PubMed Health⌕ Search

Biomedical subjects

Dmitri B Papkovsky

Publications and source records attributed to Dmitri B Papkovsky.

12 recordsLinked to original sources

The use of a fluorescence-based oxygen uptake assay in the analysis of cytotoxicity.

Cellular oxygen uptake is an informative parameter of cellular function but is not measured routinely in the analysis of cytotoxicity. Here we have evaluated the ability of a fluorescence-based oxygen uptake assay to assess the metabolic activity of common adherent cells including HepG2, LLC-PK1, Hek293T, C2C12, H-4-II-E, and primary rat hepatocytes. The assay employs water-soluble phosphorescent oxygen probes, analysed in standard 96-well plates on a conventional fluorescence plate reader. Using this respirometric method, cellular responses to known toxicants were examined and results compared to those obtained using established cell viability assays such as MTT, LDH and CyQuant. Respirometric analysis successfully detected these cytotoxic insults with responses being influenced by both mode of toxicity and the biochemical characteristics of the individual cell line. Results indicate that the oxygen uptake assay was more sensitive to the impairment of mitochondrial function than the other assays used. In conjunction with assays analysing other biomarkers of cytotoxicity, a more detailed picture of cell response to drug treatment can be obtained.

Animals↗

Fluorescence based oxygen uptake analysis in the study of metabolic responses to apoptosis induction.

Mitochondrial activity has been shown to be centrally involved in the progression of apoptosis. The electron transport chain is a major player in this process and oxygen uptake analysis provides detailed information on its activity. Here we examined the ability of a fluorescence based oxygen uptake assay to inform on cellular responses to apoptosis induction. HL60 cells treated with camptothecin and UV light were used as a model and the ability of the assay to detect dose and time dependent decreases in respiratory activity analysed. The data obtained were compared to more specific markers of apoptosis including annexin V binding, and caspase-3 activity. Reductions in oxygen uptake rates were seen at lower doses than increases in annexin V binding or mitochondrial membrane potential depolarisation. These reductions were observed earlier than detectable caspase-3 activity and were unaffected by pre-treatment with the caspase-3 inhibitor benzyloxycarbonyl-Val-Ala-Asp-fluoro-methylketone (zVADfmk).

Amino Acid Chloromethyl Ketones↗

Homogeneous assays for cellular proteases employing the platinum(II)-coproporphyrin label and time-resolved phosphorescence.

Phosphorescent platinum(II) coproporphyrin label (PtCP) is evaluated for the detection of cellular proteases by time-resolved fluorescence in homogeneous format. An octameric peptide containing the recognition motif for the caspase-3 enzyme was dual labeled with a new maleimide derivative of PtCP and with the dark quencher dabcyl. Following photophysical characterization, the quenched substrate was employed in cleavage assays for caspase-3 using Jurkat and HL60 cell lines treated with proapoptotic stimuli performed on a commercial plate reader. Dose-response and time course assays for the drug camptothecin were obtained for comparison with conventional fluorometric detection.

Camptothecin↗

Optical oxygen microrespirometry as a platform for environmental toxicology and animal model studies.

We present a new methodology for testing physiological responses of small organisms (size 70-500 microm) via changes in their oxygen respiration monitored by quenched-phosphorescence oxygen sensing on a scale of a single organism. The method is demonstrated using three different formats of respirometric assays, Artemia salina and mouse embryos as model animals, and various effectors including compounds that induce and prevent superoxide-mediated and heavy metal ion toxicity. These assays, which employ soluble oxygen probes, standard fluorescent readers, and accessorytools, provide sensitive, noninvasive, real-time monitoring of animal respiration, and rapid assessment of EC50, sublethal effects, and metabolic alterations. Applications include screening for acute toxicity of compound libraries and environmental samples, and the study of animal physiology and metabolism.

Animals↗

Emerging applications of phosphorescent metalloporphyrins.

The subject of phosphorescent metalloporphyrins is reviewed, focusing mainly on the development and application of Pt- and Pd-porphyrins. A summary of their general chemical and photophysical properties, and guidelines for rational design of the phosphorescent labels, bioconjugates and probes is given. Examples of different detection formats and particular bio-analytical applications developed in recent years are presented. The potential of phosphorescent porphyrin label methodology is discussed and compared to that of the long-decay fluorescent lanthanide chelates and other common fluorophores.

Biological Assay↗

A low-volume platform for cell-respirometric screening based on quenched-luminescence oxygen sensing.

Cell viability assays represent an important technology in modern cell biology, drug discovery and biotechnology, where currently there is a high demand for simple, sensitive and cost-effective screening methods. We have developed a new methodology and associated tools for cell-based screening assays, which are based on the measurement of the rates of oxygen uptake in cells by luminescence quenching. Sealable microchamber devices matching the footprint of a standard 96-well plate were developed and used in conjunction with long-decay phosphorescent oxygen probes. These devices permit cell non-invasive, real-time monitoring of cellular respiration and a rapid, one-step, kinetic assessment of multiple samples for cell viability, drug/effector action. These assays can be carried out on conventional fluorescence plate readers, they are suitable for different types of cells, including adherent and slow-respiring cells, require small sample volumes and cell numbers, and are amenable for high throughput screening. Monitoring of as little as 300 mammalian cells in 3 microl volume has been demonstrated.

