PubMed Health⌕ Search

Biomedical subjects

Dirk Schaumlöffel

Publications and source records attributed to Dirk Schaumlöffel.

12 recordsLinked to original sources

Capillary HPLC-ICP MS mapping of selenocompounds in spots obtained from the 2-D gel electrophoresis of the water-soluble protein fraction of selenized yeast.

A method based on ICP collision-cell MS detection in capillary HPLC was developed to gain an insight into the purity and identity of selenium-containing proteins separated by 1-D and 2-D electrophoresis. The bands and spots obtained after the separation of water-soluble proteins in selenized yeast were digested with trypsin prior to chromatography. Selenium could be detected down to the subpicogram level. The method, assisted by information obtained by MALDI TOF MS on the 5000 Da cut-off fraction, permitted the purity of bands and spots to be estimated and the efficiency of tryptic digestion and the quantity of selenium present in individual peptides to be evaluated. Owing to the high sensitivity and the lack of matrix suppression effects, the method provided chromatograms with signal-to-noise ratios of 10-1000 in conditions where the common ES Q-TOF MS detection failed.

Chromatography, High Pressure Liquid↗

Fractionation of selenium-containing proteins in serum by multiaffinity liquid chromatography before size-exclusion chromatography-ICPMS.

Immunoaffinity chromatography has been investigated for fractionation of serum into selenoalbumin and true selenoproteins. Among several albumin-depletion kits tested, a multiaffinity column specifically binding albumin and five other major serum proteins provided the best results. It extracted ca 95% of both albumin and selenoalbumin, which enabled interference-free determination of glutathione peroxidase, selenoprotein P, and selenoalbumin by size-exclusion chromatography combined with inductively coupled plasma mass spectrometry (SEC-ICPMS). The efficiency of the multiaffinity column did not vary over a period of 18 months. The purity of fractions separated by immunoaffinity LC was confirmed by elution-volume matching with standards in SEC-ICPMS and by selenopeptide mapping in capillary HPLC-ICPMS. Quantification of the selenium distribution among the different proteins in human serum from a control group and from a person on a selenium-rich diet revealed that 67% of the supplemented selenium was incorporated into albumin, 30% into glutathione peroxidase, and 3% into selenoprotein P.

Albumins↗

Development of a nebulizer for a sheathless interfacing of NanoHPLC and ICPMS.

A novel nebulizer (nDS-200) working at sample uptake rates of less than 500 nL min(-1) was developed for a sheathless interfacing of nanoHPLC (75-microm column i.d.) with ICPMS. It was based on a hollow fused-silica needle of which the tip (i.d. 10 microm, o.d. 20 microm) centered in a 254-microm-i.d. sapphire orifice. The nebulizer, equipped with a 3-cm(3) drain-free vaporization chamber, enabled a stable introduction into an ICP of aqueous mobile phases containing up to 95% acetonitrile at eluent flow rates between 50 and 450 nL min(-1). The low dead volume of the interface resulted in a peak width of 1.3 s (at half-height) and the entirely preserved chromatographic resolution. An example application of the coupling to the analysis of a tryptic digest of a SIP18 protein containing two to nine selenomethionine residues was described. The absolute detection limit was 25 fg (80Se), which allowed the detection of low-abundant selenopeptides at the femtomole level. In contrast to electrospray MS, the ICPMS detection in nanoHPLC is unaffected by the coeluting matrix and concomitant compounds and offers an elegant method for the detection and quantification of minor heteroelement-containing species prior to or in parallel with ESI MS analysis.

Chromatography, High Pressure Liquid↗

Determination of selenomethionine and selenocysteine in human serum using speciated isotope dilution-capillary HPLC-inductively coupled plasma collision cell mass spectrometry.

A method for the accurate determination of selenoamino acids in human serum by HPLC-ICPMS was developed using the species-specific isotope dilution analysis principle. A serum sample was enzymatically digested with a mixture of lipase and protease after derivatization of the selenocysteine residues with iodoacetamide. The selenoamino acid fraction was isolated by size exclusion LC followed by the separation of selenomethionine and the carboxymethylated selenocysteine by capillary HPLC. The isotope-specific determination of 77Se and 80Se was achieved on-line by ICP collision cell MS allowing the removal of polyatomic interferences. Quantification was carried out by isotope dilution using a 77Se-labeled selenomethionine spike and the determination of the 77Se/80Se ratio in the cHPLC selenomethionine peak. The accurately determined selenomethionine was used as an internal standard for the selenocysteine determination from the same chromatogram. The modification of the previously developed cHPLC-ICPMS interface allowed the reduction of the absolute detection limits twice (down to the 75-fg level), which resulted in the lowest ever reported procedural detection limits (below 0.5 ng g(-1) for a 450-mg serum sample). The precision was less than 5% RSD. The method was validated by the mass balance of selenium (amino acid incorporated vs total).

