subjects

Dimitris Mitsouras

Publications and source records attributed to Dimitris Mitsouras.

4 recordsLinked to original sources

Enhancing the acquisition efficiency of fast magnetic resonance imaging via broadband encoding of signal content.

Current efficient magnetic resonance imaging (MRI) methods such as parallel-imaging and k-t methods encode MR signals using a set of effective encoding functions other than the Fourier basis. This work revisits the proposition of directly manipulating the set of effective encoding functions at the radiofrequency excitation step in order to increase MRI efficiency. This approach, often termed "broadband encoding," enables the application of algebraic matrix factorization technologies to extract efficiency by representing and encoding MR signal content in a compacted form. Broadband imaging equivalents of fast multiecho, parallel and k-t MRI are developed and analyzed. The potential of these techniques to increase the time efficiency of data acquisition is experimentally verified on a commercial MRI scanner using simple spin-echo imaging. A three-dimensional gradient-echo dynamic imaging application that demonstrates the potential benefits of this approach compared to the present state of the art for certain applications is also presented.

Fourier Analysis↗

Generalized encoding through the use of selective excitation in accelerated parallel MRI.

Selective RF excitation is employed in magnetic resonance imaging (MRI) to achieve a variety of effects, such as slice selection. More elaborate transverse magnetization patterns can be realized via tailored RF excitation pulses, useful for example to image any specific region geometry within the field of view, or, to acquire non-Fourier encoded samples of the underlying magnetization distribution. In this manuscript, we review prior work on the combination of selective RF excitation with parallel MRI acquisition techniques. This combination can be used both to advantageously manipulate the numerical conditioning of the reconstruction problem, as well as to compact the information content of the acquired data so as to improve the achievable acceleration rate. With the latter application it is possible to also consider the acceleration provided by parallel imaging alone as a compaction of information content, which in certain cases can be used to reduce the length of the selective excitations. The main contribution of this review is to show how the combination of selective excitation with parallel imaging provides the latter an added flexibility that can be used to either enhance image quality, increase imaging speed, or both.

Algorithms↗

Strategies for inner volume 3D fast spin echo magnetic resonance imaging using nonselective refocusing radio frequency pulses.

Fast spin echo (FSE) trains elicited by nonselective "hard" refocusing radio frequency (RF) pulses have been proposed as a means to enable application of FSE methods for high-resolution 3D magnetic resonance imaging (MRI). Hard-pulse FSE (HPFSE) trains offer short (3-4 ms) echo spacings, but are unfortunately limited to imaging the entire sample within the coil sensitivity thus requiring lengthy imaging times, consequently limiting clinical application. In this work we formulate and analyze two general-purpose combinations of 3D HPFSE with inner volume (IV) MR imaging to circumvent this limitation. The first method employs a 2D selective RF excitation followed by the HPFSE train and focuses on required properties of the spatial excitation profile with respect to limiting RF pulse duration in the 5-6 ms range. The second method employs two orthogonally selective 1D RF excitations (a 90x degrees - 180y degrees pair) to generate an echo from magnetization within the volume defined by their intersection. Subsequent echoes are formed via the HPFSE train, placing the focus of the method on (a) avoiding spurious echoes that may arise from transverse magnetization located outside the slab intersection when it is unavoidably affected by the nonselective refocusing pulses and (b) avoiding signal losses due to the necessarily different spacing (in time) of the RF pulse applications. The performance of each method is experimentally measured using Carr-Purcell-Meiboom-Gill (CPMG) multi-echo imaging, enabling examination of the magnetization evolution throughout the echo train. The methods as implemented achieve 95% to 97% outer volume signal suppression, and higher suppression appears to be well within reach, by further refinement of the selective RF excitations. Example images of the human brain and spine are presented with each technique. We conclude that the SNR efficiency of volume imaging in conjunction with the short echo spacing afforded by hard pulse trains enables high-resolution 3D HPFSE MRI of a small field-of-view (FOV) with minimal aliasing artifact.

Algorithms↗

Non-Fourier-encoded parallel MRI using multiple receiver coils.

This paper describes a general theoretical framework that combines non-Fourier (NF) spatially-encoded MRI with multichannel acquisition parallel MRI. The two spatial-encoding mechanisms are physically and analytically separable, which allows NF encoding to be expressed as complementary to the inherent encoding imposed by RF receiver coil sensitivities. Consequently, the number of NF spatial-encoding steps necessary to fully encode an FOV is reduced. Furthermore, by casting the FOV reduction of parallel imaging techniques as a dimensionality reduction of the k-space that is NF-encoded, one can obtain a speed-up of each digital NF spatial excitation in addition to accelerated imaging. Images acquired at speed-up factors of 2x to 8x with a four-element RF receiver coil array demonstrate the utility of this framework and the efficiency afforded by it.

Calibration↗