Biosensing Techniques↗

Evaluation of the phosphorescent palladium(II)-coproporphyrin labels in separation-free hybridization assays.

Palladium(II)-coproporphyrin label and a set of corresponding monofunctional labeling reagents with different linker arms were evaluated for labeling of oligonucleotides and subsequent use in hybridization assays. The properties of resulting oligonucleotide probes including phosphorescence spectra, quantum yields, lifetimes, and labeling yields were examined as functions of the label and oligonucleotide structures. Upon hybridization with complementary sequences bearing dabcyl, QSY-7, and rhodamine green dyes, the probes displayed strong quenching due to close proximity effects. Intensity and lifetime changes of the phosphorescence, distance, and temperature dependences were investigated in detail. The potential of the new label and probes for sensitive and separation-free hybridization assays was discussed.

Biological Assay↗

Fluorescence-based cell viability screening assays using water-soluble oxygen probes.

A simple luminescence-based assay for screening the viability of mammalian cells is described, based on the monitoring of cell respiration by means of a phosphorescent water-soluble oxygen probe that responds to changes in the concentration of dissolved oxygen by changing its emission intensity and lifetime. The probe was added at low concentrations (0.3 microM to 0.5 nM) to each sample containing a culture of cells in the wells of a standard 96-well plate. Analysis of oxygen consumption was initiated by applying a layer of mineral oil on top of each sample followed by monitoring of the phosphorescent signal on a prompt or time-resolved fluorescence plate reader. Rates of oxygen uptake could be determined on the basis of kinetic changes of the phosphorescence (initial slopes) and correlated with cell numbers (10(5) to 10(7) cells/mL for FL5.12 lymphoblastic cell line), cell viability, or drug/effector action using appropriate control samples. The assay is cell noninvasive, more simple, robust, and cost-effective than existing microplate-based cell viability assays; is compatible with existing instrumentation; and allows for high-throughput analysis of cell viability.

Apoptosis↗

Performance evaluation of the phosphorescent porphyrin label: solid-phase immunoassay of alpha-fetoprotein.

Phosphorescent conjugates of antibodies, neutravidin, and biotin (pentylamine derivative) were synthesized using previously described monofunctional labeling reagent of platinum(II) coproporphyrin-I with isothiocyanate reactive group (PtCP-NCS). These conjugates, which can be considered as standard reagents for a range of bioanalytical applications, were evaluated in solid-phase immunoassay schemes with the clinical analyte a-fetoprotein (AFP). A custom-designed time-resolved phosphorescence plate reader based on a compact and low-cost 532-nm laser and optimized for measurement of porphyrin labels was used. Using optimized tracers, instrumentation and assay protocols, subpicomolar detection limits were obtained both for PtCP label in solution and for AFP in solid-phase immunoassay. This sensitivity is comparable with standard time-resolved fluorescence immunoassays with lanthanide labels. The performance of metalloporphyrin labels, instrumentation, and solid-phase immunoassays as an alternative to the established detection platforms is discussed.

Biotin↗

Synthesis and evaluation of phosphorescent oligonucleotide probes for hybridisation assays.

Monofunctional, p-isothiocyanatophenyl-derivatives of platinum (II)-coproporphyrin-I (PtCP-NCS) were evaluated as phosphorescent labelling reagents for synthetic oligonucleotides containing a 3'- or 5'-amino modification. Synthesis and purification conditions were optimised to generate high yields and purity of PtCP-labelled oligonucleotide probes. Phosphorescent properties of the PtCP label have been shown to be largely unaffected by conjugation to oligonucleotides of various length, GC composition and label attachment site. 5'-PtCP-labelled oligonucleotides were shown to work efficiently as primers in a standard PCR. A dedicated 532 nm laser-based time-resolved fluorescence plate reader enabled highly sensitive detection of PtCP-labelled oligonucleotides and PCR products, both in solution and in agarose gels, with limits of detection in the order of 0.3 pM. A model system employing two complementary oligonucleotides labelled with PtCP and QSY 7 dye (dark quencher) showed strong (approximately 20-fold) and specific proximity quenching of PtCP label upon hybridisation in solution. The potential applications of PtCP-labelled probes in hybridisation assays were discussed.

Luminescent Measurements↗

Phosphorescent metalloporphyrins as labels in time-resolved luminescence microscopy: effect of mounting on emission intensity.

In this study, we present an investigation of the effects of mounting media on the phosphorescence of metalloporphyrin stained microscopy samples. The samples were: (1) Platinum(II) coproporphyrin (=PtCP) stained porous Sephadex beads; (2) compact polystyrene microspheres coated with IgG-PtCP conjugate; and (3) immunocytochemically labeled human peripheral blood neutrophils. The human neutrophils in a mixed leukocyte population were fixed, permeabilized, and then immunolabeled with PtCP conjugate of monoclonal mouse IgG directed to the intracellular antigen myeloperoxidase. The samples were mounted in twelve different mounting media and studied with quantitative time-resolved luminescence imaging microscopy with respect to the intensity and stability of the phosphorescence signal. The results indicate that microscopy samples stained with PtCP exhibit the brightest phosphorescence emission in non-mounted form or when mounted in non-aqueous permanent mounting media.

Animals↗