Chromatography, Gel↗

Development of a sheathless interface between reversed-phase capillary HPLC and ICPMS via a microflow total consumption nebulizer for selenopeptide mapping.

A sheathless interface based on a total consumption micronebulizer operating at flow rates in the range 0.5-7.5 microL min(-1) was developed between capillary HPLC and ICPMS. It allowed the efficient nebulization and transport into the plasma of mobile phases containing up to 100% organic solvent without either cooling the spray chamber or oxygen addition. The coupled system was applied to selenopeptide mapping in a protein fraction isolated from a selenized yeast extract. The detection limits were 150 (80Se) and 200 fg (82Se) for a quadrupole instrument with and without a collision cell, respectively, which is a factor 100-150 less than that reported elsewhere for HPLC-ICPMS. The minimal peak broadening ( approximately 5 s at the half-height) allowed baseline resolution of a mixture containing more than 30 selenopeptides, many of which could not be separated using the conventional HPLC-ICPMS coupling.

Chromatography, High Pressure Liquid↗

Speciation of nickel in a hyperaccumulating plant by high-performance liquid chromatography-inductively coupled plasma mass spectrometry and electrospray MS/MS assisted by cloning using yeast complementation.

A novel analytical approach based on a combination of multidimensional hyphenated techniques and cloning of the Ni-resistance gene using yeast complementation screens was developed for the identification of nickel species in a Thlaspi caerulescens hyperaccumulating plant. The presence of an unknown strong Ni complex was demonstrated by size exclusion HPLC-capillary electrophoresis with ICPMS detection. The Ni-containing peak was characterized by electrospray MS (m/z 360) and shown by collision-induced dissociation MS to be a chelate with a tricarboxylic amino acid ligand. To identify the species and demonstrate its functional character, a cDNA library was constructed from T. caerulescens, expressed in the yeast, and screened on a toxic Ni2+ medium. The extract from the surviving transformant culture gave identical HPLC-ICPMS, CZE-ICPMS, and ES MS/MS data and contained a cDNA insert homologous to the nicotianamine synthase gene. This observation allowed the identification of nicotianamine as the nickel-binding ligand. The presence of the Ni-nicotianamine complex was ultimately demonstrated by comparing tandem mass spectra of the plant and yeast extracts with those of a synthetic standard.

Chromatography, High Pressure Liquid↗

Multi-element speciation of metalloproteins in fish tissue using size-exclusion chromatography coupled "on-line" with ICP-isotope dilution-time-of-flight-mass spectrometry.

An on-line isotope dilution (ID) method in combination with the coupling of size-exclusion high-performance liquid chromatography (SE-HPLC) to an axial inductively coupled plasma time-of-flight mass spectrometer (ICP-TOFMS) was applied to the quantitative speciation of Cu, Zn and Cd in carp and eel cytosols. Quantitative information on the distribution of essential and toxic metals between the different molecular weight fractions in kidney cytosols of control and Cd exposed carp was obtained with species-unspecific spiking by post-column addition of the enriched isotopes 65Cu, 67Zn and 106Cd. The isotope ratios 63Cu/65Cu, 64Zn/67Zn and 114Cd/106Cd, were monitored by ICP-TOFMS in transient signal mode. The determination of the total cytosolic element concentration was performed by flow injection conventional nebulization ICP-TOFMS. Speciation differences were encountered between control and Cd-stressed carp, indicating that quantitative speciation studies might be useful for ecotoxicological and biomonitoring purposes. Application of this methodology to quantitation of metals associated with metallothioneins (MT) in European eel, sampled at three different sites in Flanders, Belgium was also addressed. A significant increase of the amount of Cd, Cu and Zn bound to hepatic MT was observed with the increase of the total metal and MT concentrations of hepatic eel tissue.

Animals↗

CZE-ICP-MS separation of metallothioneins in human brain cytosols: comparability of electropherograms obtained from different sample matrices.

Capillary zone electrophoresis, with its high resolution capability in the separation of different compounds, is well suited for the investigation of metal-containing proteins, especially when elemental detection is conducted using hyphenated inductively coupled plasma-mass spectrometry. A major problem in the separation of proteins in body fluids is caused by the effects of different sample matrix composition. The migration time of proteins varies significantly, depending on the nature of the matrix. Electropherograms are consequently difficult to compare and the peak identification is uncertain. Pre-analytical steps for the reduction of matrix compounds enhance the quality of the data, but the results are still unsatisfactory. This paper describes a technique for obtaining electropherograms that can be used for comparison purposes by correction of the data with the aid of time markers. A mixture of five substances (caesium chloride, arsenocholine, arsenobetaine, dimethylarsinic acid and monomethylarsonic acid) was added in a separate injection step. Ionic caesium eluted at the start of the separation and the other four markers appeared throughout and at the end of the electropherogram. All electropherograms were normalized to a reference run by recalculation of the time axis using the time markers. The method was applied to the analysis of human brain cytosols. Samples were separated after different pre-treatment steps and were compared, with special emphasis on the detection of the isoform metallothionein-3.

Brain Chemistry↗

Hyphenated techniques for the characterization and quantification of metallothionein isoforms.

Recent developments in the coupling of highly selective separation techniques such as capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC) to element-specific and molecule-specific detectors, such as inductively-coupled plasma mass spectrometry (ICP-MS) and electrospray ionization-tandem mass spectrometry (ESI-MS/MS) for the characterization and quantification of metallothioneins (MTs) are critically reviewed and discussed. This review gives an update based on the literature over the last five years. The coupling of CE to ICP-MS is especially highlighted. As a result of progress in new interface technologies for CE-ICP-MS, research topics presented in the literature are changing from "the characterization of interfaces by metallothioneins" to the "characterization of metallothioneins by CE-ICP-MS". New applications of CE-ICP-MS to the analysis of MTs in real samples are summarized. The potential of the on-line isotope dilution technique for the quantification of MTs and for the determination of the stoichiometric composition of metalloprotein complexes is discussed. Furthermore, a selection of relevant papers dealing with HPLC-ICP-MS for MT analysis are summarized and compared to those dealing with CE-ICP-MS. In particular, the use of size-exclusion (SE)-HPLC as a preliminary separation step for metallothioneins in real samples prior to further chromatographic or electrophoretic separations is considered. Additionally, the application of electrospray ionisation-tandem mass spectrometry (ESI-MS/MS) for the identification of metallothionein isoforms following electrophoretic or chromatographic separation is discussed.

Animals↗

Characterization and quantification of metallothionein isoforms by capillary electrophoresis-inductively coupled plasma-isotope-dilution mass spectrometry.

In a new approach to the characterization and quantification of metallothionein isoforms an on-line isotope-dilution method in combination with the coupling of capillary electrophoresis (CE) to an inductively coupled plasma-sector field mass spectrometer (ICP-SFMS) is reported. Metallothionein (MT) isoforms are separated by CE and the elements Cu, Zn, Cd, and S are detected simultaneously by use of ICP-SFMS in the medium resolution mode. On-line isotope dilution is performed by continuous introduction of an isotopically enriched, species-unspecific spike solution after the separation step. MT from rabbit liver and a further purified MT-1 isoform were quantified by determination of sulfur, and the stoichiometric compositions of the metalloprotein complexes are characterized by determination of their sulfur-to-metal ratios.

Algorithms↗

Mass spectrometry in bioinorganic analytical chemistry.

A considerable momentum has recently been gained by in vitro and in vivo studies of interactions of trace elements in biomolecules due to advances in inductively coupled plasma mass spectrometry (ICP MS) used as a detector in chromatography and capillary and planar electrophoresis. The multi-isotopic (including non-metals such as S, P, or Se) detection capability, high sensitivity, tolerance to matrix, and large linearity range regardless of the chemical environment of an analyte make ICP MS a valuable complementary technique to electrospray MS and MALDI MS. This review covers different facets of the recent progress in metal speciation in biochemistry, including probing in vitro interactions between metals and biomolecules, detection, determination, and structural characterization of heteroatom-containing molecules in biological tissues, and protein monitoring and quantification via a heteroelement (S, Se, or P) signal. The application areas include environmental chemistry, plant and animal biochemistry, nutrition, and medicine.

Chemistry, Bioinorganic↗